SDR CALA2023011800145Electrical Box · missingPDA 3 NLG TOWING BOX LEVER MISSING BOTH SPRING CLIPS.. SEE PHOTO.. PHOTO ADDED THREADS WORN FOR BOLT -- NEED NEW ELEC BOX PARTS USED: 31-3252-9-9001,QTY :1 REPLACED AND TESTED NLG ELECT BOX REF 32-51-12.SDR CALA2023011800141Fitting · damagedRH MLG DOOR ACT FITTING REPAIRED AREA. CREATE DIP FOR PLANNING PURPOSES ONLY. 32,170 TOTAL ACFT FC BUT BEFORE 32,200 TOTAL ACFT FC FOR THE NR 9294007. ECRA 5330-07042 PART 3 PERM RPR INSTRUCTIONS. WRK ACMP ON HAECO IAW ECRA 5330-07042 PART 1.3. AT THE RPAIREDSDR CALA2023011800140Fitting · damagedRIGHT MLG DOOR AFT ACT FITTING RPR, FOR THE ECRA 5330-07043 PART 3 PERM RPR INSTRUCTIONS. IAW ECRA 5330-07043 PART 1.3. REF LP 3596240 DIP CREATED AT THE RPR AREA OF THE RH MLG DOOR ACT FITTING, PLANNING TO CONTACT EG AFTER 15NOV2023 BUT BEFORE CARRY APPROVED SDR 2023FA0000031Seal · crackedNR 2 ENGINE STAGE 6 TURBINE INNER AIR SEAL CRACKED, IAW VRS4018, HAS BEEN FOUND IN THE FPI PROCESS. LIFE LIMITED PART TO BE RETIRED WITH 8577 CYCLES REMAINING (LLP LIMIT IS 20000 CYCLES)SDR CALA2023011100091Pressure Switch · reads lowHYD B SYS LO PR REMOVED AND REPLACED THE BLUE SYSTEM PRESSURE SWITCH. PERFORMED OPERATIONAL CHECK AND LEAK CHECK OF BLUE HYD SYSTEM PRESSURE SWITCH.OPS CHECK GOOD.SDR CALA2023010900050Proximity Sensor · faultedDOOR R EMER EXITECAM DISPLAYED SHORTLEY AFTER TAKE OFF REQUESTING MEL 5270BK. INSPECTED AREA, DOOR CONFIRMED LOCKED, PLACED ON MEL 5270BK SECURED AND FOOR ARMED SUSPECT COVER PLATE MAY NEED ADJUSTMENT. INSPECTED AREA, DOOR CONFIRMED LOCKED. ADJUSTED COVER PSDR 2023FA0000022Shaft · damagedHPC REAR SHAFT,GALLING LOC.2 IAW SUBTASK 72-41-13-220-189 NOT PERMITTED. LLP TO BE RETIRED WITH 12843 CYCLES SINCE NEW (LIFE LIMIT WAS 20000 CYCLES)SDR CALA2022123003526Door · missingPDA 1 POTABLE WATER SERVICE DOOR FOUND MISSING FROM ACFT UPON ARRIVAL IN DFW POTABLE WATER SERVICE DOOR WAS PREVIOUSLY ON PLACARD (CDL 52C) FOR A BROKEN HINGE. REFERENCE LOGPAGE 3406076. REFER TO LOGPAGE 3406076 FOR UPDATES AND MAINTENANCE ACTION(S). THIS LOGPSDR CALA2022123003535Shear Tie · crackedFR43 FOOT RT FOUND CRACK INDICATION (EA5330-066902 REV B) SEQ# 737, LTPR NR# 005001203475-0010.SDR CALA2022123003534Shear Tie · crackedFR43 FOOT RH FOUND CRACK INDICATION (EA5330-066902 REV B) SEQ# 737, LTPR NR# 005001203475-0010.SDR CALA2022122603493Anti-Ice Valve · faultedWING A.ICE SYS FAULT DISPLAYED ON ECAM. BOTH L&R WAI VALVES IN THE CLOSED POSITION L&R WAI VALVES