What was found
AIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION ON FRAME 36 HORIZONTAL FLOOR BEAM AT ATTACHMENT AREA TO VERTICAL STRINGER 3, ZONE 2 AFT FACE VERTICAL RADIUS, CRACK LENGTH IS 0.205 IN. MAINTENANCE PERFORMED PERMANENT REPAIR ON FRAME 36 HORIZONTAL FLOOR BEAM AT ATTACHMENT AREA TO VERTICAL STRINGER 3, ZONE 2 AFT FACE VERTICAL RADIUS IAW EA 358700.