SDR WX0A2018082973368Oil System · low pressureECAM ILLUMINATED FOR THE NR 2 ENGINE OIL PRESSURE LOW, ENGINE SHUTDOWN. REMOVED AND REPLACED THE NR 2 ENGINE.SDR ASAA2018110826758Shear Plate · corrodedRIGHT HAND AFT WET AREA FLOOR STRUCTURE-SHEAR PLATE FR69-FR70 HAS CORROSION. GROUNDED - YES. REMOVED AND REPLACED FRAME SUPPORT IAW A320 SRM 51-42-11.SDR F3LA2018082800415Unknown · odorPILOT REPORTED A WET SOCK ODOR IN THE ACFT WHEN FIRST WALKED ON, BURNING EYES. MAINTENANCE PERFORMED TSM 05-50-00-810-831-A. PERFORMED APU INSPECTION IAW AMM 49-00-81-810-874-A,
HYDRAULIC SYS INSPECTION IAW AMM 29-00-00-790-001-A, AND INSPECTED PACKS 1 & 2 SDR AALA2018100919007Support · corrodedCORROSION FOUND ON SUPPORT, FRAME 66 TO 68, STRINGER 23R. REPLACED THE SUPPORT IAW SRM 51-72-11, 51-42-11, AND DRAWING D53480505.SDR AALA201810089036Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE. CRACKED SHEAR PLATE BETWEEN FR 69 AND FR 70 AT S23L. REPLACED SHEAR PLATE PER SRM 51-72-11 AND 51-42-11.SDR AALA2018100819006Tray · crackedCRACKED TRAY BETWEEN FRAMES 68 TO 69, STRINGER 23L. REPLACED THE TRAY IAW SRM 51-72-11, 51-42-11, AND DRAWING D53480019.SDR AALA201808289001Button · faultyDURING CRUISE, THE CENTER TANK PUMP NR 2 FAULT MESSAGE DISPLAYED. REPLACED CENTER TANK NR 2 PUMP PUSH BUTTON IAW ESPM 20-45-11. OPS CHECKED GOOD.SDR AALA2018100819005Fitting · crackedCRACKED INTERCOSTAL FITTING AT FRAME 20, RIGHT SIDE AT THE NR 7 DOOR STOP FITTING. REPLACED THE INTERCOSTAL FITTING IAW SRM 51-72-11 AND 51-42-11.SDR AALA2018100219018Fitting · crackedCRACKED INTERCOSTAL FITTING AT FRAME 16, NR 7 DOOR STOP FITTING. REPLACED THE INTERCOSTAL FITTING IAW SRM 51-72-11.SDR AALA2018100219017Fitting · crackedCRACKED INTERCOSTAL FITTING AT FRAME 16, NR 7 DOOR STOP FITTING. REPLACED THE INTERCOSTAL FITTING IAW SRM 51-72-11.SDR AALA2018100219016Fitting · crackedCRACKED INTERCOSTAL FITTING AT FRAME 16, NR 7 DOOR STOP FITTING. REPLACED INTERCOSTAL FITTING IAW SRM 51-72-11 AND 51-42-11.SDR AALA201809289002Hinge Fitting · excess playEXCESSIVE PLAY ON THE AFT DOOR HINGE FITTING, NOSE LANDING GEAR DOOR. REPLACED THE AFT DOOR HINGE FITTING IAW CMM 52-82-32, AND SRM A320 51-72-11.SDR AALA201809289001Hinge Fitting · excess playEXCESSIVE PLAY FOUND ON THE FORWARD AFT DOOR HINGE FITTING ON THE NOSE LANDING GEAR DOOR. REPLACED THE HINGE FITTING IAW CMM 52-82-32, AND SRM 51-72-11.SDR AALA201809249005Hinge Fitting · excess playTHE AFT HINGE FITTING ON THE NOSE LANDING GEAR, RT DOOR WAS FOUND TO BE LOOSE AND HAVE EXCESSIVE PLAY. REPLACED THE HINGE FITTING IAW SRM 51-72-11, AND CMM 52-82-32.SDR AALA201809249004Hinge Fitting · excess playTHE FORWARD HINGE FITTING ON THE NOSE LANDING GEAR FORWARD RT DOOR WAS FOUND TO BE LOOSE AND HAVE EXCESSIVE PLAY. REPLACED THE HINGE FITTING IAW SRM 51-72-11, AND CMM 52-82-32-400-805.SDR AALA2018092179060Floor Panel · delaminatedDELAMINATION ON FLOOR PANEL 231LF. REPLACED THE FLOOR PANEL IAW SRM 53-02-00-300-011.SDR AALA201809189007Floor Panel · corrodedCORROSION FOUND ON FLOOR PANEL 222FF IN THE FORWARD