Airbus A320-232
Service difficulty reports · 32,653
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2019081091332Shear Plate · corrodedAFT CABIN LT SHEAR PLATE IS CORRODED. REMOVED AND REPLACED AFT CABIN L/H SHEAR PLATE AND APPLIED TOPCOAT TO ALL ATTACHING FASTENERS IAW SRM 51-72-11-911-01 AND SRM 51-42-11-801.SDR GTIA2019080834542Bottle · low pressureL2 DOOR ASSIST REQUIRES SERVICE-SERVICED L2 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2019080834541Megaphone · damagedFOUND FWD F/A STA. MEGAPHONE DAMAGED.-REMOVED AND REPLACED FWD F/A STA. MEGAPHONE IAW CMM 25-60-01 AND SPIRIT AIRLINES A320 EMERGENCY EQUIPMENT LAYOUT DRAWING: A320-232. OPS CHECK GOOD.SDR GTIA2019080834540A/C Pack · odorFUME EVENT. PACK OFF(APU BLEED ON) REQUIRED FOR T.O. AFTER DEPARTURE WHEN BLEED AIR WAS TRANSFERED FROM APU TO ENG A DIRTY SOCK SMELL WAS OBSERVED. PACK 1 WAS ISOLATED AND TURNED OFF. POSSIBLE ASSOCIATION WITH RAIN. FOUND THAT FUME EVENT WAS ISOLATED TO PACK SDR AALA201908089007Lens · brokenAIRCRAFT WAS NOT GROUNDED: EMERGENCY LIGHT LENS BROKEN AT 24ABC. MAINTENANCE REPLACED EMERGENCY LIGHT LENS PER AMM 33-51-19.SDR GTIA2019080874539Unknown · odorFA'S REPORTED ODOR (MUSTY, WET DOG) ON DESCENT -COMPLYIED WITH TSM 05-50-00-810-831-A FOR CABIN ODOR NO FURTHER ODORS NOTED.SDR YENA2019081260441Wire · pulledFT # 553, ROW 15ABC EMERGENCY PATH LIGHTING INOP, CANNON PLUG BACKSHELL WIRES PULLED OUT; R & R ROW 15ABC EMERGENCY PATH LIGHTING CABLE HARNESS IAW AMM 33-51-00. OPS GOOD. OK FOR SVC.SDR YENA201908126440Battery Pack · failedFT # 225, JFK-TPA. EMERGENCY LIGHT BATTERY 13WL FAILS TEST; R & R BATTERY 13WL IAW AMM 33-51-38. OPS CKS OK.SDR YENA201908126439Unknown · odorFLT 120, LEVEL II ODOR EVENT TRICRESYL PHOSPHATE (DIRTY SOCK) ODOR. BOTH PILOTS SCRATCHY THROAT SLIGHT HEADACHE. ISOLATED IN SEQUENCE BLEED 1 AND BLEED 2 ODOR DISAPATED WITH BLEED 2 OFF RESIDUAL ODOR RUNNING PACK 2 VIA CROSS BLEED AND LATER ON APU BLEED CABINSDR GTIA2019080854536Bottle · low pressureR1 DOOR ASSIT BOTTLE REQUIRES SERVICE-SERVICED R1 DOOR ASSIST BOTTLE IAW AMM 52-10-00. LEAK CHECK GOOD.SDR YENA2019080840436Wire Harness · inoperativeFT # 27, FLOOR EMERGENCY LIGHT SYS, SEAT 3C EMERGENCY LIGHT INOPERATIVE. R & R SEAT 3C WIRING HARNESS IAW AMM 33-57-11. OPS CHECKED NORMAL.SDR YENA2019080840437Unknown · odorFLT 96, RETURNED TO FIELD. INFLIGHT, SMELLED SMOKE IN AFT GALLEY AND ROWS 25, 26, AND 27. ACCOMPLISHED CHAPTER 5 INSPECTION IAW AMM 05-50-00-810-831-A FOUND NO EVIDENCE OF SMOKE ODOR OR BURNING PLASTIC. INSPECTED AIRCRAFT INTERIOR, AND AFT IFE RACK WITH NO SDR YENA2019080840435Battery Pack · inoperativeFT # 1525, WITH ALL POWER OFF THE AC MANY OF THE EMERGENCY LIGHTS ARE NOT ILLUMINATED ON BATTERY POWER I TRIED WITH THE