JASC 6300

Service difficulty reports · 637

Reports filed under 6300 · Main Rotor Drive System, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '6300'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR YV3R2020101400362Actuator · defectiveCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: A051-1 CLUTCH LIGHT FLICKERING.Oct 8, 2020 · Robsin R22BETAIISDR YV3R2020101400361Actuator · defectiveCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: A051-1 CLUTCH LIGHT WOULD NOT EXTINGUISH RELATING TO RETENTION SCENARIO AT FLIGHT RPM.Oct 8, 2020 · Robsin R22BETAIISDR YV3R2020091700350V-Belt · defectiveCUSTOMER REPORTED V-BELT SET P/N: A190-2 WERE STRETCHED BEYOND LIMITS.Sep 10, 2020 · Robsin R22BETAIISDR YV3R2020091600340V-Belt · stretchedCUSTOMER REPORTED V-BELT SET P/N: A190-2 WAS STRETCHED BEYOND LIMITS. Aug 21, 2020 · Robsin R22BETAIISDR YV3R2020082800333V-Belt · defectiveCUSTOMER REPORTED V-BELT SET P/N: A190-2 BEDDING WAS SPLIT ON BELT A.Aug 21, 2020 · Robsin R22BETAIISDR YV3R2020082400331Actuator · defectiveCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: A051-1 WAS DEFECTIVE.Aug 19, 2020 · N878MC · Robsin R22BETAIISDR YV3R2020082000327Actuator · defectiveCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: A051-1 CONTINUES TO RETENTION UP TO 30 SECONDS.Aug 11, 2020 · N154SH · Robsin R22BETAIISDR YV3R2020081100317V-Belt · out of limitsCUSTOMER REPORTED V-BELT SET IS OVERSTRETCHED BEYOND MAXIMUM LIMIT.Jul 28, 2020 · Robsin R22BETAIISDR YV3R2020081100321V-Belt · out of limitsCUSTOMER REPORTED V-BELT SET P/N: A190-2 ARE OVERSTRETCHED. AND CRACKS IN OUTER LAMINATIONJul 28, 2020 · Robsin R22BETAIISDR YV3R2020081100325V-Belt · out of limitsCUSTOMER REPORTED V-BELT SET P/N: A190-2 ARE OVERSTRETCHED.Jul 28, 2020 · Robsin R22BETAIISDR YV3R2020081100324V-Belt · out of limitsCUSTOMER REPORTED V-BELT SET P/N: A190-2 ARE OVERSTRETCHED.Jul 28, 2020 · Robsin R22BETAIISDR YV3R2020081100323V-Belt · out of limitsCUSTOMER REPORTED V-BELT SET P/N: A190-2 HAD A BLEMISH ON BELT "B".Jul 28, 2020 · Robsin R22BETAIISDR YV3R2020081100322V-Belt · out of limitsCUSTOMER REPORTED V-BELT SET P/N: A190-2 ARE OVERSTRETCHED.Jul 28, 2020 · Robsin R22BETAIISDR YV3R2020081100320V-Belt · out of limitsCUSTOMER REPORTED V-BELT SET P/N: A190-2 ARE OVERSTRETCHED.Jul 28, 2020 · Robsin R22BETAIISDR YV3R2020081100319V-Belt · out of limitsCUSTOMER REPORTED V-BELT SET P/N: A190-2 WAS OVERSTRETCHED.Jul 28, 2020 · Robsin R22BETAIISDR YV3R2020081100318V-Belt · out of limitsCUSTOMER REPORTED V-BELT SET WAS OVERSTRETCHED BEYOND MAXIMUM LIMITS.Jul 28, 2020 · Robsin R22BETAIISDR YV3R2020081100316Actuator · inoperativeCUSTOMER REPORTED ACTUATOR ASSEMBLY SPRINGS FAIL TO ENGAGE SWITCHES.Jul 28, 2020 · Robsin R44RAVENIISDR YV3R2020081100315Actuator · inoperativeCUSTOMER