Aerospatiale ATR 72-212
Service difficulty reports · 4,441
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'ATR72212' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'ATR72212' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR TRBA2010106Power Supply · inoperativeFWD EMERGENCY LIGHTS STAY ON THIS TIME. REPLACED EMERGENCY LIGHTS POWER SUPPLY FIN NR 43WL IAW JIC 33-51-21. PERFORMED OPS CHECK AND FOUND SYS WORKING PROPERLY.SDR TRBA2010105SUPControl Lever · inoperativeAFTER TAKEOFF LANDING GEAR DID NOT RETRACT COMPLETLY AND CONTINUED TO EXTEND AND RETRACT CONSTANTLY. R & R PROXIMITY SENSORS 52EB AND 53 GB AT NLG IAW JIC 32-61-00 AND R & R CONTROL LEVEL IAW JIC 32-31-81. PERFORMED RETRACTION TEST FOUND OK 32-31-00.SDR TRBA2010105Landing Gear · malfunctionedAFTER TAKEOFF, LANDING GEAR DID NOT RETRACT COMPLETELY, "EMERGENCY DECLARED". OPENSDR TRBA2010104Socket · burnedAFTER TAKEOFF STRONG ELECTRIC ODOR IN COCKPIT POSSIBLY UNDER PANEL BEHIND F/O SEAT, F/A'S CABIN HAS NO SMELL. IAW JIC 33-21-23, REPLACED FLORESCENT TUBS SOCKET LIGHT ASSY FIN 286LGA. OPS CHECK OK AWM USED 61-22-01 FOR WIRE CONNECTION.SDR TRBACPCP2010051Skin · corrodedLT WING, LOWER SKIN, REAR SPAR AT RIBS 7/8 CORROSION TITANIUM DOUBLER PERMANENT REPAIR. ACCOMPLISHED SRI DO/TS 3217-10-13551 REF ART FORM PL-004-1 FOR DOUBLER FAB, COMPLIED WITH EO E2-57MR-404, REF NDT REPORT AMS 100810-19 FOR HFEC ROTO AND UT VALUES NO DEFESDR TRBACPCP2010049Bulkhead · corrodedDURING THE SCHEDULED HEAVY CHECK INSP, CORROSION WAS FOUND ON THE FWD PRESSURE BULKHEAD WEB IN 8 AREAS. COMPLIED WITH SRI DO/TS-4275/10-13979 REF NDT REPORT AMS 100810-15 FOR HFEC AND U.T. VALUES NO DEFECTS NOTED. ACCOMPLISHED EO E2-57MR-259. COMPLIED WITH SSDR TRBA2010103Engine · odorAFTER PARKING THE ACFT AND SHUTTING DOWN THE NR 1 ENGINE A VERY STRONG PLASTIC BURNING ODOR ENTERED THE COCKPIT AND CABIN. INSPECTED CABIN & COCKPIT FOR PLASTIC ODOR, RUN ENGINE NR 1 FOR 30 MIN NO DISCREPANCIES NOTED IAW JIC 72-00-00, ERU 10040.SDR TRBACPCP2010044Skin · corrodedLT WING, LOWER SKIN, REAR SPAR AT RIBS 7/8 CORROSION TITANIUM DOUBLER PERMANENT REPAIR. WAITING FOR COMPLETION OF E0 E2-57MR-404 FOR FURTHER DETAILS.SDR TRBA2010101Switch · malfunctionedTHE EMERGENCY EXIT LIGHT ABOVE THE NR 1 AND NR 2 F/A AND BY THE COCKPIT JUMPSEAT IS ILLUMINATED AT ALL TIME WITH EMERGENCY EXIT LIGHT OFF. REPLACED 2 MINUTES LIGHT SWITCH 9LE. FOUND SYS WORKING OK.SDR TRBA2010100Bolt · missingFLOOR EMERGENCY PROXIMITY LIGHT AT GALLEY IS MISSING SECURING