Airbus A319-131
Service difficulty reports · 5,795
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A319131' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A319131' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2017050501256Altimeter · faultySTBY ALTIMETER STICKS AND THEN JUMPS 500-600 FEET DURING DESCENT. INSTALLED ALTIMETER PER AMM 34-21-22.SDR CALA2017050501249Proximity Sensor · faultyLGCIU 1 FAULT DISPLAYED ON UPPER ECAM SCREEN . EMERGENCY DECLARED. PERFORMED TSM TASK 32-31-00-810-819-A FOR CFDS FAULT MSG "R LG DOOR CLOSED PROX SNSR (26GA)/LGCIU (5GA1)" CODE 32-31-73. REPLACE D 26GA SENSOR IAW AMM32-31-73-000-001-A/400-001-A. BITE TEST, ANSDR CALA2017050101227Power Supply · no testDURING TEST OF EMERGENCY BATTERIES, THE EPSU BATTERY AFT LT FAILED TO TEST. REPLACED EMERGENCY POWER SUPPLY. OPS CHECKED OK.SDR CALA2017050101226Bulb · inoperativeEPSU EXT LOAD EMERGENCY LIGHT MESSAGE ON CIDS PANEL WHILE ACCOMPLISHING EMERGENCY LIGHT TEST. REMOVED AND REPLACED THE FWD OVERWING SLIDE LIGHT BULB IAW AMM 33-5 1-15, OPS CHECKED GOOD. NO DEFECTS NOTEDSDR CALA2017050101225Battery Pack · no testOPS TEST OF EMERGENCY LIGHT SYSTEM. FOUND CIDS FAULT ON TEST. EPSU BATTERY FWD L FAULT ON TEST AND TROUBLESHOT. REMOVED AND REPLACED FWD OVERWING BULB IAW AMM 33-51-15, OPS CHECKED GOOD, REPLACED BATTERY, TESTED GOOD. PERFORMED IDT INSPECTION. NO DEFECTS NSDR CALA2017050101224Battery Pack · no testEMERGENCY LIGHTS TEST FAILED. EPSU BATTERY EMER R. REPLACED RIGHT EPSU BATTERY PER MM 33-51-38. OPS CK GOOD.SDR CALA2017050101223Lamp · inoperativeMESSAGE EPSU EMERGENCY LOAD RT APPEARED. REPLACED TWO LAMPS. OP CHECKED GOOD IAW AMM 33-51-15. AND AMM 33-51-00.SDR CALA2017050101222Power Supply · inoperativeEMERGENCY LIGHTS TEST FAILED AT PTP PANEL. REPLACED THE EPSU AT 11WL IAW AMM 33-51-38 PB401. OK FOR SERVICESDR CALA2017042801163Battery · not seatedEPSU BATTERY EMER L CIDS MESSAGE DISPLAYED AFTER TEST ATA 33-51-38. RESET THE EPSU BATTERY, SYSTEM CHECKED OK PER MM 33-51-00.SDR CALA2017042801146Apu · leakingAIR COND HAS AN OILY SMELL WHETHER USING ENG BLEED OR APU BLEED. RAN ENGINES ISOLATED TO NR 1 ENGINE SMELLS THE STRONGEST IN THE COCKPIT APU WAS LEAKING OIL AND HAVING IT SUCKED INTO INLET. REPLACED APU REF MM 49-11-11. OPS CHECKED NORMAL. RAN ENGINES AND APSDR CALA2017042101080Cover · brokenPLASTIC COVER FOR EMERGENCY EXIT LIGHTS IN AFT CABIN MISSING. REPLACED THE COVER.SDR CALA2017042101079Light · no testCABIN EMERGENCY LIGHT OPS CHECK IS FAILING PER 2 SVC RESET AFT L CENTER EPSU BATTERY. GROUND TESTED GOOD IAW 33-00-00.SDR