What it covers
The unit which injects metered fuel into piston engine cylinders and burner cans in turbine engines.
Service difficulty reports · 529
Reports filed under 7313, newest first.
| 1995 | 36 |
|---|---|
| 1996 | 44 |
| 1997 | 27 |
| 1998 | 41 |
| 1999 | 17 |
| 2000 | 32 |
| 2001 | 17 |
| 2002 | 21 |
| 2003 | 34 |
| 2004 | 22 |
| 2005 | 12 |
| 2006 | 7 |
| 2007 | 14 |
| 2008 | 8 |
| 2009 | 17 |
| 2010 | 15 |
| 2011 | 15 |
| 2012 | 21 |
| 2013 | 13 |
| 2014 | 14 |
| 2015 | 19 |
| 2016 | 15 |
| 2017 | 8 |
| 2018 | 15 |
| 2019 | 6 |
| 2020 | 7 |
| 2021 | 6 |
| 2022 | 5 |
| 2023 | 6 |
| 2024 | 7 |
| 2025 | 4 |
| 2026 | 4 |
SDR 2026FA0000644Fuel Nozzle · mismanufacturedWE WERE NOTIFIED THROUGH SAE THAT ONE OF OUR DELIVERED ENGINES ESN 59B359 BELONGING TO AIR INDIA, WHICH IS PART OF THEIR OFFLOAD PROGRAM, HAD ONE FUEL NOZZLE THAT HAD AN ISSUE WITH THE ASSY PROCESS (SHIM NOT INSTALLED) BY THE SUPPLIER OF FUEL NOZZLES. THIS WASSDR 2026FA0000639Shim · missingREFERENCE SAE RETEX – EQ6349 DURING A REVIEW OF THE ASSEMBLY PROCESS PERFORMED BY FUEL NOZZLE SUPPLIER, HAS FOUND NOZZLES THAT REQUIRE ATTENTION DUE TO AN ERROR IN THE VALVE ASSEMBLY PROCESS CONFIRMED THROUGH AN EVALUATION OF X-RAY IMAGES. S/N CONCERNED: PAT0SDR SWAA2026040184672Pump · faultedRIGHT SIDE FUEL FILTER BYPASS LIGHT ILLUMINATED DURING CLIMBOUT AND AFTER LEVEL OFF. LIGHT ILLUMINATED AND EXTINGUISHED MULTIPLE TIMES. REMOVED AND REPLACED NR 2 FUEL PUMP PACKAGE IAW MM 73-11-01, REF TTG8Q01BDU5. PERFORMED TEST 15 IAW MM 71-00-00. OPS & L
See all 529 reports