JASC 5345
Service difficulty reports · 821
Reports filed under 5345 · Fuselage, Equipment Attach Fittings, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5345' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5345' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR VNAA20251204006Fitting · corrodedCORROSION FLOOR FITTING ON ACCESS 305 (2EA´S) ON WARDROBE. FLOOR FITTING ON ACCESS 305 (2EA´S) ON WARDROBE WAS REMOVED PER CMM 25-33-30SDR VNAA20251204004Fitting · corrodedCORROSION FLOOR FITTING BEHIND ACCESS 108 (1EA) AND (1EA) IN FRONT ACCESS 107 ON GALLEY 1. FLOOR FITTINGS BEHIND ACCESS 108 (1EA) AND IN FRONT ACCESS 107 (1EA) ON GALLEY 1 WERE REPLACED PER SAFRAN CMM 25-33-96SDR DALA2025102007632Fitting · corroded(LOG 1255801) STA 947 FLOORBEAM HAS CORROSION UNDER LAV FITTING AT RBL50. PERFORMED REPAIR ON STA 947 FLOOR BEAM UNDER LAV FITTING AT RBL50 IAW B737-900 SRM 53-70-51-2R-8. RESTORED FINISH TO AREA IAW B737-900 SRM 51-20-01-0G.SDR JR2R20251010277Support Fitting · corrodedAFTER REMOVAL OF RH SHEAR WEB, FOUND INBOARD GALLEY SUPPORT CORRODED ON TOP SURFACE DOWN INTO BOLT HOLE. REPLACED.SDR JR2R20251008282Fitting · corrodedAFTER REMOVAL OF R/H SHEAR PANEL FOUND OUTBOARD GALLEY SUPPORT CORRODED. REPLACED.SDR JR2R20251005912Mount Bracket · crackedLOWER WEATHER RADAR SERVO MOUNT BRACKET CRACKED AT RH ATTACH CLIP. REPLACEDSDR DALA2025101307474Gusset · corrodedSHIP 185 CORROSION ON AFT LAV SUPPORT STRUCTURE 3EA GUSSETS 146T3248-9. CORRECTIVE ACTION: REPLACED GUSSETS REF BAC DWG 146T3244 (1231764)SDR DALA2025101307486Support · corrodedSHIP 185 CORROSION ON AFT LAV SUPPORT STRUCTURE 2EA GUSSETS 146T3248-13. CORRECTIVE ACTION: REPLACED GUSSETS REF BAC DWG 146T3244 (1231766)SDR N6WA2025100212Mount · corrodedCORROSION ON LH MOUNT FITTING AT FS310.00 LBL19. REMOVED AND REPLACED LH MOUNT FITTING IAW CRJ SRM 51-42-21SDR N6WA2025100211Mount · corrodedCORROSION ON RH MOUNT FITTING AT FS285.00 RBL36. REMOVED AND REPLACED RH FITTING AT FS285.00 RBL36 IAW CRJ SRM 51-42-21SDR SWI2025F01890Mount Fitting · corrodedENTRANCE STORAGE COMPARTMENT FWD OTBD BETWEEN LT FLOOR SILL & LBL 27 AT BS 280 TO BS 295 MOUNT FLOOR STRUCTURE FITTING CORROSION. REMOVED AND INSTALLED NEW MOUNT FITTING BTWN LT FLOOR SILL AND LBL 27, BS 280 TO BS 295 IAW DWG SH670-32120 REV. D & SRM 51-42-21SDR CALA2025090208369Mount · corrodedG1 GALLEY MOUNT FITTINGS BETWEEN BS 324 AND BS 335 HAVE CORROSION. REMOVED AND REPLACED 2EA FITTING AT MAIN STA 324 RS 335 IAW SRM 51-40-02-OG.SDR CALA2025090208367Mount · corrodedMAIN CABIN FLOOR WEB , FWD OF AFT PRESSURE BULKHEAD ALL GALLEY MOUNTS CORRODED. REMOVED AND REPLACED ALL GALLEY MOUNTS FITTING 5EA IAW SRM 51-40-02-OG.SDR SWIA2025081375366Mount · brokenGALLEY 1, MOST AFT INBD MOUNTING NUT PLATE IS BROKEN. UPON INSPECTION FOUND THE NUTPLATE BROKEN AND GALLEY 1, MOST AFT INBD MOUNTING FITTING ASSEMBLY TO BE CORRODED AND NEEDS TO BE REPLACED. REMOVED AND REPLACED THE GALLEY 1, MOST AFT INBD MOUNTING FITTING ASSDR DALA2025080505864Fitting · corrodedUPPER FUSELAGE, FWD ENTRY AREA RIGHT CLOSET ATTACH FITTINGS WITH CORROSION. REPLACED UPPER FUSELAGE FWD ENTRY AREA RIGTH CLOSET ATTACH FITTING IAW ENCORE CMM 25-31-94.SDR AALA202508118430Tie Down · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON L1 DOOR FLOOR MOUNTED FORWARD GIRT BAR TIEDOWN AT BS 312, LBL 54. REPLACED TIEDOWN PER AARD 51-00-05-1.SDR AALA202508117456Tie Down · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON L1 DOOR FLOOR MOUNTED AFT GIRT BAR TIEDOWN AT BS 344, LBL 58. REPLACED TIEDOWN PER AARD 51-00-05-1.SDR SWAA2025082194493Fitting · corrodedFWD GALLEY G-1 O/B AFT TIE-DOWN FITTING HAS CORROSION. R & R FWD GALLEY G-1 O/B AFT TIE-DOWN FITTING PER CMM 25-31-71 AND SRM 51-40-02.SDR REXA2025072900773Fitting · corrodedCORROSION ON GALLEY FITTINGS (5 EAS) FS 288.00 LBL 37, FS 295.00 RBL 3, FS 316.00 RBL 4 AND FS 285.00 RBL 17 AND RBL 38 APROX AT PAX CABIN GALLEY FITTINGS (5 EAS) FS 288.00 LBL 37, FS 295.00 RBL 3, FS 316.00 RBL 4 AND FS 285.00 RBL 17 AND RBL 38 APROX AT PAX CSDR DALA2025070104892Attach Bracket · corrodedAFT FUSELAGE GALLEY FLOOR SUPPORT BEAM GALLEY ATTACH BRACKET AT FR79 AND RBL23 HAS CORROSION ON UPPER SURFACE AND OXIDATION IN BORE. SCEPTRE LOG PAGE ENTERED FOR SDR REPORTING. SUMMARY SEE NR FOR ADDITIONAL INFORMATION 001-0583:5300-2016/003 00359 CORROSION COSDR AALA202507142052Mount · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON LEFT HAND AFT LAVATORY OUTBOARD AFT MOUNT AT BS 947, LBL 48. REPLACED MOUNT PER AARD 51-00-05-1.SDR AALA202507145481Mount · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON LEFT HAND AFT LAVATORY INBOARD AFT MOUNT AT BS 947, LBL 25. REPLACED MOUNT PER SRM 53-70-51-2R REPAIR 5.SDR AALA202506192267Mount · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON PASSENGER CABIN RIGHT HAND AFT LAVATORY OUTBOARD MOUNT AT BS 947, RBL 48. REPAIRED PER SRM 51-10-02.SDR VNAA20250716008Fitting · noneFITTING P/N: A414252-3 PER EA NO: 25-2025-0817. FITTING P/N:A414252-3 WAS FABRICATED PER EA NO: 25-2025-0817 REV -- SECTION III-PERMANENT REPAIRSDR VNAA20250716007Fitting · corrodedCORROSION ON FITING (PN: A414252-3) 1EA BELOW THE SERVICE TABLE AT FWD LAV. FITING (PN: A414252-3) 1EA BELOW THE SERVICE TABLE AT FWD LAV. WAS REPLACED PER SAFRAN CMM 25-40-40SDR VNAA20250715022Fitting · corrodedCORROSION ON FLOOR FITTING (PN: CDSP2019-7C-620) 1EA ACCESS 107 COUNTER AT GALLEY 1. BRACKET