Airbus A319-111
Service difficulty reports · 2,475
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A319111' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A319111' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR F3LA2009102600219Sill · corrodedREFERENCE NON ROUTINE C072351. DURING DEN C6 C-CHECK, INSPECTION NOTED CORROSION ON THE L2 DOOR SILL BEAM NUT PLATE HOLE AT FRAME 66. MAINTENANCE CUT OUT DAMAGED AREA, FABRICATED REPAIR ANGLE AND COMPLETED REAPIR IAW SRM 51-42-11, SRM 53-41-14, SRM 51-75-12 ANSDR F3LA2009101900213Blanking Plate · corrodedDURING C3 C-CHECK, INSPECTION NOTED THE R2 DOOR AFT BLANKING PLATE WAS CORRODED. MX INSTALLED NEW BLANKING PLATE IAW AMM 52-13-31-400-007.SDR F3LA2009101900212Blanking Plate · corrodedDURING DEN C3 C-CHECK, INSPECTION THE R2 DOOR FWD BLANKING PLATE WAS CORRODED. MX INSTALLED NEW BLANKING PLATE IAW AMM 52-13-31-400-007.SDR F3LA2009101900211Blanking Plate · corrodedDURING C3 C-CHECK, INSP NOTED THE L2 DOOR AFT BLANKING PLATE WAS CORRODED ON THE UPPER SURFACE. MX INSTALLED NEW BLANKING PLATE IAW AMM 52-13-31-400-007.SDR F3LA2009101900210Blanking Plate · corrodedDURING C3 C-CHECK, INSP NOTED THE L2 DOOR FWD BLANKING PLATE WAS CORRODED ON THE UPPER SURFACE. MX INSTALLED NEW BLANKING PLATE IAW AMM 52-13-31-400-007.SDR F3LA2009101900209Floor Panel · corrodedDURING C3 C-CHECK, INSP NOTED THAT FLOOR PANEL 261FF WAS CORRODED BEYOND ALLOWABLE LIMITS. MX REMOVED AND REPLACED THE FLOOR PANEL IAW C-CHECK TASK CARD.SDR F3LA2009101900208Floor Panel · corrodedDURING C3 C-CHECK, INSP NOTED THAT FLOOR PANEL 262FF WAS CORRODED BEYOND ALLOWABLE LIMITS. MX REMOVED AND REPLACED THE FLOOR PANEL IAW C-CHECK TASK CARD.SDR F3LA2009101900207Floorbeam · corrodedDURING C3 C-CHECK, INSP NOTED CORROSION ON FLOORBEAM -Y1292, AFT OF FRAME 68 COUPLING SPLICE POINT. MX REMOVED AND REPLACED THE FLOORBEAM IAW SRM 53-00-14, 51-44-11 AND 51-42-11.SDR F3LA2009101900206Floorbeam · corrodedDURING C3 C-CHECK, INSP, NOTED CORROSION AROUND THE NUT CLIP HOLES ON FLOORBEAM 1292 (RT) BETWEEN FRAME 66 AND FRAME 68. MX REMOVED AND REPLACED THE FLOORBEAM IAW SRM 53-00-14, 51-42-11 AND 51-44-11.SDR F3LA2009101600205Floorbeam · corrodedDURING C3 C-CHECK INSP NOTED, THE AFT GALLEY HAS CORROSION AROUND THE NUT CLIP HOLES FLOORBEAM 1292, LT SIDE BETWEEN FRAME 66 AND FRAME 68. MX REMOVED AND REPLACED FLOORBEAMS IAW SRM 51-42-11, SRM 53-00-14 AND SRM 51-72-11.SDR F3LA2009101600204Shear Plate · corrodedDURING C3 C-CHECK, INSP NOTED AFT GALLEY LT