JASC 5553
Service difficulty reports · 586
Reports filed under 5553 · Vertical Stabilizer, Attach Fittings, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5553' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5553' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA070627Lug · corrodedVERT FWD FACE OF LUG R4 ON FUSELAGE AT 4:00 POSITION HAS CORROSION. REMOVED CORROSION REAMED BORE, CHAMFERED EDGES, INSTALLED NEW BUSHING PER EA 98800; CORR TASK C55-70, DEFECT SIZE: .25 INCH.SDR USAA070634Bushing · corrodedBUSHING & FLANGE, VERT AFT FACE OF R5 LUG ON FUSELAGE AT 5:00-9:00 POSITION HAS CORROSION. REPLACE FLANGE BUSHING, BLENDED FLANGE TO REMOVE DAMAGE TREATED PER EA 98800; CORR TASK C55-706-01, DEFECT SIZE: .25 INCH.SDR USAA070625Bushing · corrodedRIGHT AFT I/B ATTACH FITTING FUW FACE OF BUSHING PITTED & CORRODED, R-8 LUG. REMOVED BUSHING, LUG BORE, FACES CLEANED, INSTALLED NEW BUSHING PER EA 98801; CORR TASK C55-706-11, DEFECT SIZE: .250 X .250 INCH.SDR TRAX200701091Attach Angle · crackedLEFT VERTICAL STABILIZER TO FUSELAGE ATTACH ANGLE HAS SUSPECT CRACK AFT. PERFORMED ET INSPECTION OF SUSPECT AREA IAW CRJ 700 NDTM 51-20-006. ATTACH ANGLE IS CRACKED. PERFORMED EDDY CURRENT INSPECTION OF LEFT VERTICAL STABILIZER TO FUSELAGE ATTACH ANGLE TO DSDR SWAA073434Fitting · corrodedDURING SCHEDULED 18Y CHECK, FOUND VERTICAL FIN PRIMARY FITTING CLEVIS LUGS CORRODED. REPAIRED FITTING CLEVIS LUGS PER ER.SDR SWAA073042Fitting · corrodedDURING SCHEDULED BRDG CHECK, FOUND VERTICAL STAB FITTING FWD AND AFT CLEVIS LUG FACES CORRODED. REPAIRED FITTING PER ER.SDR CALA0700304Fitting · corrodedINSPECTION FOUND VERTICAL STABILIZER LEFT AFT LUG FAILSAFE FITTING CORRODED AT STA 1088-1104. THE FITTING WAS REMOVED AND REPLACED IAW SRM 51-40-02.SDR CALA0700303Fitting · corrodedINSPECTION FOUND VERTICAL STABILIZER LEFT AFT I/B ATTACH LUG FORWARD FAILSAFE FITTING CORRODED ON FORWARD SIDE, STA 1088-1104. THE FAILSAFE FITTING WAS REMOVED AND REPLACED IAW SRM 51-40-02.SDR 07FDEA02075Attach Fitting · corrodedVERT STAB REAR SPAR RT UPPER MOST HINGE ATTACH FITTING HAS CORROSION. REMOVED HINGE FITTING IAW SRM 51-40-21. LOCATED AND DRILLED NEW FITTING IAW SRM 51-40- 44. INSTALLED NEW FITTING IAW SRM 51-40-21. INSTALLED NEW STRINGER CLIPS 1/2 AT RIB 25 IAW N/R S000SDR 07FDEA02074Attach Fitting · corrodedVERT STAB REAR SPAR RT UPPER MOST HINGE ATTACH FITTING HAS CORROSION. REMOVED HINGE FITTING IAW SRM 51-40-21. LOCATED AND DRILLED NEW FITTING IAW SRM 51-40-44. INSTALLED NEW FITTING IAW SRM 51-40-21. INSTALLED NEW STRINGER