SDR AALA202502102299Door Sill · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION LOWER SILL LH SIDE BTW FR66 AND FR68 AT AFT GALLET AREA, MEASURES OF CORROSION ARE L=4.144INCH, W=1.995INCH, W=0.028 INCH. MAINTENANCE REPLACED LOWER SILL LH SIDE BTW FR 66 AND FR 68 AT LEVEL STR 23L AT AFT GALLEY AREA IJan 3, 2025 · N753US · Airbus A319112 · Fuselage Miscellaneous StructureSDR AALA202502066665Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT RIGHT PASSENGER / CREW DOOR CUTOUT LOWER SILL CENTER SHAPE FITTING BETWEEN FR 66 AND FR 68 AT S23R. REPLACED CENTER SHAPE FITTING PER SRM 51-42-11.Jan 3, 2025 · N753US · Airbus A319112 · Fuselage Miscellaneous StructureSDR AALA202502040893Door Sill · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT RIGHT PASSENGER / CREW DOOR CUTOUT LOWER SILL BETWEEN FR 66 AND FR 68 AT S23R. REPLACED LOWER SILL PER SRM 51-42-11.Jan 3, 2025 · N753US · Airbus A319112 · Fuselage Miscellaneous StructureSDR AALA202502031218Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION CENTER FITTING AT LEVEL STR 23L BTW FR66 AND FR68 AT AFT GALLEY AREAL=1.916INCH W=0.620INCH D= 0.078INCH. MAINTENANCE REPLACED CENTER FITTING AT LEVEL STR23L BTW FR66 AND FR68 AT AFT GALLEY AREA IAW A319 SRM 51-42-11-801Jan 3, 2025 · N753US · Airbus A319112 · Fuselage Miscellaneous StructureSDR AALA202502039193Floorbeam · incorrectAIRCRAFT IN BASE MAINTENANCE: CORROSION FLOOR BEAM +Y254 FR 20 FWD GALLEY AREA MEASURES OF CORROSION ARE L=1.206INCH, W=0.682INCH, D=0.030INCH. MAINTENANCE REPLACED FLOOR BEAM Y254 FR 20 FWD GALLEY AREA IAW A319 SRM 51-42-11-801 AND DWG D53110900,DWG D53110984Jan 3, 2025 · N753US · Airbus A319112 · Fuselage Main, Floor BeamSDR AALA202501306699Seat Track · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION SEAT TRACK -Y1292 FR 20 AT FWD GALLEY AREA L= 0.323 IN W= 0.205 IN D= 0.015 IN. MAINTENANCEJan 3, 2025 · N753US · Airbus A319112 · Fuselage, Seat/Cargo Attach FittingsSDR AALA202501071451Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION ON FRAME 36 HORIZONTAL FLOOR BEAM AT ATTACHMENT AREA TO VERTICAL STRINGER 5, ZONE 2 AFT FACE VERTICAL RADIUS, CRACK LENGHT IS 0.270 IN. MAINTENANCE PERFORMED PERMANENT REPAIR ON FRAME 36 HORIZONTAL FLOOR BEAM AT AJan 3, 2025 · N749US · Airbus A319112 · Fuselage Main, Floor BeamSDR AALA202501075858Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION ON FRAME 36 FRONT SPAR VERTICAL STRINGER 1 OPEN FASTENER HOLE IN ZONE 1, CRACK DIRECTION IS 2 OCLOCK CRACK DEPTH IS 0.119 INCH APPROX IN FWD CARGO COMPARMENT. MAINTENANCE PERFORMED PERMANENT REPAIR ON FRAME 36 FROJan 3, 2025 · N749US · Airbus A319112 · Fuselage Main, Floor BeamSDR AALA202501076299Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION ON FRAME 36 HORIZONTAL FLOOR BEAM AT ATTACHMENT AREA TO VERTICAL STRINGER 3, ZONE 2 AFT FACE VERTICAL RADIUS, CRACK LENGTH IS 0.205 IN. MAINTENANCE PERFORMED PERMANENT REPAIR ON FRAME 36 HORIZONTAL FLOOR BEAM AT AJan 3, 2025 · N749US · Airbus A319112 · Fuselage Main, Floor BeamSDR AALA202501078581Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION ON FRAME 36 FRONT SPAR VERTICAL STRINGER 1 OPEN FASTENER HOLE IN ZONE 2, CRACK DIRECTION IS 12 OCLOCK CRACK DEPTH IS 0.110 INCH APPROX IN FWD CARGO COMPARMENT. MAINTENANCE