JASC 5340
Service difficulty reports · 22,389
Reports filed under 5340 · Fuselage Main, Attach Fittings, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5340' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5340' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR JR2R20250714663Attach Angle · dentedFRAME 16, RT FLOOR ATTACH ANGLE IS CORRODED OUT OF LIMITS. REPLACEDSDR JR2R20250714665Attach Angle · corrodedFRAME 17, RH FLOOR ATTACH ANGLE IS CORRODED OUT OF LIMITS. REPLACEDSDR SWIA2026071377741Attach Angle · corrodedATTACH ANGLE, STRINGER 26L, FRAME BS 364 WAS CORRODED. REMOVED AND REPLACED THE ATTACH ANGLE, IAW SRM 51-42-06-001-001-A01, REV 38, AND DWG SH670-32050, REV J. COMPLIED WITH ALL STEPS OF TASK CARD 51-900-1002-SKY.SDR AALA202607216819Stringer Clip · crackedAIRCRAFT IN BASE MAINTENANCE: STRINGER CLIP LH S25R 500I CRACKED. MAINTENANCE INSTALLED NEW CLIP IAW AARD 51-00-05-1.SDR HNAA2026081400704Attach Bracket · crackedCARGO DOOR FWD LIFTING AND LOWERING MECHANISM FWD ATTACHMENT BRACKET HAS A CRACK. RAR CARGO DOOR FWD LIFTING AND LOWERING MECHANISM FWD ATTACHMENT BRACKET IAW EMB 145 SRM 51-40-02.SDR SWAA2026081915057Attach Angle · crackedRIGHT A/C BAY, BS 663, RBL 9 HAD A CRACK IN THE VAPOR BARRIER VERTICAL ATTACH ANGLE, REPAIRS COMPLETED ON EA M-157-01143.SDR SWAA2026081969600Attach Angle · crackedLEFT A/C BAY, BS 663, LBL 9 HAD A CRACK IN THE VAPOR BARRIER VERTICAL ATTACH ANGLE. REPAIRS COMPLETED ON EA M-157-01142.SDR HNAA2026081400698Bracket · crackedLEFT LOWER OVERWING BRACKET #5 IS CRACKED AT THE AFT END. ACCOMPLISHED SPLICE REPAIR FOR LH LOWER OVERWING BRACKET #5 AT THE AFT END IAW EMB 145 SRM 57-20-01-RE ITEM 3, FIG 203, 204, AND EO1-57-26-0360.SDR VNAA202609010021Fitting · corrodedCORROSION FLOOR FITTING IN FWD ACCESS 104 (1EA) ON GALLEY 1. THE FLOOR FITTING IN FWD ACCESS 104 (1EA) ON GALLEY 1 WAS INSTALLED PER CMM 25-32-02, REV 7.SDR SWAA2026073165319Attach Angle · crackedLEFT VAPOR BARRIER UPPER ATTACH ANGLE IS CRACKED AT APPROXIMATLY LBL 11, BS 663, WL 165. REPAIRED THE LT VAPOR BARRIER UPPER ATTACH ANGLE BS 663 LBL 11 IAW EA M-26-157-01142.SDR ASAA2026070667514Stringer Clip · crackedSTRINGER CLIP IS CRACKED AT STA 500D STR 26R. GROUNDED - YES. REMOVED & REPLACED THE STRINGER CLIP STA 500D, STR 26R IAW SRM 51-40-02-0G-0.SDR AALA202607215879Stringer Clip · crackedAIRCRAFT IN BASE MAINTENANCE: GVI - FWD CARGO FLOOR STRUCTURE - RH STRINGER CLIP CRACKED STA 500I RBL 26. MSINTENANCE REMOVE AND REPLACE RH STRINGER CLIP STA 500I RBL 26 IAW SRM 51-40-02.SDR AALA202607211224Stringer Clip · damagedAIRCRAFT IN BASE MAINTENANCE: STRINGER CLIP AT STA 887, STRINGER 27L IS DAMAGED. MAINTENANCE INSTALLED NEW SERVICEABLE STRINGER CLIP IAW AARD 53-00-01-6.SDR SWAA2026072861022Tie Clip · crackedCRACKED TIE CLIP, BS 277, STR 10R. REPLACED