Airbus A320-214
Service difficulty reports · 10,616
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320214' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320214' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2018030823785Fcu · malfunctionedNR 1 FCU INOPERATIVE ACFT GROUNDED. RESET THE NR 1 FCU IAW AMM 22-81-00, OPS CHECKED OK. FAULT CLEARED.SDR DU4R20180313003Attach Fitting · gougedRIGHT OUTBOARD ELEVATOR ACTUATOR ATTACH FITTING GOUGED.SDR F3LA2018030700293Slide · failedL1 DOOR SLIDE FOUND BAD DURING AN EPSU TEST. REMOVED AND REPLACED THE DOOR SLIDE IAW AMM 25-62-44-PB401. OPS CHECKED GOOD.SDR F3LA2018051800339Skin · crackedFRAME 35, STRINGER 30L, OPEN HOLE INSPECTION IN THE SKIN REVEALED AFT LOWER HOLE WITH CRACK INDICATION. REPAIRED THE SKIN IAW SRM 51-43-00, 51-44-11, 51-42-11, 51-21-11, 51-75-12, 51-73-12, 51-24-00, 51-23-11, NTM 51-10-01, AMM 21-21-860-050-A, TDI SDR F3LA2018040900319Stringer · corrodedAFT CARGO STRINGER 32 AT FR 58 HAS CORROSION. REPAIRED THE STRINGER IAW EA 13597, SRM 53-21-13, 51-42-11, 51-10-01, AND 51-73-00.SDR ASAA2018030423753Control Unit · faultedFUEL STATUS MAINTENANCE MESSAGE. ACFT GROUNDED. FLSCU-1(7QJ) REMOVED AND REPLACED, SYSTEM TESTED OK IAW AMM 28-46-34.SDR ASAA201805184686Web · corrodedCORROSION FOUND ON THE R2 DOOR CUT OUT LOWER SILL, 50 INCHES FROM CENTERLINE, RIGHT SIDE 1 - 5 INCHES FORWARD OF FRAME 68. ACFT GROUNDED. PERFORMED A REPAIR IAW SRM 53-41-14-300-001. REPAIR PRINCIPLE 5.SDR AALA201803069037Fitting · crackedCRACK AT FASTENER HOLE ON MAIN LANDING GEAR DOOR LEFT ACTUATOR FITTING, AFT INBOARD KEEL BEAM ATTACH POINT FLANGE. REPAIRED THE FITTING IAW EA 278090.SDR AALA201803059006Flashlight · faultyAIRCRAFT WAS NOT GROUNDED. AFT FLIGHT ATTENDANT DIRECT VIEW FLASHLIGHT OPERATIVE BUT LED DOES NOT FLASH. REPLACED AFT FLIGHT ATTENDANT DIRECT VIEW FLASHLIGHT.SDR F3LA2018043000331Threshold · corrodedGIRT BAR FITTING ATTACH HOLES ON THRESHOLD ARE CORRODED AT THE R1 DOOR. REMOVED AND REPLACED R1 DOOR THRESHOLD IAW SRM 51-72-11, 51-42-11, 53-11-14, AND 51-44-11.SDR AALA201803069013Mechanism · lack of lubeL1 DOOR WOULD NOT SHOW ARMED, HANDLE WOULD NOT FLUSH WITH DOOR CLOSED AND LOCKED. MAINTENANCE CLEANED THE GIRT BAR LATCHES, LUBED MECHANISMS AND PERFORMED SATISFACTORY OPERATIONAL CHECK IAW AMM 25-62-00. AIRCRAFT WAS GROUNDED.SDR AALA201803059023Pin · corrodedRIGHT MAIN LANDING GEAR REAR PINTLE PIN. REPLACED PINTLE PIN IAW 26T00032001.SDR AALA201803059022Pin · corrodedLEFT MAIN LANDING GEAR REAR PINTLE PIN CORRODED. REPLACED THE PINTLE PIN IAW 26T00032001.SDR ASAA2018030123755Pcu · faultedSLAT SYS 2 