SDR TRBA2010047Socket · burnedSTRONG BURNING SMELL INSIDE COCKPIT AREA AFTER T/O. RETURN TO MIA FOR PRECAUTIONARY LANDING. FOUND FLUORESCENT TUBE SOCKET AT 290LG BURNED AND MELTING. R & R SOCKET AND TESTED IAW ATR 72 JIC 33-21-23. ALL TEST OK. ACFT OK FOR RETURN TO SERVICE.SDR TRBA2010046Light · inoperativeFRONT HALF OF EMERGENCY LIGHTS IN-OP. AWAITING AML PAGE FOR FURTHER DETAILS.SDR TRBA2010045Wire · brokenEMERGENCY EXIT LIGHT (BOTTOM ON SERVICE DOOR) INOPERATIVE. FOUND BROKEN WIRE AT PIN NR 1 OF EMER EXIT LT 68WL. RESECURED PIN IAW ASM 33-51-00 OPS CHK GOOD NO FURTHER DEFECTS NOTED.SDR TRBA2010044SUPFan · failedSTRONG BURNING ODOR FELT THROUGH OUT THE CABIN AND COCKPIT. NO SIGN OF HEAT SOURCE NOR SMOKE WAS IDENTIFIED. OPENED ALL OVERHEAD BINS AND INSPECTED FOR BURNING ODOR ALL ELECTRICAL COMPONENTS IAW JIC 25-24-21. ALSO OPENED ACCESS DOORS TO ELECTRONIC RACKS AND INSDR TRBA2010044Unknown · odorSMOKE SMELL IN CABIN. EMERGENCY DECLARED. NO HEAT SOURCE OR SMOKE FOUND. AWAITING AML PAGE FOR FURTHER DETAILS.SDR TRBA2010042Bulb · inoperativeEMERGENCY LIGHT MAIN ENTRY STAIRS INOP. ADJUSTED BULB OF MAIN DOOR AND PERFORMED OPT IAW JIC 33-50-00.SDR TRBA2010040SUPWire · brokenTHE EMERGENCY EXIT LIGHT ON THE PASSENGER CABIN ENTRY DOOR IS INOPERATIVE. REMOVED AND REPLACED BROKEN WIRE IAW MM STD PRACTICE 20-42-10 OPS CHECK GOOD.SDR TRBACPCP2010027SPSkin · corrodedLT WING FRONT SPAR BETWEEN ENG AND FUSELAGE 2 LOCK FASTERNERS SURROUNDING CORRODED. COMPLIED WITH LT WING LOWER SKIN CORROSION BLEND OUT IAW EO NR E2-5700-384 ( FWD SPAR RIBS 6 AND 7) DEFFERRED AS (ER TD,O AITJ NR 414570423. FOR FUTURE TOLERANCE INSP AND IAWSDR TRBACPCP2010027Spar · corrodedLT WING FRONT SPAR BETWEEN ENGINE AND FUSELAGE CORROSION AROUND 2 LOCK FASTENER. OPENSDR TRBA2010040Light · inoperativeTHE EMERGENCY EXIT LIGHT ON THE PASSENGER CABIN ENTRY DOOR IS INOPERATIVE. AWAITING AML PAGE FOR FURTHER DETAILS.SDR TRBA2010038Light · inoperativeA PLASTIC OR ELECTRICAL BURNING ODOR IS COMING FROM THE FWD PART OF THE PASSENGER CABIN. R & R FLOURESCENT TUBE AT 2CD IAW JIC 33-21-23 RAI 10000-018 END.SDR TRBA2010036SUPStatic Inverter · hotR & R NR2 STATIC INVERTER IAW JIC 24-21-81 RAI 10000-001.SDR TRBA2010036Unknown · smokeSMELL OF ELECTRICAL SMOKE IN CABIN AND FLIGHT DECK, SMOKE COMING FROM AREA OF 90VU. AWAITING AML PAGE FOR FURTHER DETAILS.SDR TRBACPCP2010034SPSkin · corrodedACCOMPLISHED TDMI 348570288 LT WING LWR SKIN PANEL AT TE BTW RIBS 11-12 TEMPORARY CORROSION BLEND OUT REPAIR. EO E2-57MR-390, REF AMS-NDT-REPORT 8130-3 NR 100505-75.SDR TRBACPCP2010033SPSkin · corrodedACCOMPLISHED TDMI 3485102C8 RT WING AT RIB 13 LWR SURFACE FWD HAS CORROSION TEMPORARY REPAIR AT NEXT C-CHECK PENDING FINAL REPAIR EMBODIMENT OR REPAIR LIFE LIMIT 5 MONTHS IAW AE EO E2-57MR-389. REF AMS-NDT-REPORT 8130-3 NR 100505-73. THIS ACTION CLOSES.SDR TRBACPCP2010032SPSkin · damagedLT WING LOWER SKIN PANEL AT T/E AT RIB 9. TEMPORARY CORROSION BLEND OUT REPAIR IAW AE-E0 NR E2-57MR-388, REF AMS-NDT-REPORT 8130-3 NR 100505-78.SDR TRBACPCP2010031SPSkin · damagedLT WING LOWER SKIN PANEL JACK PAINT AT RIB 10 TEMPORARY CORROSION BLEND OUT REPAIR IAW EO E2-57MR-387 REF AMS NDT REPORT 8130-3 NR 100505-72. THIS ACTION CLOSES TDMI.SDR TRBACPCP2010030SPStructure · damagedREPAIRED RT WING ELECTRO FUEL PUMP SURROUNDING AREA IAW EO E2 57-MR-385 REF AMS NDT REPORT 8/30 3H100505-70.SDR TRBACPCP2010035SPSpar · damagedINSTALLED REPAIR DOUBLER AT RT WING LWR REAR SPAR IAW AE EO E2-57MR-395. REF ART W/O 11951 NRWC 334519, ART FORM L -004-2R1 AND AMS NDT REPORT 100514-13. THIS ACTION CLOSES TDMI 348570218.SDR TRBACPCP2010035Skin · corrodedRT WING LOWER SKIN REAR SPAR AT RIB 12 CORROSION TITANIUM DOUBLER PERMANENT REPAIR. AWAITING COMPLETION OF EO E2-57MR-395 AND AML PAGE FOR FURTHER DETAILS.SDR TRBACPCP2010034Skin · corrodedAN AREA OF CORROSION WAS FOUND AT LT WING LOWER SURFACE AT T/E BETWEEN RIBS 11-12. AWAITING COMPLETION OF EO E2-57MR-390 AND AML PAGE FOR FURTHER DETAILS.SDR TRBACPCP2010033Skin · corrodedAN AREA OF CORROSION WAS FOUND AT RT WING LOWER SKIN AT L/E BETWEEN RIBS 12-13. AWAITING COMPLETION OF EO E2-57MR-389 AND AML PAGE FOR FURTHER DETAILS.SDR TRBACPCP2010032Skin · corrodedAN AREA OF CORROSION WAS FOUND AT LT WING LOWER SKIN AT T/E AT RIB 9. AWAITING COMPLETION OF EO E2-57MR-388 AND AML PAGE FOR FURTHER DETAILS.SDR TRBACPCP2010031Skin · unknownLT WING SKIN AROUND RIB 10 JACK PAD. AWAITING COMPLETION OF EO E2-57MR-387 AMD AML PAGE FOR FURTHER DETAILS.SDR TRBACPCP2010030Structure · corrodedDISCREP: REF AML 434552/4 - RT WING ELECTRO FUEL PUMP SURROUNDING AREA HAS CORROSION. AWAITING COMPLETION OF EO E2-57MR-385 AND AML PAGE.SDR TRBACPCP2010029Pressure Blkhd · corrodedFWD PRESSURE BULKHEAD APPEARS TO HAVE CORROSION AT CONTACT POINTS 5 AND 8. C/W SRI ATR DO/TS 2482/10-13438 AND AE EO E2-53MR-252. REF AMS NDT- REPORT 8130-3 NR 100505-71.SDR TRBA2010035SUPO-Ring · leakingDURING CLIMB OUT WHEN SELECTING BLEED VALVE ON IN THE COCKPIT WE GET A NOXIOUS DIRTY SOCK EXHAUST SMELL. SMELL GOES AWAY WHEN DESELECTING NR 1 BLEED VALVE. R & R LT ENG NR 5, 6, 7 SCAVENGE TUBES O-RINGS IAW MM 72-01-50. NO SMELL NOTED