SDR ASAA2020040632603Shear Web · corrodedLEFT HAND SIDE STRUCTURE AFT SHEAR WEB CORRODED AT FR 70 GROUNDED - YES. REMOVED AND REPLACED SHEAR WEB IAW A320 SRM 51-42-11 AND AIRBUS DWG D53474180. CAT A REPAIR. NO ALLOWABLE LIMITS GIVEN IN SRMSDR ASAA2020032732561Support Frame · corrodedFRAME 36 BELLY FAIRING SUPPORT FRAME HAS CORROSION AT A/C CENTER LINE (STREAMER ATTACHED) GROUNDED - YES. REMOVED AND REPLACED FRAME 36 BELLY FAIRING SUPPORT IAW A320 SRM 51-44-11. MATERIAL LOSS ON SUPPORT IS 100% DUE TO CORROSION DOT AND STREAMER REMOVED PSDR ASAA2020031332413Skin · gougedRIGHT WING I/B FLAP LOWER SKIN GOUGED GROUNDED - YES. REPAIRED GOUGE ON RH WING IB FLAP LOWER SKIN BONDED REPAIR COUBLER IAW ASA A320 SRM 57-52-00-300-014 FINISHED RESTORED IAW ASA A320 CRM 51-75-12SDR ASAA2020030632358Fault Message · abnormalAIR PACK #1 REGUL. FAULT GROUNDED - YES. PERFORMED BITE TEST OF THE TEMP CTL REF AMM 21-61-00 TEST OK NO FAULT NOTEDSDR ASAA2020030242512Beam · corrodedMAIN CABIN, LONGITUDINAL BEAM CORRODED BETWEEN FR18 AND FR20 APPROX. -Y1292. MARKED GROUNDED - YES. REPAIRED MAIN CABIN LONGITUDINAL BEAM FROM FRAME 18-20 -1292 IAW 51-42-11, 51-72-11 AND DWG UR-D531-10920. BLENDED BEYOND LIMITS PART REPLACED.SDR AALA202003039017Slide · defectiveAIRCRAFT IN BASE VISIT: R1 DOOR EMERGENCY ESCAPE SLIDE ARMING HANDLE IS HARD TO ARM. REMOVED AND REPLACED R1 DOOR ESCAPE SLIDE IAW ROUTINE JOB CARD 26L00025011.SDR ASAA2020032332488Support Beam · corrodedMAIN CABIN SUPPORT BEAM CORRODED @ FRAME 68 -Y638 GROUNDED - YES. REMOVED CORRODED BEAM IAW A320 SRM 51-42-11. INSTALLED NEW BEAM PN D536721950400 P.O. 968361.1 IAW A320 SRM 51-42-11 AND DWG # D534-72095 AND DWG #D534-72836 REMOVED CORROSION IAW A320 SRM 53-00SDR ASAA2020032332484Floorbeam · corrodedMAIN CABIN BETWEEN FRAME 69-70 Y254 HAS CORROSION ON SUPPORT BEAM GROUNDED - YES. REMOVED AND REPLACED FLOOR BEAM Y254 IAW A320 SRM 51-42-11. AIRBUS DWG D53472040700701. CORROSION REMOVED ON FLOOR BEAM IAW A320 SRM 53-00-14 .050 MATERIAL REMOVED .100 REMAININGSDR ASAA2020031632421Support Beam · corrodedMAIN CABIN BETWEEN FRAME 69-70 -Y254 HAS CORROSION ON SUPPORT BEAM GROUNDED - YES. REMOVED CORROSION, ORIG THICKNESS .150 REMOVED .050 REMAINING MAT .100 FOUND TO BE OUT OF LIMITS IAW A320 SRM 53-00-14-283-002. REMOVED SUPPORT BEAM FROM FRAME 69-70Y254 SDR AALA2020030329007Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN FLOOR PANEL 241KF HAS BUBBLES / DELAMINATED ON UPPER SURFACE. REPAIRED FLOOR PANEL PER SRM 53-02-00-300-002.SDR AALA2020030329006Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN FLOOR PANEL #241FF HAS BUBBLES / DELAMINATION ON UPPER SURFACE. REPAIRED FLOOR PANEL PER SRM 53-02-00-300-002.SDR F3LA202003020013Unknown · smoke03/02/2020 - PRELIMINARY SUBMISSION: LP1140723 ITEM 1 -- 5-10 MINUTES AFTER APU + PACK START UP CABIN FILLED WITH SMOKE/ FUME / SMELL . BURNING SMELL AND REDUCED VISIBILITY IN CABIN OBSERVED BY ALL 6 CREW MEMBERS . TURNED OFF APU BLEED +APU.SDR AALA2020030319018Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN FLOOR FITTING CRACKED AT FR 28 AND BL 0. REPLACED FLOOR FITTING PER SRM 51-40-02.SDR WX0A2020030273484Wire Harness · defectiveEMERGENCY EXIT SIGN WILL NOT LIGHT UP / INSTALLED WIRE HARNES 40WL TO LIGHT FIXTURE"SDR ASAA2020030232301Warning System · activatedTEMPERATURE CONTROL MAINTENANCE CLASS 2 MESSAGE ON STATUS PAGE