JASC 5340
Service difficulty reports · 22,399
Reports filed under 5340 · Fuselage Main, Attach Fittings, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5340' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5340' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2024090402381Fitting · crackedCABIN STA 928 RBL 94 FRAME AND CTR SECTION UPR SURFACE MOUNT FITTING FOUND CRACKED. CABIN STA 928 RBL 94 FRAME AND CENTER SECTION UPPER SURFACE INSPECTED. MOUNT FITTING REPLACED AS PER SRM 51-10-02 AND NEW FITTING INSTALLED AS PER SRM 51-40-02.SDR AALA202408203842Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN CENTER WING BOX FORWARD SPAR UPPER SHEAR FITTING AT BS 540 AND LBL 40.87. REPLACED SHEAR FITTING PER AARD 57-14-00-1 REPAIR 1. THIS ACCOMPLISHES BOEING SB-737-57-1309.SDR AALA202408202691Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN CENTER WING BOX FORWARD SPAR UPPER SHEAR FITTING AT BS 540 AND LBL 54.60. REPLACED SHEAR FITTING PER AARD 57-14-00-1 REPAIR 1. THIS ACCOMPLISHES BOEING SB-737-57-1309.SDR DALA2024082208355Tie Down · corroded(LOG 0514118) CORROSION AROUND FLOOR TIE DOWN AT STA 947 LBL 49 WL 208. REMOVED AND REPLACED INTERCOSTAL AT STA 947 TO STA 967, LBL 49, WL 208 IAW B737 SRM 51-40-02-0G AND BOEING DWG# 147A5650 REV: A.SDR SWAA2024092427353Stringer Clip · crackedCRACK TIE CLIP LOCATED STA277 AND STR10R AT PASSENGER CABIN 2024-512458<[01] REPLACED TIE CLIP LOCATED STA277 AND STR10R AT PASSENGER CABIN I.A.W. B737-800 SRM 51-40-02; SRM 51-10-02 ITEM 9 AND DWG: 141A1110 SHEET: 39; REV: -; AND DWG: 141A8380; SHEET: 21; REVSDR SWAA2024092426988Stringer Clip · crackedCRACK TIE CLIP LOCATED STA500I AND STR26R FWD CARGO COMPARTMENT 2024-512418<[01] REPLACED TIE CLIP LOCATED ON BS500I STR26R AT FWD CARGO COMPARTMENT I.A.W. B737-800 SRM 51-40-02 AND DWG 143A1234 SHEET 13 REV. A<BR><BR>SEE INDIVIDUAL SIGN-OFF BELOW;[02] REPLACESDR LR7A2024081603457Attach Angle · corrodedDURING SCHEDULED C-15 CHECK WHILE PERFORMING OTHER MAINTENANCE, FOUND LH PORK CHOP ATTACH ANGLE CORRODED AT FS577, LBL60, WL136. / REPAIR BY REPLACEMENT ACCOMPLISHED IAW LOCKHEED SMP583 SRM, CH. 51-60 & 51-70. NR# 1001155297.SDR LR7A2024081603438Attach Angle · corrodedDURING SCHEDULED C-15 CHECK UNDER JOB CARD HC5314, FOUND PORK CHOP ATTACH ANGLE AND FASTENER ON RH CABIN UNDER CHINE CAP CORRODED AT FS577, RBL60, WL136. / REPAIR BY REPLACEMENT ACCOMPLISHED IAW LOCKHEED SMP583 SRM, CH. 51-60 & 51-70. NR# 1001134004.SDR LR7A2024081603428Attach Fitting · corrodedDURING SCHEDULED C-15 CHECK UNDER JOB CARD HC5317, FOUND RH FUSELAGE ATTACH RING CORRODED AT FS345.0E, RBL40, WL256. / REPAIR BY REPLACEMENT ACCOMPLISHED IAW LOCKHEED SMP583 SRM, CH. 51-60 & 51-70. NR# 1001132993. / PSE# 53-40-07, AD 2012-06-09SDR FDEA202408161138Fitting · crackedMAIN DECK CARGO DOOR - ACTUATOR FR23-FR24 FWD AND AFT LUG BEARING FITTINGS FOUND CRACKS COMPLIED WITH EA 6-5230-T0380237 REPLACED THE MAIN DECK CARGO DOOR ACTUATOR FR23- FR24 CRACKED FWD AND AFT LUG BEARING FITTINGS, TITLE: DOORS - CARGO DOOR/HYD SYS - MASDR