What was found
LT MLG TRUNNION FITTING CORRODED AT LOWER INBD HOLE OUTER FACE. AREA OF DISCREPANCY IS 2 INCHES BY 2 INCHES WITH A .084 INCH DEPTH. REMOVED CORROSION, TREATED, PRIMED, AND INSTALLED NEW BUSHING PER SRM 57-20-90-R2-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LT MLG TRUNNION FITTING CORRODED AT LOWER INBD HOLE OUTER FACE. AREA OF DISCREPANCY IS 2 INCHES BY 2 INCHES WITH A .084 INCH DEPTH. REMOVED CORROSION, TREATED, PRIMED, AND INSTALLED NEW BUSHING PER SRM 57-20-90-R2-2.