JASC 5345
Service difficulty reports · 822
Reports filed under 5345 · Fuselage, Equipment Attach Fittings, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5345' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5345' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR PIDA200500012Channel · crackedCRACK IN LOWER RADIUS AT AFT END OF THE LEFT MOUNT HAT CHANNEL FOR THE RADAR TR UNIT. REPAIRED HAT CHANNEL PER SRM 51-70-12.SDR ASAA0540203Plate · scratchedUPPER TCAS MOUNTING PLATE IS DAMAGED, REPLACED MOUNTING PLATE. (K)SDR 252TR0032Attach Bracket · crackedRIGHT RAM AIR DUCT FORWARD UPPER O/B ATTACH BRACKET CRACKED. REPLACED ATTACH BRACKET PER SRM 51-10-2 AND 51-40-03.SDR USAA050195Mount · corrodedPIT - FOUND MOUNT GALLEY AFT CORRODED 3 INCH BY 3 INCH AREA, LEFT AFT GALLEY MOUNT BS 990, BS 1016 LBL 32.10. REPLACED MOUNT LEFT AFT GALLEY PER SRM 51-40-00. (M)SDR USAA050162Bracket · crackedPIT - Q6 - BRACKET, 10 INCHES LONG CRACK; VHF COMM ANT BRACKET, STA 500-500A FWD BAGGAGE PIT; REMOVED AND REPLACED CRACKED BRACKET, BLENDED CORROSION IAW SRM. (K)SDR USAA041066Mount · corrodedPIT-Q5-LAV MOUNTS, 2 INCHES X 2 INCHES (2 EA) CORROSION; LEVEL 1; TASK NR C53-107-02, STA 913, LBL 21 AND LBL 34. DEFECTIVE PART REPLACED WITH IDENT PART NR. (K)SDR USAA041065Mount · corrodedPIT-Q5-LAV MOUNTS (2), 2 INCHES X 2 INCHES (2 EA), CORROSION; LEVEL 1; TASK NR C53-107-02, STA 994, RBL 21 AND RBL 34. DEFECTIVE PART REPLACED WITH IDENT PART NR. (K)SDR ASAA0470033SSupport · corrodedPAE: DURING MAINTENANCE CHECK, FOUND CORROSION ON SIDE WALL SUPPORT FRM BS727 TO BS767. REPAIRED IAW SRM 51-40-05. (K)SDR MWEA040198Mount · corrodedGALLEY ONE MOUNTING FEET HAVE MINOR CORROSION. REMOVED CORROSION.SDR P5CA0401145Angle · brokenL-ANGLE BROKEN AT STA 1940, L1 BIL 20 AFT CARGO AREA. REMOVED AND REPLACED BROKEN BRACKET PER SRM 51-30-02. NEW BRACKET FABRICATED PER SRM 53-11-23.SDR P5CA04011053Stop Fitting · corrodedSTOP FITTING STA 1490 L1 BL20 HAS CORROSION AFT PIT. REMOVED FASTENERS TO FOM IAW 51-40-02, REMOVED CORROSION, MAX MATERIAL REMOVED IAW 53-10-01, OK TO TREAT.SDR CALA0400389Mount · corrodedFORWARD LAV MOUNT CORRODED AT STA 300 LBL 10. REMOVED AND REPLACED DAMAGED MOUNT PER SRM 51-10-02.SDR CALA0400388Mount · corrodedFORWARD CABIN LAV MOUNT AT STATION 300 LBL 42 CORRODED. REMOVED AND REPLACED MOUNT PER SRM 51-10-02.SDR AWXA200400326Galley Track · corrodedMCN - MAJOR REPAIR - DURING C-15 CHECK EXFOLIATION