SDR DALA2020120703983Stop Fitting · crackedCRACK INDICATION ON FRAME 68 DOOR STOP 1 LT SIDE AT OPEN FASTENER HOLE 2. AA 5311-01216, AD RELATED. CORRECTIVE ACTION: PERFORMED REPAIR ON HOLE 2 FRAME 68 DOOR STOP 1 LT, AS PER A320 SRM 53-41-12-300-008 AND 53-41-12-300-010.SDR DALA2020120703982Stop Fitting · crackedCRACK INDICATION ON FRAME 66 DOOR STOP FITTING NR 7 LT SIDE AT OPEN FASTENER HOLE 2. AA 5311-01216, AD RELATED. CORRECTIVE ACTION: REPAIRED HOLE NR 2 ON DOOR STOP FITTING NR 7 ON FRAME 66 LT SIDE, AS PER SRM A320 53-41-12-300-008 AND 53-41-12-300-010.SDR DALA2020120703981Stop Fitting · crackedCRACK INDICATION ON FRAME 68 DOOR STOP 1 RT SIDE AT OPEN FASTENER HOLE 4. AA 5311-01216, AD RELATED. CORRECTIVE ACTION: PERFORMED REPAIR ON HOLE NR 4 FRAME 68 DOOR STOP 1 RT, AS PER A320 SRM 53-41-12-300-008 AND 53-41-12-300-010.SDR DALA2020120703980Stop Fitting · crackedCRACK INDICATION ON FRAME 68 DOOR STOP 1 LT SIDE AT OPEN FASTENER HOLE 4. AA 5311-01216, AD RELATED. CORRECTIVE ACTION: PERFORMED REPAIR ON HOLE 4 FRAME 68 DOOR STOP NR 1 LT, AS PER A320 SRM 53-41-12-300-008 AND 53-41-12-300-010.SDR DALA2020120403968Oxygen Mask · unwanted deployOXYGEN PANEL MASK DEPLOYED/LOCATIONS: 607. CORRECTIVE ACTION: RESECURED MASK INTO PANEL AND CLOSED AND SECURED PSU DOOR. OK FOR SERVICE.SDR DALA2020120303957Floorbeam · corrodedCORROSION ON FLOOR BEAM +Y1292 AT LEVEL OF FR 16 AT FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM +Y1292 AT LEVEL OF FR 16 AT FWD GALLEY AREA. OK FOR SERVICE.SDR DALA2020120203943Dummy Rail · corrodedCORROSION ON DUMMY RAIL AT Y503.2 BETWEEN FR 12 TO FR 16 FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED DUMMY RAIL AT Y503.2 BETWEEN FR 12 TO FR 16 FWD GALLEY AREA. OK FOR SERVICE.SDR DALA2020120103931Hook · wornWEAR ON HOOK ON THE INNER CONTROL HANDLE PASSENGER CREW DOOR 831. CORRECTIVE ACTION: REPLACED HOOK. OK FOR SERVICE.SDR DALA2020120103930Compensator · out of adjustPASSENGER CREW DOOR 831 ON THE BELL CRANK OF THE COMPENSATION MECHANISM OUT OF ADJUSTEMENT. CORRECTIVE ACTION: PERFORMED ADJUSTMENT. OK FOR SERVICE.SDR DALA2020120103929Roller · wornWORN ROLLER ON PASSENGER CREW DOOR 831 AFT LOWER POSITION. CORRECTIVE ACTION: REPLACED ROLLER. OK FOR SERVICE.SDR DALA2020120103928Bushing · excess playEXCESSIVE PLAY IN PASSENGER CREW DOOR 842 ON BUSHINGS OF UPPER CONNECTION LINK. CORRECTIVE ACTION: REPLACED BUSHINGS. OK FOR SERVICE.SDR DALA2020120203944Transmitter · malfunctionedIRF STATES DOOR RT FWD CABIN ECAM DIF PRESSURE NORMAL IRO MESSAGE. CORRECTIVE ACTION: CLEANED R1 DOOR SENSOR. R1 DOOR INDICATION