SDR CALA2017021300341Cleat · corrodedC2, FWD CARGO UNDER FLOOR AREA CLEAT ON FR26 AN D STR43R HAS SURFACE CORROSION. REMOVED AND REPLACED CLEAT AT FR26 STR43R IAW SRM 51-42-11 FIG 8 PGS 23-24 AND PGS 31-32.SDR CALA2017021300340Stringer · corrodedAFT CARGO STRINGER 43L IS CORRODED FROM FRAME 54 TO FRAME 56. REPAIRED PER 53-00-13 FIG 202 SHT 5.SDR CALA2017021300364Proximity Switch · out of adjustDOOR 2R SLIDE ARMING PROX SWITCH 7NW2 WAS FOUND OUT OF TOLERANCE . ADJUSTED THE DOOR 2R SLIDE ARMING PROXIMITY SWITCH 7NW2 WITH REF TO AMM 52-71-00-820-002-A01.SDR CALA2017021300355Filter · dirtyACRID SMELL IN COCKPIT THAT EVENTUALLY WENT THROUGHOUT CABIN. REMOVED AND REPLACED RECIRCULATION FILTERS REF AMM 21-21-41 AS REQUESTED BY TOMC. OPERATED APU AND APU BLEED SYS. ALSO OPERATED BOTH ENGINES AND ENG BLEED SYS. NO ODORS NOTED IN FLIGHT DECK, CABIN OSDR CALA2017021300354Oven · faultyAFT GALLEY OVEN R42 POPPED ITS CB AS IT WAS PUT UNDER LOAD FOR REPORTED BURNING SMELL IN CABIN. INSTALLED SERVICEABLE OVEN OPS CHECK GOOD.SDR CALA2017021300339Stringer · corrodedSTRINGER 31R FROM FRAMES 64 - 67 CORRODED BEYOND LIMITS. STRINGER REPLACED IAW SRM 51-42-00, AND SRM 53-41-13, FIG 11.SDR CALA2017021200331Oven · defectiveELECTRICAL BURNING SMELL THROUGHOUT CABIN. NO SMOKE PULLED FWD AND AFT GALLEY BREAKERS, APPLY POWER TO GALLEYS. TURNED ONE GALLEY DEVICE AT A TIME. FOUND NO FAULTS OR ODORS IN FORWARD GALLEY. AFT GALLEY DID PRESENT SOME HEAT/OVERHEAT ODORS AT TIMES, NOT ELESDR CALA2017021200334Power Supply · faultyEMER LIGHTS FAIL SYS TEST. REPLACE EMER LIGHT AFT POWER SUPPLY. OPS CK GOOD. REF AMM 33-51-38-400-001-A & IPC 33-51-04-07SDR CALA2017021000310Skin · damagedDURING RUDDER INSTALL FOUND SMALL PUNCTURE ON RT SIDE OF RUDDER ABOUT 18 INCHES AFT OF LOWER FWD HOST POINT AND 20 INCHES UP FROM BOTTOM OF RUDDER ALSO A SCRATCH ON UPPER HALF. PERMANENT REPAIR ACCOMPLISHED PER ECRA 5540-01477 AND REO L205285.SDR CALA2017020600290Battery · dischargedEPSU UNIT FWD L MESSAGE DISPLAYED AT CONCLUSION OF EMERGENCY LIGHT TEST. REPLACED EPSU BATTERY REF AMM33-51-38 OPS CHECKED GOOD.SDR CALA2017020300257Light · malfunctionedEMERGENCY EXIT LIGHT FOR LEFT OVERWING EXIT IS ON IN FLIGHT RESET SYSTEM, OPS CHECKED NORMALSDR CALA2017020300259Battery · faultyEMERGENCY LIGHTS TEST FAIL AT PTP PANEL. REPLACED THE BATTERIES AT EPSU UNITS 10WL AND 13WL IAW AMM 33-51-38 PB401. OK FOR SERVICESDR CALA2017020300245Fan · faultyTHERE WAS A SLIGHT ELETRICAL OR PAPER BURING ODOR IN CABIN AND