FAULT. ACFT GROUNDED. REMOVED AND REPLACED SLAT SYS 2 PCU IAW AMM 27-84-51. SLAT PCU HOSE INSTALLED, DRIVESHAFT INSTALLED AND FINAL TORQUE ACCOMPLISHED IAW AMM 27-84-51 PB 401. BITE AND OPS TEST CUT OUT, NO FAULTS NOTED. NO LEAKS NOTED.SDR AALA201803029015Bustle · looseR2 DOOR ESCAPE SLIDE BUSTLE LOOSE. MAINTENANCE SECURED THE SLIDE BUSTLE AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR DU4R20180301002Door Sill · corrodedL2 DOOR SILL HAS CORROSION ON UPPER SURFACE AT FASTENER HOLE FRAME 68, STRINGER 23L.SDR DU4R20180301001Door Sill · corrodedR2 DOOR SILL FASTENER HOLE HAS CORROSION ON UPPER SURFACE FRAME 67 + 14, STRINGER 23R.SDR F3LA2018040300305Floorbeam · corrodedCABIN FLOORBEAM FWD WET AREA FRAME 16, -Y765, CORRODED. CLEANED AND EVALUATED THE AREA AND FOUND OUT OF LIMITS IAW SRM 53-11-14-283-004, LOCATED AND DRILLED NEW FLOORBEAM IAW SRM 51-42-11, TREATED AND PRIMED IAW SRM 51-21-11 AND INSTALLED THE FLOORBEAM ISDR F3LA2018040200303Floor Support · corrodedMAIN CABIN FLOOR SUPPORT, Y521.5, FRAMES 65 - 66 CORRODED. FOUND OUT OF LIMITS IAW SRM 53-00-14, REMOVED FOR REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11.SDR F3LA2018042600327Strap · corrodedFWD CARGO DOOR HAS CORROSION BELOW LOWER SILL. REMOVED AND REPLACED THE STRAP ON FWD CARGO LOWER DOOR SILL IAW SRM 51-72-11, SRM 53-21-29-283-001, SRM 51-42-11, AND SRM 51-44-11.SDR F3LA2018040300302Floorbeam · corrodedFLOORBEAM, Y1292 AT FRAME 66 CORRODED. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-72-11, AND SRM 53-00-14.SDR F3LA2018040300304Floorbeam · corrodedFLOORBEAM -Y765 AT FRAME 66 CORRODED. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-42-11.SDR F3LA2018040200300Floor Support · corrodedMAIN CABIN AFT WET AREA FLOOR SUPPORT -Y1292 AT FRAME 66 HAS CORROSION. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14. REMOVED AND REPLACED THE FLOOR SUPPORT FROM FRAMES 64 - 66 IAW SRM 51-44-11, AND 51-42-11.SDR ASAA2018022723710A/C Pack · malfunctionedAIR PACK 2 REGUL FAULT GROUNDED - YES. RESET PACK 2 AND PERFORMED OPS TEST PER AMM 21-61-00. TEST OK.SDR F3LA2018043000332Door Sill · corrodedL1 DOOR SILL, FRAMES 16 TO 20, CORRODED AROUND ATTACHMENT HOLES. REPAIRED THE DOOR SILL IAW SRM 53-11-14-283-005, SRM 51-21-11, 51-23-11, 51-42-11, NTM 51-10-01, AMM 52-11-21-000-001-A, AND 52-11-00-820-001-A.SDR F3LA2018042600330Floor Support · corrodedFWD CABIN FLOOR SUPPORT AT FRAME 14, Y503 HAS CORROSION ALONG ATTACHMENT HOLES. FOUND TO BE OUT OF LIMITS & REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-42-11, SRM 51-44-11, SRM 51-21-11 AND SRM 53-11-14 FROM FRAMES 14 TO 16.SDR