OVERHEAD SWITCHES AND THE FAP. R & R LH EPSU BATTERY AND EMERGENCY EXIT RH EMERGENCY LIGHT BATTERY EXIT ROW IAW AMM 33-51-00.SDR YENA2019080804434Battery Pack · inoperativeFT # 1525, WITH ALL POWER OFF THE AC MANY OF THE EMERGENCY LIGHTS ARE NOT ILLUMINATED ON BATTERY POWER, TRIED WITH THE OVERHEAD SWITCHES AND THE FAP. R & R LH EPSU BATTERY AND EMERGENCY EXIT RT EMERGENCY LIGHT BATTERY EXIT ROW IAW AMM 33-51-00.SDR CALA2019080501314Bulkhead · crackedCRACK INDICATIONS NOTED OUTSIDE THE CUTOUT AREA AT FR35 LT SIDE, HOLES 3, 4 & 20. REPAIRED THE PRESSURE PANEL HOLES IAW ECRA 5331-02417 REV. A,SDR CALA2019080501313Stringer · corrodedAFT CARGO PIT STRINGER 43 LEFT BETWEEN FRAME 56-58 HAS CORROSION. FOUND STRINGER OUT OF LIMITS PER SRM 53-00-13-300-002. PERFORMED STRINGER REPAIR IAW SRM 53-00-13-300-001, SHT. 02, COUPLING TYP E 1.SDR CALA2019080501312Stringer · corrodedFWD CARGO COMPT FR 31-33 STRINGER 43R HAS CORROSION. FOUND STRINGER TO BE OUT OF LIMITS PER SRM 53-21-13-283-001. PER FORMED STRINGER REPAIR IAW SRM 53-00-13-300-001 SHEET 01, COUPLI NG TYPE 1.SDR CALA2019080501311Stringer · corrodedAFT CARGO PIT STR 42RT BETWEEN FR62-64 HAS CORROSION . FOUND STRINGER TO BE OUT OF LIMITS PER SRM 53-00-13-300-002. PER FORMED STRINGER REPAIR PER SRM 53-00-13-300-001 SHEET 02, COUPLI NG TYPE 1.SDR CALA2019080501310Stringer · corrodedAFT CARGO PIT STRINGER 42 LEFT BETWEEN FRAMES 54-56 HAS CORROSIO N PER HAECO LCQ NR LP 9294479 GENERATED BY V052030 UPON FURTHER EVAL STRG 42L BETWEEN FR 54-56 FOUND TO BE OUT OF L IMTS WITH ESS THAN .031IN REMAINING MATERIAL REMOVED AND REPALCE D STR 42L FR 5SDR CALA2019080501309Threshold · corrodedFWD CARGO THRESHOLD SPLICE PLATE HAS CORROSION. REMOVED AND REPLACED DISCREPANT FWD CARGO THRESHOLD PLATE IAW SRM 51-42-11-001 AND 51-72-11.SDR GTIA201908054532Unknown · odorF/A'S REPORT STRONG SULFER ODOR COMPLETED SUPPLEMENTAL 3.226.2 PACK 2 OFF.ODOR DISPIPATED-PERFORMED TSM 05-50-00-810-831A FOR IDENTIFICATION OF ODORS. RAN ENGINES,APU,PACKS WITH NO EVIDENCE OF ODORS AT THIS TIME. A/C OK FOR SERVICESDR YENA2019080730433Unknown · fumesFT 598, FUMES IN FOWARD CABIN. NR 1 AFTER T/O SAID HE BECAME DIZZY. DIVERTED BACK TO DEPARTURE. RAN FUMES CHECK LIST OVERWEIGHT CHECKLIST. APU BLEED AIR SUPPLY SYSTEM. COMPLIED WITH INFORMATION NOTICE 2017-T015E SECTION A. AIRCRAFT IS OK FOR SERVICE.SDR GTIA2019080334531Bottle · low pressureR2 DOOR ASSIST ACCUMULATOR LOW-SERVICED R2 DOOR ASSIST ACCUMULATOR TO PROPER PRESSURE IAW AMM 52-10-00SDR GTIA201908054530Bottle · low pressureL1 DOOR ASSIST BOTTLE NEED SERVICING-SERVICED L1 DOOR ASSIST BOTTLE TO PROPER LEVEL IAW AMM 52-10-00SDR YENA2019080920438Skin · corrodedPBI WAS FOUND WITH CORROSION DAMAGE ON SKIN PANEL AT FR70 BETWEEN STGR 30RH-32RH AT