FLOOR FITTING ACCESS 107 COUNTER AT GALLEY 1 WAS REPLACED PER SAFRAN CMM 25-33-96SDR AALA202506261143Tie Down · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON L1 DOOR FLOOR MOUNTED AFT GIRT BAR TIEDOWN AT BS 344, LBL 60. REPLACED TIEDOWN PER AARD 51-00-05-1.SDR CALA2025061305539Mount · corroded(SDR) (19-5305-1-2068): CABIN FLOOR GALLEY MOUNT FITTING HAS COR ROSION STA 1685, CENTER LINE - "1". ESFR COMPLETED. EVALUATED CORROSION ON CENTER GALLEY MOUNT FITTING AND FOUND NO SRM ALLOWABLE LIMITS. REMOVED AND REPLACED CENTER GALLEY MOUNT FITTING 415N4002SDR VNAA20250610066Fitting · corrodedGALLEY 1 FWD FLOOR FITTINGS FS 285.00 L/H AND R/H ARE CORRODED ON UPPER SURFACE. REMOVED BOTH R/H AND L/H FLOOR (P/N- SH670-32149-3) IAW CRJ 700 SRM1-42-21-001-001-A01. INSTALLED BOTH NEW SERVICEABLE FLOOR FITTINGS (P/N-SH670-32149-3) IAW CRJ 700 SRM 51-42-2SDR DALA2025060904372Mount · corroded(LOG 1009034) AFT GALLEY CTR R/H MOUNT HAS EVIDENCE OF CORROSION. REMOVED AND REPLACED AFT GALLEY CTR R/H ,MOUNT IAW B737 SRM 51-40-02.SDR AALA202506190427Tie Down · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON L1 DOOR FLOOR MOUNTED FORWARD GIRT BAR TIEDOWN AT BS 312, LBL 55. REPLACED TIEDOWN PER AARD 51-00-05-1.SDR DALA2025052904134Fitting · corroded(LOG 0990074) CORROSION ON FLOOR FITTING (4EAS) AT CLOSET. FLOOR FITTING (4EAS) AT CLOSET WERE REPLACED PER ER/A NO. 626423-14 REV. ORIGINAL.SDR CALA2025052004851Fitting · corrodedAFTER REMOVAL OF THE HARDPOINT AT AFT WET AREA FOUND CORROSION UNDER HARD POINT GALLEY FITTING AT BEAM STA 947 RBL 52. REPAIRED AFT WET AREA FOUND CORROSION UNDER HARD POINT GALLEY FITTING AT BEAM STA 947 RBL 33 TO RBL 56, SRM 53-70-51-2R-S. REPAIRED, INSTALSDR DALA2025052003871Fitting · corroded(LOG 0969276) CORROSION BTW UPPER CHORD OF BEAM AND LAVATORY FLOOR FITTING STA 947.5 LBL60-65 AT PASSENGER COMPARMENT. LAVATORY FLOOR FITTING STA 947.5 LBL60-65 AT PASSENGER COMPARMENT.WAS REPAIRED PER B737-800 SRM 53-70-51-2R PROCEDURE 5 REPAIR 5SDR DALA2025051903826Fitting · corroded(LOG 0968639) CORROSION FITING LOCATED IN FRONT WALL OF LAVATORY A AT PASSENGER CABIN. COMPLIED WITH ER/A 625424-14 REV A.SDR SWIA2025090900502Mount · corrodedINBD WARDROBE MOUNT FITTING IS CORRODED FS287 (C-CHECK RO 09/07/2025)REMOVED AND REPLACED INBD WARDROBE MOUNT FITTING FS287 REF DWG SH670-32120 REV D, CRJ700 SRM 51-42-21-001-001-A01. COMPLIED WITH SKYWEST TASKCARD 51-900-1002-SKY.SDR VNAA20250602014Fitting · corrodedCORROSION ON FLOOR FITTING ACCESS 107 COUNTER AT GALLEY 1. FLOOR FITTING ACCESS 107 COUNTER AT GALLEY 1 WAS REPLACED PER SAFRAN CMM 25-33-96SDR JR2R20250423496Mount · corrodedFWD CABIN, FWD GALLEY, AFT O/B MOUNT IS CORRODED.SDR