PERFORMED PERMANENT REPAIR ON FRAME 36 FRJan 3, 2025 · N749US · Airbus A319112 · Fuselage Main, Floor BeamSDR AALA202501070089Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION ON FRAME 36 FRONT SPAR VERTICAL STRINGER 6 OPEN FASTENER HOLE IN ZONE 1, CRACK DIRECTION IS 12 O CLOCK CRACK LENGHT IS 0.115 IN. MAINTENANCE PERFORMED PERMANENT REPAIR ON FRAME 36 FRONT SPAR VERTICAL STRINGER 6 OPJan 3, 2025 · N749US · Airbus A319112 · Fuselage Main, Floor BeamSDR AALA202501071262Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION ON FRAME 36 HORIZONTAL FLOOR BEAM AT ATTACHMENT AREA TO VERTICAL STRINGER 4, ZONE 2 AFT FACE VERTICAL RADIUS. CRACK LENGHT IS 0.280 IN. MAINTENANCE PERFORMED PERMANENT REPAIR ON FRAME 36 HORIZONTAL FLOOR BEAM AT Jan 3, 2025 · N749US · Airbus A319112 · Fuselage Main, Floor BeamSDR AALA202501076356Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION ON FRAME 36 HORIZONTAL FLOOR BEAM AT ATTCHMENT AREA TO VERTICAL STRINGER 2, ZONE 1 AFT FACE VERTICAL RADIUS CRACK LENGHT IS 0.210 IN. MAINTENANCE PERFORMED PERMANENT REPAIR ON FRAME 36 HORIZONTAL FLOOR BEAM AT ATTJan 3, 2025 · N749US · Airbus A319112 · Fuselage Main, Floor BeamSDR AALA202501072096Stiffener · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION ON FRAME 36 FRONT SPAR VERTICAL STRINGER 6 OPEN FASTENER HOLE IN ZONE 2, CRACK DIRECTION IS 12 O CLOCK, CRACK LENGHT IS 0.110 IN. MAINTENANCE PERFORMED PERMANENT REPAIR ON FRAME 36 FRONT SPAR VERTICAL STRINGER 6 OJan 3, 2025 · N749US · Airbus A319112 · Fuselage Miscellaneous StructureSDR AALA202501049917Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK ON SHEAR PLATE LOCATED BETWEEN FR 69 TO FR 70 AT LEVEL OF STRINGER 23 LH SIDE AFT PAX CABIN. CRACK LENGTH: 1.213 INCHES. MAINTENANCE REPLACED SHEAR PLATE LOCATED BETWEEN FR 69 TO FR 70 AT LEVEL OF STRINGER 23 LH SIDE AFT PAXJan 3, 2025 · N749US · Airbus A319112 · Fuselage Miscellaneous StructureSDR AALA202501048731Door · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION WAS FOUND IN HOLE 7 LOC AT FR16 DOUBLER JUGGLE AREA, LH SIDE, AT LEVEEL DOOR STOP 7. CONFIRM INDICATION USING BOROSCOPE VIEW IAW NTM 51-90-00. CRACK DEPTH: 0.110 INCHESJan 3, 2025 · N749US · Airbus A319112 · Passenger/Crew DoorsSDR AALA202502256790Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION ON OPEN FASTENER HOLE UPPER JUNTION WINDSHIELD LH SIDE POST ,CRACK MEASURE IS L=0.450 INCH. MAINTENANCE ACCOMPLISHED PERMANET REPAIR LOC. LH LATERAL WINDOW FRAME ON WINDSHIELD SIDE POST AT FR4 LOWER ATTACHMENT FORJan 2, 2025 · N773XF · Airbus A319112 · Fuselage Main, StructureSDR AALA202502259770Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: REPLACE RH SIDE WINDSHIELD BY COSTUMER REQUEST . MEASURE CRACK IS L=0.600. MAINTENANCE ACCOMPLISHED PERMANET REPAIR LATERAL WINDOW FRAME ON WINDSHIELD SIDE POST AT FR4 LOWER ATTACHMENT FOR HORIZONTAL STIFFENERS RH SIDE IAW EA #36Jan 2, 2025 · N773XF · Airbus A319112 · Fuselage Main, StructureSDR AALA202501046268Hinge Pin · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AILERON HING PIN 2 R/H WING (L:0.227 INCH,W:0.080INCH,D:0.002 INCH). MAINTENANCE REPLACED AILERON HING PIN 2 R/H WING.Jan 2, 2025 · N753US · Airbus A319112 · AileronsSDR AALA202501040784Hinge Pin · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AILERON HING PIN 3 R/H WING (L:0.027 INCH,W:0.022 INCH,D:0.004 INCH ).MAINTENANCE REPLACED AILERON HING PIN 3 R/H WING.Jan 2, 2025 · N753US · Airbus A319112 · Leading Edge DevicesSDR AALA202501047495Hinge Pin · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AILERON HINGE PIN 4 R/H WING (L:0.418 INCH, W:0.168 INCH, D:0.004 INCH). MAINTENACNE REPLACED HINGE PIN IAW AMM 27-14-41-400-001-A.Jan 2, 2025 · N753US · Airbus A319112 · Leading Edge DevicesSDR AALA202501045781Hinge Pin · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AILERON HING PIN 5 R/H WING (L:0.386 INCH, W: 0.068 INCH, D:0.002 INCH). MAINTENANCE REPLACED HING PIN 5 IAW AMM 27-14-*41-400-0001-A.Jan 2, 2025 · N753US · Airbus A319112 · AileronsSDR AALA202501048816Megaphone · inoperativeAIRCRAFT WAS NOT GROUNDED: AFT FA MEGAPHONE NOT WORKING. MAINTENANCE REPLACED AFT CABIN MEGAPHONE. REF AMM 25-29-00.Jan 2, 2025 · N721UW · Airbus A319112 · Emergency EquipmentSDR AALA202501025634Megaphone · inoperativeAIRCRAFT WAS NOT GROUNDED: AFT MEGAPHONE INOP. MAINTENANCE REPLACED AFT MEGAPHONE.Dec 31, 2024 · N758US · Airbus A319112 · Emergency EquipmentSDR AALA202501026688Sign · inoperativeAIRCRAFT WAS NOT GROUNDED: OVERWING EXIT EMERGENCY EXIT LIGHT INOPERATIVE ON LEFT SIDE. MAINTENANCE REPLACED OVER WING EXIT SIGN AND OPS CHECKED GOOD PER AMM 33-51-16.Dec 31, 2024 · N762US · Airbus A319112 · Emergency LightingSDR AALA202412306039Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: AFT RH DOOR ASSIST BOTTLE PRESSURE REQUIRES SERVICING. MAINTENANCE SERVICED AFT RH DOOR DAMPER PRESSURE PER AMM 52-10-00.Dec 30, 2024 · N701UW · Airbus A319112 · Emergency EquipmentSDR EE4Y2024123021478Skin Panel · burnedDURING ALLEGIANT TASK CARD A32X-ZL-200-02-1-001_P1-VISUAL-INSP-UF/027 , UPPER FUSELAGE AT FR 37 70MM BELOW STRINGER 03 RH EXTERNAL SKIN WITH LIGHTNING STRIKE WAS FOUND. REPAIRED FUSELAGE SKIN SECTION FROM FR36+445MM TO FR 37+91MM BETWEEN STRINGER 2 AND 4 RH IADec 30, 2024 · N305NV · Airbus A319112 · Fuselage Main, Plate/SkinSDR AALA202412307612Power Supply · inoperativeAIRCRAFT WAS NOT GROUNDED: OVER WING EMERGENCY LIGHTS EPSU LEFT, RIGHT AND AFT INOP. MAINTENANCE REPLACED EPSU BATTERY IAW AMM 33-51-38.Dec 29, 2024 · N748UW · Airbus A319112 · Emergency LightingSDR AALA202502255964Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION SPIGOT FITTING RECEPTACLE ON LH PYLON MEASURES OF CORROSION ARE L= 12.200INCH, W=1.300INCH, D=0.003INCH. MAINTENANCE REPLACED SPIGOT FITTING ON LH PYLON IAW AMM 54-51-41-000-001-A, A319 SRM 54-51-12-300-001 AND AMM 54-5Dec 27, 2024 · N773XF · Airbus A319112 · Nacelle/Pylon, Main FrameSDR AALA202503178586Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION FOUND ON FR36 VERTICAL STRINGER 2, ZONE 1 HOLE, CRACK DIRECTION AT 12 O CLOCK LOOKING AFT. D=0.180 IN APPROX. MAINTENANCE PERFORMED INTERIM (BUSHING REPAIR) LOC. ON FR 36 VERTICAL STRINGER 2, ZONE 1 AND FLOOR BEADec 26, 2024 · N753US · Airbus A319112 · Fuselage Main, Floor BeamSDR AALA202503178636Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION FOUND ON FR36 HORIZONTAL FLOOR BEAM 5,-Y765 ,ZONE 1 HOLE CRACK L= 0.180 INCH. MAINTENANCE PERFORMED PERMANENT REPAIR (REPLACED DAMAGE SECTION ) LOC AT THE HORIZONTAL FLOOR BEAM 