SDR AALA202002139021Hinge Fitting · wornAIRCRAFT WAS GROUNDED: RIGHT ELEVATOR #2 HINGE HAS EXCESSIVE PLAY / WEAR ON THE RIGHT HAND HORIZONTAL STABILIZER. REPLACED HINGE FITTING PER AMM 55-16-42.SDR AALA202002139020Hinge Fitting · wornAIRCRAFT WAS GROUNDED: RIGHT ELEVATOR #1 HINGE HAS EXCESSIVE PLAY / WEAR ON THE RIGHT HAND HORIZONTAL STABILIZER. REPLACED HINGE FITTING PER AMM 55-16-42.SDR ASAA2020021213148Shear Plate · corrodedAFT WET AREA R/H LATERAL SHEAR PLATE AT FR69-FR70 HAS CORROSION GROUNDED - YES. REMOVED AND REPLACED AFT WET AREA R/H LATERAL SHEAR PLATE AT FR69-FR70 IAW A319 SRM 51-42-11 AND DWG D53474180.SDR AALA202002129019Attach Fitting · wornAIRCRAFT IN BASE MAINTENANCE: RIGHT HAND MAIN LANDING GEAR DOOR ACTUATOR FITTING ON KEEL BEAM RIB W10 AFT LUG WORN BETWEEN FR 42 AND FR 43. REPLACED FITTING PER EA 303090 AND SRM 51-72-11.SDR AALA2020021109053Hinge · corrodedAIRCRAFT WAS GROUNDED: LEFT WING AILERON HINGE #3 IS CORRODED / GALLED AND THE LOWER BOLT IS SEIZED. REPLACED HINGE PER AMM 57-51-31.SDR AALA2020021109052Hinge · corrodedAIRCRAFT WAS GROUNDED: LEFT WING AILERON HINGE #2 IS CORRODED / GALLED AND THE LOWER BOLT IS SEIZED. REPLACED HINGE PER AMM 57-51-31.SDR AALA2020021109073Battery Pack · inoperativeAIRCRAFT WAS NOT GROUNDED: FLASHLIGHT AT 2R WAS NOT "BLINKING". MAINTENANCE REPLACED BATTERY ON EMERGENCY FLASHLIGHT AT 2R PER AMM 25-65-00.SDR AALA2020021109072Battery Pack · inoperativeAIRCRAFT WAS NOT GROUNDED: FLASHLIGHT AT 2L WAS NOT "BLINKING". MAINTENANCE REPLACED BATTERY ON EMERGENCY FLASHLIGHT AT 2L PER AMM 25-65-00.SDR AALA202002109002Battery · inoperativeAIRCRAFT WAS NOT GROUNDED: EMERGENCY FLASHLIGHT INOPERATIVE. MAINTENANCE REPLACED FLASHLIGHT BATTERY PER STANDARD PRACTICES.SDR AALA202002109070Light · inoperativeAIRCRAFT WAS NOT GROUNDED: SEAT 12C EMERGENCY PATH LIGHTING INOPERATIVE. ***SUPPLEMENTAL TO UPDATE SECTION 4 AND SECTION 5. MAINTENANCE REPLACED SEAT EMERGENCY LIGHT AT 12C PER CMM 25-22-52.SDR AALA2020021109063Smoke Detector · false activationAIRCRAFT WAS NOT GROUNDED: DURING DESCENT ECAM WARNING "SMOKE - LAVATORY SMOKE" CAME ON THEN EXTINGUISHED, THEN REPEATED TWO TIMES WITHIN ONE MINUTE. FLIGHT ATTNDANT CHECKED FWD LAV. NO SMOKE NOTED. REPLACED SMOKE DETECTOR PER AMM 26-17-00-710.SDR WX0A2020020573466Warning Message · false activation(EMERGENCY DECLARED) HYD GREEN ENG 1 PUMP LO PR., HYD G RV1. LO / PERFORMED CHECK FOR CAVITATION, FOUND NO HYDRAULIC DPI'S EXTENDED OR PHYSICAL DAMAGE TO PUMP, AND NO SIGN'S OF LEAKS"SDR AALA202002039013Rudder · vibrationDIVERTED TO MIA SOON AFTER TAKE-OFF. THE CREW FELT A VIBRATION FROM THE RUDDER DURING TAK-OFF, FOLLOWED BY A STRONG ODOR OF "BURNING OIL" COMING FROM THE FC GALLEY AND REACHING UP TO SEAT ROW 16. ACCOMPLISHED WORK CARD #26L00021001. NO ODOR FOUND.SDR AALA202002039038Fitting · wornAIRCRAFT IN BASE MAINTENANCE: RIGHT MAIN LANDING GEAR DOOR ACTUATOR