DALA2025042403203Mount · corroded(LOG 0926902) AFT R/H LAV, AFT O/B MOUNT FITTING HAS SEVERE CORROSION. REMOVED AND REPLACED LAV E AFT, O/B MOUNT FITTING ATTACHMENT BLOCK, FLOOR PANEL BLOCK, FLOOR FITTING BLOCK, INSIDE (FWD) SKIN AND OUTSIDE AFT SKIN, INSIDE (FWD) DOUBLER AND OUTSIDE (AFT) DOSDR DALA2025042403202Fitting · corroded(LOG 0927907) CORROSION ON OUTER FLOOR FITTINGS 2 E/AS ON GALLEY 2 (G2) AT CPAX. DAMAGED FLOOR FITTING DOUBLER P/N: D782132-7 WAS FABRICATED PER ER/A 625699-14 REV. ORIGINAL AND PER PRI 625699-14 REV. 0 AND FLOOR FITTINGS P/N: 9352091-501 (2EAS) WERE REPLACED SDR VNAA20250525003Fitting · corrodedCORROSION ON FLOOR FITTING ACCESS 211 COUNTER AT GALLEY 2. FLOOR FITTING ACCESS 211 COUNTER AT GALLEY 2 WAS REPLACED PER ZODIAC AEROSPACE CMM 25-32-78SDR DALA2025040302548Fitting · corroded(LOG 0889667) CORROSION ON FLOOR FITTINGS (4 EAS) ON CLOSET. REPLACED PER SAFRAN CMM 25-32-28 AND FLOOR FITTINGS (3 EAS) ON CLOSET WERE FABRICATED AND INSTALLED PER PRI 625312-14 REV. 0 AND ER/A 625312-14 REV. ORIGINAL.SDR WRXR20250331002Mount · corrodedGALLEY #3 HAS CORRODED MOUNT (PN:CDSP2019-7C650). REMOVED AND REPLACED GALLEY #3 MOUNT IAW CRJ 900 VCMM 25-33-30.SDR VNAA20250320045Mount · corrodedHN00203615 DISCREPANCY: RBL 16.0 FS 285.00 GALLEY1 MOUNT FITTING CORRODED CORRECTIVE ACTION: REMOVED FITTING AND INSTALLED NEW SERVICEABLE FLOOR FITTING P/N 670-32149-3 IAW CRJ700 51-42-21-001-001-A01SDR WRXR20250310001Mount Bracket · corrodedFOUND CORRODED FLOOR FOOT MOUNT UPON REMOVAL OF GALLEY #1 AT FS 310.00 RH BL22.50. (LH AFT FLOOR FOOT). REMOVED AND REPLACED CORRODED FLOOR FOOT MOUNT (PN CDSP2019-7C-620) ON GALLEY #1 LOCATION AFT LH.SDR VNAA202504140021Fitting · corrodedCORROSION ON FITTING (2EA) BELOW THE SERVICE TABLE AND AISLE SIDE AT FWD LAV. FITTING PN:A414252-3 (1EA) BELOW THE SERVICE TABLE WAS REPLACED PER SAFRAN CMM 25-40-40 AND FITTING PN: A414251-1 (1EA) AISLE SIDE AT FWD LAV WAS FABRICATED AND INSTALLED PER EASDR DALA2025030901794Mount · corrodedAIRCRAFT 8123, GALLEY G4 FWD HALF MOUNT FITTINGS CORRODED. CORRECTIVE ACTION: REPLACED FITTINGS W/REF TO SAFRAN CMM 25-30-17. (LP 0847834)SDR CALA2025030402578Fitting · damagedAFTER REMOVAL OF THE DAMAGE MACHINED INTERCOSTAL AND FITTING FOUND DAMAGE CORROSION UNDER HARD POINT GALLEY FITTING REQUIRE REPAIR FLOOR BEAM STA 947.5 RBL 46 (REF: AAR NR 1000031077) ESFR COMPLETED PERFORMED REPAIR AT FLOOR BEAM STA 947.5 RBL 46 IAW B737-900ESDR JR2R20250224410Attach Angle · crackedFWD FACE PRESS. BULKHEAD RADAR RH SIDE UPPER AND LOWER SUPPORT FITTING ATTACH ANGLES CRACKEDSDR JR2R20250224411Support Fitting · crackedFWD FACE PRESS. BULKHEAD RADAR RH SIDE UPPER AND LOWER SUPPORT FITTING CRACKED
Back to JASC 5345