LATERAL SHEAR PLATE CORRODED BETWEEN FRAME 68 AND FRAME 70. MX REMOVED AND REPLACED SHEAR PLATE IAW SRM 51-42-11, SRM 51-44-11 AND SRM 51-72-11.SDR F3LA2009101600203Shear Plate · corrodedDURING C3 C-CHECK, INSP NOTED AFT GALLEY RT LATERAL SHEAR PLATE CORRODED BETWEEN FRAME 68 AND FRAME 70. MX REMOVED AND REPLACED SHEAR PLATE IAW SRM 51-42-11 AND SRM 51-44-11.SDR F3LA2009101600202Support · crackedREFERENCE NON-ROUTINE C071806. DURING DEN C3 C-CHECK, INSP NOTED THE NR 2 ENG OTBD PYLON RIB SUPPORT WAS CRACKED ABOUT RIB 7. MX REMOVED AND REPLACED SUPPORT IAW SRM 51-42-11, SRM 51-44-11, SRM 51-26-00, SRM 54-52-12 AND SRM 51-42-00.SDR F3LA2009101500201Fitting · out of rigPILOT REPORTS AN INTERMITTENT WARNING FOR THE R2 CABIN DOOR SLIDE ON THE ELECTRONIC CENTRALIZED ACFT MONITORING SYS. MX FOUND THE R2 GIRT BAR FITTING OUT OF RIG. MX RIGGED THE GIRT BAR FITTINGS IAW AMM 52-13-22-820-056 AND INSTALLED SLIDE ASSEMBLY IAW AMM 25SDR F3LA2009101300200Profile · corrodedDURING C4 C-CHECK, INSP NOTED THE LT PROFILE AT FRAME 56 TO FRAME 58 HAS CORROSION AROUND THE FASTENER HOLES. MX REMOVED AND REPLACED THE PROFILE IAW SRM 51-42-11 PARAGRAPH 7.SDR F3LA2009101300199Profile · corrodedDURING C4 C-CHECK, INSP NOTED THAT THE PROFILE AT FRAME 59 AND STR 38R TO 38L HAD CORROSION AROUND THE FASTENER HOLES. MX REMOVED AND REPLACED THE PROFILE IAW SRM 51-73-11 AND 51-42-11 PARAGRAPH 7.SDR F3LA2009100900198Frame · corrodedDURING C4 C-CHECK, INSP NOTED AFT PIT FRAME 52 CTR TIE DOWN POINT HAS EVIDENCE OF CORROSION AT FASTENER HOLES. MX REMOVED AND REPLACED PLATE IAW SRM 51-42-11, SRM 53-41-14, SRM 51-31-00 AND SRM 51-72-11.SDR F3LA2009100900197Profile · corrodedDURING C4 C-CHECK, INSP NOTED PROFILE ON FRAME 56 FROM STR 41 RT TO 38 LT IN AFT PIT FOR THE FLOORBOARD PANEL SHOWS SIGNS OF CORROSION AROUND FASTENER HOLES. MX REMOVED AND REPLACED PROFILE IAW SRM 51-42-11 AND SRM 51-72-11.SDR F3LA2009100900196Profile · corrodedDURING C4 C-CHECK, INSP NOTED THE PROFILE ON FRAME 58 FROM STR 41 RT TO 38 LT IN AFT PIT FOR THE FLOORBOARD PANEL SHOWS SIGNS OF CORROSION AROUND FASTNER HOLES. MX REMOVED AND REPLACED PROFILE IAW SRM 51-42-11, SRM 51-44-11, SRM 51-46-11 AND SRM 51-72-11.SDR F3LA2009100500194Hook · brokenDURING C6 C-CHECK, INSP NOTED THAT THE L1 DOOR HANDLE WAS ABLE TO CLOSE WITHOUT THE DOOR BEING IN THE CLOSED POSITION. MX REMOVED AND REPLACED THE L1 DOOR HOOK ASSY IAW AMM 52-11-21-400-001.SDR F3LA2009100500195Floor Panel · corrodedDURING C6 C-CHECK, INSP NOTED THE L2 ENTRY