SDR USAA2009010690039Anchor Fitting · corrodedSAL C7 MAJOR REPAIR NR 6142519 CORROSION ON LOWER SURFACE OF RT MLG ANCHORAGE FITTING. REPAIRED RT MLG ANCHORAGE FITTING IAW US AIRWAYS EA NR 132186.SDR SWAA086949Lug · corrodedDURING SCHEDULED MV3 CHECK, FOUND RT MLG FWD TRUNNION BEARING FITTING O/B LOWER LUG CORRODED. REPAIRED LUG PER SWA EA.SDR SWAA086948Lug · corrodedDURING SCHEDULED MV3 CHECK, FOUND RT MLG FWD TRUNNION BEARING FITTING O/B UPPER LUG CORRODED. REPAIRED LUG PER SWA EA.SDR SWAA086947Lug · corrodedDURING SCHEDULED MV3 CHECK, FOUND LT MLG FWD TRUNNION BEARING LOWER I/B LUG CORRODED. REPAIRED LUG PER SWA EA.SDR SWAA086946Lug · corrodedDURING SCHEDULED MV3 CHECK, FOUND RT MLG FWD TRUNNION BEARING FITTING I/B LOWER LUG CORRODED. REPAIRED LUG PER SWA EA.SDR SWAA086945Lug · corrodedDURING SCHEDULED MV3 CHECK, FOUND LT MLG FWD TRUNNION BEARING UPPER I/B LUG CORRODED. REPAIRED LUG PER SWA EA.SDR SWAA086944Lug · corrodedDURING SCHEDULED MV3 CHECK, FOUND RT MLG FWD TRUNNION BEARING FITTING I/B UPPER LUG CORRODED. REPAIRED LUG PER SWA EA.SDR SWAA086943Lug · corrodedDURING SCHEDULED MV3 CHECK, FOUND LT MLG FWD TRUNNION BEARING O/B LOWER LUG CORRODED. REPAIRED LUG PER SWA EA.SDR SWAA086942Lug · corrodedDURING SCHEDULED MV3 CHECK, FOUND LT MLG FWD TRUNNION BEARING O/B UPPER LUG CORRODED. REPAIRED LUG PER SWA EA.SDR SWAA086562Fitting · corrodedDURING SCHEDULED MV3 CHECK, FOUND RT MLG FWD UPPER I/B TRUNNION FITTING LUGS CORRODED. REPAIRED FITTING PER SWA EA.SDR SWAA086561Fitting · corrodedDURING SCHEDULED MV3 CHECK, FOUND LT MLG FWD UPPER I/B TRUNNION FITTING LUGS CORRODED. REPAIRED FITTING PER SWA EA.SDR DHLA2009743DH663Beam · corrodedRT WING TRAILING EDGE SECTION MAIN LANDING GEAR WALKING BEAM HOLES WITH CORROSION INCLUDING LOWER SURFACE. REPAIRED RT MLG WALKING BEAM HOLES AND LOWER SURFACE DUE TO CORROSION IAW EO C00-2-57-436-08 DTD 11/28/08 AND MESSAGE NR 1-1087194336-2 DTD 11/26/08 DOCSDR DHLA2008745697Support Beam · corrodedLT MLG TRUNNION SUPPORT BEAM OTBD ATTACH LUG BORE CORRODED AND ATTACH FITTING BORE'S SCRATCHED AND CORRODED. ACCOMPLISHED REPAIR TO TRUNNION BEAM BORE AND ATTACH FITTING BORES IAW COOPESA EO COO-2-57-376-08 DATED 10/23/08 AND BAC MSG 1-986112769-7 DATED 10/23SDR DHLA2008745691Support Beam · corrodedRT MLG TRUNNION SUPPORT BEAM OTBD ATTACH LUG BORE AND ATTACH FITTING BORE CORRODED AND SCRATCHED. REPAIRED RT MLG BEAM OTBD LUG BORE AND ATTACH FITTING (REAR SPAR) BORE IAW COOPESA EO COO-2-57-376-08 DATED 10/23/08 AND BOEING MESSAGE 1-986112769-7 DATED 10/22SDR SWAA086250Lug · corrodedDURING SCHEDULED MV2 CHECK, FOUND RT MLG FWD TRUNNION LOWER LUG CORRODED. REPAIRED LUG PER SWA EA.SDR SWAA086249Lug · corrodedDURING SCHEDULED MV2 CHECK, FOUND LT MLG FWD TRUNNION UPPER LUG CORRODED. REPAIRED LUG PER SWA EA.SDR 2008FA0000862Bracket · crackedA 1.4 INCH LONG CRACK WAS FOUND IN THE RT MLG DRAG BRACE SUPPORT BRACKET DURING INSPECTION. DURING THE REMOVAL OF THE PART (2) ADDITIONAL CRACKS 1.4 INCH LONG WERE FOUND AROUND 4 FASTENERS WHERE THE BRACKET ATTACHES TO THE MAIN SPAR WEB. WHEN INSTALLED, THE SDR DHLA2008745692Support Beam · corrodedRIGHT MLG TRUNNION BEAM LOWER FAIRING