CALA2017042101058Unknown · odorF/A REPORTED A SLIGHT OVERHEAT BURNING ODOR IN FWD LAVATORY. NO SMOKE OR FUMES DETECTED. INSPECTED THE FWD LAVATORY, UNDER SINK AREA. NO BURNING ODORS NOTED. OK FOR SRVICE.SDR CALA2017041701029Warning System · false activationON 2 SERVICE CHECK. DURING EMERGENCY LIGHTS OPS CHECK PTP DISPLAYED EPSU INT LOAD EMER L FAULT. WAITED A FEW HOURS. ACCOMPLISHED OPERATIONAL TEST OF EMERGENCY LIGHTS REF MM 33-51-00, TEST OK.SDR CALA2017041400963Proximity Sensor · faultyL/G SHOCK ABSORBER FAULT. EMERGENCY DECLARED. CLEARED ITSELF DURING DESCENT AT 11000 FEET. WHILE SPEAKING TO THE PILOT IN FLIGHT HE ALSO OBSERVED THE FOLLOWING WARNINGS: AUTO FLT AP OFF AUTO FLT A/THR OFF ANTI ICE STBY PITOT L/G SHOCK ABSORBER FAULT L/G RETRASDR CALA2017041000950Lanyard · out of positionAFT SLIDE DOOR 2R WILL NOT DISARM FOUND LANYARD PROTRUDING AT BOTTOM OF GIRT BAR, RESTOWED LANYARD. ALSO LUBED GIRT ATTACH POINTS AND ROLLERS. DOOR ARMED DISARMED OK.SDR CALA2017041000947Warning System · false activationAUTO FLT ''AP OFF'' AND ''A-THR OFF'' DISPLAYED ON UPPER ECAM SCREEN. EMERGENCY DECLARED. SUSPECTED LGCU 1 FAULT PERFORMED BITE TEST ON LGCU1 TEST OK MESSAGE CLEARED.SDR CALA2017040700903Battery Pack · no testEMERGENCY LIGHTS FAILED TO TEST. REPLACED THE AFT LEFT POWER SUPPLY BATTERY PACK. OP CHECKED NORMAL.SDR CALA2017040700902Door Sill · dirtyL2 DOOR SLIDE NOT ARMED, DISPLAYED WITH DOOR PRESSURE LIGHT FLASHING. CREW REPORTED NO PRESSURIZATION ISSUES AND NO DOOR HANDLE MOVEMENT. FLT CREW REPORTS L2 DOOR ARMING HANDLE DID MOVE UP SLIGHTLY. FLT ATTENDENT RESET HANDLE AND THE L2 DOOR DID ARM AND PRESDR CALA2017040700852Windshield · failedF/O FWD WINDSCREEN OUTER PANE SHATTERED. EMERGENCY DECLARED. REMOVED & REPLACED THE WINDSHIELD IAW MM 56-11-00 & 56-11-11.SDR CALA2017040400805Unknown · odorSTRANGE ODOR IN CABIN. SMELLS LIKE BURNT OIL OR RUBBER. GAVE FA A HEADACHE RAN BOTH PACKS, COULD NOT DUPLICATE SMELL, CHECK ENG AND HYDRAULIC FLUID LEVELS CHECKED GOOD. REPLACED BOTH RECIRCULATION FILTER S PER AMM 21-21-41-400-001-A.SDR CALA2017033100768Controller · failedCREW REPORTED AT 6000 FT, CABIN PRESSURE LIGHT ON ECAM. AT 8000 FT, CREW RECEIVED A MASTER CABIN PRESSURE LIGHT. UNABL E TO CONTROL THE PRESSURIZATION AS CABIN CLIMBED. NEVER ASSENDED ABOVE 10000 FEET. TROUBLESHOT IAW TSM 21-31-00-810-831-A, AND FOUND A CPSDR CALA2017032600737Epsu · defectiveESCAPE PATH LIGHTS ROW 10-11 INOP. T/S FOUND EMERGENCY POWER SUPPLY UNIT 10WL DEFECTIVE. REMOVED AN D REPLACED EPSU AMM 33-51-38. OPS CKS GOOD.SDR CALA2017032500720Altimeter · faultySTANDBY