SDR TRBA201201801Switch · inoperativeTHE CREW REPORTED BOTH TAXI LIGHT INOPERATIVE BUT LANDING LIGHTS WORK PROPERLY. THE ACFT WAS REMOVED FROM SERVICE. R & R SWITCH 1LR IAW MM 20-45-10, OPS CHECK FOUND OK IAW JIC 33-46-00. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA2012017002Cap · missingDURING MX BASE INSPECTION, FOUND THE EMERGENCY LIGHT END CAP MISSING AT THE GALLEY AREA. THE ACFT WAS REMOVED FROM SERVICE. INSTALLED EMERGENCY LIGHT END CAP IAW JIC 25-13-10, RAI 10000-002. THE OPS CHECK WAS GOOD. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA2012017001Switch · corrodedDURING MX BASE INSPECTION, FOUND THE LT MLG WEIGHT ON WHEEL SWITCH 50GB PINS ARE SEVERELY CORRODED. THE ACFT WAS REMOVED FROM SERVICE. R & R LT MLG PROXIMITY SWITCH 50GB IAW JIC 32-61-00. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA2012012004Cover · brokenTHE CREW REPORTED THE EMERGENCY LIGHT COVER NEXT TO THE GALLEY IS BROKEN. THE ACFT WAS REMOVED FROM SERVICE. R & R THE LIGHT COVER AT GALLEY AREA IAW MM 33-51-24. THE ACFT WAS RETURNED TO SERVICE.SDR COEA2012011107819Floorbeam · bentHEAVY CK / MAJOR REPAIR: LEFT O/B LONGITUDINAL FLOORBEAM IS BENT JUST FWD OF FRAME 23C. REMOVED DAMAGED SECTION / FABRICATED AND INSTALLED NEW FLOORBEAM AND CLIPS IAW M7 SB ATR72-53-015.SDR COEA2012011106819Floorbeam · bentHEAVY CK / MAJOR REPAIR: RIGHT O/B LONGITUDINAL FLOORBEAM IS BENT JUST AFT OF FRAME 23C. REMOVED DAMAGED SECTION / FABRICATED AND INSTALLED NEW FLOORBEAM AND CLIPS IAW M7 SB ATAR72-53-015.SDR COEA2012011105819Floorbeam · crackedHEAVY CK / MAJOR REPAIR: LEFT O/B LONGITUDINAL FLOORBEAM IS CRACKED JUST FWD OF FRAME 25. REMOVED DAMAGED SECTION / FABRICATED AND INSTALLED NEW FLOORBEAM AND CLIPS IAW M7 SB ATR72-53-015.SDR COEA2012011104819Floorbeam · crackedHEAVY CK / MAJOR REPAIR: LT OUTBOARD LONGITUDINAL FLOORBEAM IS CRACKED JUST FWD OF FRAME 26. REMOVED DAMAGED SECTION / FABRICATED AND INSTALLED NEW FLOORBEAM AND CLIPS IAW M7 SB ATR72-53-015.SDR COEA2012011103819Floorbeam · crackedHEAVY CK / MAJOR REPAIR: RIGHT O/B LONGITUDINAL FLOORBEAM IS CRACKED JUST AFT OF FRAME 28C. REMOVED DAMAGED SECTION / FABRICATED AND INSTALLED NEW FLOORBEAM AND CLIPS IAW M7 SB ATR72-53-015.SDR COEA2012011112801Skin Panel · damagedNR 2: DAMAGE REPAIR COE: MAJOR REPAIR: IMPACT DAMAGE FROM GROUND SUPPORT STAND AND EXTREMELY WINDY CONDITIONS ON OUTER SKIN COMMON TO FR 8, STRINGER 11, DAMAGE TO PANELS LATERAL SKIN S53171501206 & LT LOWER SKIN S53172201210 & FRAME (8) S53171509201. SUBMITSDR COEA2012011111801Stringer Clip · damagedHEAVY CK COE / MAJOR