Airbus A320-214

Service difficulty reports · 10,616

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'A320214'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR AALA202002069004Cooling Fan · leakingAIRCRAFT WAS GROUNDED: CREW REPORTED STRONG COCKPIT/CABIN ODOR/SMELL, FLIGHT AIR RETURNED PHL, EMERGENCY DECLARED. ACCOMPLISHED J/C 26L00021001, FOUND APU TO SOURCE OF CABIN ODOR. ACCOMPLISHED J/C 26L00021002, FOUND OIL ON LOAD COMPRESSOR, INLET, AND COMING FRFeb 5, 2020 · N112US · Airbus A320214 · Air Distribution SystemSDR AALA202002069016Megaphone · inoperativeAIRCRAFT IN BASE VISIT: AIRCRAFT NOT GROUNDED: DURING REMOVE EMERGENCY EQUIPMENT FOUND LH FWD OVERHEAD BIN MEGAPHONE INOPERATIVE. REPLACED AND INSTALLED EMERGENCY EQUIPMENT LH FWD OVERHEAD BIN MEGAPHONE IAW A320 AMM 25-65-51-920-001-A.Feb 5, 2020 · N104UW · Airbus A320214 · Emergency EquipmentSDR ASAA2020021043107Warning Message · false activationAIR-PACK 1 REGUL FAULT GROUNDED - YES. PERFORMED COMPUTER RESET PER AMM 24-00-00-810-818-A STEP 3C. FAULT RESET. OK FOR SERVICE.Feb 4, 2020 · N283VA · Airbus A320214 · Cabin Cooling SystemSDR AALA2020020759009Power Supply · no testAIRCRAFT WAS NOT GROUNDED: EMERGENCY LIGHT POWER SUPPLY UNIT FAILED AT RIGHT EMERGENCY EXIT. MAINTENANCE REPLACED EMERGENCY POWER SUPPLY UNIT PER AMM 33-51-38.Feb 4, 2020 · N119US · Airbus A320214 · Emergency LightingSDR WX0A0202002057465Light · inoperativeL1 DOOR EMERGENCY LIGHT INOP / REPLACED EMERGENCY LIGHT ASSY"Feb 4, 2020 · N283NV · Airbus A320214 · Emergency LightingSDR ASAA2020040632605Floorbeam · corrodedRIGHT HAND FLOOR BEAM -Y1162 UPPER SURFACE CORRODED AT SPLICE AT FRAME 68 GROUNDED - YES. REMOVED AND REPLACED FLOOR BEAM IAW A320 SRM 51-42-11, AND AIRBUS DWG D53472458. CAT A REPAIRFeb 3, 2020 · N637VA · Airbus A320214 · Fuselage Main, Floor BeamSDR ASAA2020021033106Fire Loop · unknownDURING PRE-FLT INOP SYS ENG 2 LOOP B GROUNDED - YES. DEFERREDFeb 3, 2020 · N282VA · Airbus A320214 · Smoke DetectionSDR AALA202002059014Screen · cloggedAIRCRAFT WAS GROUNDED, APPROACHING CLE CREW RECEIVED A RIGHT ENGINE LOW OIL QUANTITY INDICATION FOLLOWED BY A LOW OIL PRESSURE ECAM WARNING. EMERGENCY DECLARED AND NUMBER 2 ENGINE SHUT DOWN ACCOMPLISHED. FLIGHT LANDED WITHOUT INCIDENT AND TAXIED TO GATE NORMALFeb 3, 2020 · N123UW · Airbus A320214 · Engine Oil Indicating SystemSDR WX0A0202002057464Megaphone · brokenMEGAPHONE BROKEN / R&R FWD MEGAPHONE"Feb 3, 2020 · N260NV · Airbus A320214 · Emergency EquipmentSDR AALA202002049019Pintle Pin · scoredAIRCRAFT IN BASE MAINTENANCE: RIGHT HAND MAIN LAND GEAR REAR