ALTIMETER INDICATION ERRONEOUS AT FL370 STBY ALT READS FL358. ACCOMPLISHED FUNCTIONAL TEST REF AMM34-21-00. STBY ALT NEEDLE STICKS. REPLACED STBY ALTIMETER REF AMM34-21-22 OPS CHECKS NORMAL.SDR CALA2017032400677Safety Valve · damagedG RSVR LO LVL DISPLAYED ON UPPER ECAM SCREEN. EMERGENCY DECLARED. FOUND SAFETY VALVE 49GA IN RIGHT WHEEL WELL DAMAGED AND CAUSING FLUID LOSS. REPLACED LANDING GEAR SAFETY VALVE IAW AMM 32-31-17. SERVICED GREEN HYD IAW AMM12-12-29. TESTED NORMAL IAW AMM32-33SDR CALA2017032100672Power Supply · inoperativeEMERGENCY LIGHT TEST FAILED. REPLACED EMERGENCY POWER SUPPLY REF 33-51-38. OPS CHECK GOOD.SDR CALA2017032100671Power Supply · inoperativeDURING CABIN EMERGENCY LIGHTS OPERATIONAL CHECK THE TEST FAILED, MESSAGE ESPU BATTERY FWD L 33-51-38. REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNIT 10WL IAW 33-51- 38. OPS CHECK GOOD.SDR CALA2017031700647Power Supply · malfunctionedEMERGENCY LIGHTS FAILED AN OPS CHECK, MESSAGE FOR EPSU UNIT FWD LT. RESET THE POWER SUPPLY AT THE L1 DOOR. TESTED OK IAW AMM 33-51-00-501SDR CALA2017031700646Relay · faultedCABIN EMERGENCY LIGHTS FLASHING INTERMITTENTLY AFTER ENGINE SHUTDOWN. CONTINUED EVEN AFTER TROUBLESHOOTING IAW TSM 33-51-00-810-819A, REPLACED THE RELAY 8WL IAW ASM 33-51-00, OP CHECKED OK.SDR CALA2017031700645Circuit Breaker · malfunctionedSLIDE ARMED LIGHT STAYS ILLUMINATED WITH SLIDE IN THE DISARM POSITION . CYCLED THE CIRCUIT BREAKER 121-P10, TESTED OK IAW MM 52-73-00-710-001-ASDR CALA2017031700644Battery Pack · inoperativeEMERGENCY LIGHT POWER SUPPLY FOUND INOPERATIVE. REPLACED THE BATTERY PACK IAW AMM 33-5 1-38-000-002A, AND 33-51-38-400-002A, OPS CHECKED GOOD.SDR CALA2017031700609Arm · gougedLEFT HORIZONTAL STABILIZER NR 4 HINGE ARM GOUGED UNDER LOCK FASTENER COLLAR AT FWD OTBD UPPER ATTACH FLANGE. REMOVED AND REPLACED THE ARM IAW SRM 51-72-11, PG. 12.SDR CALA2017031300598Warning System · false activationDOOR 2R SLIDE ARMED LIGHT ILLUMINATED IN FLIGHT. CYCLED DOOR. DOOR ARMED AND DISARMED. NO DEFECTS FOUND WHILE ARMED. OPS CHECK GOOD REF AMM 52-13-00.SDR CALA2017031000573Power Supply · faultyCABIN EMERGENCY LIGHTS OPERATIONAL CHECK FAILED. MSG,"EPSU UNIT AFT L". REF JOB CARD 17-0550-8-0002. REPLACED EPSU AND BATTERY REF AMM 33-51-38-40 1. PERFORMED OP TEST OF EMERGENCY LIGHT SYSTEM REF AMM 33-51-00- 710-001-A. TEST OK.SDR CALA2017030600554Connector · looseSEAT ROW 2AB EMERGENCY EXIT PATH LIGHTS FAILS TO ILLUMINATE WHEN TESTED. SECURED CONNECTOR UNDER SEAT,OPS CKD OKSDR CALA2017022400478Power Supply · faultyAFTER EMER LTS TEST, RESULT EPSU FWD LT. REPLACED