SDR UPS03840918Fitting · crackedINSPECTION TYPE: C, KEELBEAM TO FRAME FITTING IS CRACKED AT STA 702 LT SIDE OF KEELBEAM. REMOVED AND REPLACED FITTING IAW DWG 4750718 AND SRM 51-1-20D, 51-3-0.SDR DHL2003604765Attach Fitting · crackedMAIN CARGO COMPT FRAME FITTING CRACKED 4.500 AT STA 960.000 BETWEEN L-18L AND L-22L. PERFORMED MAJOR IAW SRM 53-1-0 PG 1, ATM PO201390, DWG 5646955. REMOVED CRACKED FITTING IAW SRM 51-1-20D PG 21. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. FABRICATSDR DHL2003604763Attach Fitting · corrodedMAIN CARGO COMPT T-FITTING ATTACHING NR 4 TRACK TO FLOORBEAM AT STA 1704.000 CORRODED. PERFORMED MAJOR REPAIR IAW SRM 53-1-0 PG 1 ATM NR P0201387, DWG 5755032. REMOVED CORRODED FITTING IAW SRM 51-3-0 PG 1. REMOVED CORROSION IAW SRM 51-1-8 PG 17-18. FOUND SDR DHL2003604764Fitting · corrodedFWD CARGO COMPT END FITTING AT STA 70.000, L-27L CORRODED. PERFORMED MAJOR REPAIR IAW SRM 53-1-0 PG 1, SRM 51-1-20D PG 9, 21, SRM 51-1-21 PG 1. REMOVED CORROSION FROM END FITTING IAW SRM 51-1-8 PG 17-18. FOUND OUT OF ALLOWABLE LIMITS IAW SRM 53-2-0 PG 21. SDR CALA0300292Fitting · corrodedINSPECTION FOUND LEFT O/B SUPPORT FITTING CORRODED BETWEEN STA 1006 AND 1016, LBL 36. THE SUPPORT FITTING WAS REMOVED AND REPLACED IAW SRM 51-10-02.SDR CALA0300290Fitting · corrodedINSPECTION FOUND FITTING O/B OF STRINGER 18R AT STA 1016 CORRODED. THE FITTING WAS REMOVED AND REPLACED IAW SRM 51-10-02.SDR DHL2003604695Attach Fitting · crackedLT MLG W/W FITTING ATTACHING LONGERON 24L AT STA. 940.000 WITH 5.000 CRACK IN IT. PERORMED MAJOR REPAIR IAW SRM 53-2-0 FIG.8. REMOVED DAMAGED FITTING IAW SRM 51-1-20D PG.21. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. CUT OUT NEW FITTING SRM 53-2-0 FIG.SDR DHL2003604713Fitting · crackedMAIN CARGO COMPT FITTING CRACKED AT STA 1170.000, L-21R. PERFORMED MAJOR REPAIR IAW SRM 53-1-0 PG 1, SRM 51-1-20D PG 9, 21. REMOVED CRACKED FITTING IAW SRM 51-1-20D PG 21. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. INSTALLED NEW FITTING WITH NEW FASSDR UPS03840898Fitting · crackedINSPECTION TYPE: C3, AFT PIT BETWEEN STA 1260 AND STA 1280 STR 31L CRACKED REMOVED CRACKED LONGERON SPLICE IAW SRM 51-1-20D. REC'D, LOCATED AND DRILLED NEW SPLICE IAW DC8 SRM 51-1-24. INSTALLED IAW DC8 SRM 5 1-1-20DSDR 03FDEA00841Hinge · damagedMDIS 245 53-30 0005255 27MAY03 BFM CLOSE R COMPLY WITH E.A. NR 7-5330-70910 FUSELAGE - MAIN CARGO-RE WORK OF ATTACHMENT HOLE (AD 2002-16-19). FACT 30 MAY 03 15:18 BFM R COMPLIED WITH E.A. 7-5330-70910 - FUSELAGE - MAIN CARGO - REWORK OF HINGE ATSDR DHL2003604776Attach Fitting · corrodedFWD ACCESSORY COMPT FITTING ATTACHING FLOORBEAM TO CUSP EXTRUSION AT STA 25.000 L-21R CORRODED. PERFORMED MAJOR REPAIR IAW SRM 53-1-0 PG 1, SRM 51-1-20D PG 9, 21, SRM 51-3-0 PG 1. REMOVED CORROSION FROM FITTING IAW SRM 51-1-8 PG 17-18. FOUND OUT OF LIMITS ISDR DHL2003604766Attach Fitting · corrodedFWD ACCESSORY COMPT FITTING ATTACHING FLOORBEAM TO FRAME AT STA 35.000 L-21R CORRODED. PERFORMED MAJOR REPAIR IAW SRM 53-1-0 PG 1, SRM 51-1-20D PG 9, 21. REMOVED CORROSION FROM FITTING IAW SRM 51-1-8 PG 17-18. FOUND OUT OF ALLOWABLE LIMITS IAW SRM 53-2-0 PGSDR DHL2003604733Attach Fitting · crackedMAIN CARGO COMPT. FITTING CRACKED 2.000 AT STA.1187.000, L-21R. PERFORMED MAJOR REPAIR IAW SRM 53-1-0 PG.1, SRM 51-1-20D PG.9,21. REMOVED CRACKED FITTING IAW SRM 51-1-20D PG.21. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. INSTALLED NEW FITTING WITH NEWSDR DHL2003604698Attach Fitting · crackedMAIN CARGO COMPT. FITTING CRACKED 1.000 AT STA. 1170.000, L-21R. PERFORMED MAJOR REPAIR IAW SRM 53-1-0 PG.1, SRM 51-1-20D PG.9,21. REMOVED CRACKED FITTING IAW SRM 51-1-20D PG.21. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. INSTALLED NEW FITTING WITH NESDR MWEA030234Attach Fitting · corrodedKINGPOST ATTACHING FITTINGS AT STATION 1322 AND LONGERON 30 HAS BAD EDGE DISTANCE AND CORROSION REPAIR IN THE AREA WILL MAKE HOLES UNUSABLE. -- FABRICATED AND INSTALLED FITTINGS.SDR DHL2003604699Attach Fitting · crackedMAIN CARGO COMPT. FITTING CRACKED 1.000 AT STA. 1210.000, L-21R. PERFORMED MAJOR REPAIR IAW SRM 53-1-0 PG.1, SRM 51-1-20D PG.9,21. REMOVED CRACKED FITTING IAW SRM 51-1-20D PG.21. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. INSTALLED NEW FITTING WITH NEW SDR DHL2003604694Fitting · crackedMAIN CARGO COMPT FITTING CRACKED 2.000, STA. 1177.000, L-21R. PERFORMED MAJOR REPAIR IAW SRM 53-1-0 PG.1, SRM 51-1-20D PG.9, 21. REMOVED CRACKED FITTING IAW SRM 51-1-20D PG.21. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. INSTALLED NEW FITTING WITH NEW FSDR DHL2003604703Fitting · crackedAFT ACCESSORY COMPT FITTING AT STA 660.000 WITH 7.000 CRACK IN IT BETWEEN L-35R AND L-36. PERFORMED MAJOR REPAIR IAW SRM 53-1-0 PG 1, SRM 51-1-20D PG 9, 21, SRM 51-3-0 PG 1. REMOVED CRACKED FITTING IAW SRM 51-1-20D PG 21. CLEANED, TREATED AND PRIMED AREA IASDR UPS03840760Attach Fitting · crackedINSPECTION TYPE: C1, INTERCOSTAL TO FRAME ATTACH FITTING IS CRACKED STA 1152 LONG 20R. REMOVED AND REPLACED FITTING IAW DWG 4750419 AND SRM 51-1-20D.SDR UPS03840759Fitting · crackedINSPECTION TYPE: C1, STA 1781 LONG 17L END FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 4772397 AND SRM 51-1-20D.SDR UPS03840757Fitting · crackedINSPECTION TYPE: C1, STATION 1690 LONG 28L END FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 4641324 AND SRM 51-1-20D.SDR UPS03840756Fitting · corrodedINSPECTION TYPE:C1 A/C BAY STA 70 LONG FRAME FITTING 34L IS CORRODED BEYOND LIMITS. REMOVED AND REPLACED FITTING IAW DWG 4611159 AND SRM 51-1-20D.SDR AWXA200300628Attach Angle · crackedDURING C-03 CHECK A .3125 INCH CRACK WAS FOUND ON AFT CARGO COMPARTMENT FORWARD BULKHEAD PANEL ATTACH ANGLE AT UPPER LT CORNER. MAINTENANCE REMOVED EXISTING REPAIR DOUBLER; STOP DRILLED CRACK; FABRICATED A NEW REPAIR DOUBLER; INSTALLED REPAIR PART IAW AWA ER SDR UPS03840709Attach Fitting · crackedINSPECTION TYPE: C1, INTERCOSTAL TO FRAME ATTACH FITTING IS CRACKED AT STATION 1220 AT LONG 20R. REMOVED