THE TIE CLIP IAW SRM 51-10-02, ITEM 9, SRM 51-40-02, AND DWG 141A1110, SHEET 55, REV -.SDR SWAA2026072772390Attach Angle · crackedBS 663 RBL 31 VAPOR BARRIER ATTACH ANGLE IS CRACKED. REPAIRED PER M-26-157-01481.SDR SWAA2026072742484Attach Angle · crackedBS 663, LBL 31.5 VAPOR BARRIER ATTACH ANGLE IS CRACKED. REPAIRED PER M-26-157-01480 .SDR AALA202607108142Attach Angle · crackedAIRCRAFT IN BASE MAINTENANCE: UPON REMOVAL OF RH HEAT EXCHANGER FOUND RT ECS BAY VAPOR BARRIER ATTACH ANGLE CRACKED AT IB SIDE. MAINTENANCE REMOVED CRACKED ANGLE SECTION AND INSTALLED NEW ANGLE AND SPICE IAW SRM 57-10-10-2R-F REPAIR 5.SDR REXA2026082601733Fitting · corrodedCORROSION FLOOR FITTING IN FWD ACCESS 205 (1EA) ON GALLEY 2 FLOOR FITTING IN FWD ACCESS 205 (1EA) ON GALLEY 2 WAS REPLACED IAW CMM 25-32-84 REV. 9 DATE JUN 06/24.SDR CALA2026062917420Attach Angle · cracked(AC BAY) WING CENTER SECTION REAR SPAR VAPORT BARRIER ATTACH ANGLE AT STA 663 RBL 15 CRACKED AT FASTENER HOLE. INSTALLED REAR SPAR VAPOR BARRIER ATTACH ANGLE AT BS 663.75 FROM RBL 5 TO RBL 70 PER REF SRM 51-40-02-0G-0 AND DWG 111A1000,SDR SWAA2026071584054Attach Angle · crackedLEFT BS 663, UPPER ATTACH ANGLE IS CRACKED ON VAPOR BARRIER LBL 8 AND LBL 34 WL 167.68. REMOVED, REPLACED, AND INSTALLED A NEW BS 663 LT UPPER ATTACH ANGLE LBL 4 TO LBL 65 IAW SRM 51-40-02-0G-0, DWG 111A1000, REV B, DWG 111A1001 REV B, AND DWG 111A7000 REV SDR SWAA2026071546017Attach Angle · crackedRT BS 663 UPPER ATTACH ANGLE IS CRACKED ON VAPOR BARRIER RBL 8 AND RBL 34 WL 167.68. REMOVED, REPLACED, AND INSTALLED A NEW BS 663 RT UPPER ATTACH ANGLE RBL 4 TO RBL 65 IAW SRM 51-40-02-0G-0, DWG 111A1000, REV B, DWG 111A1001, REV B, AND DWG 111A7000, REV -.SDR CALA2026062917397Attach Angle · cracked(AC BAY) CENTER SECTION REAR SPAR VAPOR BARRIER ATTACH ANGLE AT BS 663 LBL 15 CRACKED AT FASTENER HOLE. 5 REMOVED DAMAGED SECTION AND INSTALLED REPAIR AT REAR SPAR VAPOR BARRIER ATTACH ANGLE AT BS 663.75 FROM LBL 5 TO LBL 25 IAW SRM 57-10-10-2R-5.SDR SWAA2026072790339Attach Angle · crackedBS 663, RBL 9, VAPOR BARRIER ATTACH ANGLE CRACKED. REMOVED AND REPLACED PER EA-GENERAL. REPAIRED IAW M-26-157-01481.SDR SWAA2026072799368Attach Angle · crackedBS 663, LBL 35, VAPOR BARRIER ATTACH ANGLE CRACKED, REMOVED AND REPLACED PER EA REPAIRED PER M-26-157-01480.SDR SWAA2026072742569Attach Angle · crackedBS 663, LBL 9 VAPOR BARRIER ATTACH ANGLE CRACKED. REMOVED AND REPLACED IAW EA. REPAIRED IAW M-26-157-01480.SDR SWAA2026072782625Attach Angle · crackedBS 663, RBL 35, VAPOR BARRIER ATTACH ANGLE CRACKED. REMOVED AND REPLACED IAW EA, REPAIRED IAW M-26-157-01481SDR CALA2026062617363Attach Angle · crackedFOUND CRACK AT LBL 7 CENTER SECTION REAR SPAR VAPOR BARRIER ANGLE. INSTALLED REAR SPAR VAPOR BARRIER ATTACH ANGLE AT BS 663.75 FROM LBL 5 TO LBL 70 