CORROSION WAS FOUND ON AFT END OF FORWARD GALLEY LOWER OUTBOARD MOUNT TRACK AT BS 294, RBL 43, WL 208.5. MAINTENANCE REMOVED FORWARD GALLEY LOWER OUTBOARD MOUNT TRACK AT BS 294, RBL 43; FABRICATED A NEW REPLASDR MWEA030455Channel · corrodedJ-CHANNEL AT STATION 200 FROM RIGHT SIDE OF CENTERLINE OUTBOARD HAS SERVERAL FASTENER HOLE LOBES CORRODED ON UPPER AND LOWER SIDE OF LOBES. FABRICATED AND INSTALLED NEW J-CHANNEL.SDR MWEA030454Channel · corrodedJ-CHANNEL FROM STATION 160-200 IS CORRODED AROUND FASTENER HOLE JUST INBOARD OF PAX DOOR. FABRICATED AND INSTALLED J-CHANNEL.SDR MWEA030453Channel · corrodedCORROSION FOUND J-CHANNEL FRAME STATION 160-200, EIGHTEEN INCHES INBOARD OF FORWARD GALLEY SERVICE DOOR. FABRICATED AND INSTALLED NEW J-CHANNEL.SDR MWEA030452Channel · corrodedJ-CHANNEL FRAME STATION 160-200 SIXTEEN INCHES INBOARD OF FORWARD GALLEY DOOR IS CORRODED ALONG TOP SURFACE. FABRICATED AND INSTALLED NEW J-CHANNEL.SDR QXEA200301434Support Bracket · brokenPDX- SUPPORT BRACKET FOR LOWER ENGINE FIRE BOTTLE DISCHARGE INDICATOR LINE BROKEN AND CHAFING FUSELAGE. REPAIRED IAW HORIZON AIR EA 2-53-513.SDR CALA0300631Mount · corrodedINSPECTION FOUND AFT I/B G-2 GALLEY MOUNT CORRODED. THE CORROSION WAS REMOVED AND A DOUBLER WAS INSTALLED IAW ECRA 2531-01056.SDR AWXA200301120Bracket · crackedDURING C-07 CHECK THE RT APU DOOR HOLD OPEN HANDLE STAY PIN BRACKET WAS FOUND CRACKED. MAINTENANCE REMOVED AND REPLACED RT APU DOOR HOLD OPEN STAY PIN BRACKET IAW AWA E.R. 26-5358-03270-ES-1.SDR CALA0300437Mount · corrodedINSPECTION FOUND RT AFT LAV AFT WALL MOUNT PADS CORRODED AT STA 947.5. THE MOUNT PADS WERE REMOVED AND REPLACED IAW SRM 51-40-02.SDR AWXA200300438Plate · corrodedMCN - EES - DURING C-17 CHECK CORROSION WAS FOUND ON TOP SURFACE OF GIRT FITTING ATTACH BRACKET (PLATE) AT L-2 DOOR FWD FITTING. MAINTENANCE REMOVED AND REPLACED GIRT FITTING ATTACH BRACKET AT L-2 DOOR PER T/C C1D25018.SDR ASAA0240168Shelf · crackedPAE - DURING C-CHECK, FOUND RADAR TRANSCEIVER SHELF IS CRACKED BELOW AFT END OF LEFT MOUNT CHANNEL. REPAIRED IAW SRM. (M)SDR ASAA0380033Fitting · corrodedOKC - FOUND DURING 30K CHECK, G-1 GALLEY LOWER INBOARD MOUNT FITTING IS CORRODED. REPLACED FITTING PER SRM 51-30-2. (M)SDR AALA20021731Mount · corrodedTUL - FOUND STATION 218 G2 INBOARD FLOOR TIEDOWN HAS CORROSION. REPAIRED G2 INBOARD FLOOR TIEDOWN PER AARD 53-00-00-02. (M)SDR AALA20021730Mount · corrodedTUL - FOUND STATION 212, G2 