IN THE CLOSED POSITION. ACCOMPLISHED WAI TEST USING ENGINE AIR TEST PASS. INDICATIONS NORMAL, CYCLED CBS C1/C2/F1/Q7 FAULT MESSAGES CLEAR.SDR 2022FA0000774Turbine Wheel · crackedCRACKED IN AREA A1 OVER REPAIR VRS4018 LIMITS (SUBTASK 72-50-00-230-071). MINIMUM REMAINING KNIFE EDGE HEIGHT LESS THAN 0.0177 IN. (0.45 MM) (SUBTASK 72-50-00-350-061). NON REPAIRABLE. LIFE LIMITED PART TO BE SCRAPPED WITH 12843 CYCLES (LIFE LIMIT 20000 CYCLESSDR CALA2022120203270Power Supply · failedCABIN EMERGENCY LIGHTS OPERATIONAL CHECK: {A3NB-33-3-6012} - FAILED TEST MSG EPSU INT LOAD EMER R CABIN EMEGENCY EXIT POWER SUPPLY WAS BORROWED FROM AMERICAN AIRLINES JFK. PN 3214-54-10, SN 010004, RH POSITION. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1553584SDR CALA2022113003245Shear Panel · corrodedAFT CABIN SHEAR PLATE LH SIDE IS CORRODED. PER HAECO LCQ NON-ROU TINE 9294440/44440. REMOVED AND REPLACED NEW SHEAR PLATE ON AFT CABIN L/H SIDE FR69 TO FR70 IAW SRM 51-72-11-911-001 AND TOP COATED FASTENERS I AW A319 SRM 51-23-11-001.SDR CALA2022112803243Oxygen Mask · leakingCREW SYSTEM LOW CREW OXYGEN SYSTEM-LOW... RECORD PRESSURE PRIOR TO SERVICING 820PSI AFTER TAKEOFF PRESSURE WAS 870 ON GROUND MARTIN, ERIC (V907926) TROUBLESHOT PER TSM 35-10-00-810-813A. FO UND LARGE LEAK COMING FROM LH OBSERVERS MASK. REMOVED OBSERVER MASK ANSDR CALA2022112503214Cover Plate · corrodedCORROSION ON TORSION BOX COVER SHEET. AS NOTED ON LTPR NR# 5001183828-0010. PERFORMED REPLACEMENT OF TORSION BOX COVER SHEET PER SRM 51-72-11-911-001 REV.142.SDR CALA2022112503213Threshold · corrodedCORROSION ON AFT CARGO DOOR THRESHOLD SHEET.AS NOTED ON LTPR NR# 5001183828-0010. PERFORMED REPLACEMENT OF THRESHOLD SHEET AS PER SRM 51-72-11-911 -001 REV.142.SDR CALA2022112303196Idg · faultedGEN 1 INDICATIONS INOP ON ELEC SYSTEM ECAM PAGE AT GEAR RETRACTIONLOST GEN 1. FLIGHT CREW ACCOMPLISHED DISCONNECTION OF NR 1 IDG, 24-21-43-210-048C1 IAW AD 2011-19-01 R1. PERFORMED AUTOMATIC GALLEY SHEDDING TEST IAW AMM 24-27-00. VERIFIED APU OIL LEVEL OK ,SDR CALA2022112303205Battery · no testEPSU BATTERY (11WL) FAILED ON EMERGENCY LIGHTING BATTERY CAPACITY. BATTERY REPLACED (11WL) IAW AMM 33-51-38-000-002 & 33-51-38-400-002 REV 117. TESTED SATISFACTORY.SDR CALA2022112303204Battery · no testEPSU BATTERY (13WL) FAILED ON EMERGENCY LIGHTING BATTERY CAPACITY TEST. BATTERY REPLACED IAW AMM:33-51-38-000-002/ 33-51-38-400-002 REV 117. TESTED SATISFACTORY.SDR CALA2022112303203Battery · no