PANEL ATTACH HOLES CORRODED. ACCOMPLISHED REPAIR TO SUSPECT HOLES IAW EO COO-2-57-391-08 DATED 10/27/08. REF FAA FORM 8110-3 DATED 11/06/08 AND EVA B257-00059 FOR REPAIR APPROVAL. DOCUMENTED ON N/R 1-661.SDR DHLA2008745694Support Beam · corrodedLT MLG TRUNNION SUPPORT BEAM HAS CORROSION IN AND AROUND LOWER PANEL ATTACH HOLES, LWBL 80.5 TO 124.2. ACCOMPLISHED REPAIR TO SUPPORT BEAM AS REQUIRED, IAW COOPESA EO COO-2-57-387-08 DATED 10/27/08. REF FAA FORM 8110-3 DATED 11/06/08 AND ASTAR EVA B257-00060SDR SWAA086244Lug · corrodedDURING SCHEDULED MV2 CHECK, FOUND RT MLG LOWER FITTING LUG CORRODED. REPAIRED LUG PER SWA EA.SDR DHLA2008745686Fitting · damagedMODIFICATION OF LMLG TRUNNION SUPPORT BEAM OTBD FITTING, ON REAR SPAR, REQUIRED IN CONJUNCTION WITH FITTING BORE RE-WORK. ACCOMPLISHED MODIFICATION TO FITTING IAW SB 727-57-0153 REV 4 SECTION 3, PART II, DATED 9/10/92. DOCUMENTED ON COOPESA N/R 1-686.SDR DHLA2009743DH664Support Beam · damagedRT WING TRAILING EDGE MAIN LANDING GEAR SUPPORT BEAM AFT LOWER FLANGE WITH DOUBLE HOLE AT WS 251. REPAIRED RT MLG SUPPORT BEAM LOWER FLANGE AT WS 251 IAW COOPESA EO COO-2-57-436-08 DTD 11/28/08 AND BOEING MESSAGE NR 1-1087194336-2 DTD 11/26/08 DOCUMENTED ON FSDR SWAA085948Fitting · crackedDURING SCHEDULED 20Y CHECK, FOUND LT MLG FITTING CRACKED AT D-HOLE. REPAIRED FITTING PER PAE ER.SDR SWAA085791Fitting · corrodedDURING SCHEDULED MV3 CHECK, FOUND RT MLG FWD TRUNNION FITTING LUGS CORRODED. REPAIRED FITTING PER SWA EA.SDR SWAA085790Fitting · corrodedDURING SCHEDULED MV3 CHECK, FOUND LT MLG FWD TRUNNION FITTING LUGS CORRODED. REPAIRED FITTING PER SWA EA.SDR SWAA085586Bearing · corrodedDURING SCHEDULED MV2 CHECK, FOUND LT MLG AFT TRUNNION BEARING INNER RACE SURFACE CORRODED. REMOVED AND REPLACED BEARING PER MM.SDR SWAA085585Attach Fitting · corrodedDURING SCHEDULED MV2 CHECK, FOUND LT MLG FWD TRUNNION BEARING ATTACH FITTING LUG FACE CORRODED. REPAIRED FITTING PER SWA EA.SDR SWAA085584Bearing · corrodedDURING SCHEDULED MV2 CHECK, FOUND RT MLG AFT TRUNNION BEARING RACE INNER SURFACE CORRODED. REMOVED AND REPLACED BEARING PER MM.SDR SWAA085540Trunnion · corrodedDURING SCHEDULED MV2 CHECK, FOUND RT MLG TRUNNION FITTING CORRODED. REPAIRED PER FITTING PER SWA EA.SDR SWAA085539Fitting · corrodedDURING SCHEDULED MV2 CHECK, FOUND LT MLG TRUNNION FITTING CORRODED. REPAIRED PER FITTING PER SWA EA.SDR 08FDEA04254Trunnion · damagedRIGHT MLG TRUNNION ATTACHMENT POINT HINGE ARM FITTING DOES NOT TAKE GREASE.. REMOVED GREASE SUPPLY DUCT IAW MESSIER DOWTY CMM 32-16-12. RECOMDITIONED TRUNNION PIN & SUPPLY DUCT PIN HOLE " E " IAW CMM 32-16-12. HOLE SIZE AFTER RECONDITIONING IS 1.2685. WITHISDR AALA200802486Trunnion · corrodedRT MLG TRUNNION FITTING CORRODED AT UPPER INBD HOLE OUTER FACE. AREA OF DISCREPANCY IS 2 INCHES BY 2 INCHES WITH A .127 INCH DEPTH. REMOVED CORROSION, TREATED, PRIMED AND INSTALLED NEW BUSHING PER SRM 57-20-90-R2-2.SDR USAA200802485Trunnion · corrodedTUL LT MLG TRUNNION FITTING CORRODED AT LOWER OTBD HOLE OUTER FACE. AREA OF DISCREPANCY IS 2 INCHES BY 2 INCHES WITH A .042 INCH DEPTH. REMOVED CORROSION, TREATED, PRIMED, AND INSTALLED NEW BUSHING PER SRM 