SDR CALA2017092403317Cids · intermittentEMERGENCY LIGHTS ILLUMINATE WITH THE SWITCH ARMED. EMERGENCY LIGHTS GO OUT AFTER RECYCLING TO OFF THEN ARMED. RESET CID SYS, ALL LIGHTS CHECKED NORMAL IAW 33-23-00SDR CALA2017092203300Battery Pack · no testEPSU BATTERY FWD LT MESSAGE APPEARED DURING CABIN EMERGENCY LIGHTS OPS CHECK. ACCOMPLISHED TEST SEVERAL TIMES WITH SAME RESULTS. REPLACED THE BATTERY IN THE POWER SUPPLY IAW AMM 33-51-38-401. OPS CHECKED GOOD.SDR CALA2017092203298Cylinder · low pressureRIGHT OVERWING SLIDE RESERVOIR CYLINDER PRESSURE IN THE RED BAND. REMOVED AND REPLACED THE CYLINDER IAW AMM 25-62-46-000-001-A, AND 25-62-46-400-001-A. OP CHECKED GOOD.SDR CALA2017092203267Housing · corrodedFWD CARGO POTABLE WATER VALVE INTERNAL HOUSING, FRAMES 28 - 29 STRINGERS 42 - 44L HAS CORROSION. REMOVED CORROSION AND FOUND TO BE BEYOND LIMITS IAW DWG D53230935. REMOVED AND REPLACED THE HOUSING IAW SRM 51-42-11-001, AND 51-44-11-0 01.SDR CALA2017092203266Spar · corrodedRIGHT OTBD FLAP FRONT SPAR FWD FACE HAS CORROSION OTBD OF THE NR 3 FLAP TRACK INSIDE CAVITY PANEL NR 2. BLENDED CORROSION AND OUT OF LIMITS IAW SRM 51-73-11. REMOVED AND REPLACED THE RT OTBD FLAP FRONT SPAR WEB AT THE FLAP TRACK IAW SRM 57-53-21-300-004.SDR CALA2017091803248Power Supply · failedAFT, LEFT CABIN EMERGENCY LIGHT EPSU FAILED. REPLACED THE EPSU IAW 33-51-38SDR CALA2017091803247Connector · shortedEMERGENCY LIGHT TEST FAILED, LEFT AFT POSITION WITH INTERNAL LIGHT FAILED. SEVERAL SEATS IN AFT CABIN TURN ON AND THEN OFF WHEN COMMANDED ON. ISOLATED TO SHORTED CONNECTOR 7260V6 IAW WD33-51-08. REPLACED THE CONNECTOR, OPS CHECKED NORMAL. NO DEFECTS NOTED.SDR CALA2017091803220Unknown · odorBURNING ELECTRICAL ODOR THGROUGH OUT AIRCRAFT. HAPPEN DURING DECENT. INSPECTED THE CARGO BAYS, AVIONIC COMPARTMENTS, GALLEYS AND CABIN. HAD CREW RUN BOTH ENGINES IDLE AT GATE WITH PACKS ON. NO ELECTRICAL ODOR NOTICED AFTER GROUND AIR WAS REMOVED. ACFT OK SDR CALA2017091803228Unknown · odorF/A REPORTS A FAINT SMOKE ODOR IN AFT AFT LAVATORY. NOT GETTING STRONGER, NO ODOR DETECTED IN AFT LAVATORY ON ARRIVAL. PERFORMED AN OPS TEST OF THE LAVATORY D SMOKE DETECTOR IAW AMM 26-17-00-710-001-A, CHECKED GOOD.SDR CALA2017091103152Bulb · inoperativeEMERGENCY LIGHTS WILL NOT TEST, CIDS MESSAGE FOR THE EPSU RT EXTERIOR LOAD. REPLACED THE BULB ON TH ERIGHT OVERWING DOOR IAW AMM 33-51-15. OPS GOOD.SDR CALA2017091103151Power Supply · inoperativeEMERGENCY LIGHTS TEST TO FAILED. REPLACED THE EPSU AND BATTERY 12WL IAW AMM 33-51-38, PB401.OK FOR SERVICESDR CALA2017091103148Battery · dischargedDURING EMERGENCY LIGHT TEST WITH THE PTP, EPSU AFT LEFT 13WL FAILED BATTERY TEST. REMOVED AND REPLACED THE EPSU BATTERY IAW AMM 33-51-38-000-002- A. PERFORMED OPERATIONAL TEST IAW AMM 33-51-00-710-001-A, NO