JASC 6300

Service difficulty reports · 637

Reports filed under 6300 · Main Rotor Drive System, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '6300'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR YV3R2022031000523None · defectiveCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: A051-1 BLOWS FUSE UPON TENSIONED.Feb 17, 2022 · N7073U · Robsin R22BETAIISDR YV3R2022031000522None · defectiveCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: C051-2 WAS INOPERATIVE.Feb 16, 2022 · Robsin R44RAVENIISDR YV3R2022030400520None · noneCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: C051-2 COLUMN SPRINGS DID NOT ACTUATE SIMULTANEOUSLY.Feb 16, 2022 · Robsin R44RAVENIISDR YV3R2022021600519None · noneCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: A051-1 PRODUCED AN INTERMITTENT CLUTCH LIGHT (FLICKERING).Feb 3, 2022 · Robsin R22BETAIISDR QMLA2022010420002Transmission · noneUPON START UP PILOT GOT MASTER WARNIG CAUTION "TRANSMISSION CHIP LIGHT" AND SHUT DOWN AC. I CAME TO BASE AND INSPECTED BOTH TRANSMISSION CHIP DETECTORS AND FOUND MULTIPLE CHIPS ON BOTH. AFTYER DRAINING SYSTEM AND ISPECTING FLUID FROM FILTER HOUSING, GEARBOX ANJan 1, 2022 · N803CF · Agusta A119SDR YV3R2021112900504None · defectiveCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: A051-1 RIGHT HAND COLUMN SPRING DOES NOT FUNCTION PROPERLY TO ACTUATE MICRO SWITCH.Nov 18, 2021 · N142VA · Robsin R22BETAIISDR YV3R2021112000503None · noneCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: C051-2 COLUMN SPRINGS FAILED TO ACTUATE MICRO SWITCH.Nov 10, 2021 · Robsin R44RAVENIISDR YV3R2021110900501None · noneCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: C051-1 COLUMN SWITCH FAILED.Nov 2, 2021 · N161WP · Robsin R22SDR YV3R2021110900498None · defectiveCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: A051-1 RESTRAINED (FAILED) IN THE EXTENDED STATE.Sep 22, 2021 · Robsin R22BETAIISDR YV3R2021090700494V-Belt · defectiveCUSTOMER REPORTED V-BELT SET P/N: A190-2 HAD A LUMP IN BELT CAUSING VIBRATION.Aug 24, 2021 · N991RW · Robsin R22BETAIISDR YV3R2021083100488Actuator · defectiveCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: A051-1 WAS INTERMITTENTLY FAILING DURING ENGAGEMENT.Aug 24, 2021 · Robsin R22BETAIISDR YV3R2021082800483Actuator · defectiveCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: C051-2 LOWER LIMIT SWITCH MALFUNCTIONED.Aug 24, 2021 · Robsin R44SDR YV3R2021083100487V-Belt · defectiveCUSTOMER REPORTED V-BELT SET P/N: A190-2 WERE STRETCHED BEYOND LIMITS. Aug 16, 2021 · Robsin R22BETAIISDR YV3R2021082800482V-Belt · stretchedCUSTOMER REPORTED V-BELT SET P/N: A190-2 ARE OVERSTRETCHED.Aug 16, 2021 · Robsin R22SDR YV3R2021082800481V-Belt · defectiveCUSTOMER REPORTED V-BELT SET P/N: A190-2 WERE STRETCHED BEYOND LIMITS.Aug 16, 2021 · Robsin R22SDR YV3R2021082800480Actuator · defectiveCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: C051-1 WILL NOT DISENGAGE DURING