COCKP IT. NOTICED FAN AMBER ON REMOVED AND REPLACED LEFT CABIN RECIRCULATION FAN IAW AMM 21-21-51. REPLACED RECIRCULATION FILTER IAW AMM 21-21-41. OPERATIONAL CHECKED GOOD IAW AMM 21-21-00-710-001-SDR CALA2017020300258Light · malfunctionedUNABLE TO SHUT OFF EMERGENCY EXIT LIGHTS.SDR CALA2017013000217Power Supply · faultyL AFT EMERG POWER SUPPLY HAS UNIT FAIL LIGHT ILLUMINATED. REMOVED AND REPLACED L AFT EPSU AND BATTERY REF AMM 33-51-38. TESTED GOOD REF AMM 33-51-38-400-001-A.SDR CALA2017013000216Power Supply · faultyWHEN PERFORMING EMERGENCY LIGHT CK ON 2 SERVICE GOT FAULT EPSU UNIT EMER L MESSAGE. UNABLE TO CLEAR. REPLACED EMERGENCY POWER SUPPLY UNIT AND BATTERY AT 11WL PER 33-51-38AMM. OPS CK GOOD.SDR CALA2017013000201Fan · faultyEXTRACT FAULT DISPLAYED ON UPPER ECAM SCREEN. VENT MILD FUMES AND FAULT LIGHT. PLACED IN/OVRD. FUMES CLEARED RAPIDLY. REMOVED AND REPLACED AVIONICS EXHAUST FAN AT LOCATION 18HQ, REF AMM 21-26-51-400-001A. OPS CHECKS GOOD.SDR CALA2017012900191Angle · corrodedCORROSION ON L2 DOOR SILL ON EXISTING REPAIR AT FR68. REMOVED AND REPLACED REPAIR ANGLE IAW SRM 53-41-14 FIG 201 AND SRM 51-72-11.SDR CALA2017012900190Stringer · corrodedAFT CARGO COMPARTMENT STRINGER 39R H AS CORROSION AT FRAME 61 REMOVED AND REPLACED STRINGER 39R IN AFT CARGO COMPARTMENT BETWEEN FRAME 61 TO FRAME 64 IAW SRM 51-42-11 PARAGRAPHS 5,6, AND 7.SDR CALA2017012300171Battery Pack · inoperativeFLASHLIGHT AT THE L2 DOOR, RED LIGHT NOT BLINKING. REPLACED THE BATTERY PACK, CHECKED OK.SDR CALA2017012300170Battery Pack · faultedEMERGENCY LIGHT SYS TEST FAULTED FOR THE EPSU UNIT AND AFT EPSU BATTERY. REPLACED BATTERY PACK, TEST PASSED. IAW MM 33 51 38 000 002A,SDR CALA2017012200152Line · unsecureMUSTY ALMOST METALLIC SMELL NOTED IN DESCENT. SUSPECT SOMETHING LEAKING INTO BLEED SYSTEM. TROUBLESHOT SMELL TO APU BLEED. FOUND OIL SCAVENGE LINES TO AFT BEARING ON APU LEAKING OIL. SECURED LINES AND CLEANED AREA. RAN APU AND PACKS TILL SMELL DISSIPATED.SDR CALA2017011600115Valve · faultyAFTER PUSHBACK WITH ENG1 RUNNING AND PARKING BRAKE ON. ALL BRAKE PRESS LOST AND ACCUM LOST TROUBLESHOT REF TSM 32-44-00-810-808-A TO STEP 4A (3)(A). NEED TO R&R ALTN BRK DISTR DUAL VALVE REF AMM 32-43-14-000-001-A REMOVED VALVE REF AMM 32-43-14-000-001-A COMPLSDR CALA2017011600125Battery · dischargedEMERGENCY LIGHT TEST FAILED FOR EPSU BATTERY AFT L. REPLACED BATTERY FOR AFT L. OPS CK GOOD. REF AMM 33-51-38/401SDR CALA2017010900055Power Supply · faultyBATTERY EMERG POWER SUPPLY FOUND