duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320212' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320212' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2015042502927Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM +Y512 BETWEEN FR 64 TO FR 67+10" AT AFT GALLEY AREA L=2", W=1", D=0.004". SSI 534147. REPLACED FLOORBEAM +Y512 BETWEE FR 64 TO FR 67+10" AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53472815.SDR DALA2016112209102Stringer · corrodedFOUND AREAS OF CORROSION COMMON TO STRINGER 43L. ALL DAMAGE IS FOUND BETWEEN FRAMES 56-57. THE DAMAGED STRINGER SECTION WAS REMOVED AND A SPLICE REPAIR INSTALLED IAW ER/A.SDR DALA2015042402926Stringer · corrodedDURING INSPECTION, FOUND CORRSION FOUND AT STRINGER 43 LT FRAME 56 TO 57. REMOVED FASTENERS IAW SRM 51-42-11, 500123, COMPLETED BHEC OF FASTENER HOLES IAW NDTM 51-00-00 PART 6, NO CRACKS FOUND. 270158. FABRICATED STRINGER SPLICE AND COUPLING IAW SRM 53-00-1SDR DALA2015042402925Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM -Y 189 AT FWD GALLEY AREA BETWEEN FRAME 20 TO FRAME 23. L=1.250", W=0.900", D=0.003", MEASURES APRROXIMATELY SSI 531189. REPLACED FLOORBEAM -Y189 AT FWD GALLEY AREA BETWEEN FRAME 20 TO FRAME 23 IAW SRM 51-72-11SDR DALA2015042402924Web · corrodedDURING INSPECTION, FOUND CORROSION ON WEB AT AFT GALLEY AREA FROM FRAME 69 TO FRAME 70 AND STR 23R, L=2", W=1", D=0.002". SSI 534147. REPLACED WEB AT AFT GALLEY AREA FROM FRAME 69 TO FRAME 70 AND STR 23R IAW SRM 51-72-11 AND DWG D53470100.SDR DALA2015042402906Power Supply · inoperativeDURING NON ROUTINE CHECK, FOUND AFT CABIN EPSU 13WL IS INOPERATIVE. REPLACED EPSU 13WL AND OPS CHECK WAS GOOD.SDR DALA2015042402905Stringer Splice · corrodedDURING INSPECTION, FOUND CORROSION ON SPLICE AT AFT GALLEY AREA ON STR 30R ON FRAME 67, L=0.300", W=0.250", D=0.008". MEASURES APPROXIMATELY, SSI 534144. REPLACED SPLICE AT AFT GALLEY AREA ON STRINGER 30R AND FRAME 67 IAW SRM 51-72-11 AND DWG D53480020 ANSDR DALA2015042402904Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM -Y310 BETWEEN FR 65 TO FR 67 AT AFT GALLEY AREA L=5", W=3", D=0.003". SSI 534147. REPLACED FLOORBEAM -Y318 BETWEEN FR 65 TO FR 67 AT AFT GALLEY AREA IAW SRM 51-72-11 DWG D53472305.SDR DALA2015042302901Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM -Y1292 AT FWD GALLEY AREA FROM FRAME 12 TO FRAME 24, L=0.178", W=0.055", D=0.001". SSI 531189. REPLACED FLOORBEAM -Y1292 LOCATED BETWEEN FR 12 TO FR 24 SRM 51-72-11 AND DWS D53112812, D53110984 , D5311SDR DALA2015042302900Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM -Y81 AT FWD GALLEY AREA FROM FRAME 12 TO FRAME 16, L=0.381", W=0.160", D=0.001". SSI 531189. REPLACED FLOORBEAM -Y81 AT FWD GALLEY AREA FROM FRAME 12 TO FRAME 16 AND FASTENERS IAW SRM 51-72-11 AND DWG D5311SDR DALA2015042302899Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM -Y765 AT FWD GALLEY AREA FROM FRAME 12 TO FRAME 24, L=1.375", W=0.810", D=0.002". SSI 531189. REPLACED FLOORBEAM -Y765 LOCATED AT FWD GALLEY AREA FROM FR 12 TO FR 24 IAW SRM 51-72-11 AND DWG D53110422.SDR DALA2015042302898Seat Track · corrodedDURING INSPECTION, FOUND CORROSION ON SEAT TRACK -Y765, FRAME 47 TO 64 EVALUATED AND FOUND LIMITS ON JC 2500- 2032-DE IN PASSENGER CABIN. P1, FR 