57-20-90-R2-2.SDR AALA200802484Trunnion · corrodedLT MLG TRUNNION FITTING CORRODED AT LOWER INBD HOLE OUTER FACE. AREA OF DISCREPANCY IS 2 INCHES BY 2 INCHES WITH A .084 INCH DEPTH. REMOVED CORROSION, TREATED, PRIMED, AND INSTALLED NEW BUSHING PER SRM 57-20-90-R2-2.SDR AALA200802483Trunnion · corrodedRT MLG TRUNNION FITTING CORRODED AT UPPER OTBD HOLE OUTER FACE. AREA OF DISCREPANCY IS 2 INCHES BY 2 INCHES WITH A .107 INCH DEPTH. REMOVED CORROSION, TREATED, PRIMED AND INSTALLED NEW BUSHING PER SRM 57 20-90-R2-2.SDR AALA200802482Trunnion · corrodedTUL RT MLG TRUNNION FITTING CORRODED AT LOWER OTBD HOLE OUTER FACE. AREA OF DISCREPANCY IS 2 INCHES BY 2 INCHES WITH A .142 INCH DEPTH. REMOVED CORROSION, TREATED, PRIMED, AND INSTALLED NEW BUSHING PER SRM 57-20-90-R2-2.SDR AALA200802481Trunnion · corrodedTUL LT MLG TRUNNION FITTING CORRODED AT UPPER INBD HOLE OUTER FACE. AREA OF DISCREPANCY IS 2 INCHES BY 2 INCHES WITH A .119 INCH DEPTH. REMOVED CORROSION, TREATED, PRIMED, AND INSTALLED NEW BUSHING PER SRM 57-20-90-R2-2.SDR AALA200802480Trunnion · corrodedTUL RT MLG TRUNNION FITTING CORRODED AT LOWER INBD HOLE OUTER FACE. AREA OF DISCREPANCY IS 2 INCHES BY 2 INCHES WITH A .120 INCH DEPTH. REMOVED CORROSION, TREATED, PRIMED, AND INSTALLED NEW BUSHING PER SRM 57-20-90-R2-2.SDR AALA200802603Trunnion · corrodedCORROSION FOUND ON LEFT MAIN LANDING GEAR TRUNNION AT UPPER OUTBOARD HOLE OUTER FACE. AREA OF DISCREPANCY IS .076 BY 3 INCHES DIAMETER WITH A DEPTH OF .076. REPAIRED FASTENER HOLES IN ACCORDANCE WITH SRM 57-20-90-R22.SDR SWAA084916Trunnion · corrodedDURING SCHEDULED MV2 CHECK, FOUND RT MLG FWD TRUNNION FITTING LUG CORRODED. REPAIRED FITTING PER SWA EA.SDR SWAA084915Trunnion · corrodedDURING SCHEDULED MV2 CHECK, FOUND LT MLG FWD TRUNNION FITTING LUG CORRODED. REPAIRED FITTING PER SWA EA.SDR 08FDEA03484Fitting · corrodedFOUND CORROSION ON LT MLG FWD PICK UP FITTING HOLE NR 8 AND NR 13. REPAIR PERFORMED BY BLEND OUT THE CORROSION, OVERSIZE THE HOLES IAW DRAWING R572-40266 AND INSTALLING BOLTS A228S32X IAW RAS/BAE/1006539/2008 ISS A , APPROVED BY EA 6-5751-1210094.SDR SWAA084559Fitting · crackedDURING SCHEDULED HC1 CHECK, FOUND LT MLG FWD WALKING BEAM FITTING CRACKED. R&R FITTING PER MM.SDR SWAA084530Fitting · corrodedDURING SCHEDULED MV2 CHECK, FOUND RT MLG TRUNNION FITTING CORRODED. REPAIRED FITTING PER SWA EA.SDR SWAA084529Fitting · corrodedDURING SCHEDULED MV2 CHECK, FOUND LT MLG TRUNNION FITTING CORRODED. REPAIRED FITTING PER SWA EA.SDR SWAA084352Fitting · corrodedDURING SCHEDULED MV2 CHECK, FOUND RT MLG FWD TRUNNION FITTING CORRODED. REPAIRED FITTING PER SWA EA.SDR SWAA084351Fitting · corrodedDURING SCHEDULED MV2 CHECK, FOUND LT MLG FWD TRUNNION FITTING CORRODED. REPAIRED FITTING PER SWA EA.SDR SWAA084006Trunnion · corrodedDURING SCHEDULED MV2 CHECK, FOUND LT MLG TRUNNION FITTING CORRODED. REPAIRED FITTING PER SWA EA.SDR SWAA084005Trunnion · corrodedDURING SCHEDULED MV2 CHECK, FOUND RT MLG TRUNNION FITTING CORRODED. REPAIRED FITTING PER SWA EA.SDR SWAA083908Trunnion · corrodedDURING SCHEDULED MV2 CHECK, FOUND RT MLG FWD TRUNNION FITTING CORRODED. REPAIRED FITTING PER SWA EA.
Back to JASC 5743