JASC 5510
Service difficulty reports · 5,966
Reports filed under 5510 · Horizontal Stabilizer Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5510' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5510' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR R61A201307060619Rib · crackedDURING HEAVY CHECK, FOUND LT RIB 11 FWD LOWER FLANGE CRACKED AT AFT FASTENER. MX REMOVED DAMAGED FLANGE AND INSTALLED FABRICATED RIB IAW ETD2013-170-014268, REV 1.SDR R61A201307030630Rod End · corrodedDURING HEAVY CHECK, FOUND SURFACE CORROSION ON HORIZONAL STAB RT LOWER ADJUSTMENT ROD END. MX REMOVED AND REPLACED THE ROD END IAW AMM 53-30-21. PN M81935/2-12KL.SDR DALA13033059249Support Angle · damagedRIGHT HORIZONTAL STAB SUPPORT ANGLE AT REAR SPAR STA XE 167.953 HAS HEAVY EXFOLIATION. REMOVED DAMAGED SUPPORT ANGLE FROM RT HORIZONTAL STAB, T/E ANGLE STA XE167.953. FABRICATED, ALONDINED, PRIMED, TOP COATED AND INSTALLED NEW ANGLE IAW SRM 51-30-05 PARA 7 ASDR DALA13032959249Structure · corrodedHORIZONTAL STABILIZER, RT LOWER SURFACE FOURTH FROM AFT END HAS BARREL NUT PLUG PROTRUDING. INSPECTED AND FOUND CORROSION AT BARREL NUT HOLE, NR 32. REAMED HOLE AND LOCAL BLENDED REMAINING CORROSION IAW SRM 55-10-03, PARA 11. NO DEFECTS NOTED. FABRICATED, SDR DALA13032949249Support Angle · damagedHORIZONTAL STAB LEFT SUPPORT ANGLE AT REAR SPAR XE 167.953 HAS HEAVY EXFOLIATION. REMOVED DAMAGE SUPPORT ANGLE FROM LT HORIZONTAL STAB STA XE169.953. FABRICATED, ALODINED, PRIMED, TOPCOATED AND INSTALLED NEW SUPPORT ANGLE IAW SRM 51-30-02, PARA 7 AND PARA 8,SDR SWIA201333764Lug · gougedRT OTBD HORIZONTAL STABILIZER PIVOT LUG GOUGED AROUND PIVOT PIN HOLE. C-CHECK REPAIRED RT OTBD HORIZONTAL STABILIZER PIVOT LUG IAW REO.SDR DALA13031219249Skin · damagedHORIZONTAL STABILIZER LT LOWER SURFACE HAS SEVERAL BARREL NUT PLUGS THAT ARE DETERIORATED. CLEANED ALL BARREL NUT HOLES IAW SRM 51-20-00. FOUND 2 EA CORRODED. REMOVED 2 EA HOLES IAW 55-10-03, PARA II. HOLES NR 31 AND NR 37. REAMED TO ALLOWABLE LIMITS. FABRISDR CA130620008Bolt · worn(CAN) STABILATOR BALANCE WEIGHT ASSEMBLY OBSERVED WITH EXCESSIVE PLAY WHERE ASSY BOLTS TO STABILATOR. 2 EA AN3-17A BOLTS FOUND WORN.SDR ASAA2013061695274Panel · chafedRT HORIZONTAL BOW TIE PANEL CHAFED. ACFT GROUNDED. R & R BOW TIE PANEL IAW AMM 20-50-11-912-002, FIG 203.SDR FDEA201306141294Hinge Fitting · corrodedHORIZONTAL STABILIZER LT LOWER SKIN HINGE FITTING STRAP SUPPORT HAS CORROSION.SDR FDEA201306141293Hinge Fitting · corrodedHORIZONTAL STABILIZER LT LOWER SKIN HINGE FITTING STRAP SUPPORT HAS CORROSION.SDR ASOA2013062708526Pin · lack of lubeLT AND RT STAB PIN DUE LUBE AND INSPECTION. REPAIRED IAW EC/TC REO 670-55-11-099 01, AND MET THE REQUIREMENTS OF REO 670-55-11-099, REV G. REPAIR CLASSIFIED AS MAJOR.SDR