FITTING AFT LUG WORN WITH BUSHING MIGRATION. REPLACED FITTING PER EA 302675.SDR AALA202002039004Flashlight · inoperativeAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT FLASHLIGHT 1L INOPERATIVE. MAINTENANCE REPLACED FLASHLIGHT PER AMM 25-65-00.SDR WX0A2020020373463Hose · failed(RMERGENCY DECLARED) G SYS LO PR / REPLACED FLEX HOSE OLD ELBOW FITTING"SDR F3LA20200203005Line · crackedHYD GREEN RSVR LOW LEVEL. R&R #1 ENGINE HYDRAULIC LINE PER AMM 20-33-11-911-001A, IPC 29-11-06 FIGURE 02E ITEM 220. OPS AND LEAK CHECK OK ON ALL SYSTEMS, NO LEAKS NOTED. SEE LP 1182557 ITEM 3 FOR ADDITIONAL INFORMATION. PERFORMED OPS TASK 32-00-00-481-003A DUSDR AALA2020013109006Cylinder · low pressureAIRCRAFT WAS NOT GROUNDED: R1 DOOR EMERGENCY CYLINDER PSI LOW. MAINTENANCE SERVICED DOOR CYLINDER TO PROPER PRESSURE PER AMM 52-10-00.SDR AALA202001309016Battery · no testAIRCRAFT NOT GROUNDED: THE EMERGENCY LIGHT TEST ON THE PTP PANEL 110RH FAILED TEST. THESCREEN READ ATA 31-51-38 EPSU BAT AFT LH. REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNIT 13WL IAW AMM 33-51-38.SDR AALA2020012989011Damper · low pressureAIRCRAFT WAS NOT GROUNDED: L1 ENTRY DOOR DAMPER REQUIRED SERVICE. MAINTENANCE SERVICED DOOR DAMPER TO PROPER PRESSURE IAW AMM 52-10-00.SDR AALA202001289007Slide · dislodgedAIRCRAFT WAS GROUNDED: WHEN DOOR WAS OPENED SLIDE CAME OUT OF BUSSLE...DOOR WAS DISARMED PRIOR TO OPENING. REPLACED L1 DOOR SLIDE IAW JPC 26L00025011.SDR AALA202001279017Connector · unsecureAIRCRAFT WAS NOT GROUNDED: DURING ACCOMPLISHMENT OF JOBCARD 26L20025014, AN EMERGENCY POWER SUPPLY FAULTED. MAINTENANCE SECURED THE CONNECTOR ON THE POWER SUPPLY AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA202001279001Brake Assy · malfunctionedAIRCRAFT NOT GROUNDED: AFTER LANDING DURING LOW SPEED EXIT SEVERE LANDING GEAR VIBRATION DURING LIGHT BRAKING LO AUTOBRAKES HAD BEEN USED GROUND VEHICLE REPORTED ALL TIRES OK TAXI IN WAS NORMAL. INSPECTED MLG, FOUND THE NR 1 TIRE WITH LOW PRESSURE, SERVICED TSDR WX0A202001273460Battery Pack · no testESPU TEST FAILS ON OPERATIONAL CHECK. / REPLACED BATTERY ON ESPU.SDR AALA202001279004Power Supply · no testAIRCRAFT WAS GROUNDED, FORWARD CABIN EMERGENCY LIGHTS INOPERATIVE. MAINTENANCE REPLACED THE POWER SUPPLY IAW AMM 33-51-38.SDR AALA202001249012Floor Panel · delaminatedAIRCRAFT WAS GROUNDED: AFT CARGO COMPARTMENT FLOOR PANEL 151VG DELAMINATED FORWARD OF CARGO DOOR. REPLACED FLOOR PANEL PER AMM 25-55-11.SDR AALA202001239001Brake Sys · malfunctionedAIRCRAFT NOT GROUNDED: NON NORMAL BRAKING APPLICATION BETWEEN 70 KTS AND 10 KTS ON LANDING ROLLOUT HAD INTERMITTENT GRABBING. ACCOMPLISHED BSCU #1 AND 2 BRAKE TEST, NO FAULTS DETECTED. INSPECTECTED BRAKE VISUALLY AND CYCLE BRAKES, NO DEFECTS NOTED.SDR AALA202001239003Engine · abnormalAIRCRAFT WAS GROUNDED: DURING PRETAKE-OFF RUN UP OF ENGINES. ADVANCED BOTH ENGINES TO THE 50% POSITION ENGINE NO.1 