IAW SRM 51-40-02-0G-0, AND DWG 111A1000.SDR VNAA20260623018Bracket · corrodedL/H WHEEL WELL HYD LINE BRACKET IS CORRODED BETWEEN W.S. 0.00 TO W.S. 29.00. REMOVED AND INSTALLED NEW SERVICEABLE HYDRAULIC LINE BRACKET IN LT WHEEL WELL BETWEEN W.S. 0.00 TO W.S 29.00 IAW SRM 51-41-02-001-001-A01 AND AMM 20-22-00-910-801-A01.SDR IPXA2026082091705Nut Plate · corrodedAFT OF BULK CARGO COMPARTMENT, DECK PLATE FLOOR STRUCTURE SUPPORT ANGLE ASSY HAS CORROSION ON NUT PLATE STRAP APPROX AT BS 1715, RBL 24. INSTALLED ONE NUT PLATE STRAP ASSY AT STA 1715 RBL 24 IAW SRM 51-40-02-0G-0. REQUEST OK TO RE-INSTALL PRESSURE DECK PLATE SDR IPXA2026070292708Bracket · corrodedRH MLG W/W FWD SEAL RETAINER HAS (3EA) CRACKED BRACKETS. REMOVAL OF CORNER SEAL RETAINER AND REMOVED SEAL RETAINER SEAL AND SUPPORT CHANNEL "(BRAKETS 3EA)" IAW B757-200 SRM 51-40-02. INSTALLED SEAL RETAINER ON RH MLG W/W IAW B757-200 SRM 51-40-02-0G.SDR IPXA2026062791791Nut Plate · corrodedAFT OF BULK CARGO COMPARTMENT, DECK PLATE FLOOR STRUCTURE SUPPORT ANGLE ASSY HAS CORROSION ON NUT PLATE STRAP APPROX AT BS 1715, LBL 36. INSTALLED NUT PLATE STRAP ASSY ON AFT OF BULK CARGO COMPARMENT DECK PLATE FLOOR STRUCTURE APPROX AT BS 1715. LBL 36. IAW SSDR LR7A2026061903843Fitting · crackedDURING SCHEDULED C-3 CHECK UNDER JOB CARD HC5315, FOUND FS 814 LT LOWER ATTACHMENT TEE FITTING CRACKED AT LBL 62, WL 170. REPAIR BY REPLACEMENT ACCOMPLISHED IAW SRM 51-60 & 51-70.SDR LR7A2026061903842Fitting · crackedDURING SCHEDULED C-3 CHECK UNDER JOB CARD HC5313, FOUND RT CARGO FLOOR END FITTING UNDER CHINE CAP CRACKED AT FS 717, RBL 61, WL 140. REPAIR BY REPLACEMENT ACCOMPLISHED IAW SRM 51-60 & 51-70.SDR LR7A2026061903841Fitting · crackedDURING SCHEDULED C-3 CHECK UNDER JOB CARD HC5313, FOUND LT CARGO FLOOR END FITTING UNDER CHINE CAP CRACKED AT FS 717, LBL 61, WL 140. REPAIR BY REPLACEMENT ACCOMPLISHED IAW SRM 51-60 & 51-70.SDR SWAA2026072159781Attach Angle · crackedDURING HOLE PROBE INSPECTION OF STA 663 VAPOR BARRIER FOUND A CRACK AT A FASTENER HOLE LOCATION LBL 31.5" (JUST INBD OF EXPANSION JOINT/SEAL IN VAPOR BARRIER) REPAIRED VAPOR BARRIER ATTACH ANGLE PER EA M26-157-01480 .SDR SWAA2026072125817Attach Angle · crackedDURING HOLE PROBE INSPECTION OF BS 663 VAPOR BARRIER FOUND A CRACK AT A FASTENER HOLE LOCATION RBL 31.5, (JUST INBD OF EXPANSION JOINT/SEAL IN VAPOR BARRIER) REPAIRED VAPOR BARRIER ATTACH ANGLE IAW EA M-26-157-01481.SDR CALA2026062217211Attach Angle · crackedCRACK AT VAPOR BARRIER ATTACH ANGEL STA 663 LBL15 LEFT AIR CONDITION BAY. ACCOMPLISHED REPAIR OF LEFT SIDE VAPOR VARRIER ATTACH ANGLE AT BS 663 LBL 15 IAW 57-10-10-2R-5.SDR DALA2026061803642Fitting · crackedCABIN FLOOR STRUCTURE FITTING CRACK AT C80, Y1447.8. REPLACED FITTING PER A330 SRM 51-72-11. (1653239) AIRCRAFT WAS GROUNDED.SDR