GROUNDED - YES. DEFERREDSDR ASAA2020030232300Sensor · malfunctionedAPU AUTO SHUT DOWN, TWO ATTEMPTS. HAS HISTORY GROUNDED - YES. TURN APU MASTER SWITCH ON DO NOT START ACCESS APU SHUTDOWN DATA FROM THE APU PAGE ON MCDU AND UPDATE TROUBLESHOOTING TO ORDER PARTS.APU SHUTDOWN IS NOT BEING REPORTED TO PTMDR&R APU SPEED SENSOR, ASDR ASAA2020022753280Stringer · corrodedCORROSION AT, AFT PIT, R/H FRAME C51, STRINGER 38 GROUNDED - YES. REMOVED CORROSION AND CHECKED LIMITS. ORIGINAL THICKNESS IS .095, REMAINING IS .083, .012 WAS REMOVED. FOUND TO BE OUT OF LIMITS REF A320 SRM 51-73-11 AND AIRBUS DWG E53470525 ISSUE K. REPAIRED SDR AALA2020022659007Connector · faultyAIRCRAFT IN BASE MAINTENANCE: EMERGENCY LIGHT AT SEAT 24ABC WOULD NOT ILLUMINATE. RESET ELECTRICAL CONNECTOR AT SEAT 24ABC PER AMM 33-51-19-400-003-A AND PERFORMED SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-00-710-001-A.SDR AALA202002259014Floor Support · crackedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN FLOOR FITTING CRACKED AT FR 28 AND BL 0. REPLACED FLOOR FITTING PER SRM 51-42-11.SDR AALA202002259013Floor Support · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED CABIN FLOOR FITTING AT FR 28 AND LBL 24. REPLACED FLOOR FITTING PER SRM 51-42-11.SDR AALA202002259012Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN FLOOR PANEL #241KF IS DELAMINATED. REPLACED FLOOR PANEL PER AMM 53-00-00.SDR WX0A2020022473480Epsu · no testEPSU BATTERY FAILED EMERGENCY LIGHT TEST / REPLACED EPSU BATTERY"SDR ASAA2020030332341Spar · cracked#1 ENGINE AFT FIXED FAIRING UPPER INBD SPAR HAS VISUAL CRACK INDICATION IN RADIUS @RIB 11 GROUNDED - YES. ACCOMP. HFEC OF SUPPECTED CRACK IAW A320 NTM 51-10-08, CRACK NOTED APPROX .25" IN LENGTH, REMOVED AND REINSTALLED PNLS 475BR, 475BL, AND 477AL TO SDR WX0A2020022473481Computer · malfunctioned(EMERGENCY DECLARED) FLAP/CTL FLAPS FAULT ECAM MESSAGE FLAPS FAILED TO EXTEND /REPLACED SFCC #1. OPS CHECK GOOD."SDR WX0A2020022473478Light · inoperativeEMERGENCY EXIT LIGHT DAMAGED AND REMOVED / REPLACED R/H FWD EMERGENCY EXIT LIGHT"SDR WX0A2020022473479Epsu · inoperativeEMERGENCY LIGHTING ACTIVATION FAILED TEST/REPLACED BATTERIES"SDR ASAA2020022193231Apu · shutdownAPU AUTO SHUTDOWN TWO TIMES ON THE GROUND IN PVR WITH APU BLEED ON. GROUNDED - YES. INSPECTED APU OIL LEVEL FOUND TO BE FULL. PERFORMED APU OPS CHECK AS REQ PER AMM 49-00-00. TEST OK.SDR WX0A202002073477Epsu · no testMID L EPSU BATTERY FAILED EMERGENCY LIGHT TEST / REPLACED MID L EPSU BATTERY"SDR WX0A202002073476Epsu · no testFWD L EPSU BATTERY FAILED TEST / REPLACED FWD L EPSU BATTERY"SDR AALA2020022099015Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN FLOOR PANEL 241EF IS DELAMINATED. REPLACED FLOOR PANEL PER AMM 53-00-00-400-801-A.SDR AALA2020022099014Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN FLOOR FITTING AT FR 28 AND BL 0 CRACKED. REPLACED FLOOR FITTING PER SRM 51-42-11.SDR AALA2020022099010Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN FLOOR PANEL 241JF IS DELAMINATED. REPLACED FLOOR PANEL PER AMM 53-00-00-600-801-A.SDR AALA2020022099009Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN FLOOR PANEL 251SF IS DELAMINATED. REPLACED FLOOR PANEL PER AMM 53-00-00-600-801-A.SDR AALA2020022099007Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN FLOOR PANEL 252SF IS DELAMINATED. REPLACED FLOOR PANEL PER