DEFECTS NOTED.SDR CALA2017091103135Battery · dischargedDURING EMERGENCY LIGHT TEST WITH THE PTP, EPSU RIGHT 12 WL FAILED BATTERY. REMOVED AND REPLACED THE BATTERY IAW AMM 33-51-38-000-002- A. PERFORMED OPERATIONAL TEST IAW AMM 33-51-00-710-001-A, NO DEFECTS NOTED.SDR CALA2017090303040Battery Pack · inoperativeEMERGENCY LIGHT TEST FAILED AT PTP PANEL. REPLACED THE BATTERY AT EPSU 13WL IAW AMM 33-51-38. OK FOR SERVICESDR CALA2017090102962Unknown · odorMUSTY/FOUL ODOR FROM AIR CONDITIONING SYSTEM. PERFORMED AN OPERATIONAL TEST OF BLEED AND PACK SYS IAW AMM 21-00-0 0. NO ODOR EMINATING FROM AIR SYS. OTBD CREW WILL ATTEMPT TO ISOLATE COMPONENT IF ODOR RETURNS. OK TO CONTINUE.SDR CALA2017090303041Bracket · corrodedAFT CARGO UNDER FLOOR AREA, FLOOR SUPPORT BRACKETS LOCATED ON TOP OF FR59 BETWEEN STR41R-38L HAS SPOTS OF UPPER SURFACE CORROSION AND DOUBLE DRILLED HOLE. BLEND CORROSION AT FR59 STR41R-38L SUPPORT BRACKET FOUND TO BE O UT OF LIMITS, ALSO DOUBLE DRILL HOLE IAWSDR CALA2017090102982Stringer · corrodedCORROSION STRINGER 31R FRAMES 65-66 BELOW OUTFLOW VALVE. REMOVED AND REPLACED STR31R PN D5348004 721201 PO NO. 1035886.2 IAW A319 SRM 51-72-11SDR CALA2017090102977Shear Tie · corrodedFWD CARGO UNDER FLOOR AREA HAS SURFACE CORROSION ON THE SHEAR TIE LOCATED ON FRAME 29 BETWEEN STRINGERS 43-44R. EVALUATED AND REMOVED CORROSION FRO M CLEAT MATERIAL REMOVED WAS NOT WITHIN LIMITS IAW NSA2110. REPLACED SHEAR TIE WITH NEW CLEAT IAW SRM 51-72-11-9SDR CALA2017090102976Shear Tie · corrodedFWD CARGO BILGE SHEAR TIE FRAME 26, STRINGERS 43-44R HAS CORROSION. EVALUATED & REMOVED CORROSION FROM THE SHEAR TIE. MATERIAL REMOVED WAS NOT WITHIN LIMITS IAW NSA2110. REPLACED THE SHEAR TIE IAW 51-72-11-911-001, AND SRM 51-42-11-001SDR CALA2017082802943Slide · delaminatedRT OVER WING SLIDE HAS DELAM. 625 PROCURED NEW RT OVERWING SLIDE TO BE INSTALLED ON CARD 17-2562- 1-9912 OP 565.SDR CALA2017082802942Slide · delaminatedLEFT OW SLIDE HAS CORROSION AND DELAMINATION ALONG TOP EDGE. PROCURED NEW LT OW SLIDE TO BE INSTALLED ON CARD 17-2562-1-9911 OP 564.SDR CALA2017082802924Unknown · odorSTRONG CHEMICAL ODOR AROUND EXIT ROW. NO UNUSUAL ODOR PRESENT IN AREA.SDR CALA2017082802923Ecs · odorFOUL/MUSTY SMELL FROM A/C SYSTEM PERFORMED CLEANING OF ECS WITH PACKS ON HOT FOR 45 MINUTES. NO ODORS DETECTED. CKS OK ON COLD AS WELL. PER AMM 21-00-00-615-001 -ASDR CALA2017082802909Door Sill · corrodedCORROSION ON R-2 DOOR SILL WHERE AFT GIRT BAR FITTING ATTACHES. REMOVED AND REPLACED DOOR SILL IAW SRM 51-72-11-911-001 REV 119, SRM 51-42-11-001 REV 119 RECEIVED NEW SILL PN D53480043207 01 IAW SRM 53-41-14-001.SDR CALA2017082502896Connector · faultyEMERGENCY LIGHTS INOPERATIVE AT ROWS 12A AND 23A. R & R THE CONNECTORS AT SEATS 12A AND 23A. OPS CHECKED GOOD.SDR