IPXA2026061695676Nut Plate · corrodedAFT OF BULK CARGO COMPARTMENT SUPPORT ANGLE, NUT PLATE STRAP HAS CORROSION APPROX AT BS 1715, BTW BL 0 AND RBL 9.SDR SWAA2026062912728Attach Angle · crackedCENTER SECTION REAR SPAR VAPOR BARRIER ATTACH ANGLE HAS A 1.1 INCH VERTICAL CRACK THROUGH THE FASTENER AT BS 661.95, LBL 6.14+3.4. C/W M-26-157-01480 REPAIR OF LT BS 663 VAPOR BARRIER UPPER ATTACH ANGLE IAW TASK TTG8Q01CRT4G.SDR SWAA2026062913127Attach Angle · crackedCENTER SECTION REAR SPAR VAPOR BARRIER ATTACH ANGLE HAS A 0.5 INCH VERTICAL CRACK THROUGH THE FASTENER AT BS 661.95, RBL 34.80. C/W M-26-157-01481 REPAIR OF RH BS 663 VAPOR BARRIER UPPER ATTACH ANGLE IAW TASK TTG8Q01CRTLX.SDR SWAA2026062913126Attach Angle · crackedCENTER SECTION REAR SPAR VAPOR BARRIER ATTACH ANGLE HAS A .6 INCH VERTICAL CRACK THROUGH THE FASTENER AT BS 661.95, LBL 34.79. C/W M-26-157-01480 REPAIR OF LT BS 663 VAPOR BARRIER UPPER ATTACH ANGLE IAW TASK TTG8Q01CRU7S.SDR LR7A2026061603830Fitting · crackedDURING SCHEDULED B-2 CHECK UNDER JOB CARD HB5302, FOUND FS 858 BULKHEAD FITTING CRACKED AT LBL66, WL190. / REPAIR BY REPLACEMENT ACCOMPLISHED IAW LOCKHEED SMP583 SRM, CH. 51-60 & 51-70. NR# 1001387284.SDR SWAA2026061512287Attach Angle · crackedBS 663 LBL 35 VAPOR BARRIER ATTACH ANGLE HAS EVIDENCE OF A CRACK (JUST OUTBD OF EXPANSION SEAL) VERIFIED CRACK AT STATION 663 LBL 35" VAPOR BARRIER ATTACH ANGLE REF HFEC 737 NDT PART 6 51-00-00 PROCEDURE 23. REPAIRED THE ATTACH ANGLE IAW EA M-26-157-01480.SDR SWAA2026072192731Attach Angle · crackedSTA 663 RBL 35" VAPOR BARRIER ATTACH ANGLE HAS A CRACK (JUST OUTBD OF EXPANSION SEAL) REPAIRED ANGLE PER EA M-26-157-01481 C/W C/W INSPECTION REPAIRED ANGLE PER EA M-26-157-01481SDR U2RA2026072100047Tension Tie · crackedCRACK FOUND DURING OPEN HOLE INSPECTION AT L/H STA1180 TENSION TIE FWD CHANNEL. PERFORMED CLASS B REPAIR IAW SRM 53-40-30-2R-2.SDR U2RA2026071900038Tension Tie · crackedOPEN HOLE NDI INSPECTION FOUND DEFECT SIGNALS WHILE PERFORMING STA 1140 R/H TENSION TIE. REPAIR COMPLETED PER BCS MESSAGE 06370241 INSPECTION THRESHOLD 20,811 TOTAL FLIGHT CYCLES.SDR SWAA2026070111069Attach Angle · crackedRIGHT VAPOR BARRIER ATTACH ANGLE CRACKED AT BS 663, RBL 25. REMOVED AND REPLACED RH VAPOR BARRIER UPPER ATTACH ANGLE AT BS 663 IAW SRM 51-40-02 AND BOEING DWG 111A1000 SHEET 45 REV:A AND BOEING DWG 111A1000 SHEET 153 REV-.SDR SWIA2026061077035Attach Angle · crackedBS 280 RT LOWER WEB ATTACH ANGLE CRACKED. REMOVED AND INSTALLED NEW BS 280 RT LOWER WEB ATTACH ANGLE IAW SRM 51-42-06-001-001-A01 AND DWG CC670-34010, REV K AND COMPLIED WITH SKYWEST TASKCARD 51-900-1002-SKY.SDR SWAA2026063011115Stringer Clip · crackedSTRINGER CLIP CRACKED AT BS 727F, S6L. THE STRINGER CLIP WAS REMOVED AND REPLACED IAW SRM 51-40-02-0G-0, AND DWG 146A1121, REV-.
Back to JASC 5340