JASC 5345
Service difficulty reports · 821
Reports filed under 5345 · Fuselage, Equipment Attach Fittings, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5345' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5345' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR VNAA202606120022Fitting · corrodedCORROSION FLOOR FITTING IN AFT ACCESS 109 (1EA) ON GALLEY 1. FLOOR FITTING P/N CDSP2019-7C-620 IN AFT ACCESS 109 (1EA) ON GALLEY 1 WAS REPLACED PER SAFRAN CMM 25-33-96SDR VNAA202606060015Fitting · corrodedCORROSION FLOOR FITTING IN FWD ACCESS 107 (1EA) ON GALLEY 1. FLOOR FITTING IN FWD ACCESS 107 (1EA) ON GALLEY 1 WAS REPLACED IAW CMM 25-33-21.SDR REXA2026060400908Fitting · corrodedCORROSION FLOOR FITTING IN AFT ACCESS 108 (1EA) ON GALLEY 1. FLOOR FITTING IN AFT ACCESS 108 (1EA) ON GALLEY 1 WAS REPLACED PER SAFRAN CMM 25-33-67 REV. 10SDR REXA2026060400906Fitting · corrodedCORROSION FLOOR FITTING IN AFT ACCESS 108 (1EA) ON GALLEY 1. FLOOR FITTING IN AFT ACCESS 108 (1EA) ON GALLEY 1 WAS REPLACED PER SAFRAN CMM 25-33-67 REV. 10SDR REXA2026060400905Fitting · corrodedCORROSION FLOOR FITTING IN AFT AND FWD ACCESS 205 (2EAS) ON GALLEY 2. FLOOR FITTING (PN: A391251-3) IN AFT ACCESS 205 (1 EA) ON GALLEY 2 WAS MANUFACTURED PER EA CRJ953-22214 REV IR AND INSTALLED PER CMM 25-32-84 REV NO. 9 AND FLOOR FITTING ( PN: 9861251-3 IN SDR REXA2026070301059Fitting · corrodedCORROSION FLOOR FITTING IN AFT AND FWD ACCESS 107 (2EAS) ON GALLEY 1. FLOOR FITTING IN AFT AND FWD ACCESS 107 (2EAS) ON GALLEY 1 WERE REPLACED PER SAFRAN CMM 25-33-67 REV NO.10SDR VNAA202606120012Fitting · corrodedCORROSION ON FITTINGS SUPPORT (2 EAS) OF GALLEY ATTACHMENT FITTING FS=285.00 RBL 17 AND FS=288.00 LBL 20 AT FWD CPAX CABIN STRUCTURE. CORROSION ON FITTINGS SUPPORT (2 EAS) OF GALLEY ATTACHMENT FITTING FS=285.00 RBL 17 AND FS=288.00 LBL 20 AT FWD CPAX CABIN STSDR REXA2026061700971Fitting · corrodedCORROSION FLOOR FITTING IN AFT ACCESS 205 (1EA) ON GALLEY 2. FLOOR FITTING IN AFT ACCESS 205 (1EA) ON GALLEY 2 WAS MANUFACTURED PER EA CRJ953-22205 REV IR. AND INSTALLED IAW CMM 25-32-84SDR DALA2026051403013Attach Fitting · corrodedAFT RT GALLEY-AFT RT FLOOR ATTACH POINT CORRODED 8" FORWARD OF FR 79. REF SSI 53-61-43-02. NO REWORK NOTED. SUMMARY SEE NR FOR ADDITIONAL INFORMATION 001-0586:5300-2016/003 00526 REMOVED AND REPLACED FITTING, REF AIRBUS 220 DRAWING C01349710, AND A220 ASRP 51-SDR ASAA2026042165876Mount · corrodedPASSENGER CABIN STA 916.5 LBL 51.55 DUAL FLOOR MOUNT ATTACHING INTERCOSTAL HAS CORROSION AROUND MOUNT. GROUNDED - YES. REMOVED AND REPLACED 147A5690-8 INTERCOSTAL IAW BAC DWG 147A5680 REV - AND B737-800 SRM 51-40-02. ALLOWABLE LIMITS IN SRM FOUND DEEMED OUT OFSDR REXA2026042700364Mount · corrodedFOUND GALLEY 1 AISLE AFT INBOARD FLOOR MOUNT IS CORRODED UPON REMOVING GALLEY 1 AISLE AFT INBOARD FLOOR MOUNT IAW SAFRAN 25-33-96, PG110, FOUND THE FLOOR FITTING DOUBLER TO BE CORRODED REPLACED GALLEY 1 AISLE AFT INB FLOOR FITTING DOUBLER P/N 9335071-1 IAW CRJSDR VNAA20260418019Fitting · corrodedCORROSION FLOOR FITTING P/N 9331091-3 IN FWD ACCESS 109 (1EA) ON GALLEY 1. FLOOR FITTING P/N 9331091-3 IN FWD ACCESS 109 (1EA) ON GALLEY 1 WAS REPLACED PER CMM 25-33-21SDR VNAA20260418018Fitting · corrodedCORROSION FLOOR FITTING IN FRONT ACCESS 107 (1EA) ON GALLEY 1. FLOOR FITTING IN FRONT ACCESS 107 (1EA) ON GALLEY 1 WAS REPLACED PER SAFRAN CMM 25-33-21SDR REXA2026051500600Fitting · corrodedCORROSION FLOOR FITING IN FWD ACCESS 107 AND AFT ACCESS 108 (2EAS) ON GALLEY 1 SUMMARY OF NRC 00151: FLOOR FITINGS IN FWD ACCESS 107 AND AFT ACCESS 108 (2EAS) ON GALLEY 1 WERE REPLACED PER SAFRAN CMM 25-33-67 REV.NO 10SDR REXA2026051500599Fitting · corrodedCORROSION FLOOR FITING IN FWD ACCESS 107 AND AFT ACCESS 108 (2EAS) ON GALLEY 1 SUMMARY OF NRC 00151: FLOOR FITINGS IN FWD ACCESS 107 AND AFT ACCESS 108 (2EAS) ON GALLEY 1 WERE REPLACED PER SAFRAN CMM 25-33-67 REV.NO 10SDR REXA2026051500598Fitting · corrodedCORROSION FLOOR FITING IN FWD ACCESS 306 AND ACCESS 305 (2EAS) ON GALLEY 3 SUMMARY OF NRC 00150: FLOOR FITINGS IN FWD ACCESS 306 AND 305 (2EAS) ON GALLEY 3 WERE REPLACED PER ZODIAC AEROSPACE CMM 25-33-18 REV.NO 5SDR REXA2026051500597Fitting · corrodedCORROSION FLOOR FITING IN FWD ACCESS 306 AND ACCESS 305 (2EAS) ON GALLEY 3 SUMMARY OF NRC 00150: FLOOR FITINGS IN FWD ACCESS 306 AND 305 (2EAS) ON GALLEY 3 WERE REPLACED PER ZODIAC AEROSPACE CMM 25-33-18 REV.NO 5SDR SWIA2026040776259Mount · corrodedFORWARD CARGO BAY, FWD CARGO NET MOUNTING PLATE CORRODDED APROX FS 533 BETWEEN S23-24 LT. REPLACED AND INSTALLED NEW BRACKET SH670-33389-1, IAW DWG.SH670-33600 REV AD, SRM.51-42-10-001-001-A01 AND SRM 51-42-21-001-001-A01, AND SRM 51-42-22-001-001-A01. ALSOSDR REXA2026080601528Fitting · corrodedCORROSION ON FITTING THE FRONT RIGHT CORNER (1 EA) AT GALLEY 2 SUMMARY OF NRC 00221:FITTING THE FRONT