THE REAR FUSELAGE. ACCOMPLISHED A PERMANENT REPAIR PER THE REF /1/ EA AND COMPLIES WITH REF /2/ RDAS.SDR GTIA201908054526Unknown · odorDURING CRUISE ELECTRICAL ODOR, APPLIED COM PROCEDURE PACK 1 OFF ODOR DISSIPATED. REACTIVATED PACK 1 IAW AMM 21-51-00. PERFORMED RESIDUAL BURNING CLEANING IAW AMM 21-00-00 STEP 4 PARA C. NO ELECTRICAL ODOR NOTED AT THIS TIME.SDR GTIA201908054525Unknown · odorSTRONG PROPANE ODOR AFT GALLEY IN CRUISE. APPLIED TSM 05-50-00-810-085-B. TSM STEP4A--TYPE 2--NO EVIDENCE OF OIL, TYPE 3 NO EVIDENCE OF OIL, TYPE 4 NO EVIDENCE OF BIRD STRIKE, TYPE 5--NO EVIDENCE OF OIL, TYPE 6--NO EVIDENCE OF OIL.SDR CALA2019080431297Pressure Panel · crackedRH PRESSURE PANEL BETWEEN FR35-36 ROTO INSP REVEALS CRACK IN PRE SSURE PANEL LAYER AT HOLE A CRACK RADIATING IN THE 6 O''CLOCK POS . REPAIRED THE R/H SIDE PRES SURE PANEL AT FR35/36 IAW ECRA 5331-02426 PART 1. ACCOMPLISHED T HE PERMANENT REPAIR AT FR35/36 LH/RSDR CALA2019080401300Outflow Valve · malfunctionedVENT SKIN VALVE FAULT RESET CBS CFDS TEST PASSED OPS CK MM 21-26-00-710-001 ASDR YENA2019080510432Lens · missingFT # 272, EMERGENCY FLOOR LIGHTING ROW 1 C LENS MISSING, HOUSING DETACHED FROM BASE. INSTALLED NEW CLEAR EMERGENCY LIGHT LENS IAW 36-50-00. OPS CHECKED OK.SDR YENA2019080510431Battery Pack · no testFT # 225, EMERGENCY LIGHT TEST FAILED FOR FIN# 13WL BATTERY. REMOVED AND REPLACED AFT EPSU BATTERY AT 13WL IAW AMM 33-51-38.SDR YENA2019080510430Seal · leakingL-1 DOOR ASSIST ACTUATOR LEAKING; R & R L-1 ASSIST DIAPHRAGM SEALS IAW AMM 52-10-00. LEAK CKS OK.SDR GTIA201908053522Unknown · odorDURING DESCENT AFTER GOING THROUGH THE CLOUDS AN ODOR LIKE DIRTY SOCK OR A BREWERY OCCURRED THEN CLEARDED ONCE CLEAR OF THE CLOUDS-PERFORM CABIN ODOR INSPECTION IAW TSM 05-50-00-810-831-A NO SMELL PRESENT PER PILOT SMELL DISAPPREAED AFTER LEAVING CLOUDS NO DEFSDR GTIA2019080514521Unknown · odorFUME REPORTED IN CABIN DESCENDING BELOW FL180-ODOR REPORTED BY FLIGHT ATTENDANT FORWARD GALLEY ONLY. FLIGHT ATTENDANT STATED IT COULD HAVE BEEN A PASSENGER. RAN PACK 1 & 2 SEPERATELY. NO ODORS OR DISC, RAN RAN APU BLEED NO DISC, ENG RUN NO DISC, PER TSM 05-50-SDR CALA2019080101285Cleat · corrodedFWD CARGO FR 31-32 STGR 40R-41R CLEAT HAS CORROSION. REMOVED AND REPLACED CLEAT FR 31-32 STR 40R-41R IAW SRM 51- 72-11.SDR AALA2019080219002Hinge · wornAIRCRAFT WAS GROUNDED: NOSE LANDING GEAR LEFT HAND AFT DOOR FORWARD HINGE WORN. REPLACED HINGE PER AMM 32-22-13.SDR YENA2019080210428Lamp · inoperativeFT 2931, FLIGHT ATTENDANT REPORTED THE EMERGENCY EXIT ROW DOOR LIGHTS OUT. RELAMPED THE EMERGANCY EXIT DOOR LIGHT IAW AMM 33-51-07. OPS CHECKED OK.SDR YENA2019080231427Power Supply · no testFT # 1954, DURING WEEKLY CHECK FOUND FAULT ON EMERGENCY LIGHT SYS ESPU