ASOA2013062708525Flange · chafedLT SIDE AND RT SIDE HORIZONTAL STAB PIVOT ANTI-ROTATION FLANGES CHAFED. REPAIRED IAW EC/TC REO 670-55-11-099 01, REPAIR CLASSIFIED AS MAJOR.SDR TIMA20130718004Tee Fitting · crackedDURING AN INSPECTION, A CRACK IN THE LT HORIZONTAL STABILIZER LOWER TEE EXTRUSION WAS DISCOVERED. REPAIRED THE CRACKED TEE EXTRUSION BY SPLICING IN A NEW SECTION IAW REPAIR FR-CO-02598. TWO REPAIR ANGLES WERE FABRICATED USING A SECTION OF A NEW TEE.SDR USAA2013062400045Hinge Pin · crackedQ5 CHECK -CRACK ON LT HORIZONTAL STABILIZER INNER HINGE PIN AT BS1138, S16L, WL232.5. REPLACED LT HORIZONTAL STABILIZER INNER & OUTER HINGE PIN AT BS1138, S16L, WL232.5 IAW JOB CARD.SDR DALA13022136306Structure · crackedCRACK FOUND AT FASTENER HOLE A2 IN THE VICINITY OF RBL 43S. FASTENER HOLE A2 AT HORIZ STABILIZER CENTER SECTION, RBL 40 WAS REPAIRED IAW ERA 512576-14 AD REV ORIGINAL .SDR COEA2013062819912Stiffener · corrodedDURING HEAVY CHECK, RT HORIZONTAL STAB REAR SPAR STIFFENERS HAVE CORROSION. FABRICATED AND REPLACED PARTS WITH NEW IAW SRM 55-11-10, FIG 102, REV 99.SDR COEA2013061113912Stiffener · corrodedDURING HEAVY CHECK, RT HORIZONTAL STABILIZER REAR SPAR STIFFENERS HAVE CORROSION. REPLACED PART WITH NEW IAW SRM 55-11-10, FIG 102, REV 99. MAJOR REPAIR.SDR Y2PA20130507028Sleeve · crackedDURING C-CHECK INSPECTION, MX DISCOVERED BOTH LT AND RT HORIZONTAL STABILIZER HINGE BOLT SLEEVES CRACKED. MX R & R SLEEVES IAW AMM 55-10-0.SDR TIMA20130430002Tee Fitting · crackedDURING A SCHEDULED STRUCTURAL INSP A CRACK IN THE LT HORIZONTAL STABILIZER LOWER TEE EXTRUSION WAS DISCOVERED. REPAIRED THE CRACKED TEE EXTRUSION BY SPLICING IN A NEW SECTION OF TEE EXTRUSION IAW FR-CO-02598. 2 REPAIR ANGLES WERE FABRICATED USING A SECTION SDR ASOA20130427143VTab · brokenDURING C-CHECK LT HORIZONTAL STAB HINGE PIN ANTI-ROTATION PIN TAB IS BROKEN. MX R & R LT HORIZONTAL STAB HINGE PIN OTBD HOUSING FITTING BY REWORKING LT HINGE TO NR 2 OVERSIZE IAW SRM 55-10-02 AND EC5510-01240. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20130427142Tab · brokenDURING C-CHECK RT HORIZONTAL STAB HINGE PIN ANTI-ROTATION TAB IS GOUGED AND PIN IS BROKEN. MX R & R RT HORIZ STAB HINGE PIN OTBD HSG FITTTING IAW SRM 55-10-02 AND EC5510-01240. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20130427141VFitting · brokenDURING C-CHECK LT AND RT HORIZONTAL STABILIZER HINGE PINS LOCK RETAINING PINS BROKEN AND HINGE PINS ROTATED. MX R & R LT AND RT HINGE PIN HOUSING FITTINGS IAW SRM 55-10-02 AND EC5510-01240. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR GLBA2013042600240Tee Fitting · crackedDURING A SCHEDULED ROUTINE INSPECTION FOUND 2 CRACKS IN THE TEE SECTION OF THE RT HORZ STAB LOWER AT HSS 5.000 AND 10.5 PERCENT CHORD, .75" IN LENGTH. REPAIRED IAW EO 13-1900-55-014. MAJOR REPAIR.SDR HYTA2013F00090Horn · crackedDURING A ROUTING 100HR/ANNUAL INSPECTION, CRACKS WERE FOUND IN SUPPORTING .025 WEB OF HORIZONTAL STABILATOR HORN ASSY AND ALSO A CRACK RADIATING FROM LIGHTNING HOLE OF .063 FORWARD COVER PLATE (PN 391-020-305-2) THAT IS PART OF THE BOLTED ASSEMBLIES SECURING TSDR UHLA2013041500199Structure · damagedLT HORIZONTAL STABILIZER SPHERICAL BEARING HOUSING FOUND TO BE OUT OF LIMITS ON INNER BORE. R & R LH HORIZONTAL STABILIZER SPHERICAL BEARING HOUSING. MAJOR REPAIRSDR UHLA2013041500198Structure · damagedRT HORIZONTAL STABILIZER SPHERICAL BEARING HOUSING FOUND TO BE OUT OF LIMITS ON INNER BORE. R & R RT HORIZONTAL STABILIZER SPHERICAL BEARING HOUSING. MAJOR REPAIR.SDR DALA13016360945Fairing · crackedRT UPPER BANANA FAIRING 3806 HAS 3 INCH CRACK AT FWD END. DETERMINE CRACKS LENGTH REF SPM 06-10 01-001-STOP DRILLERS ATR/UPPER BANANA FAIRING 38. NO CRACK INDICATION PAST STOP DRILLS FOUND. FABRICATED AND INSTALLED DOUBLER RT UPPER BANANA FAIRING 3806 IAW SSDR 7AHR20130415007Attach Angle · crackedLT UPPER HORIZONTAL STABILIZER FAIRING, UPPER ATTACH ANGLES CRACKED AT FASTENERS HOLES. FABRICATED REPAIR ANGLES IAW SRM 51-10-2. LOCATED AND DRILLED THE FORWARD AND AFT ANGLE IAW SRM 51-10-04. INSTALLED NEW ANGLES IAW SRM 51-30-2.SDR ASOA2013050203469Bushing · damagedLT BUSHINGS AT HORIZONTAL STAB HINGE ARE DAMAGED. REPAIRED IAW REO 601R-55-00-045 REV B, 2013/04/27. MAJOR REPAIRSDR UALA2013040402228Stabilizer · damagedRIGHT STAB HAS A CREASE 10 FT INBD OF OTBD EDGE 1 FT LONG .5 DEEP,STARTS AT LEADING EDGE AND GOES AFT. ACP'D HFEC OF CREASED AREA IAW NDTM 51-10-08 PART 6. NO CRACKS INDICATED.SDR GLBA2013040100222Structure · crackedDURING A SCHEDULED ROUTINE INSPECTION, FOUND A CRACK IN THE TEE SECTION OF THE LT HORIZONTAL STAB LOWER AT HSS 5.000 AND 10.5 PERCENT AT A SCREW HOLE, .5" IN LENGTH. REPAIRED IAW EO 13-1900-55-011. MAJOR REPAIR.SDR UALA2013032902036Stabilizer · damagedLEFT STABILIZER HAS DAMAGE. REPAIRED IAW ECRA 5510-02283 FROM STEP 1 THRU 9.SDR GLBA2013032900218Structure · crackedDURING A SCHEDULED ROUTINE INSPECTION FOUND A CRACK IN THE RT HORIZONTAL STAB LOWER TEE SECTION AT HSS 5.000 AND 10.5 PERCENT CHORD, 1.5" IN LENGTH. REPAIRED IAW EO 13-1900-55-010. MAJOR REPAIR.SDR LR7A2013032500506Angle · crackedDURING SCHEDULED C-11 CHECK, FOUND LT HORIZONTAL STABILIZER L/E FRAME ANGLE CRACKED LT SIDE FS 1041, WL 283: HSS 115, HSS 186, AND HSS 198. REPAIRED IAW SMP583 SRM FIG 51-140-20.SDR DALA1308533746Web · crackedRT HORIZONTAL STABILIZER STA 203 AND 8" AFT OF L/E INTERNAL WEB DAMAGE. REPAIRED IAW ERA 511673-14, STEPS 1-7, REV ORIG.SDR GLBA2013031900214Web · crackedDURING A SCHEDULED ROUTINE INSPECTION, FOUND TWO CRACKS IN THE HORIZONTAL