DALA2024082308407Attach Angle · cracked(LOG 0516148) RH BS 663 VAPOR BARRIER UPPER ATTACH ANGLE CRACKED. REMOVED, FABRICATED -1 REPLACEMENT ANGLE P/N 2024T3#0,063 LOT. 5145130-1, -2 SPLICE ANGLE P/N 2024T3# 0,071 LOT 5157711-1 AND INSTALLED PER B737 SRM 57-10-10-2R PROCEDURE 5 AND SRM 5-40-02-0G. RSDR SWAA2024092424888Structure · crackedCRACK INNER CHORD LOCATED BS 294.5 PLUS 8.5 INCHES; LBL 55 FWD GALLEY AND LAV 2024-512212<[01] REPLACED INNER CHORD LOCATED BS 270 TO BS 360 AND LBL 56 FWD GALLEY AREA IAW B737-800 SRM 51-40-02; DWG: 141A8110; REV: A; SHEET: 9 AND DWG: 141A8110; REV: -; SHEET:SDR AALA202408195635Fitting · wornAIRCRAFT IN BASE MAINTENANCE: AFT AVIONIC COMPARTMENT RACK 80VU LEFT HAND LATERAL FITTING WORN BETWEEN FR 23 AND FR 24 AT S32L. REPLACED LEFT HAND LATERAL FITTING PER EA 356990.SDR AALA202408192503Fitting · wornAIRCRAFT IN BASE MAINTENANCE: AFT AVIONIC COMPARTMENT RACK 80VU RIGHT HAND LATERAL FITTING WORN BETWEEN FR 23 AND FR 24 AT S32R. REPLACED RIGHT HAND LATERAL FITTING PER EA 356990.SDR DALA2024081308089Attach Angle · cracked(LOG 0498536) CRACKS ON LH ATTACH ANGLE AT THE DRAIN SLOT STA 663 BTW LBL 25-45 AT LH VERTICAL PRESSURE DECK WEB. ANGLE AT THE DRAIN SLOT STA 663 BTW LBL 25-45 AT LH VERTICAL PRESSURE DECK WEB WAS REPAIRED PERMANENTLY PER B737-800 SRM 57-10-10-2R PROCEDURE 6. SDR SWAA2024092324544Fitting · corrodedCORROSION ON FITTING LOCATED BS 312 LBL 53 WL 208.1 AT FWD GALLEY AREA 2024-504154<[01] REPLACED LOCATED BS 312 LBL 53 WL 208.1 AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02 SRM 51-10-02 ITEM 9 AND DWG 141A5220 REV.-;[02] CORRECTED STEP 1<BR>REPLACED FITTING LOSDR AALA202408141367Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED INTERCOSTAL FITTING AT FR 16 LEFT AND DOOR STOP FITTING #7. REPLACED INTERCOSTAL FITTING PER SRM 51-72-11.SDR IPXA2024081597930Fitting · corrodedFOUND MAIN DECK FLOOR SUPPORT FITTING PLATE CORROSION AT 1720 RBL 18 (REPLACE). FABRICATE PARTS (P/N:457U1042-8) PER BOEING DWG NO:457U1042 SH 2 REV."A";PL REV."G"; PSDL REV."-" AND ORIGINAL PART AS A SAMPLE I.A.W GMM-MTX CH 9.08 REV: 7B REQUIREMENT. I.A.W AMSDR SWAA2024092024506Stringer Clip · crackedCRACK ON TIE CLIP LOCATED BS 277 AT LEVEL STR 10R AT FWD GALLEY AREA 2024-504075<[01] REPLACED TIE CLIP LOCATED BS 277 AT LEVEL STR 10R AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02-0G-0;SRM 51-10-02-0G-0 ITEM 9 AND DWG 141A1110 REV - SEE INDIVIDUAL SING-OFFS BSDR SWAA2024082023740Nut Plate · debondedAFT CARGO LH TRANSITION ANGLE MISSING 3 BONDED NUTPLAES STA 767 TO STA 787; LBL 21<[01] INSTALLED 3 BONDED NUTPLATES ON AFT CARGO LT TRANSITION ANGLE FROM STA 767 TO 787; LBL 21 IAW SRM 51-40-10. DATE AUGUST 8;2024 1:05AM CENTRAL TIME. CURE TIME APPROXIMATELY SDR AALA202408169291Stringer Clip · crackedAIRCRAFT IN BASE MAINTENANCE; CRACK IN FORWARD CARGO COMPARTMENT STRINGER CLIP AT STA 500I, RBL 26. REPLACED CLIP PER AARD 51-00-05.SDR IXXA2024080816Nut Plate · corrodedNUT PLATE STRAP STA 544-566 BL 35L-34L CORRODEDSDR IXXA2024080812Bracket · corrodedFOUND DURING REMOVAL, WEB TO CHORD STIFFENER AT FLC STA 566 ELONGATED HOLE AND CORRODED.SDR SWAA2024082023735Nut Plate · debondedAFT CARGO RH TRANSITION ANGLE MISSING BONDED NUTPLAES STA 727 TO STA 787; RBL 21. (MARKED). AFT CARGO RH TRANSITION ANGLE MISSING BONDED NUTPLAES STA 727 TO STA 787 RBL 21. (MARKED).