INBOARD FLOOR TIE DOWN HAS CORROSION. REMOVED AND REPLACED G2 FLOOR TIE DOWN STATION 212. (M)SDR AALA22021735Bracket · corrodedTUL - FOUND CORROSION, G1 FORWARD CENTER FLOOR TIE DOWN. REMOVED AND REPLACED TIE DOWN BRACKET. (M)SDR AALA20021734Mount · corrodedTUL - FOUND CORROSION, G1 FORWARD INBOARD FLOOR TIE DOWN. REMOVED AND REPLACED TIE DOWN. (M)SDR ASAA0240234Mount · crackedPAE - DURING C-CHECK, FOUND MOUNT CRACKED AT BS 204, LBL 5 AND WL 175. REPAIRED IAW SRM. (M)SDR 02FDEA00766Attach Fitting · corrodedINBD AFT TOILET MOUNTING ATTACHMENT CORRODED AT BS 421. R&R SUPPORT PER SRM 51-33-01, VOL II.SDR ASAA0280376Support Fitting · corrodedOKC - DURING 30K-CHECK, FOUND GALLEY SUPPORT FLOOR STRUCTURE CORRODED AT FS 175, RBL 26. REPLACED GALLEY SUPPORT FITTING PER SRM 51-10-4 AND 51-30-5. (M)SDR SWIA200211515Channel · cracked#2 PRESSURE AND RETURN MANIFOLD CHANNEL CRACKED THROUGH BOLT HOLE. FOUND DURING C CHECK INSPECTION. FITTED AND INSTALLED NEW CHANNEL IAW SRM 51-40-11, 51-42-06. RE-INSTALLED HYDRAULIC COMPONENTS IAW CRJ MM CH. 49-11-05. P/N: 600-75221-130SDR F3LA200200293Attach Angle · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON CLOSET ATTACH ANGLES AT BS 1015. FABRICATED AND INSTALLED REPLACEMENT ANGLES PER BOEING DRAWING 65-48812 AND SRM 51-40-02.SDR AWXA200200729Fitting · corrodedMCN - MAJOR REPAIR - DURING C-17 CHECK CORROSION WAS FOUND ON L/H AFT LAVATORY OUTBOARD MOUNT FITTING BS 1010, LBL 65. MAINTENANCE REMOVED AND REPLACED L/H AFT LAVATORY OUTBOARD MOUNT FITTING BS 1010, LBL 65, IAW B737-300 SRM 51-40-02, PG. 6-10, AND SRM 53-60-SDR AWXA200200740Fitting · corrodedMCN - MAJOR REPAIR - DURING C-17 CHECK CORROSION WAS FOUND ON R/H AFT LAVATORY OUTBOARD FORWARD MOUNT FITTING BS 967, RBL 60. MAINTENANCE REMOVED AND REPLACED R/H AFT LAVATORY OUTBOARD FORWARD MOUNT FITTING BS 967, RBL 60, IAW B737-300 SRM 51-40-02, PG. 6-10, SDR AWXA200200739Fitting · corrodedMCN - MAJOR REPAIR - DURING C-17 CHECK CORROSION WAS FOUND ON L/H AFT LAVATORY OUTBOARD FORWARD MOUNT FITTING BS 967, LBL 60. MAINTENANCE REMOVED AND REPLACED L/H AFT LAVATORY OUTBOARD FORWARD MOUNT FITTING BS 967, LBL 60, IAW B737-300 SRM 51-40-02, PG. 6-10, SDR AWXA200200738Fitting · corrodedMCN - MAJOR REPAIR - DURING C-17 CHECK CORROSION WAS FOUND ON R/H AFT LAVATORY INBOARD FORWARD MOUNT FITTING BS 967, RBL 50. MAINTENANCE REMOVED AND REPLACED R/H AFT LAVATORY INBOARD FORWARD MOUNT FITTING BS 967, RBL 50, IAW B737-300 