DOOR FLOOR PANEL HAS SEVERAL SPOTS OF CORROSION AROUND FASTENER HOLES. MX REMOVED AND REPLACED THE FLOOR PANEL AT POSITION 261FF, IAW TASK CARD C534103-02.SDR F3LA2009100100189Stringer · corrodedDURING C6 C-CHECK, INSP NOTED CORROSION ON STR 44, SIX INCHES AFT OF FRAME 65 NEAR POTABLE WATER SERVICE PANEL. MX CUT OUT DAMAGED AREA, FABRICATED REPAIR STR AND INSTALLED IAW SRM 53-00-13, 51-42-11, 53-41-13 AND 51-21-11.SDR F3LA2009100100188Hook · brokenDURING C6 C-CHECK, INSP NOTED THE R2 DOOR CLOSING BEFORE DOOR WAS IN DOOR JAM. MX REMOVED AND REPLACED THE HOOK AT THE R2 DOOR HANDLE IAW AMM 52-13-21-400-001.SDR F3LA2009100100187Shear Plate · corrodedDURING C6 C-CHECK, INSP NOTED THE LT HAND SHEAR PLATE AT Y1292 BETWEEN FRAME 69 AND FRAME 70 WAS CORRODED AT THE AFT SCREW HOLE. MX REMOVED AND REPLACED THE SHEAR PLATE IAW SRM 51-42-11, 51-72-11, 51-44-11 AND 51-23-11.SDR F3LA2009100100186Floorbeam · corrodedDURING C6 C-CHECK, INSP NOTED CORRODED FASTENER HOLES AT STATION -Y1292 AND FRAME 66. MX REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-42-11 AND 51-44-11.SDR F3LA2009100100193Shear Plate · corrodedDURING C6 C-CHECK, INSPECTION NOTED THE RT SHEAR PLATE AT Y1732 BETWEEN FRAME 69 AND FRAME 70 HAS CORROSION. MX REMOVED AND REPLACED THE SHEAR PLATE IAW SRM 51-44-11 AND 51-42-11.SDR F3LA2009100100192Sill · corrodedDURING C6 C-CHECK, INSPECTION NOTED THE L2 DOOR SILL HAS SEVERAL AREAS OF CORROSION. MX REMOVED AND REPLACED THE DOOR SILL IAW SRM 51-42-11 AND D53408505.SDR F3LA2009100100184Floorbeam · corrodedSUPPLEMENTAL INFORMATION: REFERENCE NON ROUTINE C070051. DURING DEN C6 C-CHECK, INSPECTION NOTED CORROSION AROUND THE NUT PLATES LOCATED AT R2, Y1292 BETWEEN FRAME 66 AND FRAME 68. MAINTENANCE REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-44-11 AND 51-42-11.SDR F3LA2009100100191Floorbeam · corrodedDURING C6 C-CHECK, INSP NOTED THE COUPLING ATTCH POINT AT L2, STATION Y1292 AND FRAME 68 HAS CORROSION. MX REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-42-11 AND DWG SD53472815 AND D53472780.SDR F3LA2009100100190Floorbeam · corrodedDURING C6 C-CHECK, INSP NOTED CORROSION AROUND THE NUT PLATES AT L2, STATION Y1292 BETWEEN FRAME 66 AND FRAME 68. MX REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-42-11 AND DWG SD53472815.SDR F3LA2009100100185Floorbeam · corrodedDURING C6 C-CHECK, INSP NOTED THE COUPLING ATTACH POINT AT STATION Y1292 AND FRAME 68 HAS CORROSION. MX REMOVED AND REPLACED THE FLOORBEAM IAW SRM 53-41-14, 51-42-11 