PINTLE PIN HAS SCORING ON TH RIGHT WING ATTACHMENT AREA. REPLACED PINTLE PIN PER TASK CARD 26T00032001.Feb 3, 2020 · N128UW · Airbus A320214 · Wing, Landing Gear Attach FittingsSDR AALA202002039033Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: FORWARD CABIN FLOOR PANEL 231KF DELAMINATED. REPLACED FLOOR PANEL PER AMM 53-00-00-400-801-A.Feb 2, 2020 · N104UW · Airbus A320214 · Fuselage Floor PanelSDR ANCF2020020713101Fault Message · false activation31.JAN.2020 -> AV4901 (BAQ-BOG) PILOT REPORTED (WO 16047158): DURING TAKEOFF AND AFTER TAKE OFF NAV IAS DISCREPANCY FAULT ON ECAM DIFFERENCE BETWEEN CAP AND F/O AIRSPEED MORE THAT 60KTS. 31.JAN.2020 -> CORRECTIVE ACTION WAS PERORMED AS FOLLOWS: TEST OF Jan 31, 2020 · N481AV · Airbus A320214 · Navigation SystemSDR ASAA2020013132037Controller · failedCPC SYS 1 AND 2 FAULT UPPER ECAM. GROUNDED - YES. REMOVED AND REPLACED (12HL) CPC2 IAW AMM 21-31-34. PERFORMED AN OPS TEST ON THE 11HL AND 12HL CPC2 IAW AMM 21-31-00-710-002-A. TESTED OK.Jan 31, 2020 · N285VA · Airbus A320214 · Cabin Pressure ControllerSDR F3LA2020032580023Floorbeam · corrodedSUPPLEMENT 03/25/2020: SUPPLEMENT TO ORIGINAL SUBMISSION WITH A NEW UNIQUE CONTROL NUMBER. DISCREPANCY: REFERENCE PEMCO N/R # 2733N570 - Y765 CORRODED AT FRAME 66-70. CORRECTIVE ACTION: REMOVED AND REPLACED FLOOR BEAM - Y765 AT FRAME 66-70 IAW A320 SRM 51-42-1Jan 29, 2020 · N223FR · Airbus A320214 · Fuselage Main, Floor BeamSDR F3LA2020032580021Floorbeam · corrodedSUPPLEMENT 03/25/2020 - THIS IS A SUPPLEMENT TO THE ORIGINAL SUBMISSION WITH A REVISED UNIQUE CONTROL NUMBER - ORIGINAL NUMBER WAS F3LA202002110019- NEW NUMBER IS F3LA202001280021. DISCREPANCY: REFERENCE PEMCO N/R # 2733N567 - Y1292 CORRODED AT FRAME 66. CORREJan 28, 2020 · N223FR · Airbus A320214 · Fuselage Main, Floor BeamSDR F3LA2020032380020Floorbeam · corrodedDISCREPANCY: REFERENCE PEMCO N/R # 2733N567 - Y1292 CORRODED AT FRAME 66. CORRECTIVE ACTION: REMOVED AND REPLACED FLOOR BEAM - Y1292 AT FRAME 66 IAW A320 SRM 51-42-11 PAR. D AND 51-72-11.Jan 28, 2020 · N223FR · Airbus A320214 · Fuselage Main, Floor BeamSDR ASAA2020013172038Apu · shutdownAPU EMERGENCY SHUT DOWN. GROUNDED - YES. PERFORMED OPS CHECK IAW AMM 49-00-00 PB 501. NO FAULTS NOTED.Jan 27, 2020 · N286VA · Airbus A320214 · APU Core EngineSDR ASAA2020012731956Apu · unknownAPU EMER SHUT DOWN, GROUNDED - YES. PERFORMED OPS CHECK IAW AMM 49-00-00 PB 501. NO FAULTS NOTED.Jan 27, 2020 · N286VA · Airbus A320214 · Airborne Auxiliary Power Unit (APU) SystemSDR AALA202001249003Battery · no testAIRCRAFT WAS NOT GROUNDED: FLASHLIGHT, FLIGHT