GALLEY. REPLACED THE FLOOR PANEL IAW AMM 53-00-00.SDR AALA2018091879040Floor Panel · delaminatedDELAMINATION FOUND ON FLOOR PANEL 231KF. REPLACED THE FLOOR PANEL IAW SRM 53-02-00-300-011, AND IRM 9701, REV H.SDR AALA2018091879039Floor Panel · delaminatedDELAMINATION FOUND ON FLOOR PANEL 261BG. REPLACED THE FLOOR PANEL IAW SRM 53-02-00-300-011, AND IRM 9701, REV H.SDR AALA2018091879038Floor Panel · delaminatedDELAMINATION FOUND ON FLOOR PANEL 251WF. REPLACED THE FLOOR PANEL IAW SRM 53-02-00-300-011, AND IRM 9701, REV H.SDR AALA2018091439003Floor Panel · delaminatedCABIN FLOOR PANEL 252GF DELAMINATED. REPLACED THE FLOOR PANEL IAW SRM 53-02-00-300-011, AND IRM 9701, REV H.SDR AALA201809149017Floor Panel · delaminatedDELAMINATION FOUND ON FLOOR PANEL 231FF IN THE FORWARD GALLEY. REPLACED THE FLOOR PANEL IAW SRM 53-12-00-300-006, FIGURE 20106, AND IRM 9701, REVISION H.SDR AALA201809149016Floor Panel · delaminatedDELAMINATION FOUND ON FLOOR PANEL 231BF IN THE FORWARD GALLEY. REPLACED THE FLOOR PANEL IAW SRM 53-12-00-300-006, FIGURE 20106, AND IRM 9701, REVISION H.SDR AALA201809129004Floor Panel · delaminatedDELAMINATION FOUND ON FLOOR PANEL 261DF, FRAMES 66 TO 68, BETWEEN -Y765 TO Y765, IN THE AFT GALLEY. REPLACED THE FLOOR PANEL IAW AMM 53-00-00-400-801-A, AND SRM 51-72-11.SDR AALA2018090769002Floor Panel · delaminatedDELAMINATION ON FLOOR PANEL 261AG, FRAMES 64 TO 66, Y512.5 TO -Y464.5. REPLACED THE FLOOR PANEL IAW AMM 53-00-00-400-801-A, AND SRM 51-72-11.SDR AALA201809069003Floor Panel · delaminatedDELAMINATION FOUND ON FLOOR PANEL 262BG IN THE AFT GALLEY AREA. REPLACED THE FLOOR PANEL IAW AMM 53-00-00-400-801-A, AND SRM 51-72-11.SDR AALA201810089046Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE. FRONT WINDSHIELD FRAME CRACKED BETWEEN FR 1 AND FR 4 AND +Y675 AND -Y675. REPAIRED FRONT WINDSHIELD FRAME PER EA 284085.SDR AALA201810089037Skin · crackedAIRCRAFT IN BASE MAINTENANCE. FUSELAGE SKIN CRACKED AT FR 35 AND S30L. REPAIRED SKIN PER EA 284027.SDR F3LA2018082800411Unknown · unknownPILOT REPORTED AN UNCOMMANDED LATERAL YAW TO THE RIGHT AFTER TAKEOFF ROLL, SPEED OF 10 KTS. MAINTENANCE COMPLETED TROUBLESHOOTING IAW TSM 05-50-00-810-823-A. BOTH NLG TIRES DAMAGED AND REPLACED IAW AMM 32-41-12 PB 401. NR 1 MLG TIRE DAMAGED, REPLACED THE NSDR AALA201808249025Lens · missingAFT LEFT DOOR FRAME EMERGENCY LIGHT LENS MISSING. MAINTENANCE INSTALLED EMERGENCY LIGHT LENS IAW AMM 33-51-13 AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA201810089045Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE. CRACKED LATERAL WINDOW FRAME BETWEEN FR 4 AND FR 8. REPAIRED LATERAL WINDOW FRAME PER EA 284313.SDR AALA201810089041Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE. CRACKED LATERAL WINDOW FRAME BETWEEN FR 4 AND FR 8. REPAIRED LATERAL WINDOW FRAME PER EA 284314.SDR ASAA2018082225896Bleed Valve · openECAM BLEED PAGE INDICATES THE NR 2 ENGINE HP BLEED VALVE WAS OPEN DURING CRUISE, AT THE GATE WITH ENGINE OFF, ACFT GROUNDED.SDR ASAA2018082425894Regulator · unknownNR 1 A/C PACK REGULATOR FAULT. ACFT