AMM 53-00-00-600-801-A.SDR AALA2020022099008Pump · faultyAIRCRAFT WAS GROUNDED: HYD GREEN RSVR LO LVL INFLIGHT EXTEND LANDING GEAR MANUALLY. REMOVED AND REPLACED NO.1 ENG GREEN HYDRO ENGINE DRIVEN PUMP IAW AMM 29-11-51. ALSO CHANGED CASE DRAIN, FILTERS ON GREEN SYSTEM AND CHANGED HCU PIPE ON NO.1 ENGINE.SDR F3LA2020021750009Unknown · odorPOSSIBLE FUME EVENT, BURNING RUBBER/ELECTRICAL SMELL REPORTED BY FA'S AROUND ROW 5, NEITHER PAC'S STOPPED SMELL, NOTHING OBSERVED ON HIGH. PERFORMED TSM FOR CAUSE OF CABIN ODER, INSPECTED AVIONICS BAY'S, NO EVIDENCE OF ABNORMAL SMELL, NO CB'S POPPED ON THE AC.SDR AALA2020021439005Power Supply · no testAIRCRAFT WAS NOT GROUNDED: FORWARD EMERGENCY POWER SUPPLY UNIT INOPERATIVE. MAINTENANCE REPLACED EMERGENCY POWER SUPPLY UNIT PER AMM 33-51-38.SDR AALA202002149013O-Ring · leakingAIRCRAFT WAS GROUNDED: AT FL200 FUMES IN THE COCKPIT AND REAR AREA OF THE AIRCRAFT. SMELL WAS WET SOCKS AND REMAINED FOR THE REMAINDER OF FLIGHT. REMOVED AND REPLACED O-RINGS COMMON TO THE APU FAN ASSY IAW AMM 49-52-51. REF J/C 26L00021001, 26L00021002, 26L000SDR F3LA2020031810019Window Post · crackedDISCREPANCY: REFERENCE PEMCO N/R # 2777N19 C/R REMOVE AND REPLACE L/H LATERAL WINDOW POST.
CORRECTIVE ACTION: REMOVED AND REPLACED L/H LATERAL WINDOW POST IAW A320 SRM 51-42-11, R53113942, R53112944, SRM 51-44-11, R53113355, SRM 51-48-00.SDR F3LA2020021200008Acm · seizedLP 1175072 ITEM 2 : STRONG ODER IN A/C. STRONGER IN REAR OF CABIN. ENG DEPT CREATING WORK SCOPE TO HELP WITH ID OF CAUSE AND T/S FOR PERMANENT FIX. R&R ACM PER A320 AMM 21-52-21-000-001-A, 21-52-21-400-001-A.SDR ASAA2020021492176Battery · no testEMERGENCY LIGHT EPSU 11WL FAILS CAPACITY CHECK GROUNDED - YES. REMOVED & REPLACED 11WL BATTERY S/N 792862. OPS CHECK GOOD. A320 AMM 33-51-00, 33-51-38.SDR SOKF2020021300002Engine · shutdownDURING FLIGHT FROM SAL TO YYZ THE AIRCRAFT DEVERTED TO MIA DUE TO APU AUTO S/D AND ENGINE #2 GENERATOR WAS INCLUDED IN DMI. AT MIA STATION AS PER TSM 49-00-81-810-819-A, PERFORMED REMOVED AND REPLACED OF LOW OIL PRESSURE SWITCH (8091KM) IN ACCORDANCE WITH AMM SDR F3LA2020021090007Power Supply · unknownL1 DOOR (EPSU (10WL) WILL NOT PASS SYSTEM TEST. PERFORMED OPS CHECK OF EPSU (10WL) PER TSM 33-51-00-810-282-A. OPS CHECK GOOD, NO DEFECTS NOTED.SDR WX0A202002073470Battery Pack · no testEMERGENCY LIGHT TEST FAILS AFT EPSU BATTERY / REMOVED AFT EPSU BATTERY"SDR WX0A202002073469Battery Pack · no testEMERGENCY LIGHT TEST FAILS MID-RIGHT EPSU BATTERY / REPLACE MID-RIGHT EPSU BATTERY"SDR WX0A202002073468Bulb · inoperativeRH EMERGENCY EXIT SIGN HAS BULBS INOP / REPLACED INOP BULBS"SDR WX0A202002073467Bulb · inoperativeLH EMERGENCY EXIT SIGN HAS BULBS INOP / REPLACED INOP BULBS"SDR F3LA2020020760006Oil Cooler · leakingTS DIRTY SOCK SMELL AS REQUIRED. DOWN TO APU REF TSM 05-50-00-869-051-A. INSPECTED APU FOR OIL LEAKS, FOUND AIR OIL COOLER AND FAN ASSEMBLY OIL COOLER LEAKING. APU WILL BE PLACED ON MEL ON LP1175030 ITEM 3.SDR WX0A202002073471Battery · inoperativeFLASHLIGHT BY L2 INOP / REPLACED FLASH LIGHT BATTERY"SDR ANCF20200206501Proximity Sensor · malfunctioned05.FEB.2020 -> AV9839 (BOG-AXM) PILOT REPORT (WO 15703901):
AFTER TAKE OFF DURING LANDING GEAR RETRACTION APPERS ON ECAM L/G DOORS NOT CLOSED. ECAM ACTIONS WERE PERFORMED UNSUCCESFULLY.
05.FEB.2020 -> CORRECTIVE ACTION WAS PERFORMED AS FOLLOWS:
IN ACCO