CLIPS 1 AND 2 AT RIB25 IAW N/R S0SDR UPS07849611Attach Angle · crackedINSPECTION TYPE:C2 ATTACH ANGLE FOR VERT FIN L/E TO FUSELAGE BENT AND CRACKED RIGHT SIDE FS 1690. REMOVED ATTACH ANGLE FOR VERT FIN TO FUSELAGE AT STA 1690 IAW SRM 51-3-0. FABRICATED AND INSTALLED ANGLE DOUBLER AND FILLER AT FS 1690 VERT FIN L/E TO FUSELAGE SDR TRAX200700102Attach Angle · crackedRT VERTICAL STAB TO FUSELAGE ATTACH ANGLE IS CRACKED AT AFT END. REPAIR OF RT VERTICAL STAB TO FUSELAGE ANGLE IAW REO 670-55-31-017.SDR ASAA0741363Attach Angle · crackedVERTICAL STABLIZER AT REAR SPAR AREA PANEL ATTACH ANGLE CRACKED AT APPROX FIN STA 140. VERTICAL STABLIZER REAR SPAR TO SKIN PANEL ATTACH ANGLE AT FIN STATION 140 REPLACED IAW SRM 51-40-02.SDR SWAA064796Fitting · corrodedDURING SCHEDULED 20Y CHECK, FOUND LT VERTICAL STAB FITTING PRIMARY LUG FACE CORRODED. REPAIRED STAB FITTING PER ER.SDR SWAA064407Fitting · corrodedDURING SCHEDULED 18Y CHECK, FOUND VERTICAL STAB FAIL-SAFE FITTING LT AND RT LUG FACES CORRODED. REPAIRED VERTICAL STAB FAIL-SAFE FITTING PER ER.SDR SWAA064406Attach Fitting · corrodedDURING SCHEDULED 18Y CHECK, FOUND VERTICAL STAB ATTACH FITTING LT AND RT CLEVIS LUG FACES CORRODED. REPAIRED VERTICAL STAB PER ER.SDR TRAX200601019Drag Angle · crackedLEFT SIDE VERTICAL STAB-TO-FUSELAGE DRAG ANGLE CRACKED (MARKED). REPAIRED IAW ALL SRM`S AND MM`S. (CLOSED)SDR MWEA060198Attach Angle · damagedTASK 99 ZONE 63, REPLACE DORSAL FIN ATTACHMENT ANGLE. REPLACED DORSAL FIN ATTACHMENT ANGLES.SDR MWEA060197Angle · damagedTASK 99 ZONE 63 REPLACE DORSAL FIN ATTACHMENT ANGLE. REPLACED DORSAL FIN ATTACH ANGLES.SDR SWAA063390Fitting · corrodedDURING SCHEDULED 20Y CHECK, FOUND VERTICAL STAB FITTING AFT LUG FACE CORRODED. REMOVED AND REPLACED VERTICAL STAB FITTING PER SRM.SDR SWAA063389Fitting · corrodedDURING SCHEDULED 20Y CHECK, FOUND VERTICAL STAB FITTING FWD LUG FACE CORRODED. REMOVED AND REPLACED VERTICAL STAB FITTING PER SRM.SDR SWAA062456Bushing · wornDURING SCHEDULED C3 CHECK, LT ELEVATOR TAB FAILED FREEPLAY CHECK. REMOVED AND REPLACED LT ELEVATOR INBOARD TAB BUSHING AND BOLT PER MM.SDR 06FDEA2493Fitting · damagedFOUND VERT FIN "C" SHAPED SHEAR FITTING TO HAVE 3 "SNOWMAN" HOLES. REMOVED AND REPLACED VERT FIN "C" SHAPED SHEAR FITTING IAW SRM 51-30-2, 51-30-5SDR MWEA060199Attach Angle · crackedTASK 99 ZONE 63 RIGHT AFT FUSELAGE DORSAL FIN ATTACH ANGLE HAS A CRACK IN VERTICAL LEG 6 INCHES FORWARD OF AFT EDGE. FABRICATED AND INSTALLED ANGLE.SDR 2006FA0000416Fitting · crackedPART ATTACHES VERTICLE STABILIZER SPAR TO THE