FWD EPSU AND BATTERY PER MM 33-51-38. OPS CK GOOD.SDR CALA2017022400445Skin · dentedDENT IN RIGHT FORWARD FUSELAGE JUST BELOW AND FORWARD OF DOOR 1R. REPAIRED DENT IN FUSELAGE PER ECRA 5311-01852. ACP PERM REPAIR IN 335D OR 20 FEB 2018 TOMC-APPROVAL. ACCOMPLISH A PERMANENT REPAIR AT FR12-13 RT FUSELAGE SKIN JUST BELOW THE Z-520 FLOOR LEVEL PESDR CALA2017081402644Shear Tie · corrodedFWD CARGO UNDER FLOOR AREA SHEAR TIE, FRAME 30, STRINGERS 43 - 44R. REMOVED AND REPLACED THE SHEAR TIE IAW SRM 51-42-11.SDR CALA2017022000440Connector · looseTWO CONSECUTIVE SEAT ROWS OF EEL LIGHTS INOP AT ROW 12 AND 20. ROW 20 HAS A RED EXIT ROW LIGHT INOP ALSO. SECURED LOOSE CONNECTOR AT LOWER SIDEWALL, ROW 12. LIGHT CHECK OKSDR CALA2017022000439Power Supply · inoperativeBATTERY EMERG POWER SUPPLY ON RT INOP. REPLACED BATTERY EMERG POWER SUPPLY IAW AMM 33-51-38-000-001-A, AND 33-51-38-400-001-A. OPERATIONAL TEST OK.SDR CALA2017081402643Plate · chafedNR 1 ENGINE LOWER PLATE IS CHAFED. INSTALLED NEW PLATE IAW SRM 54-51-12 FIG 202.SDR CALA2017022000429Plate · chafedNR 2 NACELLE LOWER CHAFE PLATE HAS A CHAFE. REMOVED AND REPLACED THE CHAFE PLATE IAW SRM 54-51-12, F 202, PAR 5B.SDR CALA2017022000428Stringer · corrodedFWD CARGO STRINGER 43L HAS SURFACE CORROSION FRAMES 30 - 31. REMOVED AND REPLACED THE STRINGER IAW SRM 51-42-11, PARA 7.SDR CALA2017021700387Battery Pack · no testEMERGENCY LIGHT TEST FAILED AT PTP PANEL. REPLACED BATTERY PACK AT EPSU 13WL. OK FOR SERVICE IAW AMM 33-51-3 8 PB401SDR CALA2017021700386Power Supply · inoperativePOWER SUPPLY BATTERY INOPERATIVE. REPLACED THE BATTERY PACK IAW AMM 33-51-38-040 1. OPS CHECKED GOOD.SDR CALA2017021700405Tee Fitting · corrodedLEFT EMERGENCY EXIT DOOR LOWER CUTOUT AFT AND FWD SKIN CORRODED ON INNER SKIN AT ATTACH POINTS. REMOVED AND REPLACED THE TEE FITTINGS IAW SRM 51-42-11.SDR CALA2017021700404Cleat · corrodedFWD CARGO UNDER FLOOR AREA CLEAT ON FR29 STR43R HAS SURFACE CORROSION. REMOVED AND REPLACED THE CLEAT IAW SRM 51-42-11, PAR 7.SDR CALA2017081402641Doubler · corrodedFWD CARGO UNDER FLOOR AREA INNER SKIN HAS SURFACE CORROSION ON DOUBLER FWD OF FRAME 31 AND STRINGERS 43 - 44R. REMOVED AND REPLACED THE DOUBLER.SDR CALA2017081402640Shear Tie · corrodedC2, FWD CARGO UNDER FLOOR AREA SHEAR TIE ON FRAME 28, STRINGERS 42R - 43R. REMOVED AND REPLACED THE SHEAR TIE IAW SRM 5 1-92-11.SDR CALA2017081402639Shear Tie · corrodedC2, FWD CARGO UNDER FLOOR AREA SHEAR TIE ON FRAME 29 AND STRINGER 43L HAS SURFACE CORROSION. REMOVED AND REPLACED THE SHEAR TIE IAW SRM 51-42-11, FIG 8.
Back to Airbus A319-131