ATTENDANT SEAT, AT DOOR 1L DOES NOT TURN OFF. MAINTENANCE REPLACED FLASHLIGHT BATTERY PER STANDARD PRACTICES.Jan 23, 2020 · N125UW · Airbus A320214 · Emergency EquipmentSDR F3LA2020032580022Floorbeam · corrodedSUPPLEMENT 03/25/2020: SUPPLEMENT TO ORIGINAL SUBMISSION TO SHOW A NEW UNIQUE CONTROL NUMBER - ORIGINAL NUMBER WAS F3LA202001280019, NEW UNIQUE CONTROL NUMBER IS F3LA202001280022. DISCREPANCY: REFERENCE PEMCO N/R # 2733N395 - Y1162 CORRODED AT FRAME 68-69. CORJan 22, 2020 · N223FR · Airbus A320214 · Fuselage Main, Floor BeamSDR ASAA2020012721945Actuator · failedAT CRUISE, FL 360, THE AIRCRAFT HAD AN UNCOMMANDED YAW. NO ECAM. UNCOMMNDED RUDDER MOVEMENT IN FLIGHT AT 36000FEET - EMERGENCY LANDING DECLARED GROUNDED - YES. PER TSM 27-26-00-810-801-A. PRECAUTIONARY REPLACEMENT OF L/H YAW DAMPER SERVO ACTUATOR (FIN 3CC1) RJan 22, 2020 · N844VA · Airbus A320214 · Rudder Control SystemSDR AALA202001229016Fitting · wornAIRCRAFT WAS GROUNDED, L1 DOOR WAS REPORTED TO BE HARD TO OPEN & CLOSE. UPPER SUPPORT ARM FITTING WORN ALLOWING THE BEARING TO MIGRATE OUT OF THE FITTING. REPLACED UPPER SUPPORT ARM FITTING PER AMM 52-11-31-400-002-A.Jan 21, 2020 · N108UW · Airbus A320214 · Passenger/Crew DoorsSDR ASAA2020012403944Warning Message · false activationCABIN PRESSURE SYSTEM 1 FAULT MSG GROUNDED - YES. FAULT HISTORY LOGGED: PRESS CONTR 1, ATA 21-31-34. ACCOMPLISHED TSM TASK 21-31-00-810-803-A. ALL TEST PASSED. NO HISTORY, ALSO REF MDDR 70390. ETOPS RESTRICTEDJan 20, 2020 · N285VA · Airbus A320214 · Cabin Pressure Control SystemSDR ASAA2020012401887Blower · faultedVENT AVIONIC EXTRACT BLOWER FAULT. (20HQ). GROUNDED - YES. DEFERREDJan 20, 2020 · N284VA · Airbus A320214 · Air Distribution FanSDR ASAA2020012103889Fault Message · illuminatedCABIN PRESSURE SYS 1 FAULT MESSAGE. GROUNDED - YES. FAULT HISTORY LOGGED, PRESS CONTR 1. ACCOMPLISHED TSM TASK 21-31-00-810-803-A. ALL TEST PASSED. NO HISTORY, ALSO REF MDDR 70390 - ETOPS RESTRICTED.Jan 20, 2020 · N285VA · Airbus A320214 · Cabin Pressure ControllerSDR F3LA20200120002Oil System · leaking02/08/2020 - SUPPLEMENT ON LP 1175060 - REF TO MDDR# 1160287, FOUND APU LEAKING OIL, R&R APU IN REF TO TASK CARD MP49111-02, OPS/LEAK CHECK IS SATISFACTORY AT THIS TIME. T/W F9TAB4789C DUE 08/2020. T/W F9TAB4788C DUE 08/2020. T/WF9TAB4688C DUE 07/2020.HOIST, AJan 19, 2020 · N207FR · Airbus A320214 · APU Oil SystemSDR ASAA2020011732164Seat Track · corrodedMAIN CABIN FLOOR STRUCTURE AT C16, Y254, UPPER SURFACE OF TRACK FLANGE HAS CORROSION GROUNDED - YES. REMOVED CORROSION AND CHECKED LIMITS. ORIGINAL THICKNESS