Airbus A319-131
Service difficulty reports · 5,795
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A319131' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A319131' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2017102303739Door Sill · corrodedUPON REMOVAL OF R2 AF BLANKING PLATE FOUND CORROSION PRESENT ON DOOR SILL AND AFT CORNER FITTING. REMOVED AND REPLACED R2 DOOR SILL AND AFT CORNER FITTING IAW SRM 51-72-11-911-001 / 51-42-11-001.SDR CALA2017121104397Support Bracket · damagedEXIT LIGHT ROW 21DEF INOP REPLACED EMER SIDE WALL LIGHT SUPPORT BRACKET FOR LIGHT(90WL4)AT SEAT ROW 21DEF,OPS NORMAL. INSP INSTALLATION OF EMERGENCY LIGHTING OP CK OKSDR CALA2017121104389Fan · odorFAINT ODOR IN COCKPIT DURING CLIMB OUT. REMOVED AND REPLACED FAN BLOWER IAW AMM 21-26-51 . OPS CHECK OK.NO LEAKS NOTEDSDR CALA2017120804364Cover · looseDOOR L EMER EXIT DISPLAYED ON UPPER ECAM SCREEN L OVRWNG EXIT DO OR INDICATING OPEN ON LWR ECAM FOUND DOOR SLIDE COVER OFF ,INSTALLED COVERSDR CALA2017120804366Unknown · unknownEMERGENCY EXIT LIGHTS ON WITH FLT DECK SWITCH IN THE ARM POSITION CYCLED POWER AND EMER. EXIT LT. SWITCH . EMER. LIGHTS FUNCTION NORMALLYSDR CALA2017120804365Cover · looseLEFT OVER WING EMERG EXIT COVER CAME OFF SHOWED DOOR OPEN ONE ECAM ON LNDG INSTALLED COVERSDR CALA2017120304301Director · malfunctionedEMERG EXIT LIGHTS ON. RESEAT CIDS DIRECTOR SYST OP OKSDR CALA2017120104282Light · malfunctionedOVERHEAD EMERGENCY LIGHTS IN CABIN STUCK ON. UNDER TOMC GUIDANCE, CREW CYC H5, H6, H7 AND V7. LIGHTS REMAINED ON. CYC NO SMOKING SWITCH, LIGHTS WENT OUT.SDR CALA2017120104281Cover · looseDOOR L EMER EXIT ECAM ON TOUCHDOWN RESECURED COVER FLAP AS REQUIRED IAW TSM 52-21-00. EXTINGUSHED ECAM MESSAGE.SDR CALA2017120104248Door Sill · corrodedSUPPORT TASK - UPON REMOVAL OF FLOOR PANEL IN AFT CARGO PIT FOUND CORROSION ON DOOR SILL IB COVER SHEET R&R COVER SHEET IN AFT CARGO PIT FR56-59RT, P/N: D5347715400, PO :1039704.1 IAW A319 SRM 51-42-11.SDR CALA2017120104244Skin · dentedDENT ON EXTERIOR FUSELAGE SKIN LH SIDE AT FRAME 11 JUST ABOVE STRINGER R23. REPAIRED DENT ON EXTERIOR FUSELAGE SKIN LH SIDE AFT OF FRAME 11 ABOVE STGR 23 REF SRM 53-00-11-300-029. INSPECTION THRESHOLD FRO M TIME OF REPAIR EMBODIMENT IS 60,000 FLT CYCLES OR 12SDR CALA2017120104239Skin · noneREF EA 2300-01842 OP-0 ACCOMPLISH DOUBLER REPAIR AT ANTENNA FR 63-64 STR 41L-STR 42L. ACCOMPLISHED REPAIR DOUBLER AT AIRPHONE ANTENNA FR 63-64 STR 41L -STR 42L REFERENCE SRM 53-00-11-300-029. FUTURE INSPECTION THRES HOLD FROM TIME OF REPAIR EMBODIMENT IS 56,50SDR CALA2017112704232Structure · corrodedR2 FWD INBD DOOR SILL GIRT BAR ATTACHMENT AREA FOUND TO BE CORRODED. BLENDED CORROSION AND FOUND OUT OF LIMITS IAW SRM 53-41-14-283-002. PERFORMED A REPAIR, PRINCIPLES 1 AND 9 IAW SRM 53-41-14 -300-001, SHEETS 2, AND 5.SDR CALA2017112604225Power Supply · malfunctionedCIDS EMERGENCY LIGHT TEST FAILED. MESSAGE "EPSU BATTERY EMER R" 33-35-38 RESET EMERGENCY POWER SUPPLY 12WL. OP CK NORMAL. REF AMM 33-51-00-710-001.SDR CALA2017112604218Altimeter · faultySTANDBY ALTIMETER INDICATION ERRONEOUS. REMOVED AND REPLACED STANDBY ALTIMETER PER AMM 34-21-22. OPS CHECK GOOD.SDR CALA2017112404203Battery · faultyCIDS EMERGENCY SYSTEM