STAB AFT WEB AT THE 10 & 2 O'CLOCK POSITION AROUND THE ACCESS HOLE, .15" IN LENGTH. REPAIRED IAW EO 13-1900-55-007. MAJOR REPAIR.SDR BN5A2013031100001Hinge Fitting · crackedC/W AD 89-12-08 STABILIZER AFT SPAR INSPECTION IAW SB 1124-55-020 R2. FOUND CRACK ON LEFT OUTER HINGE LUG UPPER FLANGE ONE INCH FROM TRAILING EDGE TRAVEL THRU TRAILING EDGE.SDR ABXA20130228405Structure · corrodedHORIZONTAL CENTER SECTION UPPER S-7 VERTICAL LEG HAS HEAVY CORROSION JUST OUTBOARD OF RIB 1L. BLENDED AREA OF CORROSION, BLENDED AREA WAS REWORKED AND FOUND TO BE PERMANENT REPAIR IAW REA B655-60485-MR, ACFT WAS GROUNDED.SDR CA130220006Spar · corroded(CAN) DURING REMOVAL OF THE ELEVATOR ATTACHMENT HINGE FOR REPLACEMENT, CORROSION WAS FOUND ON BOTH OTBD ENDS OF THE HORIZONTAL STABILIZER REAR SPAR. THE AREA WAS REPAIRED IAW THE SRM TO RECTIFY DEFECT.SDR UHLA2013021900092Hinge Fitting · damagedMAJOR REPAIR - BOTH HORIZONTAL HINGE FITTINGS ON HORIZ STAB REQUIRE INSPECTION DUE TO BACKLASH FAIL. LEFT AND RIGHT REAR HORIZONTAL STAB FITTINGS REPAIRED IAW ETD 2013-170-003022.SDR DALA1501800967Attach Fitting · damagedHORIZONTAL STAB HINGE RIB PIVOT BEARING LUG DAMAGED. REPAIRED IAW AA 5500-01011.SDR DALA1515550986Lug · not reportedHORIZONTAL STABILIZER HINGE RIB PIVOT BEARING LUG, REPAIRED IAW AA 5500-01011.SDR ASOA20130118016Attach Angle · corrodedDURING C-CHECK, PANEL 321DR ATTACHMENT FLANGE HAS CORRODED SCREW HOLES. MX PERFORMED REPAIR AT PANEL 321DR ATTACHMENT FLANGE SCREW HOLES IAW EC5510-01297. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR DALA13000670954Structure · damagedFOUND L/E DAMAGE AT XFS 184.750 ON LT HORIZONTAL STAB. FABRICATED AND INSTALLED REPAIR DOUBLER IAW SRM 55-03, FIG 22.SDR SWAA2013012311728Seal · crackedRIGHT HORIZONTAL STABILIZER FORWARD LOWER SLIDE SEAL IS CRACKED. REMOVED AND REPLACED RIGHT HORIZONTAL STABILIZER FORWARD LOWER SLIDE SEAL PER MM 55-31-31-000-801, MM 55-31-31-400-801 AND SOPM 20-50-01.SDR TIMA201306110011Tee Fitting · crackedDURING A SCHEDULED STRUCTURAL INSPECTION, A CRACK WAS DISCOVERED IN THE LT HORIZONTAL STABILIZER LOWER INBD TEE EXTRUSION. REPAIRED CRACKED TEE EXTRUSION BY SPLICING IN A NEW SECTION IAW FR-CO-02598-1. 2 REPAIR ANGLES, FR-CO-02598-1 WERE FABRICATED FROM A NESDR GLBA2012122000136Web · crackedDURING A SCHEDULED ROUTINE INSPECTION, FOUND A CRACK IN THE AFT HORIZONTAL STAB WEB, 0.125" IN LENGTH. REPAIRED IAW EO 12-1900-558-070. MAJOR REPAIR.SDR REXA2012122001747Hinge Fitting · gougedLEFT ELEVATOR HINGE NR 2 FITTING ON THE HORIZONTAL STAB IS GOUGED. REPAIRED IAW BOMBARDIER REO 601R-55-11-416.SDR REXA2012122001748Hinge Fitting · gougedRIGHT ELEVATOR HINGE NR 2 FITTING ON THE HORIZONTAL STABILIZER IS GOUGED. REPAIRED IAW BOMBARDIER REO 601R-55-11-447.
Back to JASC 5510