IS .063, REMAINING IS .019, .044 WAS REMOVED. FOUND TO BE OUT OF LIMITS REF A320 SRM 53-11-14-283-00Jan 17, 2020 · N641VA · Airbus A320214 · Fuselage, Seat/Cargo Attach FittingsSDR ASAA2020030232315Stringer · corrodedCORROSION AT, AFT PIT, R/H FRAME C51, STRINGER 38 LATE FIND GROUNDED - YES. REMOVED CORROSION AND CHECKED THE LIMITS. ORIGINAL THICKNESS IS .095, REMAINING IS .083, .012 WAS REMOVED. FOUND TO BE OUT OF LIMITS REF A320 SRM 51-73-11 AND AIRBUS DWG E53470525 ISJan 16, 2020 · N641VA · Airbus A320214 · Fuselage Main, Longeron/StringerSDR ASAA2020012463942Support · corrodedAFT MAIN CABIN, R/H SIDE, O/B FLOOR WEB SUPPORT ANGLE BETWEEN FR69-70 IS CORRODED GROUNDED - YES. REMOVED AND REPLACED WEB SUPPORT D5347112320300 REF AIRBUS DWG D53474180Jan 16, 2020 · N641VA · Airbus A320214 · Fuselage Miscellaneous StructureSDR AALA2020012179012Skin · crackedAIRCRAFT IN BASE MAINTENANCE: RIGHT HAND ELEVATOR LOWER SURFACE SKIN CRACKED 103.5 INCHES FROM THE INBOARD END AND 14.75 INCHES FROM THE TRAILING EDGE. REPAIRED ELEVATOR PER SRM 55-21-11-300-004.Jan 16, 2020 · N102UW · Airbus A320214 · Elevator, Plate/SkinSDR ASAA2020030232314Shear Plate · corrodedMAIN CABIN FLOOR STRUCTURE , SHEAR PLATE CORRODED BETWEEN FR69 AND FR70 AND STRINGER 22RH AND 24RH GROUNDED - YES. DISPLACED VACUUM BEN WIRES BETWEEN FRAME 69-70 RH AND REINSTALLED VAC. GENE WIRES IAW A320 AMM 38-31-64, OPS CHECK VACUUM GEN. WIRES IS GOOD IAW Jan 15, 2020 · N635VA · Airbus A320214 · Fuselage Miscellaneous StructureSDR ASAA2020030232313Shear Plate · corrodedMAIN CABIN FLOOR STRUCTURE, SHEAR PLATE CORRODED BETWEEN FR69 AND FR70 AND STRINGER 22LH AND 24LH. GROUNDED - YES. DISPLACED VOR COAX CABLE AND REINSTALLED VOR COAX CABLE IAW A320 AMM 34-55-11 AND ESPM 20-33-11 REMOVED AND REPLACED SHEAR PLATE IAW A320 SRM 51Jan 15, 2020 · N635VA · Airbus A320214 · Fuselage Miscellaneous StructureSDR ASAA2020022852298Floor Panel · corrodedMAIN CABIN FLOOR PANEL HAS CORROSION: 262LG R2 FLOOR PNL: P/N: E5367180502500 GROUNDED - YES. REMOVED CORROSION DAMAGE AND REPAIRED IAW EA# A320-53EA-00355 REV 00. ORIGINAL THICKNESS OF UPPER SKIN .063" LENGTH OF DAMAGE IS 38.5" AND WIDTH OF DAMAGE IS 3" WITH Jan 15, 2020 · N635VA · Airbus A320214 · Fuselage Floor PanelSDR ASAA2020022852292Stringer · corrodedAFT CARGO, STR.43 L/H HAS AREA OF CORROSION FROM FR. 56 TO FR.57 GROUNDED - YES. REMOVED CORROSION AND CHECKED THE LIMITS. ORIGINAL THICKNESS IS .110, .078 WAS REMOVED, REMAINING THICKNESS IS .032 FOUND TO BE OUT OF LIMITS REF A320 SRM 51-73-11. REPAIRED STR 4Jan 15, 2020 · N641VA · Airbus A320214 · Fuselage Main, Longeron/StringerSDR ASAA2020022153225Door Sill · corrodedMAIN CABIN, DOOR SILL CORRODED BETWEEN FR67 AND FR69 APPROX. -Y1250. MARKED GROUNDED - YES. REMOVED DOOR SILL TOP 3 PLATES, DOOR SILL, 4EA. DOOR SILL SPLICES AT FR.66, PLATE & SUPPORT AT FR.68-69, DRAIN LINES 2 EA AT FR.66 PER A320 SRM 51-42-11 ANJan 15, 2020 · N635VA · Airbus A320214 · Fuselage Miscellaneous StructureSDR ASAA202002132168Floor Panel · delaminatedMAIN CABIN FLOOR PANEL DELAMINATED: 231SF GROUNDED - YES. REPAIRED DELAMINATED MAIN CABIN FLOOR PANEL 231SF IAW A320 SRM 53-02-00-300-013, A320 SRM 51-77-11 & AIPC 53-22-02-01G AND EA A320-53EA-00319.Jan 15, 2020 · N635VA · Airbus A320214 · Fuselage Floor PanelSDR ASAA202002132167Floor Support · corrodedMAIN CABIN FLOOR STRUCTURE, LONGITUDINAL BEAM CORRODED AT FR68 APPROX. -Y780. MARKED GROUNDED - YES. LONGITUDINAL BEAM IS BEYOND MAX ALLOWABLE LIMITS OF .016 PER A320 SRM 53-41-14, REMOVED BEAM PER A320 SRM 51-42-11, LOCATED DRILLED AND DEBURRED NEW BEAM PARJan 15, 2020 · N635VA · Airbus A320214 · Fuselage Miscellaneous StructureSDR ASAA202002132166Support · corrodedMAIN CABIN FLOOR STRUCTURE, 304 FRAME SUPPORT CORRODED BETWEEN FR69 AND FR70 AND STRINGER 22RH AND 24RH. GROUNDED - YES. REMOVED SHEAR PLATE SUPPORT PER A320 SRM 51-42-11, INSTALLED NEW SHEARPLATE SUPPORT IAW A3200 SRM 51-42-11Jan 15, 2020 · N635VA · Airbus A320214 · Fuselage Miscellaneous StructureSDR ASAA202002132165Floor Support · corrodedMAIN CABIN FLOOR STRUCTURE, LONGITUDINAL BEAM CORRODED BETWEEN FR69 AND FR70 APPROX. +Y180. MARKED GROUNDED - YES. REMOVED FLOOR BEAM PER A320 SRM 51-42-11, LOCATED AND DRILLED NEW FLOOR BEAM PER A320 SRM 51-44-11, INSTALLED FLOOR BEAM BETWEEN FR. 69-70 IAW Jan 15, 2020 · N635VA · Airbus A320214 · Fuselage Miscellaneous StructureSDR ASAA2020021053110Floor Panel · delaminatedMAIN CABIN FLOOR PANEL DELAMINATED: 231MF GROUNDED - YES. REPAIRED DELAMINATED MAIN CABIN FLOOR PANEL 231MF OIAW A320 SRM 53-02-00-300-013, A320 SRM 51-77-11 & AIPC 53-22-02-01G, AND EA A320-53EA-00320Jan 15, 2020 · N635VA · Airbus A320214 · Fuselage Floor PanelSDR AALA202001249014Attach Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: RIGHT MAIN LANDING GEAR DOOR ACTUATOR AFT ATTACH FITTING VERTICAL LEG 2ND FASTENER HOLE FROM THE TOP CRACKED ON THE KEEL BEAM BETWEEN FR 42 AND FR 43 AT -Y440. REPAIRED ATTACH FITTING PER EA 302156.Jan 14, 2020 · N102UW · Airbus A320214 · Landing Gear DoorsSDR WX0A2020011573459Battery Pack · no testEMERGENCY LIGHT BATTERIES FAILED A CHECK. R & R ALL FOUR BATTERIES.Jan 14, 2020 · N220NV · Airbus