JASC 5531
Service difficulty reports · 1,234
Reports filed under 5531 · Vertical Stabilizer, Spar/Rib, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5531' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5531' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 03FDEA01902Spar · chafedVERTICAL STAB STRINGER 7 CHAFED UNDER AFT CORNER OF ACCESS PANEL 9601. REPAIRED DAMAGE TO LT VERTICAL FIN MID SPAR AT FIN STA 229 PER SRM 55-30-06 FIGURE 3.SDR AMWA73Rib · crackedWHILE PERFORMING AN INSPECTION IN THE VERTICAL STAB, TO THE RIB FLANGES AT CANTED STAB STA 54.026 WERE FOUND CRACKED IN THREE PLACES ON THE LEFT AND THREE PLACES ON THE RIGHT. REPAIRED CRACKS TO RIB FLANGE IN ACCORDANCE WITH BMM P/N 114-590021-9, 51-70-03.SDR AMWA72Rib · crackedWHILE PERFORMING AN INSPECTION IN THE VERTICAL STAB, THE RIB FLANGE AT CANTED STAB STA 39.289 WAS FOUND CRACKED ONCE ON THE RIGHT SIDE. REPAIRED CRACKS TO RIB FLANGE IN ACCORDANCE WITH BMM P/N 114-590021-9, 51-70-03.SDR AMWA71Rib · crackedWHILE PERFORMING AN INSPECTION IN THE VERTICAL STAB, THE RIB FLANGES AT CANTED STAB STA 69.184 WAS FOUND CRACKED, ONCE ON THE LEFT AND ONCE ON THE RIGHT SIDE. REPAIRED CRACKS TO RIB FLANGE IN ACCORDANCE TO BMM P/N 114-590021-9, 51-70-03.SDR AMWA70Rib · crackedWHILE PERFORMING AN INSPECTION IN THE VERTICAL STAB, THE RIB FLANGE AT CANTED STAB STA 69.184 WAS FOUND CRACKED AT FWD CENTER STRINGER INTERSECTION. REPAIRED CRACKS TO RIB FLANGE IN ACCORDANCE BMM P/N 114-590021-9, 51-70-03.SDR AMWA69Rib · crackedWHILE PERFORMING AND INSPECTION IN THE VERTICAL STAB, THE RIB FLANGE AT CANTED STAB STA 54.026 WAS FOUND CRACKED IN TWO PLACES ON THE RIGHT SIDE NEAR THE FWD, CENTER STRINGERS AND TWO PLACES ON THE LEFT. REPAIRED CRACKS TO RIB FLANGE IN ACCORDANCE WITH BMM P/SDR CA031106013Spar · cracked(CAN) DURING X-RAY INSPECTION OF THE VERTICAL STABILIZER, A CRACK WAS NOTED ON THE CENTER SPAR FLANGE LOCATED 2 FASTENERS UP FROM THE EXTERNAL DOUBLER APEX. THE CRACKIS APPROXIMATELY 5/8 - 3/4 INCH IN LENGTH AND RUNS 90 DEGREES TO THE FLANGE. A CRA CK APPROXIMSDR AMWA68Rib · cracked6 CRACKS ON THIS RIB. 3 ON LT AND 3 ON RT SIDES AT STRINGER TO RIB INTERSECTION. CRACKS LOCATED AT FIRST RIVET HOLE. LT STRINGER P/N 101-640000-37, 101-640000-39, 101-640000-45. RT STRINGER P/N 101-640000-38,101-640000-46, 101-640000-42SDR AMWA67Rib · cracked3 CRACKS FOUND ON THIS RIB AT STRINGER TO RIB INTERSECTION. 