SDR AALA201703229003Bushing · migratedMIGRATED BUSHING ON LEFT MAIN LANDING GEAR DOOR ACTUATOR, UPPER ATTACH POINT ON KEEL BEAM, FORWARD LUG AT FRAME 42 BETWEEN STRINGERS 41 AND 42L. REPLACED FITTING IAW EA 261038.SDR CALA2017022000413Sensor · dirtyRIGHT AFT DOOR SLIDE INDICATION.SLIDE DOES NOT SHOW BEING ARMED. CLEANED AND DOOR PROX SENSORS, OPS CHECKED GOOD BUT CANT DUPLICATE FAULT ON GROUND. TROUBLESHOT IAW AMM TASK 52-13-00-810-805-A AND OPS CHECKED IAW AMM TASK 52-73-00-710-001-A. COULD NOT DUPLICASDR AALA201702209010Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE. CRACK ON FORWARD CORNER UPPER SURFACE OF SHEAR PLATE AT STRINGER 23R BETWEEN FR 68 AND FR 69. REPLACED SHEAR PLATE PER SRM 51-42-11 AND SRM 51-72-11.SDR AALA201702209006Lens · missingEMERGENCY LIGHT LENS COVER AT ROW 11 RIGHT MISSING. REPLACED THE LENS.SDR AALA201703019017Support · corrodedCORROSION ON AFT GALLEY LOWER SUPPORT AT STRINGER 23L BETWEEN FRAMES 66 AND 68. REPLACED THE SUPPORT SRM 51-72-11, AND EA 267408.SDR AALA201702209021Contact · brokenLEFT WINDSCREEN EMERGENCY LIGHT WIRES 7441VS-B AND 7441VS-A CONTACTS ARE BROKEN. REPLACED CONTACTS.SDR AALA201702199010Lens · brokenRED EMERGENCY LENS BROKEN. REPLACED THE LENS.SDR AALA201703019015Floor Support · crackedCRACK ON AFT GALLEY FLOOR SUPPORT AT -Y254 BETWEEN FRAMES 64 TO 66. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DRAWING D53472040.SDR GTIA2017021701792Ecs · contaminatedFUME EVENT DESCENDING THROUGH 10000 FEET AFT GALLEY REPORT OF DIRTY SOCK SMELL. SUSPECTED CONTAMINATION FROM APU. PERFORMED DECONTAMINATION OF ECS IAW AMM 21-00-00-615-001. DURING STAGE 2 CLEANING NOTICED SLIGHT ODOR IN AFT CABIN. R&R BOTH OZONE FILTERS IAW AMSDR CALA2017021700389Battery · no testFWD EMERGENCY LIGHT BATTERY FAILED A CAPACITY CHECK. REPLACED BATTERY IAW MM 33-51-38-400-001.SDR CALA2017021700388Battery · no testRIGHT EMERGENCY EXIT LIGHTS BATTERY FAILED CAPACITY TEST. REPLACED THE BATTERY IAW MM 33-51-38-400-001SDR YENA201702160103Stringer · corrodedDURING HEAVY CHECK MAINTENANCE, CORROSION WAS DISCOVERED ON STRINGER 42L FR54 TO FR 55; REF NR 2017-47293 REPAIR IAW SRM A320 53-00-13.SDR YENA201702160102Floorbeam · corrodedDURING HEAVY CHECK MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM AT Y1292 FR 12 TO FR 24. R & R FLOORBEAM IAW SRM51-72-11.SDR YENA201702160101Seat Track · corrodedDURING HEAVY CHECK MAINTENANCE, CORROSION WAS DISCOVERED ON SEAT TRACK AT -Y1292 FR 64 TO FR 66. R & R FLOORBEAM IAW SRM 51-72-11.SDR YENA201702160100Floorbeam · corrodedDURING HEAVY CHECK MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM -Y1225 FR 66 TO FR 67. R & R FLOORBEAM IAW SRM 51-72-11.SDR YENA201702160099Floorbeam · corrodedDURING HEAVY CHECK MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM AT -Y1162 FR 67 TO FR 69. R & R FLOORBEAM IAW SRM 51-72-11.SDR YENA201702160098Floorbeam · corrodedDURING HEAVY CHECK MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM AT Y1162 FR 67 TO FR 69. R & R FLOORBEAM IAW SRM 51-72-11.SDR YENA201702160097Floorbeam · corrodedDURING HEAVY CHECK MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM Y1225 FR 66 TO FR 67. R & R FLOORBEAM IAW SRM 51-72-11.SDR YENA201702160096Floorbeam · corrodedDURING HEAVY CHECK MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM AT Y765 FR 64 TO FR 66. R & R FLOORBEAM IAW SRM 51-72-11.SDR YENA201702160095Floorbeam · corrodedDURING HEAVY CHECK MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR BEAM AT Y1292 FR 64 TO FR 66. R & R FLOOR BEAM IAW SRM 51-72-11.SDR YENA201702160094Dummy Rail · corrodedDURING HEAVY CHECK MAINTENANCE, CORROSION WAS DISCOVERED ON RAIL DUMMY AT -Y81 FR 12 TO FR 16. R & R RAIL DUMMY IAW SRM 51-72-11.SDR YENA201702160093Door Sill · corrodedDURING HEAVY CHECK MAINTENANCE, CORROSION WAS DISCOVERED ON LOWER SILL AT FR 66 TO FR68. R & R LOWER SILL IAW SRM 51-72-11.SDR YENA201702160092Floorbeam · corrodedDURING HEAVY CHECK MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM AT Y254 FR 12 TO FR 24. R & R FLOORBEAM IAW SRM 51-72-11.SDR YENA201702160091Door Sill · corrodedDURING HEAVY CHECK MAINTENANCE, CORROSION WAS DISCOVERED ON LOWER SILL AT FR 66 TO FR 68. R & R LOWER SILL IAW SRM 51-72-11.SDR YENA201702160090Dummy Rail · corrodedDURING HEAVY CHECK MAINTENANCE, CORROSION WAS DISCOVERED ON RAIL DUMMY AT Y503.2 FR 12 TO FR 16. R & R RAIL DUMMY IAW SRM 51-72-11.SDR YENA201702160089Floor Support · corrodedCORROSION WAS DISCOVERED ON FLOOR SUPPORT, Y765, FRAMES 12 - 24. R & R THE FLOOR SUPPORT IAW SRM 51-72-11.SDR YENA201702160088Floor Support · corrodedCORROSION WAS DISCOVERED ON FLOOR SUPPORT AT FRAMES 12 TO 16, -Y81. R & R THE FLOOR SUPPORT IAW SRM 51-72-11.SDR YENA201702160087Dummy Rail · corrodedCORROSION WAS DISCOVERED ON THE DUMMY RAIL AT Y940, FRAMES 14 - 16. R & R THE DUMMY RAIL IAW SRM 51-72-11.SDR YENA201702160086Floor Support · corrodedDURING HEAVY CHECK MAINTENANCE, CORROSION WAS DISCOVERED AT FLOOR SUPPORT -Y254 FWD GALLEY FRAMES 12 TO 24. R & R THE FLOOR SUPPORT IAW SRM 51-72-11.SDR AALA201703089004Attach Fitting · excess playAIRCRAFT IN BASE MAINTENANCE. EXCESSIVE PLAY ON VERTICAL STABILIZER, RUDDER HINGE ARM 5 BEARING. REPLACED HINGE ARM 5 SRM 