BOLTS. INSTALLED MISSING HARDWARE.SDR TRBA2010099Valve · malfunctionedEXCESSIVE FUEL BURN OUT OF RT FUEL TANK - NO FUEL BURN OUT OF LT TANK. "EMERGENCY DECLARED". R & R CROSSFEED FUEL VALVE AND ACTUATOR IAW 28-23-72. RAI 10000 AND 28-23-71 RAI 10000. OPS TEST GOOD.SDR TRBA2010098Lamp · inoperativeFLOOR PATH EMERGENCY LIGHT INOP ROW 10. RELAMPED ROW 10 FLOOR PROXIMITY LIGHT IAW SRM 20-43-13, MEL RESTORED.SDR TRBA2010097Lamp · inoperativeEMERGENCY LIGHT MAIN CABIN DOOR INOP C/A RELAMPED AND CHECK IAW W/C EX 335000-10000-006.SDR 2010F00191Stringer · crackedSTRINGER 1R AT FRAME 20 CRACKED DRAIN HOLESDR 2010F00190Stringer · crackedSTRINGER 1L AT FRAME 20 CRACKED AT DRAIN HOLE.SDR TRBA2010096Eec · faultedDURING CRUISE FLIGHT, CLEAR ATMOSPHERIC CONDITIONS NR 1 ENGINE FLAMEOUT, RESTART WAS SUCCESSFUL (DECLARED EMERGENCY) REMOVED AND INSTALLED NR1 ENG EEC IAW ATR JIC 73-23-61, RAI 10000-026 ALSO REMOVED AND INSTALLED NR 1 T2 SENSOR & NR 2 T2 SENSOR IAW MM 72-01-6SDR TRBACPCP2010042ASkin · corrodedAN AREA OF CORROSION WAS FOUND PREVIOUSLY AT LT WING LOWER SKIN T/E AT RIB 13 AND A TEMPORARY REPAIRED ON EO E2-57MR-347R1. NOW DURING C-CHECK FINAL REPAIR IS ACCOMPLISHED BY FOLLOWING REPAIR INSTRUCTIONS (SRI) ISSUED BY ATR AND A SRAS TO APPROVE IT. C/A: WAITSDR TRBA2010095Light · inoperativeEMERGENCY PATH LIGHTS GALLEY AERA "FIRST" ON FLOOR OUT OF POSITION. R & R GALLEY AERA PATH LIGHT. OPS OK IAW CMM 33-52-10.SDR TRBACPCP2010052Floorbeam · corrodedLT FLOORBOARD BEAM AT FR 33 HAS CORROSION REFER TO CRIC CARD 006676. REMOVED CORROSION ON LT FLOORBEAM AT FR 33 FOUND TO BE OUT OF LIMITS IAW SRM 53-00-00 FABRICATED REPAIR IAW SRM 53-00-00 SEE ART FORM PL-004-1R1 FOR REPAIR PARTS FABRICATION DETAILS. INSTALLESDR TRBA2010092Cover · brokenEMERGENCY FLOOR LIGHT IN FRONT OF GALLEY CART ARE BROKEN OR LOOSE. R & R PLASTIC COVER OF EMERGENCY LIGHT ON GALLEY AREA IAW MM 33-51-21.SDR 2010F00184Spar · corrodedRT HORIZONTAL STAB REAR SPAR WEB HAS AN AREA OF CORROSION BELOW PANEL 342 EZ BEYOND SRM LIMITS. REMOVED CORROSION IAW SRM 51-21-42, REV 77. MEASURED AFFECTED AREA MIN MATERIAL REMAINING .037" REF NTM 51-40-00 REV 34. CONFIRMED CRACK FREE CONDITION REF NTM 51-SDR TRBA2010090Power Supply · inoperativeSEVERAL LIGHTS OUT ON FLOOR PATH EMERGENCY LIGHTING. R & R EMERGENCY LIGHT POWER SUPPLY AND BATTERY IAW MM JIC 33-51-21-RAI-10000. OPS CHECK OK IAW 33-50-00-OPT-10000 (61WL).SDR TRBA2010089Light · damagedFLOOR PATH EMERGENCY LIGHT STRIP BY ROWS 10&11 MISSING COVER AND DAMAGED. R & R FLOOR