AND REPLACED FITTING IAW DWG 4750418 AND SRM 51-1-20D.SDR UPS03840706Fitting · crackedINSPECTION TYPE:C1 INTERCOSTAL TO FRAME ATTACH FITTING IS CRACKED AT STA 1160 LONG 18R. REMOVED AND REPLACED FITTING IAW DWG 4750419 AND SRM 51-1-20D.SDR UPS03840705Fitting · crackedINSPECTION TYPE: C1, LT SIDE STA 800 ON SUBFLOOR AFT OF FLOORBEAM AT LBL 60 THERE IS A CRACKED SUPPORT FITTING. REMOVED AND REPLACED FITTING IAW DWG 3643112 AND SRM 51-1-20D.SDR UPS03840704Fitting · crackedINSPECTION TYPE:C1 INTERCOSTAL TO FRAME ATTACH FITTING IS CRACKED AT STA 1200 LONG 20R. REMOVED AND REPLACED FITTING IAW DWG 4750419 AND SRM 51-1-20D.SDR UPS03840703Fitting · crackedINSPECTION TYPE: C1, INTERCOSTAL TO FRAME ATTACH FITTING IS CRACKED AT STA 1152 LONG 19R. REMOVED AND REPLACED FITTING IAW DWG 4750418 AND SRM 51-1-20D.SDR UPS03840702Fitting · crackedINSPECTION TYPE: C1, INTERCOSTAL TO FRAME ATTACH FITTING IS CRACKED AT LONG 1180 LONG 18R. REMOVED AND REPLACED FITTING IAW DWG 4750419 AND SRM 51-1-20D.SDR UPS03840700Attach Fitting · crackedINSPECTION TYPE: C1, INTERCOSTAL TO FRAME ATTACH FITTING IS CRACKED AT STA 1220 LONG 19R. REMOVED AND REPLACED FITTING IAW DWG 4750419 AND SRM 51-1-20D.SDR UIEA200300024Fitting · crackedDURING C-CHECK AT SIN, FOUND LT NOSE CARGO DOOR PORTAL FRAME CRACKED ON FUSELAGE AT BS 281, WL 312 AND LBL 40, REF SRM 53-10-04 FIG 97. THE NOSE CARGO DOOR PORTAL FRAME CRACK WAS REPAIRED BY MODIFYING SRM 747-53-10-04 FIGURE PER REF TO MATCH THE REPAIR GEOMETSDR UPS03840707Fitting · crackedINSPECTION TYPE:C1 MAIN CABIN LONGERON END FITTING IS CRACKED BETWEEN STA 660-680 LONG 11L. REMOVED AND REPLACED FITTING IAW DWG 5750540 AND SRM 51-1-20D.SDR GTIA030462Fitting · corrodedFOUND STRINGER 29L APB TEE NUTS NOT SELF CENTERING IAW SB-53-201 AND REQUIRE GOUGE INSPECTION UPON REMOVAL. AFTER REMOVAL OF NUTS DISCOVERED CORROSION ON TEE FITTING. REMOVED TEE FITTING. LOCATED AND DRILLED NEW TEE FITTING. INSTALLED TEE FITTING. (M)SDR GTIA030399Fitting · crackedFOUND NOSE WHEEL WELL, STATION 70 LBL 16 AND RBL 16, TWO FITTINGS CRACKED. REMOVED TWO FITTINGS. LOCATED AND DRILLED HOLES ON TWO NEW FITTINGS. INSTALLED TWO NEW FITTINGS. (M)SDR UPS03440792Fitting · corrodedINSPECTION TYPE: C, LT MLG W/W STA 1480 CUTOUT PNL O/B OF O/B TRUNNION FITTING AREA FOUND CORRODED AT ACCESS PANEL AREA. CORROSION BLEND OUT (0.030 X 1 X 3 INCH) BULKHEAD WEB REPAIRED AS PER SRM 51-40-02 FIG 1.SDR DHL2003604708Fitting · crackedMAIN CARGO COMPT BATHTUB FITTING AT STA 680.000 L-6R WITH 1.500 CRACK IN IT. PERFORMED MAJOR REPAIR IAW SRM 53-1-0 PG 1, SRM 51-1-20D PG 9, 21, SRM 51-1-21 PG 1. REMOVED CRACKED BATHTUB FITTING IAW SRM 51-1-20D PG 21. CLEANED, TREATED AND PRIMED AREA IAW SRSDR AWXA200300562Fitting · corrodedDURING C-09 CHECK EXFOLIATION CORROSION WAS FOUND ON 3 EACH GALLEY SUPPORT FITTINGS ON AFT SHEAR DECK AT BS 1681 LT, BS 1681R/H, AND BS 1715 LT. MAINTENANCE REMOVED AND REPLACED 3 EACH GALLEY SUPPORT FITTINGS ON AFT SHEAR DECK AT BS 1681 LT, BS 1681 RT, AND