What was found
FWD CABIN FLOOR SUPPORT AT FRAME 14, Y503 HAS CORROSION ALONG ATTACHMENT HOLES. FOUND TO BE OUT OF LIMITS & REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-42-11, SRM 51-44-11, SRM 51-21-11 AND SRM 53-11-14 FROM FRAMES 14 TO 16.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CABIN FLOOR SUPPORT AT FRAME 14, Y503 HAS CORROSION ALONG ATTACHMENT HOLES. FOUND TO BE OUT OF LIMITS & REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-42-11, SRM 51-44-11, SRM 51-21-11 AND SRM 53-11-14 FROM FRAMES 14 TO 16.