PATH LIGHT STRIP. OPS CHECK OK IAW MM JIC 33-50-00-OPT-10000.SDR TRBA2010088Light · inoperative2 EMERGENCY EXIT PATH LIGHTS INOP IN FRONT OF GALLEY. REPLACED ASSY 2 EMERGENCY EXIT PATH LIGHTS IAW JIC 33-51-21.SDR TRBA2010087Battery Pack · inoperativeEMERGENCY LIGHTS ILLUMINATED IN FLIGHT. R & R THE POWER SUPPLY AND BATTERIES AT LOCATION 73WL AND OPS CHECK OK IAW AMM JIC 33-51-21-RAI-10000, 33-51-21-RAI-10010, 33-50-00-OPT-10000 AND WORK CARD EX-335000-OPT-10000.SDR TRBA2010085Socket · burnedELECTRICAL BURNING SMELL NOTICED BY F/A AND GROUND CREW WHEN A/C PARKED ON GROUND MORE MID CABIN TO GALLEY. FOUND AFT LIGHT SOCKET ABOVE 17-AB BURNED ITEM DEFERRED IAW MEL NR 33-2 AUTH, NR 070229-C. CAT "C" WAITING FOR COMPLETION OF MEL FOR FURTHER DETAILS. SDR 2010F00178Floorbeam · corrodedFLIGHT DECK, FLOORBEAM 11 ABOVE STRINGER 20L HAS SURFACE CORROSION ON UPPER SURFACE AND ON INTERCOSTAL JUST AFT OF BEAM CORROSION BEYOND SRM LIMITS. (LEVEL II) REMOVED CORROSION IAW ATR 72 SRM 51-21-42 REV 77. VERIFY CORROSION REMOVAL ON FLOORBEAM 11. PRIMESDR 2010F00177Crease Beam · corrodedRT CREASE BEAM WEB AFT OF FRAME 39 HAS AREAS OF CORROSION BEYOND SRM LIMITS. (LEVEL II) REMOVED CORROSION IAW ATR 72 SRM 51-21-42 REV 77. FOUND MATERIAL LOSS TO BE BEYOND SRM LIMITS IAW ATR 72 SRM 53-61-00 FIG 301 AND 53-67-70 FIGURE 109 ITEM 30 REV 77. REMSDR TRBA2010083Wire · brokenEMERGENCY LIGHT PATH LIGHTS BROKEN WIRES SEAT 12B. REPAIRED WIRE AT SEAT 12B FLOOR PATH LIGHT IAW SPM 20-27-17. OPT CHECK GOOD IAW JIC. 33-50-00.SDR TRBA2010082Unknown · multiple failDURING FLIGHT LIGHTNING STRIKE, F/O LOOSE COMMUNICATIONS. FLIGHT INSTRUMENT FLASHING FOR 5 TO 10 SECONDS. "DECLARED EMERGENCY" ACCOMPLISHED A DETAILED VISUAL INSP AFTER LIGHTNING STRIKE IAW W/C NR EX055113-DUI-10000-003 AND NO DEFECTS WERE NOTED. OK FOR SERVICSDR TRBA2010081Brake Sys · malfunctionedCAPT'S SIDE BRAKING ACTION REQUIRES EXCESSIVE BRAKE PEDAL TRAVEL AND EFFORT. PERFORMED CAPT'S SIDE BRAKE BLEEDING IAW JIC NR 32-42-00. TAXI RUN CHECK FOUND SATISFACTORY AT THIS TIME .SDR TRBA2010080Fire Warning · activatedNR 1 ENGINE FIRE INDICATION WHILE HOLDING ON HOLDING SPOT 1 AND IN FEATHER. "DECLARED EMERGENCY" R & R NR 1 LT ENG FIRE EXTINGUISHER BOTTLE AND PERCUSSION CARTRIDGE IAW WORKCARD. ALSO PERFORMED DVI OF ENG FIRE DETECTION IAW EX 261261 DVI-10000-001.SDR COER2010F00175Seat Track · corrodedRT INBD SEAT TRACK COMMON TO FRAMES 29-36 CORRODED BEYOND SRM LIMITS. REMOVED CORROSION FROM MULTIPLE AREAS FRAME 23-29 PITTING CORROSION