FAILED THE 2 SERVICE CHECK, BATTERY FAILED FWD LT AND EPSU EMERGENCY L AND EPSU EMER R. REPLACED EPSU BATTERIES AT (10WL), (11WL), AND (12WL) PER MM33- 51-38-400-002, OPS CHECKS GOOD.SDR CALA2017112204190Sign · missingEMERGENCY EXIT SIGN MISSING. REPLACED THE SIGN ASSY. OPS CHECKED GOOD IAW AMM 33-00-00.SDR CALA2017111804141Cable · brokenR2 DOOR SLIDE SOFT COVER RELEASE CABLE SAFETY BROKEN. INSTALLED A SLIDE.SDR CALA2017111704125Slide · contaminatedLEFT OVERWING SLIDE HAD EXCESSIVE MOISTURE INGRESS. REMOVED AND INSTALLED THE SLIDE.SDR CALA2017111704100Unknown · odorF/A REPORTED A STRONG ACRID ELECTRICAL ODOR IN THE AFT GALLEY. DISSIPATED BEFORE FA PULLED CIRCUIT BREAKERS. ACCOMPLISHED A SMOKE OR FUMES IN CABIN INSPECTION. CHECKED IAW AMM 05-51-10. NO DEFECTS NOTED IN AFT CABIN GALLEY. ALL CIRCUIT BREAKERS RESET ALLSDR CALA2017111704098Light · malfunctionedEMERGENCY LIGHT FAILED DURING AN A-10 CHECK IAW 33-51- 38. SIDS PANEL BATTERY TEST PUSHBUTTON ON PTP FAILED. ALL EMERGENCY LIGHTS IN CABIN CHECKED WITH FLIGHT DECK SWITCH & AFT FLIGHT ATTENDANT PANEL. RESET BREAKERS SYSTEM CHECKED GOOD.SDR CALA2017111704096Skin · gougedSKIN FRAMES 13 - 14, STRINGERS 22 - 23L GOUGED OUT OF LIMITS, FABRICATED AND INSTALLED A DOUBLER IAW SRM 53-00-11-300-042, FIG 20148.SDR CALA2017111304057Power Supply · faultedAFT CABIN EMERGENCY LIGHT POWER SUPPLY TEST FAULTED. REPLACED THE POWER SUPPLY IAW AMM 33-51-38-400-001-A, TESTED OK.SDR CALA2017111104029Container · damagedLEFT OVERWING SLIDE CONTAINER DISBONDED AND CRACKED.SDR CALA2017111104028Battery Pack · failedEMERGENCY LIGHT TEST FAILED. EPSU BATTERY AFT LT. REPLACED EMERGENCY POWER SUPPLY BATTERY IAW AMM 33-51-38. OPS CHECKED GOOD.SDR CALA2017111004015Container · damagedRIGHT OVERWING SLIDE CONTAINER DISBONDED AND SEAL RETAINER HAS SHEARED RIVETS. INSTALLED A NEW OVERWING SLIDE.SDR CALA2017111004014Lens · missingEMERGENCY LIGHT LENS AT SEAT 20A MISSING. REPLACED THE LENS.SDR CALA2017111003987Unknown · odorDURING DESCENT, .AC SYSTEM SMELLED LIKE OLD GYM SOCKS.. PERFORMED TSM 05-50-00-810-831-A, NO ODOR COMING OUT OF PACK SYSTEM, NO EVIDENCE OF ANY OIL LEAKAGE.SDR CALA2017110603960Power Supply · faultyEMERGENCY LIGHTING SYSTEM CHECK, LT OVERWING HATCH EEL EPSU FAILED PUSH TO TEST FUNCTION. REPLACE THE POWER SUPPLY CABIN EMERGENCY LIGHT.SDR CALA2017110603959Slide · delaminatedLT FUSELAGE, OVERWING SLIDE HAS AFT, LOWER SURFACE CORNER, HEAVILY DELAMINATED DAMAGED. REPLACED LT OVERWING SLIDE REF AMM 25-62-42-400-001-A.SDR CALA2017103003872Battery · faultedDURING 2SVC CHK, FOUND FAULT DURING THE CABIN EMERGENCY LIGHTS OPERATIONAL TEST, SYSTEM FAULT ''EPSU BATTERY FWD LEFT". PERFORMED OPERATIONAL CHECK OF ESS ALL CHECKS NORMAL NO FAULTS FOUND REF AMM 33-51-38.SDR CALA2017102703826Light · malfunctionedEMERGENCY LIGHT OPS CHECK FAILED, MESSAGE EPSU BATTERY FWD L CAME UP. RESET THE SYSTEM IAW AMM 23-73-00 OPS GOODSDR CALA2017102303766Power Supply · faultySOME EMERGENCY LIGHTS STAY ON IN REAR OF CABIN. REMOVED AND REPLACED POWER SUPPLY AND BATTERY AT 11WL IAW AMM 33-51-15.SDR CALA2017102303745Unknown · odorMUSTY, OIL SMELL IN CABIN ON DESCENT, SMELL DISSIPATES WITH PACK 2 OFF. PERFORMED TROUBLESHOOTING OF CABIN OIL FUMES, IAW A319/A320 