49=3.785", W=0.350", D=0.063", P2 FR.53+12", L=2.603", W=0.348", D=0.043, "P3 FR .62+10", L=4.100", W=0.350", D=0.SDR DALA2015042302897Stringer Splice · corrodedDURING INSPECTION, FOUND CORROSION ON SPLICE AT AFT GALLEY ARA ON STR 29L ON FRAME 67 L=0.540", W=0.100", D=0.002", MEASURES APPROXIMATELY, SSI 534144. REPLACED SPLICE AT AFT GALLEY AREA ON STR 29L ON FRAME 67L IAW SRM 51-72-11 AND DWG D53480020.SDR DALA2015042302896Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM -465 AT AFT GALLEY AREA FROM FRAME 64 TO FRAME 67, L=1.5", W=0.500", D=0.002", SSI 534147. REPLACED FLOORBEAM -Y465 AT AFT GALLEY AREA FROM FR 64 TO FR 67+ 5" IAW SRM 51-72-11 DWG D53472000.SDR DALA2015042302893Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM -Y765 AT AFT GALLEY AREA FROM FRAME 64 TO FRAME 66, L=5", W=3", D=0.005". REPLACED FLOORBEAM -Y765 LOCATED BETWEEN FR 64 TO FR 66 IAW SRM 51-72-11 AND DWG D53472816, D53472000.SDR DALA2015042302892Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM +Y765 BETWEEN FR 66+5" AND FR 70 AT AFT GALLEY AREA L=2", W=1", D=0.033", SSI 534147. REPLACED FLOORBEAM +Y765 BETWEEN FR 66+5" AND FR 70 AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53472000.SDR DALA2015042302891Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM -1292 AT AFT GALLEY AREA FROM FRAME 64 TO FRAME 66, L=1", W=0.500", D=0.003". SSI 534147. REPLACED FLOORBEAM Y1292 LOCATED AT AFT GALLEY AREA FRAME 64 TO FRAME 66 IAW SRM 51-72-11 AND DWG D53472000.SDR DALA2015042302890Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM -Y1162 AT AFT GALLEY AREA FROM FRAME 68 TO FRAME 69 L=2", W=1", D=0.004". SSI 534147. REPLACED FLOORBEAM -Y1162 LOCATED AFT GALLEY AREA FROM FRAME 68 TO FRAME 69 RT IAW SRM 51-72-11 AND DWG D53472800.SDR DALA2015042302889Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM -Y1225 AT AFT GALLEY AREA FROM FRAME 66 TO FRAME 68, L=2"; W=1"; D=0.003". D=0.003". SSI 534147. REPLACED FLOORBEAM -Y1225 LOCATED AT AFT GALLEY FROM FRAME 66 TO FR 68 IAW SRM 51-72-11 AND DWG D53472800.SDR DALA2015042302888Fitting · corrodedDURING INSPECTION, FOUND CORROSION ON CENTER FITTING AT FWD GALLEY AREA FROM FRAME 16 TO FRAME 20 AND STRINGER 23R, L=0.255", W=0.180", D=0.002". SSI 531189. REPLACED NEW CENTER FITTING LOCATED FR 16 TO FR 20 AND STR 23R IAW SRM 51-72-11 AND DWG D53112225.SDR DALA2015042302887Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM +Y254 AT FWD GALLEY AREA FROM FRAME 12 TO FRAME 24 L=1.310"; W=0.360"; D=0.002". SSI 531189, REPLACED FLOORBEAM +Y254 LOCATED BETWEEN FR 12 TO FR 24 IAW SRM 51-72-11 AND DWGS D53112816, D53110422, D53110984.SDR DALA2015042302886Fitting · corrodedDURING INSPECTION, FOUND CORROSION ON CORNER FITTING FRAME 68 AT STR 23R AT AFT GALLEY AREA, L=0.700", W=0.300", D=0.003". SSI 534147, REPLACED CORNER FITTING AND FASTENERS LOCATED FR 68 AT STR 23R AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53480505.SDR DALA2015042302885Fitting · corrodedDURING INSPECTION, FOUND CORROSION ON CORNER FITTING FRAME 68, LOCATED AT STR 23L AT AFT GALLEY AREA L=1", W=0.500", D=0.003, SSI 534147. REPLACED CORNER FITTING LOCATED ON FRAME 68 AT LEVEL STR 23L AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53480505.SDR DALA2015042302883Power Supply · inoperativeDURING NON ROUTINE