AT PREVIOUS BLENDED, PRIMED AREAS AT MARKED AREAS FOUND TO BE "OUT OF LIMITS" PER SRM 51-21-42, 53-00-00 FIG 304 REV 77.SDR 2010F00174Seat Track · corrodedLT INBD SEAT TRACK COMMON TO FRAMES 29-36 CORRODED BEYOND SRM LIMITS. (LEVEL II) REMOVED CORROSION PER ATR 72 SRM 51-21-42 REV 77. REMOVED LT INBOARD SEAT TRACK 29-36 PER ATR 72 SRM 51-25-01 REV 77. SEAT TRACK FABRICATED. INSTALLED SEAT TRACK FLOORBEAM 29SDR 2010F00173Seat Track · corrodedLT INBD SEAT TRACK COMMON TO FRAMES 29-36 CORRODED BEYOND SRM LIMITS. (LEVEL II) REMOVED CORROSION PER ATR 72 SRM 51-21-42 REV 77. REMOVED LT O/B SEAT TRACK FROM FRAME 29L TO 36L PER ATR 72 SRM 51-25-04. SEAT TRACK FABRICATED. INSTALLED LT O/B SEAT TRACK FSDR 2010F00172Seat Track · corrodedRT INBD SEAT TRACK COMMON TO FRAMES 21-23 CORRODED BEYOND SRM LIMITS. (LEVEL II) REMOVED SEAT TRACK SECTION FROM BETWEEN FRAMES 20-21 UP TO FRAME 23 PER ATR 72 SRM 51-25-04 REV 77. INSTALLED SPLICE, SEAT TRACK, AND RADIUS BLOCK AT FRAME 23 IAW ATR 72 SRM 51-SDR 2010F00171Seat Track · corrodedRT INBD SEAT TRACK COMMON TO FRAME 23-29 CORRODED BEYOND SRM LIMITS. (LEVEL II) BLENDED OUT SCRATCHES AND CORROSION AT FR 27 LBL325 IAW ATR 72 SRM 51-21-58 REV 77. FOUND TO BE OUT OF LIMITS IAW ATR 72 SRM 53-00-00 REV 77 FIG 304. REMOVED LT I/B SEAT TRACK FSDR 2010F00170Seat Track · corrodedLT INBD SEAT TRACK COMMON TO FRAME 23-29 CORROSION BEYOND SRM LIMITS. (LEVEL II) BLENDED CORROSION ON LT OUTBOARD SEAT TRACK BETWEEN FRAMES 23 AND 29 IAW ATR 72 SRM 51-21-42 REV 77. MEASURED MATERIAL LOSS AT BLEND AREAS AND FOUND VARIOUS AREAS BETWEEN FRAMESSDR 2010F00169Seat Track · corrodedCARGO COMPARTMENT SEAT TRACK LT SIDE AT FLOORBEAM 36-41 HAS CORROSION BEYOND SRM LIMITS. (LEVEL II) REMOVED SEAT TRACK SECTION FROM 38-41 IAW ATR 72 SRM 51-25-04. LOCATED & DRILLED NEW SEAT TRACK FROM FB36-41 IAW ATR 72 SRM 51-25-04 ALL SRM REV 77. INSTALLESDR 2010F00168Seat Track · corrodedCARGO COMPARTMENT SEAT TRACK AT FLOORBEAM 41 RT SIDE HAS (6) INCH AREA IN TRACK WITH CORROSION BEYOND SRM LIMITS. (LEVEL II) REMOVED SEAT TRACK IAW ATR 72 SRM 51-25-04 REV 77. EVALUATED CORRODED AREA AND FOUND TO BE OUT OF LIMITS IAW ATR 72 SRM 53-00-00 FIG SDR 2010F00167Seat Track · corrodedRT OTBD SEAT TRACK FROM FLOORBEAM 29 TO FLOORBEAM 36 HAS PITTING CORROSION AND WEAR BEYOND SRM LIMITS FROM SEAT ATTACHMENTS. REMOVED CORROSION PER ATR 72 SRM 51-21-42 REV 77. REMOVED RIGHT O/B SEAT TRACK FROM 29 TO 36 PER ATR 72 SRM 51-25-01. SEAT TRACK FABSDR 2010F00166Beam · misrepairedFOUND