JASC 5520
Service difficulty reports · 5,421
Reports filed under 5520 · Elevator Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5520' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5520' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR C2XA01IA208Bearing · corrodedIAH - DURING C-CHECK INSPECTION, THE LEFT HAND AND RIGHT HAND ELEVATOR SPHERICAL BEARINGS WERE FOUND TO BE CORRODED. MAINTENANCE REMOVED AND REPLACED THE AFFECTED SPHERICAL BEARINGS IN ACCORDANCE WITH CONTINENTAL EXPRESS ENGINEERING AUTHORIZATION EA5510-01016SDR C2XA01IA207Hinge Pin · corrodedIAH - DURING C-CHECK INSPECTION, THE RIGHT HAND ELEVATOR HINGE PIN WAS FOUND TO BE CORRODED. MAINTENANCE REMOVED AND REPLACED THE AFFECTED HINGE PIN IN ACCORDANCE WITH EMB-145 M/M 55-10-00-400-801-A, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR 01FDEA00263Plate · crackedDURING ROUTINE INSP, RT ELEVATOR REAR SPAR NR 4 SHEAR PLATE FOUND CRACKED. REMOVED, REPLACED AND FAB PER IAW BAC 727 SRM 51-20-2, 51-30-2.SDR 20010509CW004Hinge Bracket · corrodedDURING INSPECTION, THE RIGHT OUTBOARD AND THE RIGHT MIDDLE ELEVATOR HINGE BRACKET WERE FOUND TO BE CORRODED.SDR SWAA010977Bearing · looseDURING SCHEDULED D-CHECK, FOUND LT ELEVATOR PCU UPPER ATTACH BEARING LOOSE. REMOVED AND REPLACED ELEVATOR PCU PER MM.SDR SWAA010935Bearing · wornDURING SCHEDULED C2 CHECK, LT ELEVATOR FAILED HINGE PLAY INSPECTION. REMOVED AND REPLACED ELEVATOR PUSH ROD BEARING PER MM.SDR SW15200110535Bushing · improper partTHE INCORRECT BUSHING WAS IDENTIFIED DURING DEMINSIONAL INSPECTION OF THE COUNTER- WEIGHT PRIOR TO INSTALLATION.SDR P5CA0100516Balance Weight · corrodedLEVEL 1 CORROSION FOUND ON BALANCE WEIGHT THREE LEFT OUTBOARD ELEVATOR. REPAIRED PER S/L 747-55-07.SDR P5CA0100515Balance Weight · corrodedLEVEL 1 CORROSION FOUND ON BALANCE WEIGHT TWO RIGHT OUTBOARD ELEVATOR. REPAIRED PER S/L 747-55-07.SDR EIA2001118Structure · crackedMZJ-EAC - FOUND RIGHT INBOARD ELEVATOR, UPPER SURFACE LE CRACK AT RIVET HEAD, 24 INCHES OUTBOARD OF INBOARD EDGE. REPAIRED RIGHT INBOARD ELEVATOR PER ECRA 3203-55-035-2. (M)SDR CA010403014Fitting · cracked(CAN) - LEFT ELEVATOR FITTING FOUND CRACKED AT UPPER HOLE. NEW FITTING P/N 5035005-3 INSTALLED.SDR DHL2001806544Structure · crackedC-CHECK 0- TAIL CONE INTERIOR PART, SIDE, RT AT STA 1920, SHOWS 1/2 INCH CRACK AND RIVETS LOOSE IN ELEVATOR TORQUE TUBE PROTECTOR. REMOVED FASTENERS IAW SRM 51-1-21 PAGE 1. PERFORMED STOP HOLE IAW SRM 53-2-0 FIG 1B. FABRICATED DOUBLER IAW SRM 53-2-0 FIG 1SDR 20010507CW015Bracket · corrodedINSPECTION DISCOVERED SIGNIFICANT CORROSION ON 2 RT ELEVATOR HINGE BRACKETS.SDR 20010507CW014Bracket · corrodedINSPECTION DISCOVERED SIGNIFICANT CORROSION ON 2 RT ELEVATOR HINGE BRACKETS.SDR MWEA010254Structure · tool damageLEFT ELEVATOR AT STATION XE 14.5 HAS A SMALL AREA OF TOOL MARKS. VIEWED THROUGH PANEL ACCESS 3503. FABRICATED AND INSTALLED DOUBLERS.SDR MASA01024Gust Lock · looseDURING ROUTINE MAINTENANCE, THE ELEVATOR GUST LOCK PLATES WERE FOUND TO HAVE LOOSE AND SMOKING JO-BOLTS. A REPAIR WAS COMPLIED WITH IAW RO DHC82-55-0004GJT (DEHAVILLAND RD 8-55-112). OP CHECKS GOOD. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR GTIA010220Bracket · crackedFTW - FOUND OUTBOARD MOUNTING BRACKET AT ELEVATOR POWER CONTROL FOLLOW UP MECHANISM CRACKED. REMOVED RIGHT OUTBOARD MOUNTING BRACKET, IAW DC-9 MM 27-30-3. (M)SDR AWXA0001420Elevator · damagedON REMOVAL OF RT ELEVATOR ABNORMAL SHEAR LOAD NOTED ON ELEVATOR ATTACH BOLTS AND ELEVATOR HINGE BEARINGS FOUND TO BE MISALIGNED. COMPLIED WITH AWA ER 26-5552-01054-DL2; ELEVATOR REPLACED IAW AMM 27-34-41-401.SDR CALA0100164Fitting · separatedINSPECTION FOUND LT ELEVATOR HORN BEARING FITTING SEPARATED. THE LT ELEVATOR WAS REMOVED AND REPLACED IAW MM 27-31-11.SDR MWEA010158Elevator · damagedLEFT ELEVATOR HAD LIGHTNING STRIKE EXIT DAMAGE OUTBOARD OF LAST STATIC WICK MOUNT ON TRAILING EDGE. REMOVED DAMAGED PARTS, FABRICATED, LOCATED AND INSTALLED NEW PARTS.SDR MWEA010155Skin · lightning strikeFOUND LIGHTNING STRIKE DAMAGE TO LEFT ELEVATOR OUTBOARD TRAILING EDGE. MAINTENANCE FABRICATED AND INSTALLED ELEVATOR SKIN REPAIR.SDR C2XA01IA120Bushing · corrodedIAH - DURING C-CHECK INSPECTION, THE CENTER BUSHING ON THE RIGHT HAND SERVO TAB WAS FOUND TO HAVE PITTING CORROSION. MAINTENANCE REMOVED AND REPLACED THE AFFECTED BUSHING IN ACCORDANCE WITH EMB-145 M/M 20-10-08, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERSDR QXEA0100113Elevator · incorrectPDX- RIGHT HAND ELEVATOR INBOARD TRAILING EDGE DOES NOT FARE WITH ELEVATOR SKIN. REPAIRED IAW DHC-8 SRM 51-40-00.SDR 20010315CW001Hinge Bracket · corrodedUPON INSPECTION OF RIGHT HAND OUTBOARD HORIZONTAL STABILATOR ELEVATOR HINGE BRACKET A BADLY EXFOLIATED BRACKET WAS FOUND. A FLEET INSPECTION REVEALED 4 OUT OF 5 AIRCRAFT HAD THE CORRODED BRACKET THAT NEEDED REPLACED.SDR QXEA0100156Fitting · wornYYC- LOWER LEFT HAND AND RIGHT HAND FITTING ON ELEVATOR BOOST UNIT HAS PLAY. REPAIRED IAW FOKKER SRM 20-20-03 AND HORIZON AIR EA 4-55-280.SDR 20010208CW011Torque Tube · looseDURING