1 AT STRINGER P/N 101-640000-37 FIRST RIVET HOLE ON RIB RT SIDE. 1 LOCATED LT STRINGER 101-640000-39 AND 1 RT STRINGER 101-640000-42. BOTH AT FIRST RIVET HOLE OF RIB.SDR AMWA66Rib · cracked5 CRACKS LOCATED ON THIS RIB. 2LT AND 3 RT LOCATED AT STRINGER TO RIB INTERSECTIONS ON THE FIRST RIVET HOLE. RT STRINGER P/N 101-640000-38, 101-640000-42, 101-640000-46. LT STRINGER P/N 101-640000-39, 101-640000-37SDR UPS03841477Rib · crackedINSPECTION TYPE: C2, VERTICLE FIN LOWER L/E SECTION HAS A RT RIB CRACKED AT ZFS 98.250. STOPDRILLED CRACK, NDT VERIFIED STOPDRILL TERMINATES CRACK, FABRICATED AND INSTALLED REPAIR ANGLES AND FILLER IAW SRM 55-2-0 FIG 2.SDR AMWA82Rib · crackedWHILE PERFORMING AN INSPECTION IN THE VERTICAL STAB, THE RIB FLANGE AT CANTED STAB STA 39.289 WAS FOUND CRACKED ON THE LEFT SIDE NEAR THE FWD STRINGER INTERSECTION. REPAIRED CRACK TO RIB FLANGE IN ACCORDANCE WITH BMM P/N 114-590021-9, 51-70-03.SDR AMWA62Rib · crackedWHILE PERFORMING AN INSPECTION IN THE VERTICAL STAB, THE RIB FLANGES AT CANTED STAB 24.973 WERE FOUND CRACKED. REPAIRED CRACKS TO RIB FLANGE IN ACCORDANCE TO BMM P/N 114-590021-9, 51-70-03.SDR AMWA61Rib · crackedWHILE PERFORMING AN INSPECTION IN THE VERTICAL STAB, THE RIB FLANGE AT CANTED STAB STA 39.289 WAS FOUND CRACKED IN TWO PLACES ON THE RIGHT SIDE BY THE FOWARD AND AFT STRINGER INTERSECTION. REPAIRED CRACKS TO RIB FLANGE ACCORDANCE WITH BMM P/N 114-590021-9, 51SDR AMWA60Rib · crackedWHILE PERFORMING AN INSPECTION IN THE VERTICAL STAB, THE RIB FLANGE AT CANTED STAB STA 69.184 WAS FOUND CRACKED IN ONE PLACE ON THE RIGHT SIDE NEAR THE AFT STRINGER INTERSECTION AND TWO CRACKS ON THE LEFT SIDE AT THE FORWARD AND CENTER STRINGS INTERSECTIONS. SDR AMWA59Rib · crackedWHILE PERFORMING AN INSPECTION IN THE VERTICAL STAB, THE RIB FLANGE CANTED STAB STA 54.026 WAS FOUND CRACKED IN THREE PLACES ON THE RIGHT SIDE NEAR THE FORWARD, CENTER AND AFT STRINGERS AND TWO PLACES ON THE LEFT. REPAIRED CRACKS TO RIB FLANGE IN ACCORDANCE TSDR ABXA030408Rib · crackedLEFT SIDE OF REMOVABLE LEADING EDGE HAD A CRACK ON A RIB TOWARD THE TOP END OF THE PANEL. REPAIRED AREA IAW DC-9 SSRM DWG K05159.SDR ABXA030409Rib · crackedLEFT SIDE OF REMOVABLE LEADING EDGE HAD A CRACK ON A RIB IN THE MIDDLE OF THE PANEL. REPAIRED AREA IAW DC-9 SSRM DWG K05159.SDR ABXA030411Rib · crackedRIGHT SIDE OF REMOVABLE LEADING EDGE HAD A CRACK ON RIB IN THE MIDDLE OF THE PANEL. REPAIRED AREA IAW DC-9 SSRM DWG K05159.SDR ABXA030410Rib · crackedRIGHT SIDE OF REMOVABLE LEADING EDGE HAD A CRACK ON A RIB AT THE BOTTOM OF THE PANEL. REPAIRED AREA IAW DC-9 SSRM DWG K05159.SDR AMWA65Rib · crackedWHILE PERFORMING AN INSPECTION IN THE VERTICAL STAB, THE RIB FLANGE AT CANTED STAB STA 39.289 WAS FOUND CRACKED IN ONE PLACE ON THE RIGHT AND ONE PLACE ON THE LEFT SIDE NEAR THE CENTER STRINGER INTERSECTION. REPAIRED CRACK TO RIB FLANGE IN ACCORDANCE TO BMM PSDR AMWA64Rib · crackedWHILE PERFORMING AN INSPECTION IN THE VERTICAL STAB, THE RIB FLANGE AT CANTED STAB STA 69.184 WAS FOUND CRACKED IN ONE PLACE ON THE RIGHT SIDE NEAR AFT STRINGERS INTERSECTION REPAIRED CRACK TO RIB FLANGE IN