JASC 5340
Service difficulty reports · 22,411
Reports filed under 5340 · Fuselage Main, Attach Fittings, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5340' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5340' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA0300652Attach Angle · gougedINSPECTION FOUND A GOUGE ON VERTICAL ATTACH ANGLE ON RT SIDE OF VERTICAL STRAP AT STA 1121. A NEW ANGLE WAS INSTALLED IAW ECRA 5380-01013.SDR UPS03841641Fitting · crackedINSPECTION TYPE: C1, STATION 680 LONG 6R END FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3779762 AND SRM 51-1-20D, 51-3-0.SDR UPS03841593Fitting · crackedINSPECTION TYPE: C1, STATION 680 LONG. 5L END FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG.3779762 AND SRM. 51-1-20D.SDR UPS03841640Fitting · corrodedINSPECTION TYPE: C1, BATHTUB FITTING IS CORRODED BEYOND LIMITS AT STA 320 BETWEEN LONG 33R-34R. REMOVED AND REPLACED FITTING IAW DWG 3755824 AND SRM 53-2-0 FIG 2D.SDR UPS03841630Fitting · crackedINSPECTION TYPE:C1 A-PIT RT CARGO TRACK SUPPORT FITTING IS CRACKED AT STATION 100 AT LONG. 34R REMOVED,FABRICATED AND REPLACED FITTING IAW 8110-3 APPROVED DATED 11/24/03 SAA SK 718-027 DATED11/21/03,UPS ENGINEERING FILE NUMBER DC8- 53-20379 DATED 11/25/03 AND SDR UPS03841623Fitting · crackedINSPECTION TYPE: C1, BATHTUB FITTING IS CRACKED AT STATION 320 BETWEEN LONG. 27L AND 28L. REMOVED AND REPLACED FITTING I.A.W. DWG. 3755822 AND SRM.53-2-0 FIG.2D.SDR UPS03841597Fitting · crackedINSPECTION TYPE: C1, A-PIT DOOR FWD. BUMPER SUPPORT FITTING IS CRACKED AT STA. 300 LONG. 27L. REMOVED AND REPLACED FITTING IAW DWG. 3754041 AND SRM. 51-1-20D.SDR GTIA031007Fitting · wornFTW - FOUND CABIN STATION 1309 LBL 34 - LBL 49 B/H L BRACKET WORN IN SEVERAL AREAS. UPON FURTHER EVALUATION, FOUND FITTING CRACKED AT STATION 1309 LBL 34. REMOVED FITTING. DRILLED AND LOCATED NEW FITTING. INSTALLED NEW FITTING. (M)SDR UPS03841595Fitting · crackedINSPECTION TYPE: C1, EXTERIOR FUSELAGE LOWER CENTER SECTION FRAME TO KEELBEAM FITTING IS CRACKED AT STATION 702 RT SIDE OF CENTERLINE. REMOVED AND REPLACED FITTING IAW DWG. 3753757 AND SRM. 51-1-20D.SDR UPS03841639Fitting · corrodedINSPECTION TYPE: C1, BATHTUB FITTING IS CORRODED BEYOND LIMITS AT STATION 1220 BETWEEN LONG 28L-29L. REMOVED AND REPLACED FITTING IAW DWG 3755842 AND SRM 53-2-0 FIG 2D.SDR UPS03841594Fitting · crackedINSPECTION TYPE: C1, STATION 1140 LONG. 35L FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG.3758497 AND SRM. 51-1-20D.SDR UPS03841588Fitting · corrodedINSPECTION TYPE: C1, BATHTUB FITTINGS ARE CORRODED BEYOND LIMITS BETWEEN