RIGHT CORNER (1 EA) AT GALLEY 2 WAS REPLACED PER SAFRAN CMM 25-32-84SDR REXA2026080601527Fitting · corrodedCORROSION FLOOR FITTING ACCESS 109 (1EA) , BEHIND ACCESS 108 (1EA) , IN FRONT ACCESS 107 (1EA) AT GALLEY 1 SUMMARY OF NRC 00220: FLOOR FITTING ACCESS 109 (1EA) , BEHIND ACCESS 108 (1EA) , IN FRONT ACCESS 107 (1EA) AND DOUBLER (1EA) IN FRONT ACCESS (107) AT GALSDR VNAA20260501019Fitting · corrodedCORROSION ON FWD RH FITTING (1EA) UNDER WASTER CONTAINER AT FWD LAV. NEW FWD RH FITTING (1EA) UNDER WASTER CONTAINER AT FWD LAV WAS REPLACED SAFRAN CMM 25-40-40 REV. NO. 20SDR VNAA20260501018Fitting · corrodedCORROSION FLOOR FITTING IN FRONT ACCESS 107 (1EA) ON GALLEY 1. FLOOR FITTING IN FRONT ACCESS 107 (1EA) ON GALLEY 1 WAS REPLACED PER SAFRAN CMM 25-32-02SDR AALA202604102309Tie Down · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON L1 DOOR FORWARD GIRT BAR TIEDOWN AT STA 312 AND LBL 55. REPLACED TIEDOWN PER AARD 51-00-05-1.SDR REXA2026080501493Fitting · corrodedCORROSION ON FITTING PN: CDSP2019-7C-760 IN FRONT ACCESS 107 (1EA) AND FITTING PN: CDSP2019-7C-620 AFT IN ACCESS 108 (1EA) ON GALLEY SUMMARY OF NRC 290:FITTING (1 EA) AND DOUBLER (1 EA) IN FRONT ACCESS 107 AND FITTING (1 EA) AFT IN ACCESS 108 (1 EA) ON GALLEY SDR REXA2026080501492Fitting · corrodedCORROSION ON FITTING IN FRONT ACCESS 107 (1EA) AND FITTING PN: CDSP2019-7C-620 AFT IN ACCESS 108 (1EA) ON GALLEY FITTING (1 EA) AND DOUBLER (1 EA) IN FRONT ACCESS 107 AND FITTING (1 EA) AFT IN ACCESS 108 (1 EA) ON GALLEY WERE REPLACED IAW CMM 25-33-67.SDR REXA2026050400443Fitting · corrodedWEAR AND CORROSION ON FLOOR FITTINGS AT FLOOR SUPPORT STRUCTURE BTW FS280 TO FS295 LBL 38(1EA) RBL17(1EA), FS310 LBL20(1EA) AND DAMAGE ANCHORD NUT ON FLOOR FITTING BTW 349 TO FS364 RBL36 (1EA). FLOOR FITTINGS AT FLOOR SUPPORT STRUCTURE BTW FS280 TO FS295 LBL SDR REXA2026050400441Fitting · corrodedWEAR AND CORROSION ON FLOOR FITTINGS AT FLOOR SUPPORT STRUCTURE BTW FS280 TO FS295 LBL 38(1EA) RBL17(1EA), FS310 LBL20(1EA) AND DAMAGE ANCHORD NUT ON FLOOR FITTING BTW 349 TO FS364 RBL36 (1EA). FLOOR FITTINGS AT FLOOR SUPPORT STRUCTURE BTW FS280 TO FS295 LBL SDR AALA202603094409Tie Down · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON L1 DOOR FLOOR MOUNTED FORWARD GIRT BAR TIEDOWN AT BS 312 , LBL 54. REPLACED TIEDOWN PER AARD 51-00-05-1.SDR YENA2026030400264Mount · corrodedDURING HEAVY MAINTENANCE: CPCP TASK FWD GALLEY MOUNTING POST @FR 14 ON Y-81 FLOOR BEAM CORRODED; REMOVED AND REPLACED FLOOR BEAM Y-81 AT FR 12 TO FR 16 IAW A321 SRTM 51-42-11 AND SRM 53-11-14-10-C ALL WORK ACCOMPLISHED ON STS WO W004054 NR N0496.SDR REXA2026080601506Fitting · corrodedCORROSION AFT RH FLOOR FITTING ON ACCESS 306 (1EA) ON GALLEY 3. AFT RH FLOOR FITTING ON ACCESS 306 (1EA) (PN: CDSP2019-7C-650) ON GALLEY 3 WAS REPLACED PER ZODIAC AEROSPACE CMM 25-33-18SDR SWIA2026022675942Mount · corrodedGALLEY FLOOR FITTING AT BS 382, RBL 36 CORRODED. REPLACED THE CORRODED GALLEY FLOOR MOUNT FITTING WITH NEW IAW SRM 51-42-21-001-001-A01, AND DWG SH670-32120, REV D. MAJOR REPAIR.SDR VNAA202603140013Fitting · corrodedCORROSION ON FITTING (1 EA) BELOW THE SERVICE TABLE AT FWD LAV. FITTINGBELOW THE SERVICE TABLE AT FWD LAV WAS REPLACED PER CMM 25-40-40SDR VNAA202603140012Fitting · corrodedCORROSION FLOOR FITTING BEHIND ACCESS 108 (1EA) ON GALLEY 1. FLOOR FITTING BEHIND ACCESS 108 (1 EA) ON GALLEY 1 WAS REPLACED PER SAFRAN CMM 25-33-96SDR DALA2026021801159Mount · corrodedCORROSION AT FRAME 73 RT INBD LAV MOUNT. REPLACED THE AFT RH LAV MOUNT REF NEO SRM 51-72-11. (1451964)SDR VNAA202603140011Support Fitting · corrodedCRACK ON CENTER FLOOR BEAM RBL 12.0 BTW 221.73 TO FS 229.00 AT FWD FUSELAGE INTERNAL STRUCTURE. CORROSION ON FITTING SUPPORT (FLOOR STRUCTURE) BTW FS 280.0 TO FS 300.0 CORDENATES RBL 23 AND LBL 23 ALSO LBL 31 AT PASSENGER CABIN. CORROSION ON FITTING SUPPORTSDR ASAA2026020964518Intercostal · corrodedRIGHT AFT LAV MOUNT INTERCOSTAL IS CORRODED FOUND WHILE WORKING 947 FRAME CORROSION. GROUNDED - YES. LOCATED AND DRILLED NEW INTERCOASTAL IAW BOEING 737-900ER SRM 51-40-05-0G-0. REMOVAL ANED INSTALL MAINTENANCE PERFORMED ON AAR MIG-5 OK456722 W/O 1023835 2000 SDR IXXA20260204009Mount · damagedPORTABLE FIRE EXTINGUISHER MOUNTING BRACKET WILL NOT HOLD, FIRE EXTINGUISHER FALLS OFF. PLACED ON DEFERRAL 70338 MINIMUM EQUIPMENT LIST ATI-26-26-01-01 CATEGORY D. REMOVED AND REPLACED FIRE EXTINGUISHER MOUNTING BRACKET IN ACCORDANCE WITH B767 SRM 51-40-02.SDR VNAA20260304023Fitting · corrodedCORROSION FLOOR FITTING ACCESS 107. REPLACED IAW CMM 25-33-21.SDR SWIA2026012476084Fitting · corrodedGALLEY 1 FWD OUTBOARD FLOOR ATTACHMENT MOUNT BOLT FITTING HAS CORROSION BETWEEN LBL9 AND RBL9 AT FS295.00 (MARKED). (C-CHECK RO 05/22/2026)REMOVED & INSTALLED NEW GALLEY 1 FWD OUTBOARD FLOOR ATTACHMENT MOUNT BOLT FITTING PN: SH670-32149-3 BETWEEN LBL9 AND