<[01] INSTALLED 28 BONDED NUTPLATES ON AFT CARGO RAT TRANSITION ANGLE FROM STASDR IPXA2024080916678Fitting · corroded*SDR FILED OPEN* FAULT - FOUND MAIN DECK FLOOR FITTING PLATE WORN AT STA 651 LBL 90. (REPLACE) OK TO WORKSDR UIEA2024072600752Fitting · crackedSTA 1000 INTERCOSTAL LUG FITTING LBL 11.33 FOUND CRACK(<P>INTERCOSTAL LUG FITTING REPLACED AS PER ATLAS AIR EO 4453C024 REV 4 PART 3 STEP 3 CONDITION 6. NO FURTHER DEFECTS NOTED</P>)SDR IXXA20240806005Fitting · damagedFS 522 COMMON TO CORD & WEB IS DOUBLE DRILLED AND IS POTTEDSDR 2024FA0000563Attach Fitting · gougedWHILE ACCOMPLISHING FAA AD 2022-15-01, FOUND GOUGES ON HOLE #10SDR SWAA2024082822282Stringer Clip · crackedFWD CARGO COMPARTMENT R/H FLOOR STRUCTURE STRINGER CLIP CRACKED @ FASTENER HOLE BS 500H S-26R<[01] REMOVED AND REPLACED CLIP WITH NEW PN:143A7502U154 PO: 1098036.1 IAW B737-800 SRM 51-40-02;[02] VERIFIED REMOVED AND REPLACED CLIP WITH NEW PN:143A7502U154 PO: 1SDR SWAA2024090521602Attach Angle · crackedCRACKED INTERCOSTAL ATTACH ANGLE BS400 RBL25 WL154. FWD CARGO BAY<[01] REMOVED AND REPLACED INTERCOSTAL ATTACH ANGLE BS400 RBL25 WL154. P/N 143A7502-154 IAW SRM 51-40-02 AND DWG 143A7505.;[02] VERIFIED CORRECTIVE ACTION STEP 1. TASK CARD COMPLETE.SDR IPXA2024081935346Intercostal · corrodedT-CHORD LH BTW STA 1037-1060 LBL 37 SHOWS CORROSION MARKED WITH N. 4. INSTALLED T-CHORD L/H BTW STA1037-1060 LBL 37, NUT PLATE P/N:BACN11P3A5C BATCH:0004289211, COLLAR P/N:BACC30M6 BATCH:0004295539, HI-LOK P/N:BACB30MY6K4 BATCH:0004309178, HI-LOK P/N:BACB30NW6SDR IPXA2024081934171Tee Angle · corrodedT-CHORD LH STA 1037 SHOWS CORROSION MARKED WITH NUMBER 1. INSTALLED NEW T- CHORD IAW SRM 51-40-02 P/N MS20470AD6-7 BATCH 0004278691 P/N BACB30NX6K5 BATCH 0004307735 P/N BACB30MY6K11 BATCH 000429025 P/N BACB30MY6K4 BATCH 0004309178 P/N BACN11P3B4C BATCH 0004250SDR IPXA2024081935065Tee Fitting · corrodedFAULT: STR ZONE 100, T-CHORD LH STA 1042 BTW LBL 20 TO LBL 37 MARKED N. 3. NSTALLED T-CHORD L/H STA 1042 BTW LBL 20 TO LBL 37, NUT PLATE P/N:BACN11P3A5C BATCH:0004289211, COLLAR P/N:BACC30M6 BATCH:0004295539, HI-LOK P/N:BACB30NW6K5 BATCH:0004297257 IAW SRM 51SDR IPXA2024081934243Floor Support · corrodedT-CHORD LH BTW STA 1037-1060 LBL 20 SHOWS CORROSION. MARKED W 2. INSTALLED T-CHORD L/H BTW STA1037-1060 LBL 20, IAW SRM 51-40-02.SDR DALA2024080207722Web · crackedSHIP 3128 REAR FUSELAGE, FR 68 WEB JOINT TO DOOR FRAME AFT FACE, STR8R, CRACKS. CORRECTIVE ACTION: REPAIRED PER ER/A 615563-14AD. (0478818)SDR DALA2024080207721Web · crackedSHIP 3128 REAR FUSELAGE, FR 68 WEB JOINT TO DOOR FRAME AFT F ACE, STR8R, CRACKS. CORRECTIVE AQCTION: REPAIRED PER ER/A 615563-14AD. (0478808)SDR SWAA2024090935607Bracket · crackedCRACK BRACKET ANGLE LOCATED UPPER