testEPSU BATTERY (12WL) FAILED ON EMERGENCY LIGHTING BATTERY CAPACITY TEST . BATTERY REPLACED. PERFORMED IAW AMM:33-51-38-000-002/33-51-38-400-002 REV. 117. TESTED SATISFACTORY.SDR CALA2022112303202Battery · no testEPSU BATTERY (10WL) FAILED ON EMERGENCY LIGHTING BATTERY CAPACITY TEST. AS NOTED ON LTPR NR TASK CARD# 5001184853-0010. EPSU BATTERY (10WL) FAILED ON EMERGENCY LIGHTING BATTERY. CAPACITY TEST AND REQUIRE REPLACEMENT. BATTERY REPLACED (10WL). PERFORMED IAW ASDR CALA2022112103193Harness · failedENG 2 EGT OVERTEMP ONT/O ROLL.TEMP APROX 890C 77-20-00-810-802-B. TOMC-MEREDITH UPDATED MAA CODE FIX USING VENDOR MAA SCREEN CREW REPORTED LOW SPEED ABORTED TAKEOFF AND EGT INDICATION POST FLIGHT REPORTS. SEE ATTACHED PICTURES. PLEASE CONTACT TOMC BEFORE COMMESDR CALA2022111703158Skin · gougedGOUGE FOUND ON RH FWD AVIONICS DOOR SKIN. AS NOTED ON LTPR NR# 5001180871-0010. REPAIRED FWD RH AVIONIC DOOR IAW SRM 52-41-00-300-001. THIS IS A CAT "A" RPR WITH NO ADDITIONAL INSP REQUIREMENTS. BY LHT TECH 5T1195 AND INSP 5H0619.SDR CALA2022111703171Fuel Cap · missingRIGHT WING REFUEL CAP MISSING REFUEL/DEFUEL COUPLING CAP MISSING NO LEAKS NOTED FUEL CAP. INSTALLED FUEL CAP. FOUND MISSING FUEL CAP.
.SDR CALA2022111703170Fuel Cap · missingMISSING FUEL CAP RIGHT WING NO VISIBLE OR REPORTED FUEL LEAK. NO LEAKS OR DAMAGE. INSTALLED MISSING FUEL CAP.SDR CALA2022111703157Door Sill · corrodedCORROSION ON DOOR SILL AT FR68 R/H. AS NOTED ON LTPR NR# 5001182875-0010. REPLCAED D2R DOOR SILL IAW SRM 53-41-14-80-A. BY LHT TECH 5H0883 & INSP 5H 0619.SDR CALA2022111603138Line · leakingECAM CAUTION MESSAGE - Y ENG PUMP LO PR MESSAGE INOP - HYD UPON ARRIVAL TO FLT DECK, FOUND YELLOW HYD QTY AT ZERO. R&R #2 ENGINE HYDRAULIC LINE PART #D2901010201200 , REF IPC IDENTIFIED HYDRAULIC FLUID BENEATH #2 ENGINE. FOUND HYD PIPE 29-13-06-02L ITEM #260. SDR CALA2022111603139Skin · gougedPREVIOUS REWORK WITH DEEP GOUGE 2EA. AFTER PAINT REMOVAL ON FUSELAGE SKIN BTW FR. 22-23 STGR.42LH-43LH, REFERENCE TO D/O 5001188947-0010. LTPR NR# 5001189575-0010. REV. 142.PERFORMED LOCAL FABRICATION OF REPAIR DOUBLER AS PER INSPECTION INTERVALS OF TBD. REF. SDR CALA2022111403124Skin · damagedFUSELAGE SKIN AT FR34 FROM STR 43L TO 43R HAS ELONGATED HOLES. PERMANENT REPAIR PER PER 3 OF THE LATEST REVISION OF EC/RA 5321-02087 ON OR BEFORE 11MAY23. ITERIM REPAIR ACCOMPLISHED AT VT-MAE DURING HMV CHECK. REPAIR IS A PERMANENT SOLUTION WITH INSPECTION REQSDR CALA2022111103121Skin · crackedCTR FUSELAGE FR35 LH STR 30 HOLE #2 CRACKED (FRAME FLANGE AND AFT SKIN) AND AFT SKIN OF LH FR35 STR30 PER PART2, STEP1 OF THE LATEST REV ULATES 39562 TOTAL FLIGHT CYLES OR 86743 TOTAL FLIGHT HOURS. THE COMES FIRST. ISION OF THE EC/RA 5321-02084, ON OR BEFORE ASDR CALA2022111103117Skin · crackedSUPPORT TASK: SURVERYED THE FASTENERS AT LH FR35, BETWEEN STRG 2 8 AND STRG 31, A PREVIOUS REPAIR IS SUSPECTED AS FASTENERS ARE A BOVE NOMINAL SIZE. FR35 STR30 LH HAS 3 CRACK INDICATIONS IN HOLE #2 IN FWD SKIN AND AFT SKIN LAYER @3 AND 9 OCLOCK AS SEEN FROM OUSDR CALA2022110703074Fastener · missingMISSING FASTENERS, INSTALLED NEW FASTENERS.SDR CALA2022110703052Door Sill · corrodedR2 DOOR SILL IS CORRODED. R & R R2 DOOR SILL IAW SRM 51-42-11 AND 51-72-11.SDR CALA2022110403033Warning Message · false activationMAINTENANCE STATUS MESSAGE ENG 1 FADEC DISPLAYED ON THE LOWER EC AM SCREEN . NO MESSAGE SHOWN. ENG 1 FADEC CHANNEL A AND B TESTS PASSED.SDR CALA2022110203019Warning Message · false activation*EMERGENCY DECLARED* F/CTL FLAPS LOCKED ECAM MESSAGE. CORELATED FAULT MESSAGES: FLP 2 CHK RH MECH DRIVE AND FLP 1 CHK RH MECH DRIVE CREW REPORTED TE FLAPS LOCKED WHEN FLAPS LEVER WAS MOVED FROM 1 TO 2 THEN BACK TO 1 BEFORE FLAPS FULLY REACHING 2. TSM 27-51-00SDR CALA2022103102993Actuator · fault messageCOMPRESSOR VANE DISPLAYED ON UPPER ECAM SCREEN. - ENG ENG 1 ON INITIAL TO ROLL PERFORMED FADEC 1A&B BITE AND FOUND CHA AND CHB VSV ACT/HC/EEC1 REMOVED #1 ENG VSV ACTUATOR AS PER AMM 75-32-41-000-010-A. INSTALLED VSV ACTUATOR PER AMM 75-32-41-400-010..NEED TO PSDR CALA2022102802978Cleat · corrodedFWD CARGO PIT R/H FR27 BETWEEN STRINGERS 41R-42R HAS CORROSION A T CLEAT DOT M093. PER HAECO LCQ NON-ROUTINE 9294244/44244 GENERA TED BY V919150. SPEC: A3NB-53-3-6105. REMOVED AND REPLACED CLEAT FWD CARGO R/H FR27 BETWEEN STRINGERS 41R-42R P/N 5323052620017 P.SDR CALA2022102702960Flange · crackedSUPPORT TASK: FRAME 68 STR 22 RH FLANGE HAS CRACK ABOVE DOOR STO P BOLT #3 PER HAECO LCQ NON-ROUTINE 9294158/44158 GENERATED BY V 892444SDR CALA2022102702959Cleat · corrodedFWD CARGO PIT R/H FR27 BETWEEN STRINGER 42R-43R HAS CORROSION AT CLEAT (A3NB-53-3-6105) GENERATED BY V919150 AT HAECO LCQ PER NR 9294246 (44246) REMOVED AND REPLACED CLEAT FWD CARGO PIT R/H FR27 BETWEEN STRING ERS 42R-43R WITH P/N 5323039820101 IAW A319 SRM 51SDR CALA2022102702955Fitting · crackedFRAME 68 STR 22 LH HAS CRACK IND. IN FLANGE AT RADIUS ABOVE DOOR STOP BOLT #3 PER