Airbus A320-232
Service difficulty reports · 32,653
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR YENA201710260870Light · shortedDURING AN EMERGENCY LIGHTS SYSTEM TEST, THE FWD LEFT EPSU INDICATED AN INTERIOR & EXTERIOR LOAD FAULT. PERFORMED TSM 33-51-00-810-808-A, THE FWD LEFT SLIDE LIGHTS HAD SHORTED. REPLACED SLIDE EMERGENCY LIGHTS. SYS TESTED GOOD.SDR GTIA2017102602214Bottle · low pressureAFT LEFT PAX DOOR ACCUMULATOR ASSIST BOTTLE REQUIRES SERVICE. SERVICED AFT LH PAX DOOR ASSIST BOTTLE IAW AMM 52-22-00.SDR AALA201710279003Battery · inoperativeFLASHLIGHT STRAP BROKEN AND RED LIGHT DOES NOT BLINK UNDER FA JUMPSEAT. REPLACED THE BATTERY.SDR YENA201710250871Smoke Detector · false activationSMOKE DETECTOR FOR LIVE TV WENT OFF. TURNED OFF RACK POWER. NO SMOKE VISIBLE OR ODOR. RESET THE SYSTEM IAW AMM 23-39-00. OPS CHECKED NORMAL.SDR YENA201710250869Seat Track · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON THE SEAT TRACK -Y1292, BETWEEN FRAMES 12 AND 24. REPLACED THE SEAT TRACT IAW SRM 51-72-11.SDR GTIA2017102402213Bottle · low pressureDURING A WEEKLY CHECK, FOUND THE R2 DOOR ASSIST BOTTLE WITH LOW PRESSURE. SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-10-0.SDR YENA201710240860Battery Pack · no testEPSU BATTERY 13WL FAILED AN EMERGENCY LIGHT TEST. R & R EPSU BATTERY IAW AMM 33-51-38. BATTERY AND SYSTEM OPS CHECKED GOOD.SDR GTIA2017102302211Epsu · faultyDURING TC 335100-03-1 FOUND EPSU 10WL AND 13WL WITH FAULTS. R&R EPSU 10WL AND 13WL IAW AMM 33-51-38. OPC GOOD.SDR CALA2017102303769Battery · dischargedFWD L EMER LIGHT BATTERY FAULT. REPLACED BATTERY TEST OK.SDR CALA2017102303768Battery · failedLEFT AND AFT EMERGENCY LIGHT BATTERYS FAIL CAPACITY CHECK. REMOVED AND REPLACED LEFT AND AFT EMERGENCY LIGHT BATTERYS REF AMM 33-51-38 PB401 OPS CHECK OK.SDR CALA2017102303767Battery · dischargedDOOR 1 LEFT EMERGENCY LIGHT CIDS MSG ON SIDS PANEL. R&R EMERGENCY BATTERY AND CONTROLLER.SDR CALA2017102303744Stringer · corrodedAFT CARGO COMPARTMENT FR57 STRINGER 39L HAS SURFACE CORROSION. REPAIRED AFT CARGO COMPARTMENT STRINGER 39L BETWEEN FR56 AND FR5 8 PER IAW SRM 53-00-13-300-001.SDR CALA2017102303743Stringer · corrodedAFT CARGO COMPARTMENT FR62 STRINGER 40R HAS SURFACE CORROSION. REPAIRED AFT CARGO COMPARTMENT STRINGER 40R BETWEEN FR61-FR63 PER SRM 53-00-13-300-001.SDR CALA2017102303742Skin · crackedINTERNAL FUSELAGE SKIN AT FRAME 35, STRINGER 30R, HAD A CRACK INDICATION. INTERIM REPAIR ACCOMPLISHED IAW ECRA 5330-0620 5 PART 1.SDR CALA2017102303741Support · corrodedRIGHT SHEAR WEB SUPPORT IS CORRODED. REMOVED AND REPLACED THE SUPPORT FRAMES 69 - 70 IAW SRM 51-72-11-911-001, AND SRM 51-44-11-001.SDR CALA2017102303740Support Angle · crackedLEFT WING L/E CAVITY SUPPORT ANGLE CRACKED, OTBD OF THE NR 7 SLAT TRACK. REMOVED AND REPLACED SUPPORT ANGLE IAW SRM 51-42-11, PARA. D, E,SDR CALA2017102303738Door Sill · corrodedR2 DOOR SILL CORRODED. REMOVED AND REPLACED THE DOOR SILL IAW SRM 51-42-11-001, PAR G, 2R AND 2F AND MT 53-025 PG. 4 ITRM 48,SDR YENA201710230856Battery Pack · no testEPSU BATTERY 12WL FAILED AN EMERGENCY LIGHT TEST. R & R THE BATTERY IAW AMM 33-51-38. SYSTEM OPS CHECKED GOOD.SDR YENA201710220867Skin · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON MAIN CABIN LT AFT SECTION BETWEEN FRAMES 67 & 68 ON THE FUSELAGE SKIN BETWEEN STRINGERS 25 & 26L. BLENDED THE AREA AND FOUND TO BE OUT OF LIMITS IAW SRM 53-41-11. CUT OUT DAMAGED AREA IAW SRM 53-41-11. FSDR YENA201710220866Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON THE MAIN CABIN LT AFT WET AREA FLOORBEAM AT FRAME 68 +Y765. REMOVED & REPLACED IAW IAW SRM 51-44-11.SDR YENA201710220865Shear Plate · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON THE MAIN CABIN SHEAR PLATE BETWEEN FRAMES 69 - 70. REMOVED AND REPLACED THE SHEAR PLATE IAW DWG D53471124 REV. C.SDR YENA201710220864Shear Plate · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON THE MAIN CABIN SHEAR PLATE BETWEEN FRAMES 69 & 70. FOUND TO BE OUT OF LIMITS IAW SRM 53-41-17. REMOVED THE SHEAR PLATE IAW SRM 51-42-11, RECEIVED, LOCATED, DRILLED, DEBURRED AND INSTALLED A NEW SHEAR PLSDR YENA201710220863Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR SUPPORT BETWEEN FRAMES 69 - 70. FOUND TO BE OUT OF LIMITS IAW SRM 53-41-17. REMOVED THE FLOOR SUPPORT IAW SRM 51-42-11. RECEIVED, LOCATED, DRILLED, DEBURRED AND INSTALLED A NEW SUPPORT IAW SRM 51-42-1SDR CALA2017102303737Spar · crackedLEFT ELEVATOR FWD SPAR HAS A CRACK. REPAIRED THE LT ELEVATOR SPAR IAW SRM 55-21-18-300 -002.SDR YENA201710220855Engine · overservicedON FINAL, AT 2000 FT, THE FA REPORTED A DIRTY SOCK ODOR IN THE FRONT AND AFT CABIN. ODOR DISSIPATED AFTER LANDING. THERE WAS NO ODOR IN THE FLIGHT DECK. ACCOMPLISHED INFO NOTICE 2017-T015B SECTION B, FOUND THE NR 2 ENGINE OVERSERVICED. SERVICED THE ENGINESDR YENA201710220854Landing Gear · malfunctionedLANDING GEAR LGCIU 2 FAULT ECAM DURING DESCENT. FOLLOWED QRH FOR BOTH LGCIU’S AT FAULT AND PERFORMED THE LG GRAVITY EXTENSION. UNDER THIS CONDITION THE AIRCRAFT HAD NO NOSE WHEEL STEERING AND WAS TOWED OFF THE TAXI WAY AFTER LANDING. THE CABIN WAS NOT PREPPEDSDR YENA201710210862Skin · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED THE SKIN FRAMES 69- 70, STRINGERS 31-32R, AROUND THE AFT LAVATORY VENT OUTLET. REPAIRED THE SKIN IAW SRM 53-41-11-300-400. MAJOR REPAIR.SDR YENA201710210853Epsu · no testDURING HEAVY MAINTENANCE, RIGHT EMERGENCY EXIT EPSU FAILED TO TEST. REPLACED EPSU IAW AMM 33-51-38-420-050-A. OPS CHECKED GOOD.SDR CALA2017102003722Power Supply · inoperativeWHEN PERFORMING EMERGENCY LIGHT CK FOR 2 SERVICE GOT MESSAGE EPSU FWD L. REPLACED ESPU AND BATTERY IN FWD POSITION REF 33-51-38 AMM. OPS CK GOOD.SDR CALA2017102003721Battery Pack · faultedON 1SV,ON EMERGENCY LIGHT CHECK. FOUND MSG FWD EMERGENCY BATTERY FAULTED. REPLACED EMERGENCY BATTERY PACK AT DOOR 1L. OPS CHECKED NORMAL.SDR CALA2017102003664Fitting · corrodedFWD CARGO DOOR FRAME AFT CORNER FITTING CORRODED IAW SRM 51-72-11-911-001. REMOVED & REPLACED THE CORNER FITTING IAW SRM 51-72-11-911-001.SDR CALA2017102003663Fitting · damagedAFT CARGO DOOR CUT OUT NR 2 LOCKING FITTING GOUGED. REMOVED THE GOUGE AND FOUND TO BE OUT OF LIMITS IAW SRM 53-46-11-283-001. INSTALL A NEW LOCKING FITTING IAW SRM 51-72-11-911-001, AND 51-42-11-001.SDR CALA2017102003688Altimeter · malfunctionedSTANBY ALTIMETER STICKS MOVING FROM 60 - 300 FT, DURING EACH REVOLUTION. APPEARS TO READ ACCURATELY. REMOVED AND REPLACED THE STANDBY ALTIMETER IAW 