REPORTED ACTUATOR ASSEMBLY WILL NOT ENGAGE.Jul 28, 2020 · Robsin R22BETAIISDR YV3R2020072400308Actuator · faultyCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: A051-1 WAS FAULTY (LIGHT ILLUMINATING MORE THAN 10 SECONDS).Jul 21, 2020 · Robsin R22BETAIISDR YV3R2020072400306V-Belt · defectiveCUSTOMER REPORTED V-BELT SET P/N: A190-2 WAS OVERSTRETCHED.Jul 21, 2020 · Robsin R22BETAIISDR YV3R2020072400305V-Belt · defectiveCUSTOMER REPORTED V-BELT SET P/N: A190-2 WAS OVERSTRETCHED.Jul 21, 2020 · Robsin R22BETAIISDR YV3R2020070700298Actuator · defectiveCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: C051-2 WAS DEFECTIVE.Jul 1, 2020 · N43926 · Robsin R44SDR YV3R2020062700291V-Belt · defectiveCUSTOMER REPORTED V-BELT SET P/N: A190-2 HAD A TIE-BAND DELAMINATION.Jun 18, 2020 · Robsin R22SDR YV3R2020070700295Actuator · defectiveCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: C051-2 RIGHT COLUMN SPRING DOES NOT OPERATE.Jun 15, 2020 · Robsin R44RAVENIISDR YV3R2020082800332V-Belt · failedCORRECTED, (SECTION 5, D): CUSTOMER REPORTED V-BELT SET P/N: A190-2 WAS MISSING OUTER SECTION ON BELT B.May 21, 2020 · Robsin R22BETAIISDR YV3R2020070700296Actuator · inoperativeCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: C051-2 RIGHT COLUMN SPRINGS FAILED TO OPERATE.May 11, 2020 · Robsin R44SDR YV3R2020062700286V-Belt · defectiveCUSTOMER REPORTED V-BELT SET P/N: A190-2 IS OVERSTRETCHED BEYOND LIMITS.May 11, 2020 · Robsin R22BETAIISDR YV3R2020062700285Belt · defectiveCUSTOMER REPORTED V-BELT SET P/N: A190-2 IS OVERSTRETCHED BEYOND LIMITS.May 11, 2020 · Robsin R22BETAIISDR YV3R2020062700284Actuator · defectiveCUSTOMER REPORTED CLUTCH ASSEMBLY P/N: C051-1 COLUMN SPRING SWITCHES FAILED TO ACTUATE SIMULTANEOUSLY.Apr 7, 2020 · Robsin R44SDR EVCA2020030600000Freewheel Unit · crackedDURING PERIODIC INSPECTION, THE FREEWHEELING UNIT HOUSING WAS VISUALLY DISCOVERED TO BE CRACKED ON THE MATING SURFACE TO THE ENGINE. THE CRACK EXTENDED APPROXIMATELY 0.5 INCHES FROM THE ATTACHMENT HOLE.Mar 6, 2020 · N499AE · Bell 407SDR QMLA2020020762007Transmission · making metal14934 HAD TRANSMSION CHIPS ON DETECTOR LOWER, PERFORMED OIL AND FILTER CHANGE. GROUND RUN AIRCRAFT AND NO CHIPS, FLEW AIRCAFT AND CHIP LIGHT ILLUMINATED, INSPECTED CHIP DETECTOR LOWER AND FOUND CHIPS, REPLACED OIL AND FILTER AGAIN AND GROUND RUN AIRCRAFT, THENFeb 6, 2020 · N359LL · Agusta AW119MKIISDR YV3R202002100239Belt · defectiveCUSTOMER REPORTED V-BELT SET P/N: A190-2 (1) BELT BROKE.Jan 28, 2020 · N7198N · Robsin R22BETAIISDR YV3R2020012820232V-Belt · defectiveCUSTOMER REPORTED V-BELT SET P/N: STRETCHED BEYOND LIMITS.Jan 10, 2020 · Robsin R22BETAIISDR YV3R2020012020230V-Belt · defectiveCUSTOMER REPORTED V-BELT SET P/N: A190-2 WAS CAUSING VIBRATION THROUGH HELICOPTER