AND 51-44-11.SDR F3LA2009092500183Strut · corrodedLINE MX PERFORMED THE LT MLG STRUT REPACK AND FOUND CORROSION ON THE MAIN FITTING BORE WHERE THE LWR BRG IS INSTALLED. MX REMOVED THE CORROSION, PERFORMED NDT OF AREA, FLAP PEENED AREA, CADMIUM PLATED AREA, APPLIED PRIMER TO AREA AND REASSEMBLED STRUT. REF EASDR F3LA2009091700182Profile · corrodedDURING C5 C-CHECK, INSPECTION NOTED THE PROFILE LOCATED BETWEEN THE FORWARD AND AFT FLOOR PANELS AT FRAME 28 HAD CORRODED ATTACH HOLES. MAINTENANCE REMOVED AND REPLACED THE PROFILE IAW SRM 51-72-11.SDR F3LA2009091700180Profile · corrodedDURING C5 C-CHECK, INSPECTION NOTED THAT THE PROFILE LOCATED BETWEEN FRAME 24.5 AND FRAME 28, HAD CORROSION AROUND THE FLOOR PANEL ATTACH HOLES. MAINTENANCE REMOVED AND REPLACED THE PROFILE IAW SRM 51-72-11.SDR F3LA2009091700179Profile · corrodedDURING C5 C-CHECK, INSPECTION NOTED THAT THE PROFILE AT FRAME 28 IN THE FORWARD CARGO PIT HAD CORRODED FLOOR PANEL ATTACH HOLES. MAINTENANCE REMOVED AND REPLACED THE PROFILE IAW SRM 51-72-11 AND 51-42-11.SDR F3LA2009091700178Profile · corrodedDURING C5 C-CHECK, INSPECTION NOTED THE PROFILE AT FRAME 34 IN THE FORWARD CARGO PIT HAD CORRODED FLOOR PANEL ATTACH HOLES. MAINTENANCE REMOVED AND REPLACED THE PROFILE IAW SRM 51-72-11 AND 51-42-11.SDR F3LA2009091700181Control Cable · lack of lubeDURING C5 C-CHECK, INSPECTION NOTED THAT THE RT OVERWING EXIT FLEX CONTROL CABLE FOR THE INFLATION RESERVOIR FAILED THE FUNCTIONAL TEST. MAINTENANCE LUBRICATED THE OVERWING EXIT CONTROL CABLE IAW AMM 52-21-00-720-001 AND AMM 25-62-00-640-001.SDR F3LA2009091700177Roll Pin · shearedDURING DEN C5 C-CHECK, INSPECTION NOTED THAT THE LT EMERGENCY EXIT DOOR LOCKING PIN WILL NOT LOCK IN THE ARMED POSITION. MAINTENANCE REMOVED AND REPLACED THE ROLL PIN THAT HOLDS THE LOCKING PIN IN PLACE PER AMM 52-21-11-400-003.SDR F3LA2009091700176Profile · corrodedDURING DEN C5 C-CHECK, INSPECTION NOTED CORROSION BETWEEN FRAME 28 AND FRAME 30 ON THE AFT RIGHT HAND FLOOR PROFILE ATTACH HOLES. MAINTENANCE REMOVED AND REPLACED THE PROFILE IAW SRM 51-42-11 AND 51-72-11 PARAGRAPH 6.SDR F3LA2009091000175Doubler · damagedREFERENCE NON ROUTINE C068922. DURING C-6 C-CHECK, INSPECTION NOTED PYLON HYDRAULIC LINE FEED THROUGH DOUBLER, DAMAGED AT MAIN PRESSURE LINE. MAINTENANCE REPAIRED IAW ENGINEERING AUTHORIZATION A9-57R-31339.SDR F3LA2009091000174Stringer · corrodedREFERENCE NON ROUTINE C068872. DURING C6 C-CHECK, INSPECTION NOTED STRINGER 43 LT HAS SPOTS OF CORROSION AROUND