INOP AT FWD LT CABIN. REPLACED BATTERY EMERG POWER SUPPLY LT FWD IAW AMM 33-51-38-000- 002A AND 33-51-38-400-002A, OPS CK GOOD.SDR CALA2017010900033Skin · corrodedCENTER WING TANK UPPER SKIN AT FWD OF FR43 RT O/B OF 1292 SEAT TRACKS C1 HAS CORROSION. INTERIM REPAIR ACCOMPLISHED PER ECRA5710-02585 PART 1. ACCOMPLISHED HFEC SURFACE SCAN IAW NTM 51-10-16. ACCOMPLISH INITIAL INSPECTIONS OF THE AFFECTED AREA PER PART 2 OF ECSDR CALA2017010600020Fire Warning · false activationENG START AND IGN PYLON PEDESTAL INTERMITTENTLY ILLUMINATING FIRE NO FIRE WARNING OR ECAM DEFERRED DIRECTLY BY TOMC FIRE LIGHT ON NR 1 ENG CONTROL PANEL INTERMITTENT INOP. ACCOMPLISH FIM TASK 26-21-00-810-819-B FOR POSSIBLE ENGINE NOR1 FIRE, OR ENGINE NR 1 FIRSDR CALA2017010600031Battery · dischargedEMERGENCY LIGHTS TEST FAILED AT PTP. REPLACED BATTERY AT 12WL EPSU REF AMM 33-51-38PB401. NOW OK FOR SERVICE.SDR CALA2016123001199Connector · looseEPSU INT LOAD FWD LEFT FAULT WHEN PERFORMING EMERGENCY LIGHTS TEST RESEATED BATTERY PACK AND RESEATED CONNECTOR ON POWER SUPPLY,RET ESATED SYSTEM AND CHECKS OKAY.SDR CALA2016123001198Power Supply · inoperativeEMERGENCY LIGHTS TEST FAILED AT PTP PANEL CABIN EMERGENCY POWER SUPPLY AND BATTERY POS 13WL WERE REPLACED IAW AMM 33-51-38 PG BLOCK 401 OP TEST IAW 33-51-38-740-050SDR CALA2016121901124Pcu · faultedCABIN EMERGENCY LIGHT TEST FAILS. MESSAGE IS AFT L PSCU IS AT FAULT. REPLACED EMERGENCY POWER CONTROL UNIT IAW 33-51-39.SDR CALA2016121901123Unknown · malfunctionedEMER EXIT LIGHT ON CONSTANTLY. CYCLED SWITCH NO HELP. NOTED FASTEN SEATBELT SWITCH ON, SWITCHED OFF. EMERGENCY EXIT LIGHTS ARE OFF NOW.SDR CALA2016120501033Epsu · faultyEMERGENCY LIGHT TEST FAULTED EPSU BATTERY EMER. REMOVED FAULTY EMER BATT AT RT O/W REF MM33-51-38. INSTALLED EPSU BATTERY REF MM 33-51-38-000. OP CHECK NORMALSDR CALA2016112500971Cids · malfunctionedEMERGENCY LIGHT TEST NOT OK EPSU BATTERY AFT LEFT. RESET CIDS SYS GRD TEST EMERGENCY SYS THRU FWD ATT PNL, TEST OK NO MSG NOTEDSDR CALA2016112500970Battery Pack · faultedFWD EPSU FAULT LIGHT DURING TEST REPLACED EMERGENCY BATTERY PER AMM 33-51-38. NOW OKSDR CALA2016111100879Connector · disconnectedEMERGENCY AISLE PATH LIGHT INOP IN SEAT 21. FOUND CONNECTOR AT SEAT FOOT DISCONNECTED. SECURED SAME AND ALL CKS NORM. ACFT OK TO CONTINUE.SDR CALA2016110700863Pump · unserviceableEMERGENCY DECLARED. PUMP INDICATION, LEFT TANK PUMP 1 INOP & RIGHT TANK PUMP 1 INOP ON FUEL SYSTEM ECAM. FOUND LT WING TANK PUMP1 AND PUMP 2 LOW