5,-Y765, FRAME 36 IAW EA 360855 PDec 26, 2024 · N753US · Airbus A319112 · Fuselage Main, Floor BeamSDR AALA202503173423Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION FOUND ON FR36 VERTICAL STRINGER 2, ZONE 2 HOLE, CRACK DIRECTION AT 11 CLOCK LOOKING AFT. D=0.180 IN APPROX. MAINTENANCE PERFORMED INTERIM REPAIR (BUSHING REPAIR) LOC. ON FR 36 VERTICAL STRINGER 2, ZONE 2 AND FLOODec 26, 2024 · N753US · Airbus A319112 · Fuselage Main, Floor BeamSDR AALA202503177920Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION FOUND ON FR36 VERTICAL STRINGER 3, ZONE 1 HOLE, CRACK DIRECTION AT 1 CLOCK LOOKING AFT. D=0.180 IN APPROX. MAINTENANCE PERFORMED INTERIM REPAIR (REPAIR BUSHING) LOC. ON FR 36 VERTICAL STRINGER 3, ZONE 1 AND FLOOR Dec 26, 2024 · N753US · Airbus A319112 · Fuselage Main, Floor BeamSDR AALA202503174060Beam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION FOUND ON FR36 VERTICAL STRINGER 3, ZONE 2 HOLE, CRACK DIRECTION AT 11 AND 9 O CLOCK LOOKING AFT. D=0.180 IN APPROX. MAINTENANCE PERFORMED INTERIM REPAIR (REPAIR BUSHING) LOC. ON FR 36 VERTICAL STRINGER 3, ZONE 2 Dec 26, 2024 · N753US · Airbus A319112 · Fuselage Main, StructureSDR AALA202503174075Beam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION FOUND ON FR36 VERTICAL STRINGER 4, ZONE 1 HOLE, CRACK DIRECTION AT 1 AND 3 O CLOCK LOOKING AFT. D=0.180 IN APPROX. MAINTENANCE PERFORMED INTERIM REPAIR (BUSHING REPAIR) LOC. ON FR 36 VERTICAL STRINGER 4, ZONE 1 Dec 26, 2024 · N753US · Airbus A319112 · Fuselage Main, StructureSDR AALA202503170412Beam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION FOUND ON FR36 VERTICAL STRINGER 4, ZONE 2 HOLE, CRACK DIRECTION AT 11 AND 7 O CLOCK LOOKING AFT. D=0.180 IN APPROX. MAINTENANCE PERFORMED INTERIM REPAIR (BUSHING REPAIR) LOC. ON FR 36 VERTICAL STRINGER 4, ZONE 2 ADec 26, 2024 · N753US · Airbus A319112 · Fuselage Main, StructureSDR AALA202503174574Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION FOUND UPPER RADIUS OF WINDSHIELD CENTER POST LOWER ATTACHMENT AREA RH SIDE. MEASURE OF CRACK= 0.170 INCH. MAINTENANCE PERFORMED TIME LIMIT REPAIR (REPLACED CENTER WINDSHIELD FRAME POST) LOC BTW FR2 TO FR 4 AT LEVEDec 23, 2024 · N753US · Airbus A319112 · Fuselage Main, StructureSDR AALA202503176486Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION FOUND ON UPPER RADIUS OF WINDSHIELD CENTER POST LOWER ATTACHMENT AREA LH SIDE CRACK L=0105. MAINTENANCE PERFORMED TIME LIMITED REPAIR (REPLACED CENTER WINDSHIELD FRAME POST) IAW EA 360716.Dec 23, 2024 · N753US · Airbus A319112 · Fuselage Main, StructureSDR AALA202503171123Attach Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION FOUND ON FASTENER HOLE LOCATED AT Y1294 OF PRESSURE DECK MEMBRANE FR 36. CRACK DIRECTION 6 OCLOCK VIEW LOOKING AFT AND UP. CRACK D=0.120 INCH. MAINTENANCE PERFORMED PERMANENT REPAIR (EXTERNAL DOUBLER ) LOC.ON PRESDec 23, 2024 · N753US · Airbus A319112 · Fuselage Main, Attach FittingsSDR AALA202502258786Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION FITTING BORE OF PYLON SPIGOT RECEPTACLE IN RH PYLON MEASURES OF CORROSION ARE L=12.00INCH, W=1.27INCH, D=0.003INCH. MAINTENANCE REPLACED SPIGOT FITTING ON RH PYLON IAW AMM 54-51-41-000-001-A, A319 SRM 54-51-12-300-001 ANDec 23, 2024 · N773XF · Airbus