REPAIR: REMOVED STRUCTURE TO FOM FOR FRAME 37. FABRICATED AND INSTALLED STRINGER CLIP FRAME 37 AND STRINGER 15R IAW ATR72 SRM. RE-INSTALLED UPPER AND LOWER INTERCOSTAL AT FR 37 STR 9 AND LOWER INTERCOSTAL AT FR 37 STR 11 AND LOWER INTERCSDR TRBA2012012006Skin · corrodedDURING MX BASE INSPECTION FOUND CORROSION ON THE RT WING FUEL PUMP CUTOUT EXTERNAL SURROUNDS. THE ACFT WAS REMOVED FROM SERVICE. BLENDED OUT CORROSION AND FOUND REMAINING THICKNESS OUT OF LIMITS IAW SRM 51-21-58, ALSO SUBMITTED AN ONLINE DAMAGE REPORT IAW ETSDR COEA2012010902819Floorbeam · crackedHEAVY CK / MAJOR REPAIR: RT OUTBOARD LONGITUDINAL FLOORBEAM IS CRACKED JUST FWD FOR FRAME 31. FABRICATED, DRILLED AND INSTALLED NEW LONGITUDINAL FLOORBEAM AND 8 EACH ATTACH CLIPS IAW M7 SB72-53-015.SDR COEA2012010901819Floorbeam · crackedHEAVY CK / MAJOR REPAIR: LT OUTBOARD LONGITUDINAL FLOORBEAM IS CRACKED JUST FWD OF FRAME 33. FABRICATED AND DRILLED AND INSTALLED NEW LONGITUDINAL FLOORBEAM AND 8 EA ATTACH CLIPS IAW M7 SB ATR72-53-015.SDR TRBA2012012003Cover · brokenON FLIGHT 4809, CREW REPORTED THE LOWER SERVICE DOOR EMERGENCY EXIT SIGN COVER IS BROKEN AND THE PANEL AROUND IS BROKEN AS WELL. THE ACFT WAS REMOVED FROM SERVICE. R & R THE SERVICE DOOR EMERGENCY EXIT SIGN COVER IAW JIC 33-50-00. OPS CHECKED GOOD. THE ACFT SDR TRBA2012010003Light · inoperativeDURING MX INSPECTION FOUND THE EMREGENCY LIGHT AT PASSENGER AND CREW DOOR INOPERABLE. THE ACFT WAS REMOVED FROM SERVICE. RESECURED EMERGENCY LIGHT ON PASSENGER AND CREW DOOR IAW JIC 33-51-24, RAI 10000 002. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA2012010002Light · damagedEMERGENCY FLOOR LIGHT COMING APART AROUND ROWS 15 AND 16. THE ACFT WAS REMOVED FROM SERVICE. RESECURED EMERGENCY LIGHT STRIP AT ROWS 15 AND 16 IAW JIC 33-50-00. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA2012024001Light · malfunctionedTHE CREW REPORTED THAT AFTER START OR SHUTDOWN THE EMERGENCY LIGHTS STAYED ON, AND HAD TO BE RESET. THE ACFT WAS REMOVED FROM SERVICE. ACCOMPLISHED TEST IAW JIC 33-50, OPERATES OK, RAN ENGINE LIGHT, RESET CORRECTLY. NO PARTS REMOVED OR REPLACED. THE AIRCRAFTSDR TRBA2012013002Light · out of positionCABIN DOOR EMERGENCY STEP LIGHTS INOPERATIVE. ACFT REMOVED FROM SERVICE. REPOSITIONED THE CABIN DOOR EMERGENCY STEP LIGHTS. OPERATED AND IS WORKING PROPERLY IAW MM 33-51-24. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA201200902Fuse · inoperativeCREW REPORTED AN ELECTRICAL SMOKE ODOR, REPORTED AT CARGO 4. ACFT WAS REMOVED FROM SERVICE. CHECKED CABIN ENTRANCE LIGHT AND SERVICE DOOR LIGHT SOCKETS AND FOUND BROKEN. R & R FUSE, OPS CHECKED GOOD. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA2012010005Bulb · inoperativeTHE CREW REPORTED THE EMERGENCY LIGHTS INOPERABLE AT CABIN ENTRANCE AND SERVICES DOORS. THE ACFT WAS REMOVED FROM SERVICE. REPLACED EMERGENCY LIGHT BULBS AT CABIN & SERVICES DOOR ENTRANCE IAW JIC 33-51-20, THE OPS CHECK WAS GOOD. THE ACFT WAS RETURNED TO SERSDR TRBA201200901Windshield · crackedAFTER TAKEOFF, THE CREW REPORTED THE WINSCREEN CRACKED. THE CREW ELECTED TO RETURN TO DEPARTURE. THE ACFT WAS REMOVED FROM SERVICE. R & R CAPTAIN'S WINDSHIELD IAW JIC 56-11-00, RAI 10000. THE OPS CHECK AND LEAK CHECK OK. THE ACFT WAS RETURND TO SERVICE.SDR COEA2012010510801Splice · crackedHEAVY CK COE / MAJOR REPAIR: AFT OF FRAME 27, LEFT SIDE NEAR STRINGER 4 PRESSURE DECK SPLICE ANGLE IS CRACKED. REPAIRED PER SRAS DT/S-295/11...6827.SDR COEA2012010509801Splice · crackedHEAVY CK COE / MAJOR REPAIR: AFT SIDE OF FRAME 27, RIGHT SIDE NEAR STRINGER 4 PRESSURE DECK SPLICE ANGLE HAS CRACK. REPAIRED PER SRAS DT/S-295/11.SDR TRBA201200603Flap · brokenTHE CREW ABORTED TAKEOFF FOR STRONG SURGE. ENGINE PERAMETERS WERE OK . NORMAL FOR TAKEOFF. FELT LIKE A BLOWN TIRE OR STUCK BRAKES. ACFT DID NOT PULL IN EITHER DIRECTION. ACFT REMOVED FROM SERVICE. FOUND LT ENGINE OIL COOLER 1 FLAP STUCK AND THE OTHER FLAPSDR COEA2012010408801Frame · corrodedHEAVY CK COE / MAJOR REPAIR / LEVEL 2 CORROSION: FRAME 36 AT STRINGER 14R CORRODED, STRINGER CLIP AT STR 18 REQUIRES REPLACEMENT DUE TO INTERFERENCE WITH FRAME SPLICE (LENGTH 6", WIDTH 2", DEPTH .050"). REMOVED CORROSION, REPLACED FRAME SEGEMENT WITH OEM PARSDR COEA2012010407801Crease Beam · corrodedRIGHT CREASE BEAM WEB FR 34-15 HAS TOOLING MARKS AND CORROSION ON UPPER SURFACE (LENGTH 3', WIDTH 2", DEPTH .020"). REMOVED CORROSION, FABRICATED AND INSTALLED NEW SHEAR WEB IAW SRM.SDR COEA2012010406801Crease Beam · corrodedHEAVY CK COE / MAJOR REPAIR / LEVEL 2 CORROSION: MATING SURFACE OF RT CREASE BEAM WEB AT FR 20-21 HAS LEVEL 2 CORROSION (LENGTH 2.75", WIDTH 3.5", DEPTH .012"). REMOVED CORROSION FABRICATED AND INSTALLED NEW WEB IAW ATR72 SRM.SDR COEA2012010405801Floor Support · corrodedHEAVY CK COE / LEVEL 2 CORROSION: SERVICE DOOR INBOARD SUPPORT INTERCOSTAL FR 38-39 IS CORRODED AROUND THE FLOORBOARD NUT PLATES (LENGTH 3.75", WIDTH 2.5", DEPTH .01). REMOVED CORROSION, INSTALLED NEW OEM FLOOR SUPPORT CHANNEL IAW ATR72 SRM.SDR TRBA2012013004Lamp · inoperativeTHE CREW REPORTED THE EMERGENCY LIGHT NOT WORKING FORWARD LT SIDE "PLUG DOOR". THE ACFT WAS REMOVED FROM SERVICE. R & R BULB IAW AMM 33-50-00. THE OPS CHECK WAS GOOD. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA201200602Bulb · inoperativeTHE CREW REPORTED EMERGENCY LIGHT NOT WORKING FWD LT SIDE "PLUG DOOR". THE ACFT WAS REMOVED FROM SERVICE. R & R BULB. THE OPS CHECK WAS GOOD IAW AMM 33-50-00. ALSO THE NR1 INVERTER FAULT LIGHT CAME ON. R & R NR 1 INVERTER IAW JIC 24-21-81 SYS CHECK GOOD.SDR TRBA201200601Battery · faultedTHE CREW REPORTED THE EMERGENCY BATTERY CHARGE FAULT CAME ON DURING TAXI OUT. THE ACFT WAS REMOVED FROM SERVICE. R & R THE EMERGENCY BATTERY IAW EX-243185-RAI-10020-002. ALSO, R & R THE EMERGENCY BATTERY CONTACTOR 42PA. THE OPS CHECK WAS GOOD IAW JIC 24-00SDR COEA2012010304801Skin · dentedHEAVY CK COE / MAJOR REPAIR: DENT IN FUSELAGE SKIN BETWEEN FR 29-30 AND STR 18L - 19L. DRILL OUT AND FILL WITH RIVET 9 IN AFT OF FR 29 AND 4.75 IN I/B OF STR 18L IAW ATR72 SRM.SDR COEA2012010303801Crease Beam · corrodedHEAVY CK COE / MAJOR REPAIR / LEVEL 2 CORROSION: CORROSION ON MATING SURFACE OF RT CREASE BEAM WEB AT FR 22-23 (LENGTH 3.5", WIDTH 2.25", DEPTH .024"). REMOVED CORROSION, FABRICATED AND INSTALLED NEW WEB IAW ATR72 SRM.SDR COEA2012010302801Frame · corrodedHEAVY CK COE / LEVEL 2 CORROSION: FRAME 44 HAS CORROSION ON AFT SIDE BL 0, BOTH SIDES OF THE FLOORBOARD FLANGE AND THE UPPER FLANGE OUTBOARD OF LT & RT OUTBOARD SEAT TRACKS (LENGTH 5", WIDTH 2", DEPTH .05"). REMOVED CORROSION AND REPLACED FRAME WITH OEM PART.SDR COEA2012010301801Floorbeam · gougedHEAVY CK COE / MAJOR REPAIR: GOUGES ON LOWER SIDE OF UPPER FLANGE AND ALONG VERTICAL WEB (AFT SIDE ONLY) OF FLOORBEAM AT FRAME 26. BLEND AND SUBMIT TO ATR. REPAIR SRAS DT/S-817/11...6828 AND SRI FROM ATR.SDR TRBA2012012001Battery · dischargedDURING MX BASE VISIT FOUND THE EMERGENCY BATTERY LOW VOLTAGE. THE ACFT WAS REMOVED FROM SERVICE. R & R THE EMERGENCY BATTERY IAW JIC 24-31-85.. THE ACFT WAS RETURNED TO SERVICE.SDR COEA2011122755801Crease Beam · corrodedHEAVY CK COE / LEVEL 2 CORROSION: RT CREASE BEAM INNER CHORD BETWEEN FRAMES 7-14 HAS CORROSION (LENGTH 4", WIDTH 3", DEPTH .014"). REMOVE CORROSION, REPLACE RT CREASE BEAM INNER CHORD WITH OEM PART IAW ATR72 SRM.SDR COEA2011122754801Crease Beam · corrodedHEAVY CK COE / MAJOR REPAIR / LEVEL 2 CORROSION: LT CREASE BEAM INNER CHORD HAS CORROSION AFT OF FRAME 22 (LENGTH 3.5", WIDTH 1.", DEPTH .019"). REMOVED CORROSION, FABRICATED AND INSTALLED NE INNER CHORD AND SPLICE REPAIR IAW ATR72 SRM.SDR TRBA201136305Fan · failedNR 1 RECIRCULATING FAN FAULT. STRONG BURNING ODOR COMING FROM DUCT ASSOCIATED