34-21-22-000-001-A, OPS CHECKED NORMAL AND AMM 33-13-00-710-001-A.SDR CALA2017102003656Stringer · corrodedSTRINGER 41L, FRAMES 53 - 60 FOUND CORRODED. R & R THE STRINGER IAW SRM 51-72-11-911-001.SDR YENA201710200852A/C Pack · odorDURING DECENT THROUGH 10,000 FT TO 6000 FT, A MUSTY DRY ODOR IN COCKPIT. SHUT THE NR 1 PACK OFF AND THE ODOR DISSIPATED. ACCOMPLISHED A PACK BURN OFF. ACFT OK FOR SERVICE.SDR GTIA2017101902206Door Seal · defectiveR1 DOOR MAKES SQUEALING/HISSING NOISE. REMOVED AND REPLACED DOOR SEAL IAW AMM 52-11-18. LEAKS CHECK GOOD, NO LEAKS NOTED AT THIS TIME.SDR CALA2017102003661Door Frame · crackedRIGHT AFT DOOR CUTOUT FRAME 68, STOP FITTING NR 1 LOWER INBOARD HOLE IS CRACKED IN FRAME LAYER AT 6:00 AND 12:00. REPAIRED THE DOOR FRAME IAW SRM 53-41-12-300-011.SDR CALA2017102003660Frame · corrodedR2 DOOR, FRAME 66, ONE INCH ABOVE THE DOOR SILL HAS CORROSION. REPAIRED IAW SRM 53-41-12-300-002, SRM 51-11-12-001, TABLE 00110, AND GMM 03-20-20, FIG 1.SDR YENA201710190850Battery Pack · failedRT EPSU BATTERY 12WL FAILED AN EMERGENCY LIGHT TEST. R & R THE BATTERY PACK IAW AMM 33-51-38, OPS CHECKED GOOD.SDR CALA2017102003675Plate · corrodedLAVATORY EXHAUST VENT REINFORCEMENT PLATE CORRODED ON INTERIOR SIDE. REMOVED THE PLATE IAW SRM 51-42-11-001, FABRICATED A NEW LAVATORY EXHAUST VENT REINFORCEMENT PLATE AND INSTALLED IAW SRM 51-42-11-001, PAR E.SDR CALA2017102003674Shear Tie · corrodedFWD CARGO BAY, FRAME 32, STRINGERS 40 - 41R SHEAR TIE HAS SURFACE CORROSION. REMOVED AND REPLACED THE SHEAR TIE IAW SRM 51-72-11-911-001.SDR CALA2017102003673Fitting · corrodedFWD CARGO DOORWAY, FWD CORNER FITTING HAS CORROSION, REMOVED & REPLACED THE FITTING IAW SRM 51-72-11-911-001.SDR CALA2017102003672Threshold · corrodedFWD CARGO DOOR THRESHOLD FRAMES 25 - 28, HAS SURFACE CORROSION. REMOVED & REPLACED THE THRESHOLD IAW SRM 5 1-72-11-911-001.SDR AALA201710199005Lens · brokenEMERGENCY LIGHT LENS BROKEN ABOVE THE 1L DOOR. REPLACED THE LENS.SDR YENA201710180851Fuel Sys · leakingEMERGENCY DECLARED, DIVERTED PASSING FL 240 AND APPROX 330 KTS, AIRCRAFT BEGAN A SIGNIFICANT VIBRATION. AIRCRAFT WAS SLOWED, AND VIBRATION CEASED AT APPROX 290 KTS. PASSING FL 240, RECEIVED FUEL AUTO FEED FAULT. FUEL PAGE SHOWED 12,000 LBS LEFT INNER TANK, 9,SDR YENA201710180845Wire · brokenEMERGENCY LIGHT ROW 1ABC INOPERATIVE. FOUND A BROKEN WIRE AT CONNECTOR VC5751A. REMOVED & REPLACED WIRE HARNESS. OPS NORMAL IAW AMM 33-51-00-710--001-A.SDR GTIA2017101702205Line · leakingWET SOCK ODOR AT 6,000 FT, ISOLATED THE NR 1 PACK AND THE SMELL CLEARED. FOUND APU SCAVANGE OIL LINE LEAKING, TORQUED THE LINE IAW AMM 20-21-11. OPS AND LEAK CHECKED GOOD.SDR GTIA2017101702204Unknown · odorDIRTY SOCK ODOR DURING DESCENT OUT OF 8000 FT. BURN OUT IAW AMM 21-00-00-615-002-A. OPS AND LEAK CHECKED GOOD, AND REMOVED AND REPLACED RECIRCULATION FILTERS IAW AMM 21-21-41.SDR GTIA2017101702203Fan · failedDURING DESCENT, THERE WAS A BURNING ODOR, FAN IN AMBER WAS ALERT IN COCKPIT ON COND PAGE. PERFORMED TSM 05-50-00-810-831, IDENTIFIED FAULT AS LEFT RECIRCULATION FAN.SDR YENA201710170849Floor Support · corrodedCORROSION WAS DISCOVERED ON THE AFT CARGO BAY FLOOR SUPPORT, FRAME 58. R & R THE FLOOR PANEL IAW SRM 51-42-11, 51-44-11.
Back to Airbus A320-232