LONG. 35L TO 35R AT STATION 1150. REMOVED AND REPLACED FITTINGS IAW DWG. 3755845 AND SRM. 51-1-20D.SDR UPS03841580Fitting · crackedINSPECTION TYPE: C1, BATHTUB FITTING IS CRACKED AT STATION 1230 BETWEEN LONG. 33R-34R. REMOVED AND REPLACED FITTING IAW DWG. 3755841 AND SRM. 51-1-20D.SDR UPS03841617Fitting · crackedINSPECTION TYPE:C1 LT WHEEL WELL OB FITTING UPPER STA. 902 IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG.3641004 AND SRM.53-2-0 FIG.8SDR C1HA200394044Fitting · corrodedRIGHT AFT LAV GUITAR FITTING BS 1140 HAS CORROSION.SDR SWAA032503Clip · crackedDURING SCHEDULED D CHECK, FOUND 13 EA STRINGER CLIPS CRACKED AT STR 10R, BS 480, BS 500, BS 500A, BS 500B, BS 500C, BS 520 AT STR 10L BS 480, BS 460, BS 500A, BS 500B, BS 500C AT STR 8R, BS 500D, BS 520. REMOVED AND REPLACED STRINGER CLIPS PER SRM.SDR SWAA032477Clip · crackedDURING SCHEDULED 1/2D CHECK, FOUND 3 EA STRINGER CLIPS CRACKED AT BS 737, STR 19R, BS 727B, STR 21R, AND BS 727A, STR 21R. REMOVED AND REPLACED CLIPS PER SRM.SDR CA031107017Lever · cracked(CAN) DURING 'C' CHECK OF THE WATER SYSTEM A MPI INSPECTION WAS COMPLETED ON THE WATERDOOR UPLOCK ACTUATING LEVER MOUNTING LUG. A CRACK WAS NOTED ON THE MOUNTING FLANGE. THE CRACK IS APPROXIMATELY .5000 INCH IN LENGTH. THE PART WILL BE REPLACED WITH A SERVICEASDR UPS03841557Fitting · crackedINSPECTION TYPE: C2 BATHTUB FITTING IS CRACKED AT STATION 270 BETWEEN LONG. 35L AND 36. REMOVED AND REPLACED FITTING I.A.W. DWG. 3755822 AND SRM. 53-2-0 FIG. 2DSDR SWAA032370Bracket · corrodedDURING SCHEDULED 1/2D CHECK, FOUND L1 DOOR EVACUATION SLIDE GIRT BAR FLOOR ATTACH BRACKETS CORRODED. REMOVED AND REPLACED BRACKETS PER SRM.SDR UPS03841493Fitting · crackedINSPECTION TYPE: C2, STATION 350 BETWEEN LONG 35L AND 36 BATHTUB FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3755822 AND SRM 51-1-20D.SDR UPS03841491Fitting · crackedINSPECTION TYPE: C2, STATION 300 BETWEEN LONGERON 31L-32L HAS A CRACKED BATHTUB FITTING. REMOVED AND REPLACED FITTING IAW DWG 3755826 AND SRM 51-1-20D, 53-2-0 FIG 2D.SDR UPS03841490Fitting · crackedINSPECTION TYPE: C2, STATION 270 LONG 32R BANANA FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3755827 AND SRM 51-1-20D.SDR UPS03841476Fitting · crackedINSPECTION TYPE: C2, STATION 305 AT LONG 33R NR 3 T-BOLT BACKUP FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3754023 AND SRM 51-1-20D.SDR UPS03841475Fitting · corrodedINSPECTION TYPE: C2, BATHTUB FITTING IS CORRODED BEYOND LIMITS AT STA 340 LONG 35R. REMOVED AND REPLACED FITTING IAW DWG 3755822 AND SRM 51-1-20D.SDR UPS03841496Fitting · corrodedINSPECTION TYPE: C2, STATION 1220 AT LONG 29L BATHTUB FITTING IS CORRODED BEYOND LIMITS. REMOVED AND REPLACED FITTING IAW DWG 3754842 AND SRM 51-1-20D, 53-2-0 FIG 2D.SDR UPS03841492Fitting · crackedINSPECTION TYPE: C2, RIGHT FUSELAGE FITTING IS CRACKED AT STA 925 AT RBL 68. REMOVED AND REPLACED FITTING IAW DWG 36491144 AND SRM 51-1-20D.SDR UPS03841558Fitting · crackedINSPECTION TYPE: C2, STATION 340 MAIN CARGO FLOORBEAM END FITTING IS CRACKED AT RT. SIDE RBL 67 APPROX. REMOVED AND REPLACED FITTING IAW DWG. 9754022 AND SRM. 51-1-20DSDR UPS03241526Fitting · crackedINSPECTION TYPE: C, TO REMOVE RT BS 930 FITTING, PARTIAL SHELF ATTACHING BS 930 TO 940 MUST BE REMOVED, ON REMOVAL OF PARTIAL SHELF AT STR 14 BS 930-940, 3 SUSPECT CRACKS WERE DETECTED ON MOST UPPER HORIZONTAL FLANGE (FWD SIDE) ON BS 940 FITTING. REPAIR CARRSDR UPS03841614Fitting · corrodedINSPECTION TYPE:C3 (C) PIT DOOR OUT LOWER SIDE WEB CORRODED NR 3 AND NR 6 (T) BOLT FITTING CORRODED. REMOVED (2) LATCHES. REMOVED CORROSION IAW DC8 SRM 51-1-8. AREA WITHIN LIMTS IAW DC8 SRM 53-2-0. PRIMED LONGERON AND INSTALLED FITTINGS IAW DC8 SRM 51-1-20DSDR ASAA0380679Fitting · corrodedOAK - FOUND 15K CHECK, FRAME TO CUSP FITTING IS CORRODED AT FS 1174. REPLACED FITTING PER SRM 51-10-4 AND 51-30-1. (M)SDR CA031106008Fitting · cracked(CAN) DURING ACCOMPLISHMENT OF AD CF97-07R2,THE WING TO FUSELAGE FITTINGS WERE BEING INSPECTED IAW SB 215-A476. DURING THE INSPECTION THE RT FORWARD OUTBOARD ANGLE OF THE WING TO FUSELAGE FITTING WAS FOUND CRACKED. THE AIRCRAFT WILL BE REPAIRED IAW MFG REPAIR SDR UPS03241527Fitting · crackedINSPECTION TYPE: C, RT 930 FITTING HS SUSPECT CRACK AT AFT O/B FLANGE AT FLOOR LEVEL. REPAIR & REPLACEMENT OF BS 930 FITTING & ASSOCIATED STURCTURAL ITEMS CARRIED OUT IAW SMRO EO 2003-055-001 UPS ENGINEERING FILE 727-53-20 130.SDR GTIA030814Fitting · corrodedFOUND MID PIT STATION 693 TEE FITTING CORRODED/ELONGATED HOLES. FABRICATED NEW T-FITTING. (M)SDR UPS03241538Fitting · crackedINSPECTION TYPE:C SUSPECT CRACK ON ACTUATOR FITTING I/B LUG I/B FACE BELOW BOLT HOLE AIRSTAIRS ACTUATOR. HFEC CONFIRMED CRACK. REMOVED AND REPLACED FITTING IAW SRM 51-30-02 AND DRAWING 65C13874. BOLT ALSO FOUND WORN, REPLACED IAW 52-62-71. OPS CHECKED SATISDR UPS03841442Fitting · crackedINSPECTION TYPE: C1, STA 1180 BATHTUB FITTING IS CRACKED BETWEEN LONG. 33R TO 34R. R & R FITTING IAW SRM. 53-2-0 FIG. 2D AND DWG. 3755841SDR GTIA030881Fitting · corrodedFTW - FOUND CABIN FLOOR SUPPORT CORRODED AT FS 160-200 48 INCHES RBL. FLOOR SUPPORT ATTACHMENTS 2 AT FS 165 AND 200 48 INCHES RBL OUT OF LIMITS. REMOVED FLOOR SUPPORT ATTACHMENTS