A320214 · Emergency LightingSDR ASAA2020022132224Floor Panel · corrodedPARTS RACK- AFT WET AREA FLOOR PANEL 262LG IS CORRODED GROUNDED - YES. RECEIVED NEW FLOOR PANEL PO # 965072.3 FLOOR PANEL INSTALLED ON CARD G1326592 NO ALLOWABLE LIMITSJan 13, 2020 · N641VA · Airbus A320214 · Fuselage Floor PanelSDR ASAA2020022132223Floor Panel · corrodedPARTS RACK- AFT WET AREA FLOOR PANEL 261LG IS CORRODED GROUNDED - YES. RECEIVED NEW FLOOR PANEL PO # 965072.2. FLOOR PANEL INSTALLED ON TASK CARD G1326592 NO ALLOWABLE LIMITSJan 13, 2020 · N641VA · Airbus A320214 · Fuselage Floor PanelSDR ASAA2020022132222Web · corrodedAFT MAIN CABIN, R/H SIDE, O/B FLOOR WEB BETWEEN FR 69-70 IS CORRODED MARKED. GROUNDED - YES. REMOVED AND REPLACED AFT MAIM CABIN R/H SIDE O/B FLOOR WEB BETWEEN 69-70 IAW AIRBUS A320 SRM 51-42-11 AND DWG 18D53474180 NO ALLOWABLE LIMITSJan 13, 2020 · N641VA · Airbus A320214 · Fuselage Miscellaneous StructureSDR ASAA2020022132221Web · corrodedAFT MAIN CABIN, L/H SIDE O/B FLOOR WEB BETWEEN FR69-70 IS CORRODED. MARKED. GROUNDED - YES. REMOVED AND REPLACED FLOOR WEB REF AIRBUS DWG D53474180 AND A320 SRM 51-42-11. NO ALLOWABLE LIMITSJan 13, 2020 · N641VA · Airbus A320214 · Fuselage Miscellaneous StructureSDR ASAA202002132163Floor Support · corrodedAFT MAIN CABIN, R/H SIDE FLOOR BEAM FWD OF R2 DOOR CUTOUT, MOST O/B FLOOR BEAM HAS CORROSION MARKED. GROUNDED - YES. REMOVED CORROSION AND CHECKED LIMITS. ORIGINAL THICKNESS IS .150, REMAINING IS .106, .044 REMOVED. FOUND TO BE OUT OF LIMITS REF A320 SRM 5Jan 13, 2020 · N641VA · Airbus A320214 · Fuselage Miscellaneous StructureSDR ASAA2020021233105Seat Track · corrodedMAIN CABIN FLOOR WEB HAS NUMEROUS SPOTS OF SURFACE CORROSION BETWEEN STA C16 AND STA C20 LBL1651MM. GROUNDED - YES. REMOVED AND REPLACED MAIN CABIN SEAT TRACK REF A320 SRM 51-72-11 AND AIRBUS DWG D53112812 ISSUE "E" PO# 965684.1Jan 13, 2020 · N641VA · Airbus A320214 · Fuselage, Seat/Cargo Attach FittingsSDR ASAA2020021033104Seat Track · corrodedMAIN CABIN FLOOR BEAM HAS SURFACE CORROSION AT STA C20 RBL290MM. GROUNDED - YES. REMOVED AND REPLACED MAIN CABIN TRACK REF A320 SRM 51-72-11 AND AIRBUS DWG D53111460 ISSUE "C" PO# 964449.3Jan 13, 2020 · N641VA · Airbus A320214 · Fuselage, Seat/Cargo Attach FittingsSDR ASAA2020021032103Floorbeam · corrodedMAIN CABIN FLOOR BEAM HAS SURFACE CORROSION AT STA C20 RBL240MM. GROUNDED - YES. REMOVED AND REPLACED MAIN CABIN FLOOR SUPPORT RAIL REF A320 SRM 51-72-11 AND AIRBUS DWG D53111406 ISSUE "B" PO# 964396.1Jan 13, 2020 · N641VA · Airbus A320214 · Fuselage Main, Floor Beam
Back to Airbus A320-214