WITH SOME SMOKE. NR 1 RECIRCULATING FAN REPLACED IAW MM 21-22-21. SYS. OPERATED AND ITS WORKING PROPERLY.SDR TRBA201136303Flashlight · missingCABIN FLASHLIGHT MISSING. REPLACED MISSING FWD CABIN FLASHLIGHT IAW JIC 25-00.SDR TRBA201136101Engine · shutdownTHE NR 1 ENGINE FAILED DURING INITIAL CLIMB AT 5000 FT. NO UNUSUAL NOISES OR SURGES OR FIRE INDICATIONS DURING FAILURE. SECURED ENGINE IAW EPC AOM VOL 1 . DECIDED TO RE-START IAW AOM. ENGINE STARTED NORMALLY. LANDED WITH BOTH ENGINES OPERATIONAL. ENGINE SHSDR COEA2011122353801Skin Panel · corrodedHEAVY CK COE / MAJOR REPAIR / LEVEL 2 CORROSION: UPPER EXTERNAL SKIN UNDER ADF ANTENNA HAS CORROSION (LENGTH, 9.0", WIDTH 18.0", DEPTH .012"). FOUND CORROSION AND DEEP GOUGES ON EXTERNAL SKIN UNDER ADF ANTENNA, BLENDED DAMAGE AND REMOVED CORROSION FROM EXTERNSDR COEA2011122352801Stringer · crackedHEAVY CK COE / MAJOR REPAIR: RT STR 2A HAS SPOT OF LEVEL 1 CORROSION FROM FRAME 14 - FRAME 16. WHILE REMOVING CORROSION FOUND RT STR 2A CRACKED. REMOVED STRINGER, FABRICATED AND INSTALLED STRINGER REPAIR SPLICE AND STRINGER IAW ATR72 SRM AT STR 2A BETWEEN FSDR COEA2011122351801Crease Beam · corrodedHEAVY CK COE / LEVEL 2 CORROSION: LT CREASE BEAM INNER CHORD IS CORRODED FR 39-40 (LENGTH 1.", WIDTH 1", DEPTH .011"). REMOVED CORROSION AND INSTALLED NEW FLOOR SUPPORT ZEE WITH OEM PART IAW ATR72 SRM.SDR COEA2011122350801Crease Beam · corrodedHEAVY CK COE / LEVEL 2 CORROSION: LT CREASE BEAM WEB CORRODED AT FRAME 39-40 TOP AND BOTTOM SURFACE (LENGTH 2.75", WIDTH 4.0", DEPTH .011"). REMOVED CORROSION, INSTALLED TWO ANGLES AND TWO DOUBLERS, NEW CREASE BEAM WEB IAW ATR72 SRM WITH OEM PART.SDR COEA2011122249801Structure · corrodedHEAVY CK COE / LEVEL 2 CORROSION: RT FWD INNER CHORD BETWEEN FR 16-18 HAS 2 EA SPOTS OF CORROSION (LENGTH 2", WIDTH 2", DEPTH .015"). REMOVED CORROSION AND INSTALLED NEW RT INNER CHORD FROM FRAME 13 TO FRAME 23 IAW ATR72 SRM.SDR COEA2011122248801Crease Beam · corrodedHEAVY CK COE / LEVEL 2 CORROSION: RT CREASE BEAM WEB 28D - 29 IS CORRODED ON THE UPPER AND LOWER SURFACES (LENGTH 2", WIDTH 3"). REMOVED CORROSION, INSTALLED NEW RT CREASE BEAM WEB FR 28D - 29 IAW ATR72 SRM.SDR TRBA201136301Structure · corrodedLT WING FUEL PUMP CUT OUT AREA CORRODED. COMPLIED WITH EO E2-5700-476.SDR COEA2011122147801Plate · corrodedHEAVY CK COE / MAJOR REPAIR / LEVEL 2 CORROSION: FORWARD CARGO DOOR DRAIN CHANNEL MOUNT PLATE HAS CORROSION (LENGTH 6", WIDTH 1", DEPTH .010"). REMOVED CORROSION, FABRICATED AND INSTALLED SUPPORT PLATE IAW ATR72 SRM.
Back to Aerospatiale ATR 72-212