What was found
DURING HOLE PROBE INSPECTION OF STA 663 VAPOR BARRIER FOUND A CRACK AT A FASTENER HOLE LOCATION LBL 31.5" (JUST INBD OF EXPANSION JOINT/SEAL IN VAPOR BARRIER) REPAIRED VAPOR BARRIER ATTACH ANGLE PER EA M26-157-01480 .
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.