HORIZONTAL STABILIZER SPAR ATTACH FITTING P/N 0432004-9(THIS FITTING HAS BEEN THE SUBJECT OF AD 80-11-04 AND SEB 3-06)PROBABLE CAUSE IS HIGH ACTT. AGING AIRCRAFT REQUIRE DILIGENT INSPECTIONS. (REF FAA HANDBOOK"BESTSDR 2006FA0000402Fitting · crackedPART ATTACHES VERTICAL STABILIZER SPAR TO THE HORIZONTAL STABILIZER SPAR ATTACH FITTING P/N 0432004-9(THIS FITTING HAS BEEN THE SUBJECT OF AD 80-11-04 AND SEB 3-06)PROBABLE CAUSE IS HIGH ACTT. AGING AIRCRAFT REQUIRE DILIGENT INSPECTIONS. (REF FAA HANDBOOK"BESTSDR 2006FA0000401Fitting · crackedPART ATTACHES VERTICLE STABILIZER SPAR TO THE HORIZONTAL STABILIZER SPAR ATTACH FITTING P/N 0432004-9(THIS FITTING HAS BEEN THE SUBJECT OF AD 80-11-04 AND SEB 3-06)PROBABLE CAUSE IS HIGH ACTT. AGING AIRCRAFT REQUIRE DILIGENT INSPECTIONS. (REF FAA HANDBOOK"BESTSDR SWAA061337Drag Brace · corrodedDURING SCHEDULED 10Y CHECK, FOUND RT VERTICAL STAB RT AFT DRAG BRACE CORRODED. REMOVED AND REPLACED RT DRAG BRACE PER SRM.SDR 06FDEA1257Attach Angle · corrodedUPPER FUSELAGE RT FWD ATTACH ANGLE FOE DORSAL FIN HAS CORROSION. REMOVED AND REPLACED ANGLE IAW A310-200 SRM 51-72-10 AND A310-200 SRM 51-40-21.SDR 06FDEA1256Attach Angle · corrodedUPPER FUSELAGE RT FWD ATTACH ANGLE FOR DORSAL FIN HAS CORROSION. REMOVED AND REPLACED ATTACH ANGLE IAW A310-200 SRM 51-72-10 AND A310-200 SRM 51-40-21.SDR 2006UALA00561Attach Angle · corrodedVERTICAL STAB LEF ATTACH AT AFT SPAR FWD & AFT DRAG ANGLES ARE CORRODED AT PRIMARY (O/B) BOLT HOLES. VERTICAL STAB L-H AFT SPAR FWD AND AFT DRAGE ANGLE CORROSION WAS REPAIRED PER AAR EO I060139.SDR 2006UALA00547Attach Fitting · corrodedVERTICAL STAB RIGHT AFT FUSE ATTACH FITTING OUTBOARD CLEVIS AFT LUG HAS CORROSION IN BORE & ON FWD & AFT FACES. VERTICAL STAB RIGHT AFT FUSE ATTACH FITTING OUTBOARD CLEVIS AFT LUG WAS REPAIRED PER AAR EA I060130. CORROSION WAS REMOVED AND NEW BUSHINGS FABRICSDR SWAA060921Fitting · corrodedDURING SCHEDULED 10Y CHECK, FOUND LT & RT VERTICAL STAB ATTACH FITTING FWD & AFT PRIMARY CLEVIS LUG FACES CORRODED. REPAIRED LUG FACES PER BFG ER.SDR SWAA060897Fitting · corrodedDURING SCHEDULED 10Y CHECK, FOUND LT & RT VERTICAL STAB ATTACH FITTING FWD & AFT PRIMARY CLEVIS LUG FACES CORRODED. REPAIRED LUG FACES PER BFG ER.SDR GUUA03020602Bracket · corrodedAT SCHEDULED ROUTINE MAINTENANCE, VERTICAL FIN UPPER RUDDER HINGE BRACKET SHOWS SIGNS OF EXFOLIATION. REPLACED UPPER RUDDER HINGE BRACKET.SDR SWAA060573Fitting · corrodedDURING SCHEDULED D CHECK, FOUND VERTICAL STAB ATTACH FITTING LT AND RT PRIMARY CLEVIS LUG FACES CORRODED. REPAIRED