FASTNER HOLES AT FRAME 34. MAINTENANCE REPAIRED IAW EA A9-53R-31316.SDR F3LA2009091000173Skin · corrodedREFERENCE NON ROUTINE C068738. DURING C6 C-CHECK, INSPECTION NOTED CORROSION ON RIVET IN SKIN CENTER HOLE AT CENTER FAIRING ON FORWARD CARGO PIT FORWARD OF FRAME 34 AT STRINGER 42LH. MAINTENANCE REPAIRED IAW ENGINEERING AUTHORIZATION A9-53R-31316.SDR F3LA2009091000167Skin · corrodedDURING C6 C-CHECK, INSPECTION NOTED HOLE CLOSEST TO STRINGER 44CL BETWEEN FRAME 30 AND FRAME 34 SHOWED INDICATION OF CORROSION. MAINTENANCE REPAIRED IAW EA A9-53R-31316.SDR F3LA2009091000165Skin · corrodedDURING DEN C6 C-CHECK, INSPECTION NOTED CORROSION ON FUSELAGE SKIN AT BS 13227 BETWEEN STRINGER 42R AND 43R. MAINTENANCE REPAIRED IAW EA A9-53R-31316.SDR F3LA2009091000172Skin · corrodedREFERENCE NON ROUTINE C068733. DURING C6 C-CHECK, INSPECTION NOTED CORROSION ON FUSELAGE SKIN ON INSIDE FORWARD CARGO PIT FORWARD OF FRAME 34 BETWEEN STINGER 42L AND 42R AROUND FASTNER HOLES FOR CENTER FAIRING. MAINTENANCE REPAIRED IAW ENGINEERING AUTHORIZATIOSDR F3LA2009091000171Skin · corrodedREFERENCE NON ROUTINE C068734. DURING DEN C6 C-CHECK, INSPECTION NOTED CORROSION ON FUSELAGE SKIN AROUND RIVET HOLE NR 12 IN FORWARD CARGO PIT FORWARD OR FRAME 34 BETWEEN STRINGER 43 LT AND CENTER LINE. MAINTENANCE REPAIRED IAW EA A9-53R-31316.SDR F3LA2009091000170Skin · corrodedDURING DEN C6 C-CHECK, INSPECTION NOTED CORROSION ON FUSELAGE SKIN AROUND RIVET HOLE NUMBER TEN MARKED IN FORWARD CARGO PIT FOUR INCHES FORWARD OF FRAME 34 ON STINGER 43LH. MAINTENANCE REPAIRED IN REFERENCE TO ENGINEERING AUTHORIZATION A9-53R-31316.SDR F3LA2009091000169Skin · corrodedREFERENCE NON ROUTINE C068736. DURING DEN C6 C-CHECK, INSPECTION NOTED CORROSION ON RIVET AND SKIN SECOND HOLE INBOARD OF 41LH AT CENTER FAIRING IN FORWARD CARGO PIT FORWARD OF FRAME 34. MAINTENANCE REPAIRED IN REFERENCE TO ENGINEERING AUTHORIZATION A9-53R-313SDR F3LA2009091000168Skin · corrodedDURING DEN C6 C-CHECK, INSPECTION NOTED CORROSION ON RIVET AND SKIN, FIRST OPEN HOLE OUTBOARD OF STRINGER 43LH AT CENTER FAIRING IN FORWARD CARGO PIT FORWARD OF FRAME 34. MAINTENANCE REPAIRED IAW ENGINEERING AUTHORIZATION A9-53R-31316.SDR F3LA2009091000166Skin · corrodedREFERENCE NON ROUTINE C068740. DURING DEN C6 C-CHECK, INSPECTION NOTED CORROSION ON FUSELAGE SKIN AROUND RIVET HOLE NUMBER 5 IN FORWARD CARGO PIT 7.5 INCHES FORWARD OF FRAME 34 AND ONE HOLE OUTBOARD OF STRINGER 42 LEFT HAND. MAINTENANCE REPAIRED IAW ENGINEERIN
Back to Airbus A319-111