UNAPPROVED SRM REPAIR ON FWD END OF PAX DOOR BEAM 8. REMOVED BEAM 8 IAW ATR 72 SRM 51-25-01 REV 77 AND ATR 72 SRM 51-25-04 REV 77. RECEIVED NEW BEAM PART NUMBER S5217620521401 & MATCH DRILLED TO EXISTING STRUCTURE. INSTALLED BEAM IAW ATR 72 SRM 51-25SDR 2010F00165Intercostal · corrodedPAX CREW DOOR LOWER FWD PAN IS CORRODED OUTSIDE SRM LIMITS APPROXIMATELY 3 INCHES FWD OF BOTTOM SPLICE AT INNER SKIN. (LEVEL II) REMOVED INTERCOSTAL IAW ATR 72 SRM 51-25-01 REV 77. REMOVED CORROSION FROM INTERCOSTAL IAW ATR 72 SRM 51-21-42 REV 77 AND ATR 72 SSDR 2010F00164Intercostal · corrodedPAX CREW DOOR 3RD INTERCOSTAL FROM FWD SIDE BETWEEN BEAM 3 AND 4 IS CORRODED OUT OF SRM LIMITS ON OUTER SKIN FLANGE.(LEVEL II)SDR 2010F00163Intercostal · corrodedPAX DOOR 3RD INTERCOSTAL FROM FWD SIDE BETWEEN BEAM 3 AND 4 IS CORRODED ON OUTER SKIN FLANGE BEYOND SRM LIMITS. REMOVED INTERCOSTAL IAW SRM 51-25-01 REV 77. REMOVED CORROSION FROM INTERCOSTAL IAW SRM 51-21-42 REV 77 & SRM 51-21-58 REV 77. FOUND TO BE OUT OFSDR 2010F00162Attach Fitting · corrodedPAX CREW DOOR LOWER CLEAT ON 4TH INTERCOSTAL FROM FRONT BETWEEN BEAM 3 AND 4 IS CORRODED BEYOND SRM LIMITS. REMOVED CLEAT IAW SRM 51-25-01 REV 77. REMOVED CORROSION FROM CLEAT IAW SRM 51-21-42 REV 77 AND ATR 72 SRM 51-21-58 REV 77. FOUND CLEAT TO BE OUT OF SDR 2010F00161Intercostal · corrodedPAX DOOR SECOND FROM FRONT INTERCOSTAL ABOVE BEAM 6 IS CORRODED BEYOND SRM LIMITS AT LOWER INBD CORNER. REMOVED CLEAT FOR ACCESS IAW ATR 72 SRM 51-25-01 REV 77. REMOVED CORROSION FROM INTERCOSTAL IAW SRM 51-21-42 REV 77 & SRM 51-21-58 REV 77. MEASURED AFFECSDR TRBACPCP2010047Skin · corrodedTHIS IS A FINAL REPAIR OF CORROSION PREVIOUSLY FOUND DURING SCHEDULED MX PHASE CHECK, THE AREAS OF CORROSION WERE FOUND AT LT WING LOWER SURFACE AT T/E BETWEEN RIBS 9-10. COMPLIED WITH TDMI 570424 CORROSION FOUND ON LT AFT WING AREA BTW RIB 9-10 FINAL REPAIR, SDR TRBA2010073Valve · inoperativeDURING APPROACH AT EIS WHEN SELECT THE FLAPS TO 30 DEG. NEVER WENT DOWN, THE FLAPS WITH WENT AROUND, CAME BACK TO SJU AND THE FLAPS NEVER WENT DOWN TO FLAPS 15 OR 30 DEGREES, WITH MAKE A LANDING WITH FLAPS 0 DEG, FLAP 0 DEG LANDING PROCEDURES. R & R BOTH FLAPSDR COER2010FA0000711Skin · corrodedREMOVED CORROSION IAW ATR 72 SRM 57-14-12 PB400 REV 77. FINAL DIMENSION OF .732" - .738" WAS FOUND TO BE OUT OF LIMITS. INSTALLED NEW FOIL + SPACERS ON 521DT ACCESS PNL FOR REWORKED DOOR CUTOUT AS PER SRI DO/TS-3754/10-13808. NOTE: APPLICATION OF SRI DO/T
Back to Aerospatiale ATR 72-212