SWITCH SPRING TEST METHOD 1.Aug 13, 2021 · Robsin R44SDR YV3R2021072200474Actuator · defectiveCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: A051-1 BLOWS FUSES AND SLOW MOTOR.Jul 15, 2021 · Robsin R22BETAIISDR YV3R2021072200473Actuator · defectiveCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: A051-1 ACTIVATES LIGHT CONTINUOUSLY (FLICKERING).Jul 15, 2021 · Robsin R22BETAIISDR YV3R2021072200472Actuator · defectiveCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N:: A051-1 TRIPS 1.5 AMP FUSE.Jul 15, 2021 · Robsin R22BETAIISDR YV3R2021062200463Actuator · defectiveCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: C051-1 DID NOT COLLAPSE A COLUMN.Jun 8, 2021 · Robsin R44SDR YV3R2021062200462Actuator · defectiveCUSTOMER SENT IN ACTUATOR ASSEMBLY A051-1 FOR WARRANTY. COLUMN SPRINGS WERE FOUND TO BE NOT ENGAGING OR DISENGAGING SIMULTANEOUSLY WHEN BENCH TESTED.Jun 3, 2021 · Robsin R22SDR YV3R2021090100491Sheave · defectiveCUSTOMER SHEAVE, LOWER RECEIVED FOR WARRANTY. AFTER EVALUATION, BASE MATERIAL (ALUMINUM) WAS FOUND TO HAVE CORROSION, WHICH CAUSED BUBBLING BETWEEN ALUMINUM AND METALIZED COATING MATERIAL.May 27, 2021 · N14GG · Robsin R22SDR YV3R2021090100490Sheave · defectiveCUSTOMER SHEAVE, LOWER P/N: A493-1 RECEIVED FOR WARRANTY. AFTER EVALUATION, BASE MATERIAL (ALUMINUM) HAD CORROSION, WHICH CAUSED BUBBLING BETWEEN ALUMINUM AND METALIZED COATING MATERIAL.May 27, 2021 · N412TL · Robsin R22BETAIISDR YV3R2021090100489Sheave · defectiveCUSTOMER SHEAVE, LOWER P/N: A493-1 RECEIVED FOR WARRANTY. AFTER EVALUATION, BASE MATERIAL (ALUMINUM) HAD CORROSION, WHICH CAUSED BUBBLING BETWEEN ALUMINUM AND METALIZED COATING MATERIAL.May 27, 2021 · N969TA · Robsin R44SDR YV3R2021062200467Sheave · corrodedCUSTOMER RETURNED LOWER SHEAVE P/N:; A493-1. AFTER ENGINEERING EVALUATION, CORROSION WAS FOUND UNDER PLATING.May 27, 2021 · Robsin R22BETAIISDR YV3R2021062200466Sheave · corrodedCUSTOMER RETURNED LOWER SHEAVE P/N: A493-1. AFTER ENGINEERING EVALUATION, CORROSION WAS FOUND UNDER PLATING.May 27, 2021 · Robsin R22BETAIISDR YV3R2021062200465Sheave · corrodedCUSTOMER RETURNED LOWER SHEAVE P/N: A493-1. AFTER ENGINEERING EVALUATION, CORROSION WAS DISCOVERED UNDER PLATING.May 27, 2021 · Robsin R22SDR YV3R2021042700450V-Belt · defectiveCUSTOMER REPORTED V-BELT SET P/N: A190-2 WERE STRETCHED BEYOND LIMITS.Apr 15, 2021 · N508AD · Robsin R22BETASDR YV3R2021031300448V-Belt · defectiveCUSTOMER REPORTED V-BELT SET P/N: A190-3 OUTER SKIN OF BELT SEPARATED.Mar 5, 2021 · Robsin R44RAVENIISDR YV3R2021031300447Motor · defectiveCUSTOMER REPORTED GEARMOTOR ASSEMBLY P/N: D276-1 OPERATION TOO SLOW.Mar 5, 2021 · Robsin R44SDR YV3R2021031300446Actuator · defectiveCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: A051-1 WAS INTERMITTENT IN OPERATION.Mar 5, 2021 · N838SH · Robsin R22BETAIISDR YV3R2021031200444Motor · defectiveCUSTOMER REPORTED GEARMOTOR ASSEMBLY P/N: D276-3 WAS INTERMITTENT IN OPERATION.Mar 