AT THIS TIME, NO LEAKS.SDR TRBA2010035O-Ring · leakingDURING CLIMB OUT WHEN SELECTING BLEED VALVES ON , IN THE COCKPIT WE GET A NOXIOUS DIRTY SOCK EXHAUST SMELL, SMELL GOES AWAY WHEN DESELECTING NR 1 BLEED VALVE. R& R LT ENG NR 5, 6 AND 7 SCAVENGE TUBE O-RINGS IAW MM 72-01-50, NO SMELL NOTED AT THIS TIME, NO LEASDR TRBACPCP2010026Skin · corrodedCORROSION ON LT WING LOWER SKIN AT FUEL MAG STICK. OTBD OF RIB 5 BTW STIFFENERS 5-6. PERFORMED TEMPORARY REPAIR LT WING LOWER SKIN AT FUEL MAG STICK OTBD OF RIB 5 BTW STIFFENERS 5-6. ATR HAS ADVISED THAT DAMAGE CAN REMAIN AS IS UNTIL THE NEXT SCHEDULED C-CHECSDR TRBACPCP2010025Skin · corrodedCORROSION ON LT WING LOWER SKIN AT RIB 10 JACK POINT. PERFORMED TEMPORARY REPAIR LT WING LOWER SKIN AT RIB 10 JACK POINT FOLLOWING SRI INSTRUCTIONS UNTIL NEXT SCHEDULED C-CHECK WHEN A PERMANENT REPAIR WILL BE APPLIED IAW SRI DO/TS-2187/10-13360 ISSUE B AND EO SDR TRBA2010034Unknown · smokeELECTRICAL SMOKE INDICATION ON CAP. SMELL IN COCKPIT & CABIN. SMOKE SOURCE NOT IDENTIFIED. PERFORMED ENG RUN UP TO CHECK ELEC SMK INDICATION CAP PROB ON, COULD NOT DUPLICATED, ADJUSTED ACFT SYS LT PACK HOSE CLAMP, PERFORMED OPT CHECK, WORKING PROPERLY IAW 21SDR TRBACPCP2010022Skin · corrodedCORROSION FOUND ON LT WING JACKING POINT AREA. COMPLIED WITH LT WING, LOWER SKIN CORROSION BLEND OUT TEMPORARY REPAIR AT JACK POINT AT RIB 10 AREA IAW EO E2-57MR-378.SDR TRBACPCP2010021Skin · corrodedCORROSION FOUND ON LT WING FUEL DRAIN (INNER) SURROUNDING AREA. COMPLIED WITH LT WING, LOWER SKIN CORROSION BLEND OUT TEMPORARY REPAIR AT FUEL DRAIN BTW RIBS 4-5 AREA IAW EO NR E2-57MR-377.SDR TRBACPCP2010020Structure · corrodedCORROSION FOUND ON LT WING FUEL PUMP SURROUNDING AREA. COMPLIED WITH LT WING, LOWER SKIN CORROSION BLEND OUT TEMPORARY REPAIR AT FUEL PUMP CUT-OUT AREA IAW EO NR E2-57MR-376.SDR TRBA2010029Lamp · failedEMERGENCY FLOOR PATH LIGHTING INOP AT PAX SEAT 10B. RELAMPED EMERGENCY FLOOR PATH LIGHT BULB IAW JIC NR 33-50-00.SDR TRBA2010028Lamp · weakEMERGENCY LIGHT (FLOOD LIGHT) LT FUSELAGE DIM. REPLACED LT FUSELAGE LIGHT OPS CK IAW MM 33-51-25.SDR TRBA2010027Lamp · burned outEMERGENCY LIGHTS (FLOOD LIGHTS) RT FUSELAGESE OUT. REPLACED FLOOD LIGHT RT FUSELAGE IAW MM 33-51-23.SDR TRBA2010026Lamp · burned outEMERGENCY EXIT LIGHT ON STAIRS 1S OUT. RELAMPED EMERGENCY LIGHT REF JIC 33-50-00.SDR TRBACPCP2010028Hinge · corrodedCORROSION RT WING INBD L/E HINGE BETWEEN RIB 4 AND 5. REMOVED CORROSION ON RT WING L/E HINGE BETWEEN RIB 4 AND 5 IAW SRM 57-12-10, COMPLIED WITH NR DO/TS-1754/10-13248, NR DO/TS-1754/10, 