FUSELAGE AT STA 1016 AT VERTICAL STABILIZER 2024-473131<[01] REPLACED BRACKET ANGLE AND FASTENERS LOCATED UPPER FUSELAGE AT STA 1016 AT VERTICAL STABILIZER IAW B737-700 SRM 51-10-02 ITEM 9; SRM 51-40-02 AND DWG 176A7101; SHEETSDR IPXA2024081409475Tee Fitting · corrodedT-CHORD STA 1200 VERTICAL SHOWS EXFOLIATED CORROSION. INSTALLED OUTER CHORD AT STA 1200 VERTICAL, R/H SIDE IAW B757-200 SRM 51-40-02.SDR IPXA2024081409557Tee Fitting · corrodedT-CHORD STA 1180- 1240 RH SHOWS EXFOLIATED CORROSION. (TOP OF PANEL 198KR). INSTALLED T-CHORD AT STA 1180- 1240 RH IAW B757-200, SRM 51-40-02.SDR IPXA2024081011911Tee Angle · corrodedT-CHORD STA 1040-1060 LBL 67 LH SHOWS EXFOLIATED CORROSION. INSTALLED T-CHORD STA 1040-1060 LBL 67, IAW SRM 51-40-02.SDR IPXA2024081112045Tee Angle · corrodedT-CHORD STA 1040-1060 RBL 64 LH SHOWS EXFOLIATED CORROSION. INSTALLED T-CHORD STA 1040-1060 RBL 64, IAW SRM 51-40-02.SDR IPXA2024081411252Tee Angle · corrodedSTR ZONE 100, T-CHORD STA 1180-1240 LH SHOWS EXFOLIATED CORROSION. TOP OF HYDRAULIC BAY. INSTALLED T-CHORD IN STA 1180-1240 L/H IAW SRM 51-40-02SDR DALA2024080507772Attach Angle · corroded(LOG 0478694) CORROSION ON ATTACHMENT TO STRINGER S-27R AT STA 1016 AND WL190. REMOVED AND REPLACED FITTING P/N 147A1116-42 ATTACHMENT TO STRINGER 27RH AT STA 1016 IAW B737-800 SRM 51-40-02-0G AND DWG 147A0070.SDR SWIA202409160828Attach Angle · corrodedCLEAT ATTACHED TO INTERCOASTAL 20R AND FRAME FS333 PART# SH670-32014-1 IS CORRODED. (C-CHECK RO 9/15/2024) CLEAT ATTACHED TO INTERCOASTAL 20R AND FRAME FS333 IS CORRODED ON MORE THAN ONE ELEMENT AND AROUND FASTENER HOLES AND IS OUT OF LIMITS REF CRJ900SDR SWIA202406160827Attach Angle · corrodedCLEAT ATTACHED TO INTERCOASTAL 20R AND FRAME FS310 PART# SH670-32046-3 IS CORRODED. (C-CHECK RO 9/15/2024) (C-CHECK RO 9/15/2024) CLEAT ATTACHED TO INTERCOASTAL 20R AND FRAME FS310 IS CORRODED ON MORE THAN ONE ELEMENT AND AROUND FASTENER HOLES SDR SWIA20240916729Attach Angle · corrodedCLEAT ATTACHED TO INTERCOASTAL 20R AND FRAME FS349 PART# SH670-32045-1 IS CORRODED. (C-CHECK RO 9/15/2024) CLEAT ATTACHED TO INTERCOASTAL 20R AND FRAME FS349 IS CORRODED ON MORE THAN ONE ELEMENT AND AROUND FASTENER HOLES AND IS OUT OF LIMITS REF CRJ900 SDR HNAA2024091100754Fitting · cracked53-2143 RF1, BOX FITTING CRACKED BTW FR61-62 STR4-5R. RAR FITTING IAW SRM 51-40-02SDR HNAA2024091100751Fitting · cracked53-2143 FR1, BOX FITTING CRACKED AT FR61-62 STR4-5R. RAR FITTING IAW SRM 51-40-02SDR SWAA2024082819423Stringer Clip · crackedFWD PIT RH FLOOR STUCTURE; STRINGER CLIP CRACKED AT THE FASTENER HOLES AT BS 500I AT STRINGER S-26R.<[01] REMOVED AND REPLACED FWD PIT RH FLOOR STUCTURE; STRINGER CLIP AT BS 500I AT STRINGER S-26R WITH NEW PN:143A1010-48 PO: 1097927.3 IAW B737-800 SRM 51-40-02SDR UIEA2024072100708Attach Angle · crackedFX - RH AIRCON BAY STA 1230 CENTER TANK LWR ATT CHORD CRACK AT MOST O/B AREA ( RBL 104" )(<P>FX - RH AIRCON BAY STA 1230 CENTER TANK LWR ATT CHORD REPAIRED IAW RI-57-00-16986 REV A. NO FURTHER DEFECTS NOTED</P>)
Back to JASC 5340