What was found
DURING INSPECTION, FOUND CORROSION ON CENTER FITTING LOCATED BETWEEN FR 16 AND FR 20 AT LEVEL STR 23 RT L=0.500" W=0.250" D=0.001" APPROX. REPLACED CENTER FITTING IAW SRM 51-72-11 AND DWG D53112198.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION ON CENTER FITTING LOCATED BETWEEN FR 16 AND FR 20 AT LEVEL STR 23 RT L=0.500" W=0.250" D=0.001" APPROX. REPLACED CENTER FITTING IAW SRM 51-72-11 AND DWG D53112198.