SCHEDULED INSPECTION, RIGHT ELEVATOR WAS FOUND WITH EXCESSIVE, FREE PLAY,. LOOSENESS WAS THE RESULT OF LOOSE RIVETS ON TORQUE TUBE.SDR DL72W010024Skin · crackedA .375 INCH CRACK IN LOWER SKIN OF LT ELEVATOR I/B AND FWD OF TAB CONTROL ROD CUTOUT. REPAIRED PER SRM 55-20-3.SDR AT0100051Skin Panel · gougedFOUND RIGHT ELEVATOR LEADING EDGE GOUGED AT OUTBOARD END FROM OUTBOARD SEAL HARDWARE. REMOVED AND REPLACED LEADING EDGE SECTION, REPLACED SEAL ATTACH FASTENERS IAW TIMCO SERVICE ORDER 151151-23696.SDR CA010112015Structure · cracked(CAN) UNDER EACH HINGE BRACKET P/N 40042-09 (CENTRE) AND P/N 40042-08 (INBOARD) APPROXIMATELY 1 INCH CRACKS REINFORCING PLATE INSTALLED AFTER STOP DRILLING RE AC43 13-1B, FIGURE 4-21, PAGE 4-42.SDR 20010123CW007Hinge · corrodedDURING SCHEDULED MAINTENANCE, LT HAND OUTBOARD ELEVATOR HINGE BRACKET MOUNTED ON THE STABILIZER SHOWED SIGNS OF INTERGRANULAR CORROSION. REMOVED AND REPLACED LT ELEVATOR OUTBOARD HINGE.SDR 20010123CW006Hinge · corrodedDURING SCHEDULED MAINTENANCE, RT HAND OUTBOARD ELEVATOR HINGE BRACKET MOUNTED ON THE STABILIZER SHOWED SIGNS OF INTERGRANULAR CORROSION. REMOVED AND REPLACED RIGHT ELEVATOR OUTBOARD HINGE.SDR CALA0001930Frame · delaminatedINSPECTION FOUND THE RT ELEVATOR UPPER AND LOWER CHORD DELAMINATED. THE DELAMINATED AREAS WERE REPAIRED IAW SRM 51-70-17 AND ECRA 5523-01022.SDR CA010110012Structure · cracked(CAN) ON INSPECTION A SMALL CRACKED WAS NOTICED STARTING FROM THE ONE OF THREE BOLT HOLES ON THE HORN ASSEMBLY. A NEW R/H HORN ASSEMBLY WAS INSTALLED.SDR CA001229003Bracket · cracked(CAN) DURING ROUTINE INSPECTION CRACKS WERE FOUND ON THE BRACKET BALANCE WEIGHT ATTACHMENT. THESE CRACKS WERE LOCATED AT THE TOP AND BOTTOM ALONG THE BEND LINE.SDR RRXA010514Structure · damagedDURING A MAINTENANCE VISIT FOUND SHEET METAL DAMAGE TO O/B T/E OF THE RT ELEVATOR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 51-1-21 AND EO #00-306.SDR CA001205022Fitting · cracked(CAN) DURING SCHEDULED MAINTENANCE CRACKS WERE DISCOVERED EMANATING FROM THE TAPER PIN HOLES ON THE ELEVATOR TORQUE TUBE MIDDLE FITTINGS (BOTH SIDES). (ONE CRACK PER FITTING - TWO FITTING TOTAL). TAPER PINS WERE ALSO FOUND TO BEYOND THE .060 INCH MAX PROTRUSISDR 20001114SH027Bolt · brokenRIGHT ELEVATOR CENTER HINGE BOLT WAS FOUND BROKEN DURING A ROUTINE AIRCRAFT INSPECTION. IT LOOKED INTACT, BUT UPON A TORQUE CHECK, IT WAS FOUND THAT THE BOLT WAS BROKEN. THERE IS NO HISTORY OF UNUSUAL STRESSES ON THIS PART. (X)SDR 20010228CW004Skin · debondedDEBOND ON ALL HONEYCOMB