RBSDR SWIA2026012476081Fitting · corrodedGALLEY FWD OUTBOARD FLOOR ATTACHMENT MOUNT BOLT FITTING HAS CORROSION BETWEEN FS280.00 - FS295.00 AND R/H FLOOR SILL AND RBL27 (MARKED). (C-CHECK RO 05/22/2026)REMOVED & INSTALLED NEW GALLEY FWD OUTBOARD FLOOR ATTACHMENT MOUNT BOLT FITTING PN: SH670-32149-3 SDR SWIA2026012476053Mount · corrodedGALLEY 1 FWD OUTBOARD FLOOR ATTACHMENT MOUNT BOLT FITTING HAS CORROSION BETWEEN LBL9 AND RBL9, FS310.00 AND FS319. REMOVED & INSTALLED NEW GALLEY 1 FWD OUTBOARD FLOOR ATTACHMENT MOUNT BOLT FITTING BETWEEN LBL9 AND RBL9, BS 310 AND BS 319 IAW SRM 51-42-21-001-SDR VNAA20260303014Fitting · corrodedCORRODED FLOOR FITTING ON ACCESS 107. FLOOR FITTING WAS REPLACED IAW CMM 25-33-21.SDR JR2R20260115009Mount · corrodedFLOOR MOUNT ANGLE ON BEAM 16 AT RBL28 CORRODED. REPLACEDSDR SWIA2025122475088Mount · crackedWEATHER RADAR LOWER MOUNTING BRACKET CRACKED. REMOVED AND REPLACED WEATHER RADAR LOWER MOUNTING BRACKET IAW SRM 51-40-08.SDR VNAA20260201014Fitting · corrodedCORROSION ON FITTINGS NUT ON FLOOR STRUCTURE BTW FS 379-394 RBL 17 (1EA), AND BTW FS 259-310 RBL 4 (1EA) AND BTW FS 280-295 RBL 9 TO RBL 37 (2EAS). FITTINGS NUT ON FLOOR STRUCTURE BTW FS 379-394 RBL 17 (1EA), AND BTW FS 259-310 RBL 4 (1EA) AND BTW FS 280-29SDR VNAA202512186006Fitting · corrodedCORROSION FLOOR FITTING ACCESS 109 (1EA) , BEHIND ACCESS 108 (1EA) , IN FRONT ACCESS 107 (1EA) AND FWD CORNER OF AISLE SIDE (1EA) ON GALLEY 1. FLOOR FITTING ACCESS 109 (1EA PN:CDSP2019-7C620 ) , BEHIND ACCESS 108 (1EA PN:CDSP2019-7C620), IN FRONT ACCESS 107 SDR VNAA202512186005Fitting · corrodedCORROSION FLOOR FITTING UNDER THE WASTE AND AISLE SIDE ON FWD LAVATORY. THE FLOOR FITTINGS WERE REPLACED IAW CMM 25-40-40.SDR VNAA202512020023Mount Fitting · corrodedGALLEY MOUNT FITTING IS CORRODED BETWEEN F.S. 280 TO F.S. 295 AND BETWEEN RBL 9 TO RBL 18.SDR REXA2026052700730Fitting · corrodedCORROSION FLOOR FITTING BEHIND ACCESS 108 (1EA) AND IN FRONT ACCESS 107 (1EA) ON GALLEY 1. FLOOR FITTING IN FRONT ACCESS 107 (1 EA) WAS REPLACED PER SAFRAN CMM 25-33-67 AND FLOOR FITTING BEHIND ACCESS 108 (1EA) WAS FABRICATED PER EA CRJ953-21146. REV IR AND ISDR SWIA2025111476567Mount · corrodedFWD INBD MAIN FLOOR MOUNTING BRACKET CORRODED. REMOVED AND REPLACED WITH ONE OF NEW MOUNTING BRACKET. IAW SRM 51-42-21-001-001-A01 AND DWG SH670-32120, REV. D. COMPLIED WITH ALL STEPS OF TASK CARD 51-900-1002-SKY.
Back to JASC 5345