ACCORDANCE TO BMM P/N 114-590021-9, 51-70-03.SDR AMWA63Rib · crackedWHILE PERFORMING AN INSPECTION IN THE VERTICAL STAB, THE RIB FLANGE AT CANTED STAB STA 54.026 WAS FOUND CRACKED IN THREE PLACES ON THE RIGHT SIDE NEAR THE FORWARD, CENTER AND AFT STRINGERS AND TWO PLACES ON THE LEFT. REPAIRED CRACKS TO RIB FLANGE IN ACCORDANCSDR UPS03841373Rib · crackedINSPECTION TYPE: C1, VERTICLE STAB LE RT RIB IS CRACKED AT ZFS 68. STOPDRILLED CRACK, NDT VERIFIED STOPDRILL TERMINATED CRACK,FABRICATED AND INSTALLED REPAIR ANGLE I.A.W. SRM. 55-2-0 FIG.2SDR AMWA55Rib · crackedFOUND TWO CRACKS ON RIB P/N 101-640000-59 AT THE RIVETS BESIDE THE STRINGERS INTERSECTIONS. THE STRINGER THAT INTERSECT THE RIB ARE P/N 101-640000-39 AND 101-640000-46. BOTH CRACKS WERE REAIRED IAW THE MFG STRUCTURAL REPAIR MANUAL.SDR 2003FA0001048Spar · crackedDURING COMPLIANCE WITH AD 78-08-03, FOUND CRACKS IN THE UPPER HINGE REINFORCEMENT BRACKET (PN 17067-18) OF THE VERTICAL STABILIZER. REMOVAL OF THE BRACKET WAS PERFORMED AND A CLOSE INSPECTION OF THE BOLT HOLES IN THE REAR SPAR FOR THE UPPER RUDDER HINGE CASTISDR AMWA57Rib · crackedFIVE CRACKS FOUND IN THE RIB IN JOGGLED PARTS OF RIB AT STRING INTERSECTIONS. STRING P/N 101-640000-46, 101-640000-39, 101-640000-45, 101-640000-38. CRACKS RUN HORIZONTAL TO RIB FROM LAST RIVET HOLE TO EDGE OF RIB.SDR AMWA56Rib · cracked2 CRACKS FOUND IN THE RIB. IN JOGGLED SECTION OVER STRNG AT LAST RIVET. CRACKS LOCATED AT STRNG P/N 101-640000-37 AND 10-640000-46.SDR AMWA46Rib · crackedRIB AT CSS 39.289 CRACKED AT STRG P/N 101-640000-46 (1EA CRACK ON THIS RIB)SDR AMWA45Rib · crackedRIB AT CSS 54.026 CRACKED AT STRG P/N 101-640000-37 AND STRG P/N 101-640000-39 (2EA CRACKS ON THIS RIB).SDR AMWA41Rib · crackedRIB AT CSS 39.289 CRACKED AT STRG P/N 101-640000-37 LT SIDE (1EA CRACK ON THIS RIB)SDR AMWA40Rib · crackedRIB AT CSS 54.026 CRACKED AT STRG P/N 101-640000-47 STRG P/N 101-640000-46 ON RT SIDE STRG P/N 101-640000-41 STRG P/N 101-640000-37 LT SIDE (4EA CRACK ON THIS RIB).SDR AMWA39Rib · crackedRIB 69.184 CS CRACKED AT STRG P/N 101-640000-45 (1EA CRACK ON THIS RIB) LT SIDE.SDR AMWA38Rib · crackedRIB AT CS 24.973 CRACKED AT STRG P/N 101-640000-39 LT SIDE (1EA CRACK ON THIS RIB).SDR AMWA37Rib · crackedRIB AT CSS 39.289 CRACKED AT STRG P/N 101-640000-45 STRG P/N 101-640000-39 (2EA CRACKS ON THIS RIB)SDR AMWA36Rib · crackedRIB AT CSS 54.026 CRACKED AT STRG P/N 101-640000-47 STRG P/N 101-640000-42 STRG P/N 101-640000-46 LT SIDE (3EA CRACKS ON THIS RIB)SDR AMWA35Rib · crackedRIB AT CSS 39.289 AT STRG P/N 101-640000-47 STRG P/N 101-640000-42 ON RH SIDE AND STRG P/N 101-640000-39 STRG P/N 101-640000-37 (4EA CRACKS ON THIS RIB)SDR AMWA34Rib · crackedRIB AT CSS 54.026 CRACKED AT STRG. 101-640000-47 STRG. P/N 101-640000-42 