SRM 51-40-02, PG. 6-10, ANSDR AWXA200200737Fitting · corrodedMCN - MAJOR REPAIR - DURING C-17 CHECK CORROSION WAS FOUND ON L/H AFT LAVATORY INBOARD FORWARD MOUNT FITTING BS 967, LBL 50. MAINTENANCE REMOVED AND REPLACED L/H AFT LAVATORY INBOARD FORWARD MOUNT FITTING BS 967, LBL 50, IAW B737-300 SRM 51-40-02, PG. 10-11, ASDR AWXA200200712Angle · crackedMCN - MAJOR REPAIR - DURING C-17 CHECK A CRACK WAS FOUND ON ATTACH ANGLE BETWEEN BS 927 AND 947, BL 0. MAINTENANCE REMOVED CRACKED ATTACH ANGLE, FABRICATED A NEW ATTACH ANGLE, AND INSTALLED REPAIR IAW B737-300 SRM 51-40-02, PG.6-7.SDR 2002F01048Mount · corrodedAT C-CHECK, FOUND GALLEY SERVICE TIE DOWN RETRACTABLE POST SUPPORT MOUNT CORRODED, AT STATION 815, RBL 95. (M)SDR AALA20020669Fitting · corrodedTUL - FOUND G2 LOWER INBOARD TIEDOWN FITTING AT STATION 218 IS CORRODED, FITTING BELOW DIAPHRAGM SUB FLOOR. INSTALLED NEW G-2 INBOARD LOWER TIE DOWN FITTING STATION 217-218, SRM 51-01 (2C), 51-10-04 AND 51-30-05. (M)SDR AALA20020461Fitting · corrodedTUL - FOUND GALLEY TIE DOWN FITTING CORRODED FORWARD OF NR 6 SEAT TRACK STATION 214. INSTALLED SERVICEABLE TIE DOWN FITTING SRM 51-01. (M)SDR AALA20020014Bracket · corrodedTUL - FOUND LOWER AFT INBOARD MOUNT FOR G2 GALLEY HAS HEAVY CORROSION AT BOLT HOLE ON FORWARD SIDE OF FLOORBEAM. REMOVED AND REPLACED CORRODED BRACKET WITH NEW SERVICEABLE BRACKET, TREATED AND PRIMED PER SRM 51-01. (M)SDR AALA20011912Fitting · corrodedTUL - - FOUND STATION 215 G2 FORWARD TIE DOWN CORRODED. REPLACED CORRODED TIE DOWN BRACKET WITH NEW BRACKET AND HARDWARE SRM 51-01. (M)SDR CALA0100804Mount · corrodedINSPECTION FOUND GALLEY FLOOR MOUNT CORRODED AT STA 292, RBL 12. A NEW GALLEY FLOOR MOUNT WAS INSTALLED IAW SRM 51-10-02.SDR ZW0A0100807Mount · corrodedDURING CHECK-C MAINT NUMBER 1 GALLEY TIE DOWN AT BL 10.5R, BL 45R AND BL 51R, HAD CORROSION. INSTALLED GALLEY TIE DOWNS PER SRM 51-30 AND 51-10-4.SDR CALA0100387Mount Bracket · corrodedINSPECTION FOUND AFT LEFT LAV FLOOR MOUNT BRACKET CORRODED AT STA 1016, LBL 6. THE FLOOR MOUNT BRACKET WAS REMOVED AND REPLACED IAW SRM 51-40-02.SDR ZW0A0100310Fitting · corrodedDURING CHECK-C MAINT FOUND CORROSION ON NUMBER 1 GALLEY TIE DOWN FITTINGS. REPLACED TIE DOWN FITTINGS PER SPM 6-70-01.SDR CALA0100316Mount · corrodedINSPECTION FOUND AFT GALLEY AFT I/B MOUNT CORRODED AT STA 967, LBL 14. THE GALLEY MOUNT WAS REMOVED AND REPLACED IAW SRM 51-40-02 AND 51-10-02.
Back to JASC 5345