OPERATES NORMAL.SDR DALA2020113003900Dampener · no testDAMPER DOES NOT PASS TEST AT PASSENGER CREW DOOR 842. CORRECTIVE ACTION: REPLACED DAMPER AT PASSENGER CREW DOOR 842. OK FOR SERVICE.SDR DALA2020113003903Panel · inoperativeFOUND PSU OXY PANEL 15ABC DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU OXY PANEL 15ABC. OK FOR SERVICE.SDR DALA2020112703889Panel · no testFOUND PSU OXY PANEL 30 ABC DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU OXY PANEL 30 ABC. OK FOR SERVICE.SDR DALA2020112703888Panel · no testFOUND PSU OXY PANEL 26ABC DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU OXY PANEL 26ABC. OK FOR SERVICE.SDR DALA2020112703887Panel · no testFOUND PSU OXY PANEL 23ABC DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU OXY PANEL 23ABC. OK FOR SERVICE.SDR DALA2020113003901Dampener · no testPASSENGER CREW DOOR 832 WONT PASS DAMPER TEST. CORRECTIVE ACTION: REPLACED DAMPER AT PASSENGER CREW DOOR 832 AT AFT GALLEY AREA. OK FOR SERVICE.SDR DALA2020122304203Damper · no testPASSENGER CREW DOOR 841 FWD GALLEY AREA DAMPER FAILED TEST. CORRECTIVE ACTION: REPLACED DAMPER, OK FOR SERVICE.SDR DALA2020120403967Damper · no testCREW DOOR DAMPER AT DOOR 831 AT FWD GALLEY AREA FAILED TEST. CORRECTIVE ACTION: REPLACED DOOR DAMPER AT DOOR 831 FWD GALLEY AREA. OK FOR SERVICE.SDR DALA2020120103926Damper · no testPASSENGER CREW DOOR DAMPER 841 DOESN'T PASS TEST. CORRECTIVE ACTION: REPLACED DOOR 841 DAMPER. OK FOR SERVICE.SDR DALA2020112703886Frame · damagedBOLT HOLES NEEDED COLD WORKING ( 2EA) HOLE LOCATED ON FRAME 36 RT SIDE INTERFACING LONGITUDINAL BEAM AND PRESSURE PANEL. CORRECTIVE ACTION: PERFORMED COLD EXPANSION IN OPEN (2 EA) HOLE LOCATED ON FRAME 36 RT SIDE INTERFACING LONGITUDINAL BEAM AND PRESSURE PANSDR DALA2020112703885Frame · damagedBOLT HOLES (2 EA) NEEDED TO BE COLD WORKED AT FRAME 36 LT SIDE INTERFACING LONGITUDINAL BEAM AND PRESSURE PANEL. CORRECTIVE ACTION: COLD WORKED BOLT HOLES AT FRAME 36 LT SIDE INTERFACING LONGITUDINAL BEAM AND PRESSURE PANEL. OK FOR SERVICE.SDR DALA2020112703884Roller · deterioratedFOUND DETERIORATED PASSENGER CREW DOOR 831 LOWER GUIDE ROLLERS FWD AND AFT POSITIONS. CORRECTIVE ACTION: REPLACED LOWER GUIDE ROLLERS FWD AND AFT POSITIONS AT DOOR 831. OK FOR SERVICE.SDR DALA2020112703883Door · out of adjustPASSENGER CREW DOOR 831 OUT OF ADJUSTMENT. CORRECTIVE ACTION: PERFORMED ADJUSTMENT ON PASSENGER CREW DOOR NUMBER 831. OK FOR SERVICE.SDR DALA2020112703882Torsion Bar · out of adjustOUT OF ADJUSTMENT TORSION BAR BELLCRANK PASSENGER CREW DOOR 832. CORRECTIVE ACTION: PERFORMED