BSSDR AWXA200300547Fitting · corrodedLCQ - MAJOR REPAIR - DURING C-09 CHECK EXFOLIATION CORROSION WAS FOUND ON RT CORNER FITTING AT BS 1720. MAINTENANCE REMOVED CORRODED RT CORNER FITTING AT BS 1720; FABRICATED A NEW REPLACEMENT CORNER FITTING PER DWG 146N8722; INSTALLED REPAIR PART IAW B757-200SDR UPS03840725Attach Fitting · corrodedINSPECTION TYPE: C-2, MAIN CABIN CORRODED FITTING CENTER WING BOX TO SHEAR WEB ATTACH FITTING STA 920 RBL 66 APX. REMOVED AND REPLACED FITTING AND INSTALLED IAW DC8 SRM 51-3-2 AND 51-1-20D.SDR UPS03840724Fitting · corrodedINSPECTION TYPE: C-2, MAIN CABIN CORRODED FITTING CENTER WING BOX TO SHEAR WEB ATTACH FITTING STA 920 RBL 66 APX. REMOVED AND REPLACED FITTING AND INSTALLED IAW DC8 SRM 51-3-2 AND 51-1-20D.SDR UPS03840722Fitting · corrodedINSPECTION TYPE: C-2, MAIN CABIN - FLOORBEAM TO FUSE ATTACHMENT FRAME STA 915 RBL 66 APX CORRODED. REMOVED CORROSION ON FRAME FITTING, OUT OF LIMITS IAW DC8 SRM 53-2-0 FIG 1F. REMOVED FITTING, LOCATED, DRILLED, AND DEBURRED FITTING IAW DAC DWG 5643483. INSDR UPS03840730Angle · crackedINSPECTION TYPE: C-2, CRACK IN ANGLE ATTACHING TO KEELBEAM AT STA 902 BETWEEN MLG DOORS. REMOVED AND REPLACED FITTING (P/N 4775262-501) IAW DC8 SRM 51-1-21.SDR AUS20030545Attach Fitting · cracked(AUS) FUSELAGE FRAME CLEATS CRACKED. SMALL CRACK IN CLEAT AT UPPER AFT FASTENER HOLE IN BS707 STRINGER 10L. FOUND DURING EDDY CURRENT INSPECTION.SDR DHL2003801069Fitting · crackedAFT ACCY COMPT - SPLICE FITTING CRACKED 1.000 INCH FS 1690.000 L-18L (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW SRM 53-1-0 PG 1. REMOVED DAMAGED SPLICE FITTING SRM 51-1-21 PG 1. CLEAN, TREATED AND PRIMED AREA IAW SRM 51-1-8B. INSTALLED NEW FITTING IAW SRM SDR DHL2003801026Fitting · crackedMAIN CARGO COMPT FITTING ATTACHING FRAME TO RT CUSP EXTRUSION AT STA 702.875 WITH 2.000 INCH CRACK. REMOVED DAMAGED FITTING IAW SRM 51-1-20D PG 21. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. INSTALLED NEW FITTING IAW SRM 51-1-20D PG 9.SDR ASAA0380409Fitting · corrodedOKC - DURING 30K CHECK, FOUND MID CARGO BAY LOWER DOOR JAMB FITTING IS CORRODED AT FS 636-644. REPLACED DAMAGED FITTING, SUPPORT PER SRM 51-10-2, 4, AND 5. (M)SDR ASAA0380389Fitting · corrodedOKC - DURING 30K CHECK, FOUND FUSELAGE STATION 200 LBL 8 FITTING CORRODED. REPLACED FITTING PER SRM. (M)SDR ABXA030202Attach Fitting · crackedTAIL SKID UPPER ATTACH FITTING CRACKED. REPLACED FITTING IAW DC-8 SRM 51-1-20 AND 51-1-21. REMOVED AND REPLACED GILLINER IAW DC-8 SRM 51-1-21.SDR AWXA200300415Fitting · crackedMCN - MAJOR REPAIR - DURING C-04 CHECK A .5 INCH CRACK WAS FOUND FORWARD CARGO FRAME CUTOUT AFT SIDE FITTING, FR 28, STR 35 RT. MAINTENANCE REMOVED DAMAGED FORWARD CARGO FRAME CUTOUT AFT SIDE FITTING, FR 28, STR 35 RT; FABRICATED A NEW REPLACEMENT FITTING; INSDR UPS03840629Fitting · crackedINSPECTION TYPE: C1, STA. 660 - 680 LONG. 11 LT SPLICE FITTING IS CRACKED REMOVED AND REPLACED FITTING I.A.W. DWG. 5750540,AND SRM. 51-1-20D
Back to JASC 5340