PRESSURE. RESET CB A14. FOUND PUMP 1 TO OPERATE NORMALLY. PUMP 2 FOUND TO BE INTERMITTENT. REPLACED BOTH LT WSDR CALA2016110295889Skin · crackedLT FUSE SKIN AT FR35 STR 30L HAS A CRACK INDICATION ON HOLE MARKED 2. INTERIM REPAIR ACP IAW EC RA5330-05813 PART 1.SDR CALA2016110295888Skin · crackedRT FUSE SKIN AT FR35 STR 30R HAS A CRACK INDICATION ON HOLE MARKED 2. INTERIM RPR ACP IAW ECRA 5330-05813 PART 1.SDR CALA2016103195877Fitting · corrodedR1 DOOR SILL FWD GIRT BAR FITTING AREA CORROSION AROUND FWD OUTBD, AFT INBD, & AFT OUTBD HOLE AT FR20 STR23. REMOVED CORROSION BY SPOT FACING ALL 3 HOLES ON FR20 .017 .025 .020 MATERIAL REMOVED & FOUND TO BE IN LIMITS IAW A319 SRM53-11-14 FIG 108 PARA 7B FABSDR CALA2016102495852Skin · dentedFUSELAGE SKIN DENTED AT FRAME 23 BETWEEN STRINGERS 24 AND 25L FOUND OUT OF LIMITS. INSTALLED DOUBLER REPAIR PER SRM53-00-11 FIG 232SDR CALA2016102495851Threshold · corrodedFWD CARGO THRESHOLD WEB HAS CORROSION AND FOUND OUT OF LIMITS. REMOVED AND REPLACED IAW SRM 53-21-13 PG 101-104.SDR CALA2016102495837Doubler · dentedMAJOR REPAIR. DOUBLER REPAIR AFT OF DOOR 1L IS DENTED AT FRAME 23 JUST ABOVE FLOOR LEVEL. INSTALLED DOUBLER IAW SRM 53-11-11 FIG 211. MAJOR REPAIR.SDR CALA2016101995833Door Sill · corrodedL2 DOOR CUTOUT FWD LOWER CORNER HAS CORROSION. REMOVED AND REPLACED L2 DOOR SILL IAW SRM 51-42-11.SDR CALA2016101995818Door Sill · corrodedL2 DOOR SILL FR68 HAS CORROSION AROUND THE LAST TWO NUT PLATE HOLES AFT END AT DOOR SILL. REMOVED CORROSION AND FABBED REPAIR DOUBLER AND INSTALLED IAW SRM 53-41-14 PARA 5A FIG201 REPAIR PRINCIPLE 5.SDR CALA2016101995816Door Sill · corrodedCORROSION AT R1 DOOR SILL FWD GIRT BAR HOLES AT FR 16, STR 23 AND AFT GIRT BAR HOLES AT FR 20, STR 23. REPAIRED IAW SRM 53-11-14 FIG 108.SDR CALA2016101795812Door Frame · corrodedAFT FUSE R2 DOOR CUTOUT FR68 AT STR 23R FRAME HAS CORROSION. CUTOUT DAMAGE & INSTALLED REPAIR IAW SRM53-41-12 FIG 202.SDR CALA2016101795810Skin · dentedSKIN DENT AT FRAME 23 BELOW STR 22L. REMOVED DAMAGE AND INSTALLED DOUBLER REPAIR PER SRM 53-11-11 FIG 210.SDR CALA2016101795809Skin · dentedFUSELAGE SKIN RT DENT FOUND OUT OF LIMITS AT FR1-FR2 28+WL. REMOVED DAMAGE AND REPAIRED IAW SRM 53-00-11-PH4S FIG 230.SDR CALA2016101795808Skin · damagedRT WING 640 RB FUEL ACCESS LANDING AFT FLANGE THIRD HOLE INBD FROM CENTER LINE HAS A ELONGATED HOLE. REAMED HOLE AND FABRICATED REPAIR BUSHING AND INSTALLED IAW SRM 57-21-11 FIG 203 SRI57-21-11-2-003-00 TABLE 204
Back to Airbus A319-131