CHECK, FOUND EPSU 12WL IS INOPERATIVE. REPLACED EPSU 12WL AND OPS CHECK WAS NORMAL.SDR DALA2015042202882Seat Track · corrodedDURING INSPECTION, FOUND OUT LIMIT SEAT TRACK -Y1292 FLOOR STRUCTURE AFTER EVALUATION IAW AMDS 2500-2030 AT FWD GALLEY AREA FROM FRAME 20 TO FRAME 24, 3 EA, L=1.586 , W=0.376 , D=0.050. L=3.304, W=0.367, D=0.034, L=1.824, W=0.365, D=0.049". REPLACEDSDR DALA2015042202880Skin · corrodedDURING INSPECTION, FOUND CORROSION FOUND ON STRINGERS 42L AND 43L BETWEEN FRAMES 56 & 57 ALSO ON SKIN BETWEEN 42L AND 43L AND FRAMES 56 & 57. INSTALLED DOUBLER 165942. C/W ERA 535278-14 AD AND PRI 535278-14, REV O AND REV 1.SDR DALA2015042202879Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM LONGITUDINAL AT AFT GALLEY AREA FROM FRAMES 65 TO 66 AND STRINGER 23R L=3, W=1, D=0.003". SSI 534147. REPLACED FLOOR BEAM LONGITUDINAL AT AFT GALLEY AREA FROM FRAME 65 TO FRAME 66 AT LEVEL STR 23R IAW SRM 51SDR DALA2015042202878Stringer · corrodedDURING INSPECTION, FOUND STRINGER 42L HAS CORROSION ON IT BETWEEN FRAMES 56-57. REPLACED STRINGER 42L IAW SRM 53-00-13.SDR DALA2015042202877Access Panel · corrodedDURING INSPECTION, FOUND CORROSION ON ACCESS PANEL 540JB ON COUNTERSINK HOLE IN LT FUEL TANK. REPLACED ACCESS PANEL.SDR DALA2015042202876Access Panel · corrodedDURING INSPECTION, FOUND CORROSION ON ACCESS PANEL 540QB COUNTERSINK HOLE IN LT FUEL TANK. REPLACED ACCESS PANEL 540QB.SDR DALA2015042202875Access Panel · corrodedDURING INSPECTION, FOUND CORROSION ON ACCESS PANEL 540PB COUNTERSINK HOLE IN LT FUEL TANK. REPLACED ACCESS PANEL 540PB IAW AMDS CARD 5730-6014.SDR DALA2015042202874Seat Track · corrodedDURING INSPECTION, FOUND CORROSION ON SEAT TRACK +Y765 FRAMES 47 TO 64 AND FOUND OUT LIMITS. REPLACED THE SEAT TRACK IAW SRM 51-72-11 AND DWG D53472000.SDR DALA2015042202873Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOOR SUPPORT -Y765 AT AFT GALLEY AREA FROM FRAMES 64 TO 66. REPLACED FLOOR SUPPORT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53472230.SDR DALA2015042202872Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOOR SUPPORT -Y765 AT AFT GALLEY AREA FORM FRAMES 66 TO 70REPLACED FLOOR SUPPORT -Y765 AT AFT GALLEY AREA FROM FRAME 66 TO FRAME 70 IAW SRM 51-72-11 AND DWG D53472000.SDR DALA2015042202871Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM +Y765 BETWEEN FRAMES 64 AND 66+5" AT AFT GALLEY AREA L=3", W=2", D=0.004", SSI 534147. REPLACED FLOORBEAM +Y765 BETWEEN FRAME 64 AND FRAME 66+5" AT AFT GALLEY AREA IAW SRM 51-72-11.SDR DALA2015042202870Floorbeam · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM LOCATED BETWEEN +Y254 TO +Y180 AT AFT GALLEY AREA L=0.500", W=0.300", D=0.002", SSI 534147. REPLACED FLOORBEAM LOCATED BETWEEN +Y254 TO +Y180 AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53472000.SDR DALA2015042102840Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM +Y765 BETWEEN. FR 66+5" AND FR 70 AT AFT GALLEY AREA L=0.700", W=0.400", D=0.004". SSI 534147. REPLACED FLOORBEAM +Y765 LOCATED BETWEEN FR 66+5" TO FR 70 AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53472800.SDR DALA2015042102839Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM +Y765 AT FWD GALLEY AREA FROM FRAME 12 TO FRAME 24, L=0.987", W=0.675", D=0.002", APPROX SSI 531189. REPLACED