What was found
FWD WET AREA RH SEAT TRACK AT -Y1292 FR19 HAS CORROSION ON TOP FLANGE GROUNDED - YES. REMOVED CORROSION ORIGINAL THICKNESS .087, REMAINING MATERIAL .047, MATERIAL REMOVED .040 AND FOUND TO BE OUT OF LIMITS IAW A317 SRM 53-11-15, ACCOMPLISHED DOUBLER REPAIR IAW A319 SRM 53-11-15-300-005