ADJUSTMENT OF RIGGING POINT OF TORSION BAR BELLCRANK OF PASSENGER/CREW DOOR 832 AT AFT GALLEY.SDR DALA2020112703881Door · out of rigPASSENGER CREW DOOR 841 WAS OUT OF RIG. CORRECTIVE ACTION: PERFORMED ADJ OF PASSENGER CREW DOOR 841. OK FOR SERVICE.SDR DALA2020113003902Dampener · no testCREW DOOR 842 DAMPER DOES NOT PASS TEST. CORRECTIVE ACTION: REPLACED DOOR DAMPER. OK FOR SERVICE.SDR DALA2020112403854Roller · deterioratedDETERIORATED ROLLER PASSENGER CREW DOOR 842 FWD AND AFT LOWER POSITIONS. CORRECTIVE ACTION: REPLACED ROLLER PASSENGER CREW DOOR FWD AND AFT LOWER POSITIONS AT AFT GALLEY AREA DOOR 842. OK FOR SERVICE.SDR DALA2020112403853Roller · deterioratedDETERIORATED ROLLER PASSENGER CREW DOOR 832 FWD AND AFT LOWER POSITION. CORRECTIVE ACTION: REPLACED ROLLERS ON PASSENGER CREW DOOR 832 FWD AND AFT LOWER POSITIONS AT AFT GALLEY AREA. OK FOR SERVICE.SDR DALA2020112303832Oxygen Mask · unwanted deployO2 MASK OVER 2AB FELL OPEN ON TAXI IN. CORRECTIVE ACTION: RESTOWED O2 MASK OVER 2AB. OK FOR SERVICE.SDR DALA2020112303831Oxygen Mask · unwanted deployPASS O2 MASK ON ROW 25 A B C DROPPED. CORRECTIVE ACTION: STOWED MASKS AT ROW 25 A B C. A/C OK FOR SERVICE.SDR DALA2020112303821Roller · dirty1L DOOR VERY DIFFICULT TO OPEN FROM OUTSIDE. CORRECTIVE ACTION: CLEANED GUIDES AND ROLLERS AND APPLIED LIGHT COAT OF GREASE TO SAME. DOOR CHECKS GOOD.SDR DALA2020112303820Latch · brokenFOUND PSU LATCH BROKEN ON AFT LEFT LAV LAVATORY OXYGEN MODULE. CORRECTIVE ACTION: REMOVED AND REPLACED AFT LEFT LAV PSU OXYGEN MASK/ GENERATOR CONTAINER. OPERATIONS CHECKED GOOD.SDR DALA2020111903784Oxygen Mask · unwanted deployOXYGEN PANEL MASK DEPLOYED. CORRECTIVE ACTION: R & R F/C LAV EMERGENCY OXYGEN CONTAINER. OK FOR SERVICE.SDR DALA2021012000370Spar · corrodedCORROSION FOUND ON MATING SURFACES OF LT WING REAR SPAR (AFT SURFACE) COMMON TO RETRACTION JACK FITTING AROUND HOLE NR 80. CORRECTIVE ACTION: PERFORMED INSP WITH REPETETIVE INSP MON PUT IN PLACE. ER/A 588446-14AD REV ORIGINAL. OK FOR CONTINUED SERVICE.SDR DALA2021011900307Spar · corrodedCORROSION FOUND ON MATING SURFACES OF RT WING REAR SPAR (AFT SURFACE) COMMON TO RETRACTION JACK FITTING AROUND HOLES NR 58 AND NR 81. CORRECTIVE ACTION: COMPLIED WITH ER/A 588447-14AD REV ORIGINAL. OK TO CONTINUE TO MONITOR, JOB COMPLETE.SDR DALA2020111703762Strut · corrodedCORROSION INBOARD FLAP INTERCONNECT STRUTS ON LT WING (1 EA). CORRECTIVE ACTION: REPLACED INBOARD FLAP INTERCONNECT STRUTS ON LT WING (1 EA) (1657048).SDR DALA2020111703761Spar · corrodedCORROSION FOUND ON MATING SURFACES OF LT WING REAR SPAR (AFT SURFACE). CORRECTIVE ACTION: COMPLIED WITH ERA 588446-14AD (1656889).SDR DALA2021070203671Frame · crackedSHIP 3270 CRACK FRAME 35 CRACK FOUND AT HOLE B. CORRECTIVE ACTION: REPAIRED PER DELTA WORKCARD AMDS 5311-01171-04B. (1655853)SDR DALA2020111703765Door · unknownFLIGHT ATTENDANT AND GATE AGENT REPORT 1 L DOOR DIFFICULT TO OPEN. CORRECTIVE ACTION: 1 LEFT DOOR OPERATIONS CHECK GOOD. (9393040)SDR DALA2020111703764Smoke Detector · false activationAT CRUISE SMOKE LAVATORY SMOKE, FWD LEFT LAV A, WENT OUT AFTER 2 SECONDS. NO SMOKE OR FIRE. CORRECTIVE ACTION: PERFORMED OPERATIONAL TEST OF LAV SMOKE DETECTION SYSTEM, REF A320 AMM 26-17. OPERATIONS CHECKS GOOD. OK FOR SERVICE. (6462682)SDR DALA2020111703763Attach Bracket · damagedUPON REMOVAL OF RIGHT WING OUTBOARD AILERON SERVO FOUND TOOLING MARKS INBOARD FACE OF ATTACH BRACKET. CORRECTIVE ACTION: COMPLIED WITH PRI 588548-15 REV D. C/W ERA 588541-14 ORGINAL VERSION. (7102411).SDR DALA2021070203670Pressure Panel · crackedSHIP 3270 CRACK INDICATION ON INTERNAL STRUCTURE PRESSURE PANEL 3 E/A RH SIDE IN FWD CARGO COMPARTMENT. CORRECTIVE ACTION: REPAIRED PER DELTA WORKCARD AMDS 5311-01171-04B. (1654226)SDR DALA2021070203669Pressure Panel · crackedSHIP 3270 CRACK INDICATION ON INTERNAL STRUCTURE 3 E/A ON PRESSURE PANEL LH SIDE IN FWD CARGO COMPARTMENT. CORRECTIVE ACTION: REPAIRED PER DELTA WORKCARD 5311-01171-04A. (1654224)SDR DALA2020111603732Warning Message · false activationATO AT 70 KTS DUE TO A FWD AVIONICS DOOR OPEN INDICATION. DOOR WAS VERIFIED CLOSED AND LOCKED BY MAINTENANCE. CORRECTIVE ACTION: PLACED AVIONICS DOOR INDICATION ON MEL.SDR DALA2020111603725Door · out of adjustOUT OF ADJUSTMENT PASSENGER CREW DOOR 842 RIGGING POINTS UP POSITION ON THE BELLCRANK OF THE COMPENSATION MECHANISM AT AFT GALLEY AREA. CORRECTIVE ACTION: PERFORMED ADJUSTMENT OF PASSENGER CREW DOOR 842 RIGGING POINT UP POSITION ON THE BELLCRANK OF THE COMPENSDR DALA2020111103683Smoke Detector · false activationIN A CLIMB FROM 33000 TO 35000 MSO THE ECAM SHOWED SMOKE LAV SMOKE. THE WARNING EXTINGUISHED AFTER ABOUT 5 SECONDS. CORRECTIVE ACTION: ALL LAVS NO EVIDENCE OF SMOKE OR TAMPERING, PER A320 AMM 38-30. A/C OK FOR SERVICE.SDR DALA2020111103682Warning Message · false activationECAM DR PAGE IND PASSENGER DOORS/CABIN EMERGENCY EXIT, OPEN IND. CORRECTIVE ACTION: T/S PER TSM 52-13-00-810-804-A. NOTE ALL FAULTS AND FINDINGS.SDR DALA2020110603619Pin · detachedNR 2 RT DOOR DISARM PIN DETACHED. CORRECTIVE ACTION: REATTACHED NR 2 RT DOOR DISARM PIN, REF A320 AMM 52-13. OK FOR SERVICE.
Back to Airbus A320-212