F3LA2018041700325Floorbeam · corrodedL1 DOOR AREA AT FRAME 20, UPPER FLOORBEAM CORRODED AT Y1732. CLEANED & EVALUATED THE FLOORBEAM, FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14. REMOVED AND REPLACED THE DAMAGED FLOORBEAM IAW SRM 51-44-11, & 51-42-11.SDR F3LA2018040500312Floorbeam · corrodedRIGHT FWD CABIN AT FRAME 14 CENTER FLOORBEAM BETWEEN Y254 AND -Y254 CORRODED ON THE TOP SURFACE. BLENDED THE DAMAGED AREA, FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14, FIG 01. REMOVED AND REPLACED THE FLOORBEAM IAW 51-42-11.SDR F3LA2018040500313Floor Support · corrodedCABIN RT SIDE AT FRAME 14 BETWEEN Y254 AND -Y254, FLOOR SUPPORT HAS CORROSION. REMOVED AND REPLACED THE FLOOR SUPPORT FROM FRAMES 12 TO 16 IAW SRM 51-72-11, SRM 51-44-11, AND SRM 53-11--14-283-003.SDR F3LA2018040400314Floor Support · corrodedFWD CABIN FLOOR SUPPORT AT FRAME 14, Y765 HAS CORROSION ALONG THE ATTACHMENT HOLES. . REMOVED AND REPLACED THE FLOOR SUPPORT BETWEEN FRAMES 12 - 26 IAW SRM 51-72-11, SRM 53-11-14, AND SRM 51-21-11.SDR F3LA2018040400311Floorbeam · corrodedL1 DOOR AREA, AT FRAME 16 UPPER FLOORBEAM CORRODED AT Y1732. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-42-11, AND SRM 53-11-14.SDR F3LA2018042600329Floor Support · corrodedAFT WET AREA FLOOR SUPPORT Y765 WAS FOUND CORRODED AT FRAME 66. FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED THE FLOOR SUPPORT BETWEEN FRAMES 66-70 IAW SRM 51-72-11, 51-44-11, AND 53-41-14-283-001.SDR F3LA2018041600324Floor Support · corrodedAFT WET AREA FLOOR SUPPORT -Y1292 CORRODED BETWEEN FRAMES 68 - 69. REMOVED AND REPLACED THE FLOOR SUPPORT IAW 51-72-11, 51-74-00, AND 53-41-14-283-001.SDR F3LA2018040400310Floor Support · corrodedAFT WET AREA FLOOR SUPPORT CORRODED OTBD OF Y765, FRAME 66. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-42-11, AND SRM 53-41-14-283-001.SDR F3LA2018040400308Floor Support · corrodedAFT WET AREA FLOOR SUPPORT -Y1292 CORRODED, FRAMES 66 - 68. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, SRM 51-74-00, AND SRM 53-00-14-283-002.SDR F3LA2018040400309Floor Support · corrodedAFT WET AREA FLOOR SUPPORT CORRODED -Y512 AROUND F/A SEAT MOUNT. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, SRM 53-00-14-283-002, AND SRM 51-44-11.SDR F3LA2018040200301Floor Support · corrodedAFT WET AREA FLOOR SUPPORT CORRODED -Y512 AROUND F/A SEAT MOUNT. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, 53-00-14-283-002, AND 51-44-11.SDR F3LA2018031900297Floorbeam · corrodedAFT WET AREA FLOORBEAM -Y254 CORRODED AT FRAME 68-70. REMOVED FLOORBEAM AFT -Y254 FRAME 68-70 AND REPLACED IAW SRM 51-72-11-911-001.SDR ASAA2018022523695Interface Unit · failedNR 2 ENGINE EIU FAULT. ECAM ENG-2 APPROACH IDLE ONLY. A/THR INOPERATIVE, REV 2 INOPERATIVE. ACFT GROUNDED. R & R THE NR 2 ENGINE EIU (ENGINE INTERFACE UNIT) IAW AMM 73-25-34 OPS CHECK TEST PER AMM 73-25-34-710-043-A FAULT CLEARED, OK FOR SERVICE.SDR F3LA2018022600290Skin · corrodedEXTERNAL FUSELAGE SKIN CORRODED BELOW LAVATORY VENT. REPAIRED THE SKIN IAW 80426356 AND EA A2-53R-34063.SDR AALA201802279027Apu · odorDUE TO CABIN ODOR, ACCOMPLISH CABIN AIR QUALITY IAW J/C 26L00021001. BASED ON FINDINGS, ACCOMPLISH DECONTAMINATION J/C 26L00021004. CHANGED APU IAW JOB CARD 26L31049003, OPS CHECKED GOOD AND PERFORMED JOB CARD 26L00021004, NO FURTHER DISCREPANCIES NOTED.SDR F3LA2018040900320Frame · crackedRIGHT FWD DOOR HAS INDICATIONS OF CRACKS, AFT INBD FRAME. REMOVED AND REPLACED THE DOOR FRAME IAW SRM 51-42-11, 56-31-17, 51-72-11, 51-21-11, AND 51-75-12.SDR F3LA2018040500317Door Frame · crackedRIGHT AFT EMERGENCY EXIT DOOR HAS INDICATIONS OF CRACKS ON AFT INBD FRAME. REMOVED AND REPLACED THE DOOR FRAME IAW SRM 51-42-11, AND SRM 51-72-11.SDR F3LA2018040500315Frame · crackedLEFT AFT EMERGENCY EXIT DOOR HAS INDICATIONS OF CRACKS AT MULTIPLE LOCATIONS OF THE FWD INBD FRAME. REMOVED AND REPLACED THE LT EMERGENCY EXIT DOOR FRAME IAW SRM 51-42-11, 51-72-11, 51-21-11, AND 51-75-12. REMOVED AND INSTALLED RT AFT EMERGENCY EXIT DOOR WSDR F3LA2018040400316Door Frame · crackedLEFT AFT EMERGENCY EXIT DOOR HAS INDICATIONS OF CRACKS AT MULTIPLE RIVET LOCATIONS ON THE AFT INBD FRAME. REMOVED AND REPLACED THE LT AFT DOOR FRAME IAW SRM 51-72-11, AND 51-42-11.SDR F3LA2018040200306Frame · crackedLEFT AFT EMERGENCY EXIT DOOR HAS INDICATION OF CRACKS AT MULTIPLE RIVET LOCATIONS ON AFT INBD FRAME. REMOVED AND REPLACED THE FRAME IAW SRM 51-42-11, AND SRM 51-72-11.SDR F3LA2018040200299Door Frame · crackedLEFT AFT EMERGENCY EXIT DOOR HAS INDICATIONS OF A CRACK AT MULTIPLE RIVETS LOCATIONS AND FWD INBD FRAME. REMOVED AND REPLACED THE LT AFT EMERGENCY DOOR FWD INBD FRAME IAW SRM 51-42-11, AND SRM 51-72-11. REMOVED AND REPLACED THE LT AFT EMERGENCY EXIT DOOR WISDR AALA201802219048Not Reported · odorTHE AIRCRAFT WAS GROUNDED. DUE TO CABIN ODOR EVENT REF MIC 8709762.SDR AALA201802209026Slide Raft · defectiveAIRCRAFT WAS GROUNDED. DOOR 2R ARMING HANDLE DIFFICULT TO OPERATE. ADJUSTED R2 DOOR VERTICAL MEASUREMENT PER AMM 52-13-00 AND REPLACED R2 DOOR SLIDE/RAFT PER J/C 26L00025011.SDR WX0A20180221305Inlet · contaminatedMOLDY SOCK ODOR IN COCKPIT. CLEANED OIL RESIDUE FROM INLET AND APU COWLING. R & R BOTH RECIRCULATION FILTERS.
Back to Airbus A320-214