GROUNDED. PERFORMED A POWER UP TEST PER AMM 21-61-00. CHECKS GOOD & NO FAULTS NOTED.SDR AALA2018091879044Floor Panel · delaminatedDELAMINATION FOUND ON FLOOR PANEL 131AF. REPLACED THE FLOOR PANEL IAW SRM 53-02-00-300-011, AND IRM 9701, REV H.SDR AALA2018091879037Floor Panel · delaminatedDELAMINATION FOUND ON FLOOR PANEL 151AF. REPLACED THE FLOOR PANEL IAW SRM 53-02-00-300-011, AND IRM 9701, REV H.SDR AALA2018091879036Floor Panel · delaminatedDELAMINATION FOUND ON FLOOR PANEL 151DF. REPLACED THE FLOOR PANEL IAW SRM 53-02-00-300-011, AND IRM 9701, REV H.SDR AALA2018091879035Floor Panel · delaminatedDELAMINATION ON FLOOR PANEL 151LF, FRAMES 56 TO 58, BETWEEN Y765 TO -Y765, IN THE AFT CARGO BAY. REPLACED THE FLOOR PANEL IAW SRM 53-02-00-300-011, AND IRM 9701, REVISION H.SDR AALA2018091879034Floor Panel · delaminatedDELAMINATION ON FLOOR PANEL 151GF, BETWEEN FRAMES 53 TO 56. BETWEEN Y765 TO -Y765 IN THE AFT CARGO BAY. REPLACED THE FLOOR PANEL IAW SRM 53-02-00-300, AND IRM 9701, REVISION H.SDR AALA201808219014Lens · looseEMERGENCY LIGHT INOPERATIVE. SECURED THE LENS. OPS CHECKED GOOD, OK FOR SERVICE.SDR AALA2018082109036Cover · detachedR2 DOOR COVER FELL OFF. ATTACHED THE DOOR SLIDE COVER IAW AMM 25-62-50.SDR F3LA2018082000392Unknown · odorDIRTY SOCK ODOR DETECTED BY THE FLIGHT CREW AND FLIGHT ATTENDANTS. ORIGINATED IN AFT CABIN. THE ACFT WAS AT FL360. NO POWER CHANGE WAS MADE. PACK 2 WAS TURNED OFF AND THE ODOR DISAPATED, SUSPECT PACK 2 CONTAMINATION. AT TOP OF DESCENT, POWER REDUCTION, THSDR F3LA2018081600388Unknown · odorDURING FLIGHT, HAD A ODOR IN THE CABIN. NR 1 PACK 1 WASS SUSPECTED. FOLLOWED QRH AND VOL. II PROCEDURES. ODOR IN AFT GALLEY MOSTLY DESCRIBED AS A ROTTEN EGG AND ACETONE TYPE ODOR. THE ODOR LEANS TO THE NR 2 ENGINE AND NR 2 PACK. NR 2 ENGINE BORESCOPED. SDR AALA201808169015Lens · missingEMERGENCY LIGHT LENS MISSING. MAINTENANCE SECURED THE LENS AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA201808169014Lens · missingEMERGENCY LIGHT LENS MISSING. MAINTENANCE SECURED THE LENS AND PERFORMED A SATISFACTORY OPERATIONAL CHECK.SDR ASAA2018081625779Computer · failedVENT AVIONICS SYSTEM FAULT. ACFT GROUNDED. CONNECTED THE ISOLATION VALVE 24HQ, R & R AEVC COMP, 10HQ IAW AMM 21-26-34. OPS CHECKED GOOD.SDR AALA201808139029Bustle · damagedR2 DOOR SLIDE COVER DAMAGED. PROPERLY INSTALLED BUSTLE AS REQUIRED.SDR F3LA2018081400387Apu · odorDIRTY SOCK OR BURNING OIL ODOR NOTICED BY ALL CREW MEMEBERS WHEN BOARDING THE ACFT. ODOR NOTICED IN COCKPIT AND ENTIRE CABIN. BLEED CONFIGURATION, APU BLEED ON, NR 2 PACK ON, NR 1 PACK OFF. PERFORMED TSM 05-50-00-810-831-A. CAUSE INDICATED TO BE APU AND PSDR ASAA2018081315759Bleed Air Sys · malfunctionedAPU BLEED INOPERATIVE. ACFT GROUNDED. RESET THE APU BLEED SYSTEM IAW AMM 36-12-00, TESTED OK. OPS CHECKED GOOD. NO FAULTS FOUND.SDR AALA2018081439024Ecs · contaminatedDIRTY SOCK, LIGHT OIL ODOR WITH APU BLEEDS ON. ACCOMPLISHED CARD 26L00021002 FOR TROUBLESHOOTING AND 26L00021004 FOR DECONTAMINATION OF THE ENVIROMENTAL CONTROL SYSTEM. NO ODORS NOTED.