TSM 49-00-00-810-921A12. PERFORMED PRE-CONDITIONING WITH APU. NO FUMES IN CABIN IAW A319/A320 AMM 12-33-21-618-001-A.SDR CALA2017102003657Stringer · corrodedBULK CARGO COMPARTMENT FRAMES 65 - 66, STRINGER 31R AT THE OUTFLOW VALVE IS CORRODED. REMOVED AND REPLACED THE STRINGER IAW SRM 51-42-11.SDR CALA2017101303615Circuit Breaker · malfunctionedWHEN PERFORMING A EMERGENCY LIGHT TEST, 'EPSU INT LOAD FWD L, AND EPSU BATTERY EMER R FAULTS GENERATED. RESET EMERGENCY LIGHTING TEST CIRCUIT BREAKERS AT 49 AND 121 VU PANEL, OPS TESTED OK.SDR CALA2017101303614Connector · dirtyDURING AN EMERGENCY LIGHT OPS CHECK, CHECK FAILED WITH ASSOCIATED MESSAGE, EPSU COMM EMER L, CLEANED THE CONNECTOR ON THE POWER SUPPLY AND PERFORMED AN OPS CHECK IAW AMM 33-51-00-810-801-A, OPS CHECKED GOOD, NO FAULTS NOTED.SDR CALA2017101303613Cover · missingROW 20ABC MISSING COVER FOR EMERGENCY LIGHT. REPLACED EMERGENCY LIGHT PROTECTIVE COVER.SDR CALA2017101303578Outflow Valve · malfunctionedVENT SKIN VALVE FAULT ON ECAM. PRESSURIZATION ISSUE. EMERGENCY DECLARED. REPLACED SKIN AIR OUTLET VALVE REF. MM 21-26-53. OPERATIONAL CHECKED GOOD IAW MM 21-26-00.SDR CALA2017100903573Power Supply · faultyACCOMPLISHED EMERGENCY LIGHT TEST, TEST FAILED. FAULTED FOR INTERIOR LIGHTS FWD. FOUND ESPU AT THE L1 DOOR FAULTING, REPLACED ESPU IAW AMM 33-51-38-00-001. TEST PASSED.SDR CALA2017100903572Power Supply · malfunctionedDURING A CIDS EMERGENCY LIGHT TEST, MAINTENANCE MESSAGE EPSU EXT LOAD FWD L DISPLAYED. RESET EPSU 10WL. OPS CHECKED GOOD.SDR CALA2017100903571Light · no testESPU EMERGENCY EXT L, CIDS FAULT DURING A NR 2 SERVICE EMERGENCY LIGHT TEST. FOUND BOTH LEFT OVERWING LIGHTS FAILED. REPLACED THE LIGHT ASSEMBLY IAW AMM 33-51-15-000-001, ACCOMPLISHED IDT INSPECTION IAW GMM 09-10-05 AND AMM 33-51-38-00 -01. NO DEFECTS NOTED.SDR CALA2017100903569Lens · missingFWD LT ENTRY DOOR, EMERGENCY LIGHT, ON THE LOWER FWD WALL, OTBD OF FA SEAT, IS MISSING THE LENS. REPLACED THE LENS. OPS CHECKED GOOD.SDR CALA2017100903570Switch · stuckEMERGENCY LIGHTS STUCK IN THE ON POSITION. CYCLED NSFSB SWITCH. EMERGENCY LIGHTS OPS NORMAL.SDR CALA2017100603527Slide · delaminatedLEFT OVERWING SLIDE HAS DELAMINATION AT TOP AFT CORNER. NEW SLIDE INSTALLED.SDR CALA2017100203417Power Supply · no testEMERGENCY LIGHTS FAILED TO TEST, FWD LEFT EPSU, REPLACED THE EPSU IAW MM 33-51-00. CHECKED GOODSDR CALA2017100203366Seal · leakingACRID, ELECTRICAL ODOR IN COCKPIT AND 1ST CLASS. NOTICABLE AT LOW DIFF PRESSURES. CHECKED AFT, FWD,AND BOTH SIDE E & E AREAS, NO SMOKE ODOR. PERFORMED AVEC TEST IAW AMM 21-26-00, NO FAULTS FOUND, PERFORMED BCL 1 AND 2 BITE TEST IAW AMM 24-38-00, NO FUALTSSDR CALA2017093003356Battery · failedDURING EMERGENCY LIGHT TEST, AFT AND RIGHT SIDE POWER SUPPLY UNIT BATTERIES, FOUND FAILED. REPLACED BOTH POWER SUPPLY UNIT BATTERIES PER AMM 33-51-38 , TEST GOOD.SDR CALA2017092503332Charger · inoperativeEMERGENCY LIGHT POWER SUPPLY BATTERY FAILED A BITE TEST. REPLACED THE POWER SUPPLY BATTERY CHARGER IAW AMM 33-51-3 8-401.SDR CALA2017092503322Unknown · odorAFT LAVATORY HAS AN ODOR LIKE BURNED PETROLEUM OR BURNED HYD FLUID. COULD NOT DETECT THE ODOR, ANYTHING ON OR AROUND AFT LAVATORY DOOR. CHECKED GOOD.
Back to Airbus A319-131