FLOORBEAM +Y765 AT FWD GALLEY AREA FROM FRAME 12 TO FRAME 24 IAW SRM 51-72-11 AND DWG D53112812 AND SDR DALA2015042102838Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM +Y512 BETWEEN FR 64 AND FR 70 AT AFT GALLEY AREA L=4", W=3", D=0.004". SSI 534147. REPLACED FLOORBEAM Y512 BETWEEN FR 64 AND FR 70 AFT GALLEY AREA IAW SRM 51-72-11 DWG D53472000.SDR DALA2015042102843Fitting · corrodedDURING INSPECTION, FOUND CORROSION ON CENTER FITTING AT FWD GALLEY AREA ON STRINGER 23R BETWEEN FRAME 16 TO FRAME 20, L=0.300", W=0.150", D=0.003". MEASURES APPROXIMATELY, SSI 531189. REPLACED CENTER FITTING AT FWD GALLEY AREA ON STR 23R BETWEEN FRAME 16 TSDR DALA2015042102842Fitting · corrodedDURING INSPECTION, FOUND CORROSION ON CORNER FITTING FRAME 20 AT FWD GALLEY AREA ON STRINGER 23L, L=0.200", W=0.100", D=0.004". MEASURES APPROXIMATELY SSI 531189. REPLACED CORNER FITTING FRAME 20 AT FWD GALLEY AREA ON STR 23L IAW SRM 51-72-11 AND DWG D5311222SDR DALA2015042102841Fitting · corrodedDURING INSPECTION, FOUND CORROSION ON CENTER FITTING AT FWD GALLEY AREA ON STR 23L BETWEEN FRAME 16 TO FRAME 20. L=0.200", W=0.150", D=0.003". MEASURES APPROXIMATELY, SSI 531189. REPLACED CENTER FITTING AT FWD GALLEY AREA ON STR 23L BETWEEN FRAME 16 TO FRASDR DALA2015042002837Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM -Y765 BETWEEN FR 66+5" AND FR 70 AT AFT GALLEY AREA, L=0.500", W=0.250", D=0.004". SSI 534147. REPLACED IAW SRM 51-72-11 AND DWG D53472816.SDR DALA2015042002836Seat Track · corrodedDURING INSPECTION, FOUND CORROSION ON SEAT TRACK, -Y1292, FRAME 47 TO 64 EVALUATED AND FOUND OUT LIMIT ON JC 2500-203 2-DE IN PASSENGER CABIN. P1 FR47+13", L=2.896", W=0.356", D=0.060", P2 FR52 L=4.227", W=0.358", D= 0.065", P3 FR57+4", L=3.345", W=0.350", D=SDR DALA2016112209104Seat Track · corrodedCORROSION ON SEAT TRACK +Y765, FRAMES 41 - 47. REPLACED THE SEAT TRACK.SDR DALA2015041902807Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM -Y465 AT AFT GALLEY AREA FROM FRAME 64 TO FRAME 67, L=4"; W=2"; D=0.009". SSI 534147. REPLACED FLOORBEAM -Y465 AND FASTENERS LOCATED BETWEEN FR 64 TO FR 67 IAW SRM 51-72-11 AND DWG D53472816.SDR DALA2015041902806Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM +Y1292 AT FWD GALLEY AREA FROM FRAME 12 TO FR AME 24, L=0.895, W=0.679, D=0.002. APPROXIMATELY SSI 531189. REPLACED FLOOR BEAM +Y1292 AT FWD GALLEY AREA FROM FRAME 12 TO FRAME 24 SRM 51-72-11 AND DWG D53112812SDR DALA2015041802805Web · corrodedDURING INSPECTION, FOUND CORROSION ON WEB FRAME 20 -Y1732 AT FWD GALLEY AREA L=0.895 W=0.658, D=0.002. APROXIMATELY SSI531189. REPLACED WEB LOCATED ON FR 20 -Y1732 AT FWD GALLEY AREA IAW SRM 51-72-11 AND DWG D53112783.SDR DALA2015041802804Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM -Y 81 AT FWD GALLEY AREA BETWEEN FRAME 12 TO FRAME 16. L=1.500", W=1.000", D=0.003". MEASURES APPROXIMATELY. REPLACED FLOORBEAM -Y81 AT FWD GALLEY AREA BETWEEN FRAME 12 TO FRAME 16 IAW SRM 51-72-11 AND DWG D5SDR DALA2015041702802Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM Y 503 AT FWD GALLEY AREA BETWEEN FRAME 12 TO FRAME 16. L=3.000", W=2.000", D=0.004". MEASURES APPROXIMATELY. REPLACED FLOORBEAM Y503 AT FWD GALLEY AREA BETWEEN FRAME 12 TO FRAME 16 IAW SRM 51-72-11 AND D531128
Back to Airbus A320-212