STIFFENERS OF RIGHT ELEVATOR.SDR 20001127SH013Bracket · damagedWHILE RE-INSTALLING THE RIGHT ELEVATOR, THE MECHANIC NOTICED THE BOLT THAT HOLDS THE ELEVATOR OUTBOARD BRACKET TO THE HORIZONTAL BEARING BRACKET PN 50-620001-69 WAS SLOPPY. AFTER REMOVING BOLT, FOUND IT SEVERELY WORN AND BRACKET 50-61000-546 HAD SEVERELY ELONSDR AU001042Elevator · fod(AUS) RIGHT ELEVATOR DAMAGED BY YACHT. TRIM TAB DAMAGED. AIRCRAFT IS A FLOAT PLANE AND WAS MOORED AT THE TIME. (X)SDR DHL200080744CSkin · dentedAT C-CK; LT ELEVATOR T/E LWR SURFACE 1 INCH DENT STA XE 288,386 (INNER AREA). REMOVED T/E IAW SRM 51-1-21 PG 1, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED T/E IAW SRM 51-1-21, PG 1. REF: N/R 0719.SDR RRXA003224Stiffener · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE STIFFENERS ON THE WEB BELOW HORIZ STAB. CONSTANT SECTION AT STA 1810 INSIDE ACC 60, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR SWAA001855Skin · delaminatedDURING SCHEDULED 1/4D CHECK, FOUND RT ELEVATOR DELAMINATED AT LWR SKIN O/B SIDE. REMOVED AND REPLACED RT ELEVATOR PER MM.SDR 20001106SH045Bracket · gougedGOUGES ON RIGHT ELEVATOR HINGE BRACKET. (X)SDR GAIA00615Structure · crackedDISCREPANCY: DURING HEAVY CHECK FOUND: RIGHT HAND ELEVATOR HAS CRACKED INTERNAL STRUCTURECORRECTIVE ACTION: REMOVED & REPLACED SKIN PANEL ON RIGHT HAND ELEVATOR FROM STA 136.5 TO 173.21 IAW B727 SRM 51-10-1 & 51-30-2 (REF N/R 26571 FOR MORE DETAILS FOR SKIN ASSDR GAIA00614Structure · crackedDISCREPANCY: DURING HEAVY CHECK FOUND: RIGHT HAND ELEVATOR PNL HAS CRACKED INTERNAL STRUCTURE. CORRECTIVE ACTION: REMOVED & REPLACED PANEL IAW B727 SRM 51-30-2SDR GAIA00613Structure · crackedDISCREPANCY: DURING HEAVY CHECK FOUND: RIGHT HAND ELEVATOR HAS CRACKED INTERNAL STRUCTURECORRECTIVE ACTION: REMOVED & REPLACED SKIN PANEL ON RIGHT HAND ELEVATOR FROM STA 136.5 TO 173.21 IAW B727 SRM 51-10-1 & 51-30-2 (REF N/R 26571 FOR MORE DETAILS FOR SKIN ASSDR LR7A00172Counterweight · corrodedDURING SCHEDULED C1 INSPECTION PER JOB CARD HC2704, FOUND LT ELEVATOR COUNTER WEIGHT TOP SURFACE CORRODED. REPLACED WEIGHT ASSEMBLY PER SMP 583 51-10 PARA 4. SECURED PER SMP 581 91-00 PG 209, PARA 10 DRC 2029.SDR SWAA001662Fitting · corrodedDURING SCHEDULED D-CHECK, FOUND RT HORIZONTAL STAB NR 6 ELEVATOR HINGE FITTING HAS FRETTING CORROSION DAMAGE. REPAIRED FITTING PER ACO.SDR 00FDEA00615Wedge · corrodedRIGHT ELEVATOR MOST I/B TRAILING EDGE WEDGE FOUND CORRODED. CORROSION REMOVED. *S/D* REMOVED AND REPLACED PER FEDEX EA 6-2210-52050.
Back to JASC 5520