As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FUME EVENT DESCENDING THROUGH 16,000' - SMELL OF DIRTY SOCKS ( PACKS WITH MOD 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) - FAULT CAUTIONS ASSOCIATED WITH OPERATIVE SIDE NOT DISPLAYED )-PERFORMED A DECONTAMINATION OF THE ECS IAW AMM 21-00-00-615-002-A. NO SMELL DETECTED AFTER RUNNING PACKS. THIS CLEARS DMI #2528164-1. DMI LOG UPDATED. PLACARD REMOVED. MOC NOTIFIED.