A319112 · Nacelle/Pylon, Main FrameSDR AALA202501283470Bracket · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON RH MLG RETRACTION ACTUATOR ATTACHMENT BRACKET UPPER FACE. MEASURES ARE L= 1.000 IN W= 0.500 IN D= 0.0098 IN. MAINTENANCE REWORKED BORE FASTENER HOLE.Dec 23, 2024 · N773XF · Airbus A319112 · Main Landing GearSDR AALA202502104383Damper · no testAIRCRAFT IN BASE MAINTENANCE: DONT PASS OPERATIONAL TEST DAMPING FUNCTION ON PASSENGER CREW DOOR 832 AT AFT GALLEY AREA. MAINTENANCE REPLACED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PASSENGERCREW DOOR 832 IAW AMM 52-13-14-000-001-B AMM 52-13-14-400-001-B.Dec 22, 2024 · N753US · Airbus A319112 · Passenger/Crew DoorsSDR AALA202502100980Bottle · no testAIRCRAFT IN BASE MAINTENANCE: DONT PASS OPERATIONAL TEST DAMPING FUNCTION ON PASSENGER CREW DOOR 842 AT AFT GALLEY AREA. MAINTENANCE REPLACED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PASSENGERCREW DOOR 842 AT AFT GALLEY AREA IAW AMM 52-13-14-000-001-B, AMDec 22, 2024 · N753US · Airbus A319112 · Passenger/Crew DoorsSDR AALA202502257797Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: REPLACE CONTINUITY FITTING RH SIDE CENTER POST WINDSHIELD COCKPIT IAW EA 360366. MAINTENANCE REPLACE CONTINUITY FITTING RH SIDE CENTER POST WINDSHIELD COCKPIT IAW EA 360366.Dec 21, 2024 · N773XF · Airbus A319112 · Fuselage Main, StructureSDR AALA202502251473Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: REPLACE CONTINUITY FITTING LH SIDE CENTER POST WINDSHIELD COCKPIT IAW EA 360366. MAINTENANCE REPLACED YO CONTINUITY FITTING LH LOC. BTW FR1 TO FR2 AT CENTER WINDSHIELD IAW EA360366.Dec 21, 2024 · N773XF · Airbus A319112 · Fuselage Main, StructureSDR WX0A2024122332242Lens · broken(AIRCRAFT NOT GROUNDED) WALL MOUNTED EXIT SIGN LENSE COVER BROKEN @ ROW 14DEF / REPLACED ROW 14DEF EXIT SIGN LENSE COVER REF AMM 33-51-13-400-001-A. A/C OK FOR SERVICE. THIS CLEARS M313 204686"Dec 21, 2024 · N302NV · Airbus A319112 · Emergency LightingSDR AALA202412234823Damper · no testAIRCRAFT IN BASE MAINTENANCE: DONT PASS TEST DAMPING FUNCTION ON DOOR DAMPER AND EMERGENCY OPERATIONCYLINDER IN PASSENGER CREW DOOR 831. MAINTENANCE REPLACED DOOR DAMPER ONPASSENGER CREW DOOR 831 AT FWD GALLEY AREAI.A.W AMM 52-11-14-000-001-B AND AMM 52-11-14Dec 21, 2024 · N749US · Airbus A319112 · Passenger/Crew DoorsSDR AALA202412232675Contact · brokenAIRCRAFT WAS NOT GROUNDED: SEAT MOUNTED EMERGENCY PATH LIGHTING AT 22C & 23C INOP LIGHT ASSEMBLY REPLACED IAW AMM 33-51-19 NO HELP. MAINTENANCE FOUND BROKEN WIRE AT CONNECTOR 7260VC AT SEAT ROW 22C AND REPAIRED WIRE INSTALLING NEW CONTACT IAW ESPM 20-44-10, ASDec 21, 2024 · N723UW · Airbus A319112 · Light System WiringSDR AALA202412231441Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: FWD R/H ENTRY DOOR CYLINDER /ACCUMULATOR PRESS LOW 1250 PSI AT80 DEGREE. MAINTENANCE SERVICED R-1 DOOR ACCUMULATOR IAW AMM 52-10-00.Dec 20, 2024 · N723UW · Airbus A319112 · Passenger/Crew DoorsSDR AALA202412233790Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: AFT R/H ENTRY DOOR CYLINDER /ACCUMULATOR PRESS LOW 1250 AT 80 DEGREE. MAINTENANCE SERVICED RIGHT AFT. DOOR ACCUMULATOR IAW AMM 52-10-00.Dec 20, 2024 · N723UW · Airbus A319112 · Passenger/Crew Doors
Back to Airbus A319-112