What was found
BOLT HOLES (2 EA) NEEDED TO BE COLD WORKED AT FRAME 36 LT SIDE INTERFACING LONGITUDINAL BEAM AND PRESSURE PANEL. CORRECTIVE ACTION: COLD WORKED BOLT HOLES AT FRAME 36 LT SIDE INTERFACING LONGITUDINAL BEAM AND PRESSURE PANEL. OK FOR SERVICE.