TWO, LOCATED AND DRILLED NEW FITTINGS. INSTALLED FLOOR SUPPORT AT ATTACHMENTS SDR AT0700024Attach Fitting · crackedT-CLIP CRACKED AT STA 58-750 FRP. REPLACED T-CLIP AT STA 58.75 PER DWG 9911502 AND B717 SRM 51-41-01. MATERIAL USED 7075-0, 2 X 3 INCHES LONG. HEAT TREATED TO 7075-T6 AS PER 98 PMS 247 PS-01.SDR QXEA200301262Clip · damagedFRAME CLIP IS DAMAGED INBOARD END BEHIND NR 1 SEAT TRACK AT FRAME 291.400 FORWARD SIDE. REPAIRED IAW DHC-8 SRM 51-40-11.SDR QXEA200301254Stanchion · scratchedRIGHT HAND CARGO BAY STANCHION LUG HAS NICKS AND SCRATCHES .5 INCH FORWARD OF STACHION LUG ON NR 9 SEAT TRACK. REPAIRED IAW DHC-8 SRM 51-00-06, 51-20-36 AND RD 8-53-784.SDR QXEA200301252Stanchion · dentedLEFT HAND STANCHION LUG IS DAMAGED OR DENTED AT INBOARD FORWARD RADIUS OF LUG AT AFT END OF NR 6 SEAT TRACK. REPAIRED IAW DHC-8 SRM 51-00-06, 51-20-36 AND RD 8-53-784.SDR QXEA200301261Clip · damagedFRAME CLIP IS DAMAGED INBOARD END BEHIND NR 1 SEAT TRACK AT FRAME 312.350 FORWARD SIDE. REPAIRED IAW DHC-8 SRM 51-40-11.SDR SWAA032172Attach Fitting · looseDURING SCHEDULED C4 CHECK, FOUND FWD ENTRY DOOR EMERGENCY EVAC SLIDE BOTH FWD AND AFT GIRT BAR ATTACHMENT FITTINGS LOOSE. SECURED ATTACHMENT FITTINGS PER SRM.SDR 2004F00066Fitting · corrodedAT C-CHECK, FOUND FLOOR SUPPORT FITTING AT AFT CARGO COMPARTMENT FRAME 56, LBL 12 IS CORRODED AROUND 2 EACH FASTENER HOLES. REMOVED AND REPLACED FLOOR SUPPORT FITTING AT FRAME 56, LBL 12, IN AFT CARGO PIT. (M)SDR 2004F00065Fitting · corrodedAT C-CHECK, FOUND FLOOR SUPPORT FITTING AT AFT CARGO COMPARTMENT FRAME 56 BL 0 IS CORRODED AROUND 2 EACH FASTENER HOLES. REMOVED AND REPLACED FLOOR SUPPORT FITTING AT FRAME 56, BL 0 IN AFT CARGO PIT. (M)SDR QXEA200301198Clip · damagedFRAME CLIP IS DAMAGED AT INBOARD END BEHIND SEAT TRACK AT FRAME 270.500 FORWARD SIDE OF NR 1 SEAT TRACK. REPAIRED IAW DHC-8 SRM 51-40-11.SDR UPS03841443Fitting · crackedINSPECTION TYPE: C1, TORQUE BOX VERTICLE LEG SUPPORT FITTING IS CRACKED AT STA. 1220 LONG. 27R. REMOVED, FABRICATED AND REPLACED FITTING IAW DWG. 3754025,AND SRM. 51-1-20D,AND SRM. 51-3-0SDR UPS03841386Support Fitting · crackedINSPECTION TYPE: C1, TORQUE BOX VERTICLE LEG SUPPORT FITTING IS CRACKED AT STA. 340 LONG. 27R. REMOVED AND REPLACED FITTING IAW DWG 3754025, AND SRM. 51-1-20DSDR ABXA030390Fitting · crackedCRACKED LONGERON END FITTING STA. 756, LONGERON 29 LEFT. REPLACED LONGERON 29 LEFT END FITTING IAW DC-9 SRM.SDR SWAA032145Bracket · looseDURING SCHEDULED C1 CHECK, FOUND FWD ENTRY DOOR EMERGENCY EVAC SLIDE GIRT BAR FWD ATTACHMENT BRACKET LOOSE. SECURED BRACKET PER MM.
Back to JASC 5340