AT 100%.Jan 10, 2020 · Robsin R22BETAIISDR YV3R2020012720229Belt · defectiveCUSTOMER REPORTED V-BELT SET P/N: A190-2 STRETCHED BEYOND LIMITS.Jan 10, 2020 · Robsin R22BETAIISDR YV3R2020012020228V-Belt · faultyCUSTOMER REPORTED V-BELT SET P/N: A190-2 STRETCHED BEYOND LIMITS.Jan 10, 2020 · Robsin R22BETAIISDR YV3R2020012020227V-Belt · delaminatedCUSTOMER REPORTED V-BELT SET P/N: A190-2 FABRIC COVERING DELAMINATING.Jan 10, 2020 · Robsin R22BETAIISDR YV3R2020012020226V-Belt · faultyCUSTOMER REPORTED V-BELT SET P/N: A190-2 STRETCHED BEYOND LIMITS.Jan 10, 2020 · Robsin R22BETAIISDR YV3R2020012020222V-Belt · failedCUSTOMER REPORTED V-BELT SET P/N: A190-3 SNAPPED.Dec 14, 2019 · Robsin R44RAVENIISDR HEER201911071414Switch · inoperativeIN CRUISE FLIGHT AT 3000 FEET MGB BYPASS AND MGB PRESSURE LIGHTS ILLUMINATED. REPLACED MGB BYPASS TOGGLE SWITCH, REPAIRED WIRE TO MAIN TRANSMISSION LOW OIL PRESSURE SWITCH CANNON PLUG @ P417.Nov 1, 2019 · N937PH · Skrsky S92ASDR YV3R2019110120212Spring · malfunctionedCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: C051-2, ENGAGEMENT SPRING FAILURE.Oct 24, 2019 · Robsin R44RAVENIISDR YV3R2019102522210Belt · defectiveCUSTOMER REPORTED V-BELT SET P/N: A190-2 FLUTTERED (VIBRATION).Oct 24, 2019 · Robsin R22BETAIISDR YV3R2019102320206Spring · malfunctionedCUSTOMER REPORTED CLUTCH LIGHT IS STAYING ON FOR ACTUATOR ASSEMBLY P/N: A051-1 . BENCH TEST RESULTS; COLUMN SPRINGS ARE NOT ENGAGING SIMULTANEOUSLY.Oct 12, 2019 · Robsin R22BETAIISDR YV3R2019102320205Spring · malfunctionedCUSTOMER REPORTED CLUTCH LIGHT FOR ACTUATOR ASSEMBLY P/N: A051-1 WAS FLICKERING. BENCH TEST RESULTS; COLUMN SPRINGS NOT ENGAGING SIMULTANEOUSLY.Oct 12, 2019 · Robsin R22BETAIISDR YV3R2019102520208Actuator · malfunctionedCUSTOMER REPORTED FLICKERING CLUTCH LIGHT. BENCH TEST RESULTS, COLUMN SPRINGS NOT ENGAGING OR DISENGAGING SIMULTANEOUSLY.Oct 10, 2019 · Robsin R22BETAIISDR YV3R2019101220202Belt · defectiveCUSTOMER REPORTED V-BELT P/N: A190-2 HAD A BULGE INSIDE OF BELT.Oct 10, 2019 · Robsin R22BETAIISDR YV3R2019092400197Actuator · malfunctionedCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: A051-1 COLUMN SPRINGS ARE NOT ENGAGING SIMULTANEOUSLY, RESULTING IN FLICKERING CLUTCH LIGHT.Sep 20, 2019 · Robsin R22BETAIISDR YV3R2019091400185Actuator · defectiveCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: C051-1 COLUMN SPRINGS MECHANISM IS DEFECTIVE.Sep 9, 2019 · Robsin R44SDR YV3R2019091400184Actuator · defectiveCUSTOMER REPORTED ACTUATOR ASSEMBLY P/N: C051-2 COLUMN SPRINGS ARE NOT SNAPPING (RELEASE) ON ENGAGEMENT.Sep 9, 2019 · Robsin R44SDR YV3R2019090700180V-Belt · stretchedCUSTOMER REPORTED V-BELT SET P/N: A190-2 STRETCHED TO MAXIMUM WEAR WITH WAVES IN GROOVES BY SEAM.Sep 4, 2019 · N7198N · Robsin R22BETAII
Back to JASC 6300