LUG FACES PER BFG ER.SDR QXEA200600512Attach Fitting · gougedYYC C3 FUSELAGE EXTERIOR LOWER VERTICAL STAB ATTACH CHORD HAS GOUGE TOP RIGHT HAND SIDE AT 61.56 PERCENT STRINGER DATUM VERTICAL. REPAIRED IAW REO 670-53-71-006.SDR SIMA200604105Bushing · migratedDURING HMBV INSPECTION FOUND HORIZONTAL STABILIZER TO VERTICAL STABILIZER NR 3 BUSHING TO BE MIGRATING. INSTALLED NEW BUSHING IAW SRM AND REINSTALLED STABILIZER IAW SRM. AIRCRAFT WAS RETURNED TO SERVICE. (K)SDR USAA060086Clevis · corrodedFOUND CORROSION VERTICAL STAB INNERSPAR BOX. REMOVED CORROSION AND INSTALLED REPAIR PARTS AS REQUIRED IAW SRM 51-20-01 BOEING DWG 65-53744 DEFECT SIZE:SDR USAA060085Clevis · corrodedFOUND VERTICAL STAB INNERSPAR BOX. REPLACED WITH IDENTICAL PART, REPLACED CLEVIS IAW BOEING DWG 65-53744 AND SRM 51-20-01, DEFECT SIZE: UNKNOWN.SDR USAA060088Clevis · corrodedFOUND CORROSION VERTICAL STAB INNERSPAR BOX. REMOVED CORROSION AND INSTALLED REPAIR PARTS IAW BOEING DWG 65-53744 AND 737/400 SRM 51-20-01 DEFECT SIZE:SDR 06FDEA0212Attach Fitting · corrodedFOUND PITTING IN THE LT FWD VERTICAL BOLT HOLE ON THE VERTICAL FIN TENSION TIE ATTACH FITTING (A/C SIDE).SDR SWAA060101Fitting · corrodedDURING SCHEDULED D-CHECK, FOUND VERTICAL STAB ATTACH FITTING LT & RT PRIMARY CLEVIS LUG FACES CORRODED. REPAIRED LUG FACES PER BFG ER.SDR SWAA053715Fitting · corrodedDURING SCHEDULED D CHECK, FOUND LT AND RT VERTICAL STAB ATTACH FITTING FWD AND AFT PRIMARY CLEVIS LUG FACES CORRODED. REPAIRED LUG FACES PER BFG ER.SDR SWAA053507Angle · corrodedDURING SCHEDULED D-CHECK, FOUND VERTICAL STAB FITTING RIGHT AFT DRAG ANGLE CORRODED. REMOVED AND REPLACED DRAG ANGLE PER SRM.SDR C2XA05TY058Fitting · wornTYS, DURING A SCHEDULE INSPECTION THE RIGHT HAND VERTICAL BEARING WAS FOUND WITH EXCESSIVE PLAY. MAINTENANCE REMOVED THE BEARING REAMED THE HOLE, INSTALLED BUSHING AND REPLACED THE BEARING IAW EC5510-01128.SDR SWAA053275Attach Fitting · corrodedDURING SCHEDULED D CHECK, FOUND VERTICAL STAB ATTACH FITTING LUG FACES CORRODED. REPAIRED LUG FACES PER BFG ER.SDR SWAA053154Fitting · corrodedDURING SCHEDULED D-CHECK, FOUND LT & RT VERTICAL STAB ATTACH FITTINGS CLEVIS LUG FACES CORRODED. REPAIRED LUG FACES PER BFG ER.SDR SWAA053063Fitting · corrodedDURING SCHEDULED D CHECK, FOUND LT AND RT VERTICAL STAB ATTACH FITTINGS CLEVIS LUG FACES CORRODED. REPAIRED LUG FACES PER BFG ER.SDR SWAA052953Fitting · corrodedDURING SCHEDULED D CHECK, FOUND LT AND RT VERTICAL STAB ATTACH FITTINGS CLEVIS LUG FACES CORRODED. REPAIRED LUG FACES PER BFG ER.
Back to JASC 5553