CALA2017082502861Nut Plate · corrodedCORROSION AROUND TWO NUT PLATES L2 DOOR SILL AT FRAME. REPAIRED IAW SRM 53-41-14-300-001, PARA 2A.SDR CALA2017082102820Oven · smokeAFT OVEN 405-131 SMOKING, SET OFF BOTH AFT LAVATORY SMOKE DETECTORS. PERFORMED OPS CHECK OF OVEN. NO FAULTS FOUND AT THIS TIME. OK FOR SERVICE.SDR CALA2017081802739Oven · odorFLT ATT. REPORTED A BURNING RUBBER SMELL NEAR THE FWD AFT LAV. GALLEY POWER SWITCH WAS SWITCH SHUT OFF AND SMELL DISSIPATED. ACCOMPLISHED CHK PER AMM05-51-10-200-801C1. ALL ELECTRICAL EQUIPMENT WAS OPERATED IN AFT CABIN AND GALLEYS. CHECKED CABIN AND GALLEYS ASDR CALA2017081402704Power Supply · inoperativeFOUND SEVERAL SEAT MOUNT EMERGENCY LIGHTS AND L2 DOOR 2L LT INOP DURING A SERVICE CHECK. REPLACED BATTERY AT RIGHT OVERWING AREA, CHKS GOOD. REPLACED THE 13WL POWER SUPPLY AFT LT, CHECKED GOOD. REPLACED THE LAMPS AT SEATS 25, 26, 29, 30, 34 AND DOOR 2L, EMERSDR CALA2017081402703Light · intermittentEMERGENCY LIGHTS GOING ON AND OFF UNCOMMANDED. RESET THE SYSTEM, OPS OK IAW MM 33-51-00SDR CALA2017080802545Battery · no testEPSU EXT LOAD EMERGENCY AND EPSU BATTERY FAULTS WHEN PERFORMING THE EMERGENCY LIGHTS TEST. REPLACED CENTER RT EPSU BATTERY IAW AMM 33-51-38.SDR CALA2017080802535Light · no testEPSU EXT LOAD FWD L MESSAGE SHOWN ON FA CIDS PANEL. TROUBLESHOT IAW TSM 33-51-00-810-808A. COMPLETED STEPS 2 A TO G, ALL WIRING CHECKED GOOD. CHECKED RESISTANCE IN LT SLIDE LIGHTS FOUND 10.9 OHMS RESISTANCE, RT SLIDE LIGHTS 296 OMS RESISTANCE. L1 AND R1 DOOSDR CALA2017073102461Fitting · crackedLEFT WINDSHIELD SIDE POST UPPER ATTACHMENT, INTERNAL SIDE, HOLE 3 IS CRACKED AT 9:00 POSITION SIDE POST LAYER. ACCOMPLISHED A REPAIR IAW ECRA 5310-07169.SDR CALA2017073102456Spring · brokenL1 DOOR GIRT BAR FLOOR FITTING ON LEFT SIDE, SPRING BROKEN ON GIRT BAR RETAINING CLIP. REPLACED SPRING IAW AMM 52-11-31-400-003-A, AND ADJUSTMENT CHECK IAW AMM 52-11-00-820-001-A. OPS CHECKED GOOD.SDR CALA2017073002452Light · intermittentEXIT PATH LIGHTING IS FLICKERING PERFORMED CIDS EMERGENCY SYS LIGHT TEST, NO FAULTS, RESET CIDS A S A PRECAUTION. OK FOR SERVICE.SDR CALA2017072802383Fan · failedMETALLIC AND BURNT PLASTIC SMELL IN CABIN. R CABIN FAULT ON COND PG . SMELL DISSIPATED IN 5 MIN. R AND R R/H CABIN RECIRCULATION FAN REF AMM 21-21-51. OPS CHECKED GOOD. OK FOR SERVICE.SDR CALA2017072802398Torque Box · corrodedAFT CARGO COMP TORSION BOX HAS SEVERAL WEB SPOTS OF CORROSION FROM FRAME 55R TO FRAME 59R. REMOVED AND REPLACED AFT CARGO TORSION BOX WEB IAW SRM 51-7 2-911-002.SDR CALA2017072802395Access Door · bentTHS ACCESS DOOR IS BENT, FOUND TO BE OUT OF LIMITS IAW SRM 51-41-23-283-002, REV 118. REMOVED AND REPLACED THE ACCESS DOOR IAW SRM 51-72-11-911-001, REV 118, AND AMM 52-41-16-400-0 01SDR CALA2017072802394Plate · corrodedDURING AFT CARGO BILGE AREA CLEANING, FOUND CORROSION ON FRAME 68, STRINGERS 43L - 43R REENFORCING PLATE. REMOVED AND REPLACED THE PLATE IAW SRM 51-42-11, 51-74-00, 51-73-11, 51-44-11, DRAWING 11304 AND SRM 51-72-11.SDR CALA2017072402371Sensor · damagedEMERGENCY EXIT ON DOOR PAGE FOR LEFT SIDE AIRCRAFT ON AND OFF. ACP CONTINUITY CHECK OF WIRING IAW AWM 31-54-45 &52-73-06. ALL CHECKED GOOD. FOUND PROXIMITY SENSOR 2WN1 LOOSE INTERNALLY, REPLACED THE PROXIMITY SENSOR IAW AMM 52-73-11-400-004-C AND OPS CHECKESDR CALA2017072102333Lens · brokenEMERGENCY EXIT LIGHT LENS BROKEN ON RIGHT SIDE OF AIRCRAFT. REPLACED EMERGENCY EXIT LIGHT LENS ON RIGHT SIDE OF AIRCRAFT.SDR CALA2017072102288Fitting · corrodedDISCOVERED CORROSION ON THE AFT CARGO DOOR CUT OUT FWD CORNER FITTING. DURING REMOVAL OF MIN OR SCRIBE MARKS ON THRESHOLD STRUCTURE, BLENDED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 51-73-11-001, REV 118, INSTALLED A NEW FITTING IAW SRM 51-72-11 -911SDR CALA2017081402666Shear Tie · corrodedAFT CARGO SHEAR TIE IS CORRODED AT STRINGERS 41L - 42L. BLENDED CORROSION ON AFT CARGO SHEAR TIE AND FOUND TO BE OUT OF LIMITS IAW SRM 51-73-00. FABRICATED NEW SHEAR TIE IAW DRAWING 53476518 AND INSTALLED IAW SRM 51-42-11.SDR CALA2017081402665Door Sill · crackedL2 DOOR SILL AT LOWER ANGLE FRAME 68 IS CRACKED. REMOVED AND REPLACED L2 DOOR SILL FRAMES 66 - 68 IAW SRM 51-72-11, AND SRM 51-42-11, REV 118.SDR CALA2017071402198Support Fitting · crackedAFT CABIN SUPPORT FITTING FOR BEAM Y1162 IS CRACKED AT FR 68 REMOVED CRACKED AFT CABIN SUPPORT FITTING FOR BEAM Y1162 FR-68, RECEIVED NEW SUPPORT FITTING AND INSTALLED FITTING IAW SRM 51-72-11, AND 51-42-11, REV 118.SDR CALA2017071402197Fitting · out of positionL2 SILL FWD CORNER FITTING HAS INTERFERENCE WITH LWR NO.6 DOOR STOP. REMOVED AND REPLACED FWD LOWER L-2 CORNER FITTING IAW RFTS OPS 6 0039 NR 41, IAW SRM 51-72-11-912-001, 51-44-11-001, 51-75-12-0 01, 51-21-11-001, REV 118, 51-75-12-001, AND 53-41-79.SDR CALA2017071402196Angle · damagedFRAME 67 HAS ONE OUT OF ROUND HOLE AT ATTACHMENT TO THE L2 DOOR SILL REMOVED THE OLD CLEAT AND INSTALLED IAW SRM 51-72-11-119-001, AND 51-42- 11-001, REV. 118.SDR CALA2017071402195Hinge Fitting · out of positionRIGHT ELEVATOR NR 6 HINGE FITTING HAS A LARGE GAP ON INBOARD SIDE BETWEEN HINGE ARM. REMOVED AND REPLACED WITH A NEW RT ELEVATOR HINGE FITTING IAW SRM 51-42-11 AND SRM 51-2211.SDR CALA2017071002179Switch · malfunctionedEMERGENCY EXIT LIGHTS STAY ON WITH SWITCH IN ARMED OR OFF POSITION. RESET NSFSB SWITCH - OPS CHECKS GOOD.SDR CALA2017071002178Power Supply · malfunctionedEPSU LEFT FAULTS DURING EMERGENCY LIGHT TEST AT CIDS PANEL RESET EPSU CIDS SYSTEM PER TSM33-51-38. GROUND BIT TEST NORMAL REF AMM33-51-00. OPS CHECK OK
Back to Airbus A319-131