What was found
DURING C6 C-CHECK, INSP NOTED CORROSION ON STR 44, SIX INCHES AFT OF FRAME 65 NEAR POTABLE WATER SERVICE PANEL. MX CUT OUT DAMAGED AREA, FABRICATED REPAIR STR AND INSTALLED IAW SRM 53-00-13, 51-42-11, 53-41-13 AND 51-21-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C6 C-CHECK, INSP NOTED CORROSION ON STR 44, SIX INCHES AFT OF FRAME 65 NEAR POTABLE WATER SERVICE PANEL. MX CUT OUT DAMAGED AREA, FABRICATED REPAIR STR AND INSTALLED IAW SRM 53-00-13, 51-42-11, 53-41-13 AND 51-21-11.