FWD LH. R & R ESPU UNIT AND BATTERY IAW AMM 33-51-38. FAULT CLEARED. TEST OK AT THIS TIME.A/C OK TO CONT SVC.SDR GTIA2019080134519Bottle · low pressureR2 DOOR ASSIST BOTTLE AT 250 PSI. SERVICED DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2019080134516Bottle · low pressureL1 DOOR ASSIST BOTTLE REQ SERVICE. SERVICED THE L1 DOOR PER AMM 52-10-00SDR GTIA2019080134515Door · underservicedRH REAR DOOR REQUIRES SERVING. SERVED DOOR ASSIT ON RH REAR DOOR IAW 52-10-00SDR YENA201908029426Lens · brokenFT # 1038FLOOR EMERG PATH LIGHT AT SEAT KNOCKED OUT OF SEAT & LENS BROKEN; R & R FLOOR EMERGENCY PATH LIGHT IAW AMM 33-51-19 OPS CHECK GOOD.SDR AALA201907299019Oven · odorAIRCRAFT NOT GROUNDED: PILOT REPORTS OVEN GALLEY RIGHT SIDE HAD ELECTRIC SMELL ON START UP. TURNED OFF, SMELL WENT AWAY. C/B IS PULLED. MAINTENANCE REMOVED AND REPLACED FWD GALLEY RT OVEN AND OPS CHECK GOOD IAW AMM 25-35-19.SDR GTIA2019072834507Ecs · contaminatedFUME EVENT DESCENDING THROUGH 16,000' - SMELL OF DIRTY SOCKS ( PACKS WITH MOD 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) - FAULT CAUTIONS ASSOCIATED WITH OPERATIVE SIDE NOT DISPLAYED )-PERFORMED A DECONTAMINATION OF THE ECS IAWSDR GTIA2019072834506Unknown · odorAT LEVEL OFF AT CRUISE PASSENGERS AND FAS SMELLED SWEET SMOKE SMELL IN THE FAR AFT OF AIRPLANE ONCE NOTIFIED, TURNED OFF PACK 2 AND SHUT X BLEED. NO FURTHER SMELL ( PACKS WITH MOD 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) - FASDR CALA2019072801264Roller · lack of lubeFLAPS LOCKED - ALIGNMENT FAULT DISPLAYED ON UPPER EC AM SCREEN. - F-CTL PLEASE WORK FAULTS IAW TSM 27-51-00-810-818-A. TOMC SMITH 847-700-9980 CONTACT TOMC 847-700-9980 UNLOCKED FOR AVIONICS UPDATE, TOMC SMITH SFCC BITE , NO CURRENT FAULT FOUND. ON LAST LEG RSDR YENA201907270425Shear Plate · crackedDURING HEAVY MAINTENANCE, REPORTED THAT DURING THE ACCOMPLISHMENT OF THE REF /3/ SB FOR INSPECTION OF THE TI- ANGLES BETWEEN THE BELLY FAIRING & KEEL BEAM SIDE PANEL (AS REQUIRED BY THE REF /4/ AD)– THAT ON THE RT SIDE THE TI-ANGLE AT FR 41-42 AND SHEAR PLATE SDR AALA201907289007Battery · dischargedAIRCRAFT WAS NOT GROUNDED: RIGHT REAR EMERGENCY FLASHLIGHT WAS INOPERABLE (NOT BLINKING ON INDICATOR). MAINTENANCE REPLACED FLASHLIGHT BATTERY PER STANDARD PRACTICES.SDR AALA201907279002Windshield · crackedAIRCRAFT WAS GROUNDED: R1 WINDSHIELD CRACKED / SHATTERED ON LANDING. REPLACED WINDSHIELD PER TASK CARD 26L21056001.SDR AALA201907299012Oil Cooler · leakingAIRCRAFT WAS GROUNDED: PILOT REPORTS AFTER T.O. WHEN RE-CONFIG FROM APU BLEED TO ENG BLEED, ODOR FILLED CABIN & COCKPIT, DISSIPATED SHORTLY THERE AFTER, ALL SIGN OF ODOR GONE AFTER 30MIN. MAINTENANCE FOUND APU OIL COOLER LEAKING. REMOVED AND REPLACED APU OIL C
Back to Airbus A320-232