5667 AND EO E2-57MR-374.SDR TRBACPCP2010036Bulkhead · corrodedCORROSION ON CONTACT POINT AT FWD PRESSURE BULKHEAD. C/W SRI DO/TS-1767/10-13252, REF NDT REPORT AMS INC 100326-25 FOR UT AN HFEC VALUES. NO CRACKS NOTED AT THIS TIME. C/W ATR72 SRAS DO/TS - 1767/10 5668 SUPPLEMENTARY INSP, DUI OF BLENDED AREAS EVERY 2 YRS FORSDR TRBA2010023SUPGround Wire · failedELECTRICAL SMOKE ODOR IN COCKPIT. R & R GPU GROUND CABLE 440VN IAW JIC NR 24-46-11.SDR TRBA2010024Power Supply · failedEMERGENCY LIGHT OUT FROM SEAT 14AB TO THE EMERGENCY SIGNS IN THE BACK OF THE CABIN. R & R POWER SUPPLY AND BATTERY FOR EMERG LIGHT IAW 33-51-21 EX 33-51-21, CYC 29580.SDR TRBA2010023Unknown · odorELECTRICAL SMOKE ODOR IN COCKPIT. AWAITING NRWC FOR FURTHER DETAILS.SDR TRBA2010022Lamp · burned outACFT AIR INTERRUPT. AFT SMOKE WENT OFF MOMENTARILY. INSPECTED CABIN, LAVATORY, BOTH AFT CARGO COMPTS. AND AT THIS TIME NO EVIDENCE OF SMOKE OR SMOKE SMELL WERE NOTED ONLY FOUND 2 CEILING LAMPS BURNED OUT AT 15 & 16 AB PERFORMED AN OPS CK OF THE SMOKE DETECTISDR TRBA2010021SUPFire Warning · false activationDURING TAXI FOR TAKEOFF NR 1 ENG FIRE WARNING ACTIVATED, WHEN THE ENGINE WAS SHUTDOWN, THE INDICATION WENT OUT. PERFORMED DVI OF THE FIRE DETECTION SYS IAW JIC 26-12-61 DVI 10000 - PERFORMED IDLE RUN. ALL SYS NORMAL AT THIS TIME. NO DEFECTS FOUND. (THE CAPT DSDR TRBA2010021Fire Warning · illuminatedDURING TAXI FOR TAKOFF, NR 1 ENG FIRE WARNING ACTIVATED, WHEN ENG WAS SHUTDOWN, THE INDICATION WENT OUT. EMERGENCY DECLARED. PERFORMED DVI OF ENGINE FIRE DETECTION SYS IAW JIC 26-12-61 DVI10000 - PERFORMED IDLE RUN. ALL SYS NORMAL AT THIS TIME. NO DEFECTS FOSDR TRBA2010019Brake · weakSIDE LT BRAKE PEDAL IS TOO LOW BEFORE BRAKING ACTION. PERFORMED OPS TEST TO BRAKING SYS FOUND OK IAW JIC 32-42-00. NORMAL BRAKING.SDR TRBA2010020SUPEngine · malfunctionedON APPROACH RT ENGINE TQ AND NP WENT TO 0 PERCENT, NH AND ITT STILL SHOWED 76 PERCENT AND 400 PERCENT, PLANE YAWED SHARPLY DURING EVENT. PERFORMED ENGINE GROUND OPS CHECK IAW EX-055007-CS-20000-001 AND FOUND WORKING OK, CANNOT DUPLICATE PROBLEM ON GROUND. TACSDR TRBA2010017SUPWire · brokenUNABLE TO LOWER FLAPS, FLAPS STAY AT "0" DEGREES REGARDLESS OF HANDLE POSITION. EMERGENCY DECLARED. REPAIRED A BROKEN WIRE AT LT FLAP TRANSMITTER CONNECTOR 15CVA IAW MM STANDARD PRACTICES CHAP 20-27-17. OPS TEST IAW JIC 27-51-00-10000 AND FOUND WORKING PROPERLSDR TRBA2010017Flap System · inoperativeFLAPS WOULD NOT EXTEND WHEN HANDLE MOVED. EMERGENCY DELCARED. AWAITING AML PAGE FOR FURTHER DETAILS.
Back to Aerospatiale ATR 72-212