HAECO LCQ NON ROUTINE 9294160/44160 GENERATED BY V892444SDR CALA2022102402930None · missingPDA 3 FOUND ON WALK AROUND: #1 ENGINE COMMON EXHAUST NOZZLE APPOX 1 O''CLOCK IS MISSING METAL. SEE PICS ADDED PICS ADD PIC REMOVED NUMBER 1 ENG COMMON NOZZLE ASSEMBLY REF AMM 71-11-11-00-010A. REMOVED AND REPLACED CNA ASSY REF AMM 78-11-11 ALL CHECKS GOOD AT TSDR CALA2022102402926Fitting · crackedFLIGHT DECK WINDSHIELD CONTINUITY FITTINGS LH AND RH HAVE CRACK INDICATIONS "CONTACT ENGINEERING FOR REPAIR INSTRCUTIONS BEFORE NEXT FLIGHT" GENERATED AT HAECO LCQ PER NR 9294615 (44615) BY V8 92444 SUPPORT TASK ACCOMPLISHED A CATEGORY A PERMANENT REPAIR ON THSDR CALA2022102402916Door Sill · corrodedL2 DOOR SILL PLATE IS CORRODED. PER HAECO LCQ NON-ROUTINE 929444 1/44441 GENERATED BY V892442 SPEC: A3NB-53-3-6357. REPAIRED (2) DOOR SILL PLATE AT FR68 IAW A319 SRM 53-41-14-300-0 01 FIGURE 001 REPAIRED TOPCOAT IAW SRM 51-75-12-911-002 PERFORME D V928628 INSPSDR CALA2022101402819Fuel Cap · missingFUEL CAP MISSING REPORTED BY RAMP ACP MEL REQUIREMENTS. INSTALLED SERVICABLE FUEL CAP AND LANYARD.SDR CALA2022101202793Frame · crackedLH EMERGENCY EXIT LH FRAME HAS EVIDENCE OF CRACK PER NR9294643/4 4643 GEN BY V935513 RMVD DAMAGED SEGMENT/FRAME ON LH SIDE OF LH EMERGENCY EXIT AND R EPLACED WITH A NEW FRAME IAW SRM 51-72-11-911-001 BY MECH V07484 6 INSP BY V061334SDR CALA2022101002754Frame · crackedRH EMERGENCY EXIT LH AND RH FRAME HAS EVIDENCE OF CRACK. PER HAE CO LCQ NR 9294644/ 44644 REMOVED DAMAGED RH & LH FRAMES & REPLACED WITH NEW FRAMES IAW A3 19 SRM 51-72-11-911-001 & 002SDR CALA2022100302655Filter · odorDURING CRUISE HAD STRONG ODORS IN FLT DECK ANDGALLEY. FOUND NO EVIDENCE OF ODOR. PERFORMED TSM 05-50-00-810-831-A . PERFORMED OPS CHECK OF BOTH PACKS. FOUND #1 PACK TO BE CAUSING ODOR. FOUND #1 PACK TO BE CAUSING ODOR. PERFORMED VISUAL REPLACED RECIRCULATION SDR CALA2022100302654Safety Valve · failedLANDING GEAR DID NOTEXTEND NORMALLY.PERFORMED MANUALEXTENSION TROUBLESHOT L/G AND DOORS REF AMM 32-31-00-810-808-A. FOUND OPS CHECK NORMAL. SAFETY VALVE 49GA FAILED. REPLACED SAFETY VALVE. ACCOMPLISHED 6 GEAR SWING CYCLES AND PERFORMED OPS CHECK OF SAFETY VALVSDR CALA2022100302611None · noneSPILL CLEANUP GENERAL PROCEDURES REQUIRED UNDER AFT GALLEY PER ECRA 2011-01000AB DUP TO LP 9617126 ACCOMPLISHED PAR. 2.A. IMMEDIATE CLEANUP. DIP PAR. 2.B. FOR 7 DIP PER EC 2011-01000 DAYS. OK TO DIP THE IN-DEPTH CLEAN FOR 7 DAYS REF ECRA 2011-01000. TOMC-APPRO