RT SIDE AND STRG 101-640000-43 STRG P/N 101-640000-39 STRG P/N 10164000041 5 EA CRACKS ON THIS RIB)SDR AMWA33Rib · crackedRIB CRACKED AT CSS 69.184 AT STRG P/N 101-640000-46 RT AND STRG P/N 101-640000-45 LT SIDE (2EA CRACK AT THIS RIB).SDR AMWA32Rib · crackedRIB AT CS 54.026 CRACKED AT STRG. P/N 101-640000-46 STRG P/N 101-640000-47 ON RT SIDE AND STRG P/N 101-640000-39 LT SIDE (3EA CRACKS ON THIS RIB).SDR AMWA31Rib · crackedRIB AT CSS 39.289 CRACKED AT STRG P/N 101-640000-39, 1EA CRACK AT THIS RIB.SDR AMWA48Rib · cracked6 CRACKS FOUND ON THIS RIB LOCATED AT END RIVET OF RIB AREA THAT IS JOGGLED OVER STRG. STRG INTERSECTION LH P/N 101-640000-37, LT 101-640000-39, LH P/N101-640000-45 THEN RH P/N 101-640000-38, RH P/N 101-640000-46, RH P/N 101-640000-42.SDR AMWA47Rib · cracked2 CRACKS FOUND ON RIB NR 1 ON LT SIDE AT STRINGER INTERSECTION STRINGER P/N 101-64000-37 AND 1 ON RH SIDE AT STRG P/N 101-640000-46. CRACKS LOCATED AT THE END RIVET ON JOGGLE OVER STRINGER BOTH LOCATIONSSDR AMWA54Rib · crackedWHILE PERFORMING INSP IN THE VERTICAL STAB., THE RIB FLNAGE AT CANTED STAB. STA 39.289 WAS FOUND CRACKED IN ONE PLACE ON THE LT SIDE AT THE CENTER STRG,. REPAIRED CRACK TO RIB FLANGE ACCORDANCE TO BEECH SRM P/N 114-590021-91, 51-70-03SDR AMWA53Rib · crackedWHILE PERFORMING INSP IN THE VERTICAL STAB., THE RIB FLNAGE AT CANTED STAB. STA 39.289 WAS FOUND CRACKED IN ONE PLACE ON THE RT SIDE AT THE FWD SIDE,. REPAIRED CRACK TO RIB FLANGE ACCORDANCE TO BEECH SRM P/N 114-590021-91, 51-70-03SDR AMWA52Rib · crackedWHILE PERFORMING INSP IN THE VERT. STAB., THE RIB FLNAGE AT CANTED STAB. STA 54.026 WAS FOUND CRACKED IN THREE PLACES ON THE RT SIDE NEAR THE FWD, CENTER, AND AFT STRG. REPAIRED CRACKS TO RIB FLANGE ACCORDANCE TO BEECH SRM P/N 114-590021-9, 51-70-03SDR AMWA51Rib · crackedWHILE PERFORMING INSP IN THE VERTICAL STAB., THE RIB FLANGE AT CANTED STAB. STA 69.184 WAS FOUND CRACKED IN ONE PLACE ON THE LT SIDE AT THE AFT STRG INTERSECTION AND ONE PLACE ON THE RT. REPAIRED CRACKS TO RIB FLANGE IN ACCORDANCE WITH BEECH SRM P/N 114-590021SDR AMWA50Rib · crackedWHILE PERFORMING AN INSP IN THE VERT. STAB., THE RIB FLANGE AT CANTED STAB. STA 54.026 WAS FOUND CRACKED IN 3 PLACES ON THE RT SIDE NEAR THE FWD, CENTER AND AFT STRG AND 2 PLACES ON THE LT. REPAIRED CRACKS TO THE RIB FLANGE IN ACCORDANCE TO BEECH SRM P/N 114-5SDR AMWA44Rib · crackedRIB AT CSS 39.289 CRACKED AT STRG P/N 101-640000-46, STRG 101-640000-42 ON RT SIDE AND STRG P/N 101-640000-41, STRG P/N 101-640000-37 (4EA CRACKS TOTAL ON THIS RIB)SDR AMWA43Rib · crackedRIB AT CSS 69.184 CRACKED AT STRG P/N 101-640000-46 STRG P/N 101-640000-42 BOTH RT SIDE AND STRG P/N 101-640000-37 STRG P/N 101-640000-45 ON LT SIDE (4 EA TOTAL CRACKS ON THIS RIB)
Back to JASC 5531