1, 2021 · Robsin R44SDR YV3R2021022200439V-Belt · splitCUSTOMER REPORTED V-BELT SET P/N: A190-3 BANDING MATERIAL SPLIT BETWEEN BELTS.Feb 20, 2021 · Robsin R44RAVENIISDR YV3R2021030300442V-Belt · defectiveCUSTOMER REPORTED V-BELT SET P/N: A190-2 WERE STRETCHED BEYOND LIMITS.Feb 18, 2021 · Robsin R22BETAIISDR YV3R2021030300441Actuator · defectiveCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: C051-2 WAS REMOVED DO TO BELT FAILURE.Feb 18, 2021 · Robsin R44RAVENIISDR YV3R2021020400432V-Belt · defectiveCUSTOMER REPORTED V-BELT SET P/N: A190-2 ARE STRETCHED BEYOND LIMITS.Feb 2, 2021 · Robsin R22SDR YV3R2021012000424V-Belt · defectiveCUSTOMER REPORTED V-BELT SET P/N: A1290-2 ARE STRETCHED BEYOND LIMIT.Jan 7, 2021 · Robsin R22BETAIISDR YV3R2021010700415Actuator · defectiveCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: A051-1 CAUSED CLUTCH LIGHT TO FLICKER.Jan 4, 2021 · N860VA · Robsin R22BETAIISDR YV3R2020121500405Motor · failedCUSTOMER REPORTED GEARMOTOR ASSEMBLY P/N: A051-2 BLOWS CIRCUIT PROTECTION FUSE.Dec 9, 2020 · N8038A · Robsin R22BETASDR YV3R2020121100403V-Belt · defectiveCUSTOMER REPORTED V-BELT SET P/N: A190-2 WAS DEFECTIVE. UPON INSPECTION V-BELT SET WERE FOUND TO BE STRETCHED BEYOND LIMITS.Dec 1, 2020 · N14HT · Robsin R22BETAIISDR YV3R2020120200399Actuator · defectiveCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: A051-1 DID NOT WORK.Nov 18, 2020 · Robsin R22SDR YV3R2020120200398Actuator · defectiveCUSTOMER REPORTED ACTUATOR ASSEMBLY A051-1 OPERATION WAS INTERMITTENT.Nov 13, 2020 · Robsin R22BETAIISDR YV3R2020111900391V-Belt · defectiveCUSTOMER REPORTED V-BELT SET P/N: A190-2 ARE STRETCHED BEYOND LIMITS.Nov 13, 2020 · Robsin R22BETAIISDR YV3R2020111900390V-Belt · defectiveCUSTOMER REPORTED V-BELT SET P/N: A190-2 WERE STRETCHED BEYOND LIMITS.Nov 13, 2020 · Robsin R22BETAIISDR YV3R2020111900389V-Belt · defectiveCUSTOMER REPORTED V-BELT SET P/N: A190-2 WERE STRETCHED BEYOND LIMITS.Nov 13, 2020 · Robsin R22BETAIISDR YV3R2020111400385Actuator · defectiveCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: A051-1 WILL NOT ENGAGE WHEN SELECTED WITH SWITCH.Nov 9, 2020 · N3092X · Robsin R22BETAIISDR YV3R2020111000381Actuator · failedCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: C051-1 SPRING SWITCH FAILED.Nov 5, 2020 · Robsin R44SDR M3XA20201013004Chip Detector · false activationPILOT PERFORMED A PL WITH A PATIENT ON BOARD AND REPORTED XMSN CHIP LIGHT ILLUMINATED DURING FLIGHT. PATIENT WAS TRANSPORTED BY GROUND. MECHANIC INSPECTED AL 3 CHIP DETECTORS OF THE ILO SYSTEM AND FOUND NO DEBRIS ON THE CHIP DETECTORS. PERFORMED 20 MINUTE GOct 13, 2020 · N911LG · Bell 407SDR YV3R2020122300408V-Belt · defectiveCUSTOMER REPORTED V-BELT SET P/N: A190-2 WERE STRETCHED BEYOND LIMITS.Oct 10, 2020 · N878MC · Robsin R22BETAIISDR YV3R2020102200368V-Belt · failedCUSTOMER REPORTED V-BELT P/N: A190-2 CORD WAS SEPARATING FROM BELT.Oct 8, 2020 · Robsin R22BETAII
Back to JASC 6300