What was found
DURING INSPECTION, FOUND OUT LIMIT SEAT TRACK -Y1292 FLOOR STRUCTURE AFTER EVALUATION IAW AMDS 2500-2030 AT FWD GALLEY AREA FROM FRAME 20 TO FRAME 24, 3 EA, L=1.586 , W=0.376 , D=0.050. L=3.304, W=0.367, D=0.034, L=1.824, W=0.365, D=0.049". REPLACED SEAT TRACK -Y1292 AT FWD GALLEY AREA FROM FRAME 12 TO FRAME 24 IAW SRM 51-72-11 AND DWGS D53110422 AND D53112812.