ACCELERATED NORMALLY BUT ENGINE NO.2 LAGGED BY MORE THAN 50 PERCENT AFTER BOTH ENGINES STABILIZED ADVANCED TO FIX/MCT WAS NORMAL. NO OTHER ABNORSDR AALA202001229012Light · unknownAIRCRAFT NOT GROUNDED: DOOR 2R EMERGENCY EXIT LIGHTS INOPERTIVE. OPS CK OF EMERGENCY EXIT LIGHTS OK IAW AMM 33-50-00.SDR AALA2020012329005Flashlight · inoperativeAIRCRAFT WAS NOT GROUNDED: AFT GALLEY FLASHLIGHT INOPERATIVE. MAINTENANCE REPLACED FLASHLIGHT PER STANDARD PRACTICES.SDR AALA202001219014Unknown · odorAIRCRAFT WAS GROUNDED: STRONG OIL ODOR WITH APU BLEED ON. PERFORMED JC'S 26L00021001 AND 26L00021002. FOUND APU TO BE SOURCE OF ODOR. FURTHER T/S IAW TSM 49-00-81-810-874-A. APU COMP. HAS NO EVIDENCE OF LEAKS. FOUND AFT HYD. SEAL DRAIN COLLECTOR TANK OVERFLOWISDR AALA202001219012Oil Cooler · leakingAIRCRAFT WAS GROUNDED: DIRTY SOCK SMELL ON DECENT. REMOVED AND REPLACED APU OIL COOLER FAN IAW AMM 49-52-51.SDR AALA2020012199002Sliding Window · bindingAIRCRAFT WAS GROUNDED: CAPTAINS SLIDING WINDOW VERY DIFFICULT TO OPEN, EVEN WITH 2 HANDS, VERY HARD TO UNLATCH. ADJUSTED HANDLE OF CAPTAINS SLIDING WINDOW PER AMM 56-12-11-400-001A. OPERATIONAL CHECKED GOOD.SDR AALA2020012189001Cylinder · low pressureAIRCRAFT WAS NOT GROUNDED: L1 DOOR EMERGENCY CYLINDER/ACCUMULATOR PRESSURE LOW. MAINTENANCE SERVICED DOOR CYLINDER TO PROPER PRESSURE PER AMM 52-10-00.SDR AALA202001189007Striker · out of alignmentAIRCRAFT WAS GROUNDED: L2 DOOR WILL NOT LOCK OPEN. ACCOMPLISHED DETAILED VISUAL INSPECTION AND FOUND TEFLON BUSHING OUT OF PLACE AND STRIKERLEVER MISALIGNED. ADJUSTED STRIKER LEVER AND RE-INSTALLED TEFLON BUSHING PER AMM 52-13-12. ACCOMPLISHED SATISFACTORY OPESDR AALA202001179009Manifold · leakingAIRCRAFT WAS GROUNDED: CREW DECLARED AN EMERGENCY INTO PHL ACCOUNT YELLOW HYDRAULICS LOW QUANTITY INDICATION. FLIGHT LANDED WITHOUT INCIDENT AND TAXIED TO THE GATE. FOUND YELLOW HYDRAULIC SYSTEM POWER TRANSFER UNIT MANIFOLD LEAKING AND REPLACED IT PER AMM 29SDR AALA202001169004Engine · slowAIRCRAFT WAS GROUNDED: ROLLING TAKEOFF, ADVANCED THRUST LEVERS NR 2 WENT RIGHTUP TO 50 % NR 1 HAD A 2-3 SECOND DELAY. WE DISCONTINUED TAKEOFF. ON SECOND ATTEMPT WE DID A STATIC TAKEOFF. SAME RESULT. ONCE ENGINES STABILIZED THRUST WAS ADVANCED AND NO FURTHER LASDR ASAA2020021432178Seat Track · corrodedFWD WET AREA RH SEAT TRACK AT -Y1292 FR19 HAS CORROSION ON TOP FLANGE GROUNDED - YES. REMOVED CORROSION ORIGINAL THICKNESS .087, REMAINING MATERIAL .047, MATERIAL REMOVED .040 AND FOUND TO BE OUT OF LIMITS IAW A317 SRM 53-11-15, ACCOMPLISHED DOUBLER REPAIR IASDR ASAA2020013022014Support Frame · corrodedAFT WET AREA RH LATERAL SUPPORT FRAME AT FR69-FR70 HAS CORROSION ON LOWER SIDE GROUNDED - YES. REMOVED AND REPLACED FRAME SUPPORT IAW A319 SRM 51-42-11 REF AIRBUS DWG# D53474180. THIS IS A CATEGORY "A" REPAIR. (NO ALLOWABLE DAMAGE LIMITS GIVEN IN A319 SRM)SDR ASAA2020013022013Support Frame · corrodedAFT WET AREA LH LATERAL SUPPORT FRAME AT FR69-FR70 HAS CORROSION ON LOWER SIDE GROUNDED - YES. REMOVED AND REPLACED FRAME SUPPORT IAW A319 SRM 51-42-11 REF AIRBUS DWG D53474180. THIS IS A CATEGORY "A" REPAIR (NO ALLOWABLE DAMAGE LIMITS GIVEN IN A319 SRM)SDR WX0A2020011373458Cover · missingL1 DOOR FRAME LEFT LOWER SIDE EMERGENCY EXIT LIGHT COVER MISSING. INSTALLED LENS ON L1 DOOR FRAME LT LOWER SIDE IAW AMM 33-51-16-400-001-A OPS CHKS NORMAL.SDR ASAA2020002143177Shear Plate · corrodedAFT WET AREA L/H LATERAL SHEAR PLATE AT FR69-FR70 HAS CORROSION. GROUNDED - YES. NO CORROSION ALLOWABLE LIMITS GIVEN IN A319 SRM. REMOVED AND REPLACED L/H SHEAR PLATE AT FR69-FR70 IAW A319 SRM 51-42-11 AND AIRBUS DWG D53474180SDR ASAA2020012912009Floor Support · corrodedAFT CABIN WET AREA FLOOR STRUCTURE CORRODED 15 CM FORWARD OF C70 AND 110CM FROM RH SIDE GROUNDED - YES. REMOVED AND REPLACED FLOOR STRUCTURE FROM FR68 TO FR70 IAW A319 SRM 51-42-11. THIS IS A CATEGORY "A" REPAIR. (NO ALLOWABLE DAMAGE LIMITS GIVEN IN A319 SRSDR ASAA2020012912001Floor Support · corrodedAFT CABIN WET AREA FLOOR STRUCTURE CORRODED 15CM FWD OF C70, 78C GROUNDED - YES. FLOOR SUPPORT CORROSION PENETRATES COMPLETELY THUR STRUCTURE - OUT OF LIMITS - REMOVED EXSISTING FLOOR SUPPORT IAW A319 DWG 53472458 - RECIEVED NEW FLOOR SUPPORT P.N. D53472195SDR AALA2020011419006Connector · looseAIRCRAFT WAS GROUNDED: EMERGENCY EXIT LIGHT INOPERABLE AFT RIGHT ABOVE DOOR. MAINTENANCE RECONNECTED LOOSE CONNECTOR PER STANDARD PRACTICES AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA202001139004Regulator Valve · faultyAIRCRAFT WAS GROUNDED: AT 2000FT ON APPROACH PRESS SAFETY VALVE OPENED FOR APPROX. 2 MIN. REMOVED AND REPLACED 6HL SAFETY VALVE IAW AMM 21-31-52. OPS CHECKED GOOD.SDR AALA202001139040Regulator Valve · faultyAIRCRAFT WAS GROUNDED: AT 2000' ON APPROACH PRESS SAFETY VALVE OPENED FOR APPROX. 2 MIN. REMOVED AND REPLACED 7HL SAFETY VALVE IAW AMM 21-31-52. OPS CHECKED GOOD.SDR ASAA2020012902000Shear Plate · corrodedAFT CABIN FLOOR CLOSE OUT STRUCTURE AFT OF R2 DOR RBL120 HAS CORROSION IN MULTIPLE AREAS. GROUNDED - YES. REMOVED AND REPLACED SHEAR PLATE IAW A319 SRM 51-40-02 REF DWG D53480019. (NO ALLOWABLE DAMAGE LIMITS GIVEN IN A319 SRM). THIS IS A CATEGORY "A" REPAIR.SDR ASAA2020012903999Floor Support · corrodedMAIN CABIN FLOOR BEAM UNDER ACCESS PANEL # 231CF AT FR 21 IS CORRODED - DOT ATTACHED GROUNDED - YES. REMOVED CORROSION - ORIGINAL THICKNESS .063, REMAINING MATERIAL .038, REMOVED .025 AND FOUND TO BE OUT OF LIMITS IAW A319 SRM 53-11-14. REMOVED AND REPLACED SDR ASAA2020022092212Door Frame · corrodedDOOR R2 CUT OUT HAS SEVERAL AREAS OF CORROSION, MARKED GROUNDED - YES. REMOVED CORROSION - ORIGINAL THICKNESS .177, REMAINING .085, REMOVED .092 AND FOUND TO BE OUT OF LIMITS IAW A319 SRM 53-14-11. REMOVED AND REPLACED DOOR SILL P/N D5348004320701 IAW A
Back to Airbus A319-112