51-72-11.SDR AALA201703079041Hinge Fitting · excess playAIRCRAFT IN BASE MAINTENANCE. EXCESSIVE PLAY ON BEARING, HINGE ARM FITTING ASSEMBLY 4 RUDDER AT RIB 6, VERTICAL STABILIZER. REPLACED HINGE ARM FITTING SRM 51-72-11.SDR AALA201702169011Floor Support · corrodedCORROSION ON FLOOR SUPPORT AT Y1292 BETWEEN FRAMES 68 AND 69. REPLACED FLOOR SUPPORT IAW SRM 53-00-14, 51-42-11, AND 51-23-12.SDR AALA201702169010Floorbeam · corrodedCORROSION ON AFT OUTBOARD MOUNT TOP SURFACE OF FLOORBEAM, LAVATORY D AT Y1292 BETWEEN FRAMES 64 AND 66. REPLACED FLOORBEAM IAW SRM 51-74-00, 51-42-11, AND 51-23-12.SDR AALA201702169019Bottle · low pressureL1 DOOR ASSIST PRESSURE LOW. SERVICED L1 DOOR ASSIST BOTTLE.SDR AALA201702169018Power Supply · faultedESPU 10WL FAULTED. REMOVED AND REPLACED ESPU.SDR AALA201702169017Lens · missingEMERGENCY LIGHT ON SEAT ROW 13ABC MISSING LENS. INSTALLED NEW LENS.SDR AALA201702169015Light · inoperativeEMERGENCY LIGHTS AT 1C INOPERATIVE. REPLACED LENS.SDR GTIA2017021401789Rib · crackedA CRACK FOUND AT 3 LOCATIONS ON THE RIB 2 LOWER FOOT BETWEEN STRINGERS 11-12 ON BOTH WINGS. REPAIRED IAW EO 5721-1705.SDR CALA2017021700393Frame · corrodedSUPPORT TASK C1 CORROSION ON RT FRAME 68 STRINGER 23R WAS FOUND CORRODED AND OUT OF LIMITS IAW SRM 53-41-12 FIG 106. FABBRICATED AND INSTALLED FITTING IAW 53-41-12 PARA 5A FIG 201.SDR CALA2017021700392Skin · damagedDENT AT FWD OF FRAME 8 BELOW STRINGER 24L, FOUND TO BE OUT OF LIMITS IAW SRM 53-11-11 PARA 4B. FABRICATED AND INSTALLED A REPAIR DOUBLER IAW SRM 53-00-11, FIG 240.SDR CALA2017021700391Door Sill · corrodedSUPPORT TASK C1, R2 DOOR SILL HAS CORROSION AT STRINGER 23R FWD OF FRAME 68. REMOVED AND REPLACED THE DOOR SILL IAW SRM 51-72-11.SDR CALA2017021700390Door Sill · corrodedSUPPORT TASK C1, L2 DOOR SILL HAS CORROSION JUST AFT OF FRAME 68, STRINGER 23L CORROSION DOES NOT GO UNDER FLOORBOARD. REMOVED AND REPLACED THE DOOR SILL IAW SRM 51-42-11 53-41-14SDR GTIA2017021401787Apu · malfunctionedFLIGHT ATTENDANTS REPORT STRONG FOUL SMELL IN AFT PART OF AIRCRAFT. FAULT CAUTIONS ASSOCIATED WITH OPERATIVE SIDE NOT DISPLAYED. REACTIVATED NR 2 PACK IAW AMM 21-51-00. OPS CK'S NORMAL REF ITEM 2171858-1. APU CHANGE AND PERFORMED DECONTAMINATION OF ESC IAW AMMSDR GTIA2017021401786Oxygen Mask · leakingFO O2 MASK HOSE LEAKS IF MOVED WHERE THE HOSE CONNECTS AT THE MASK. REPLACED FO O2 MASK IAW AMM 35-12-41. OPS CHECK GOOD.SDR YENA201702130107Unknown · odorA BURNING ODOR WAS REPORTED, ONE HOUR INTO THE FLIGHT FROM ROWS 18-20, THEN DISAPPATED. PERFORMED INSPECTION OF CABIN ROWS 18-20 IAW TSM 05-50-00-810-831-A. NO EVIDENCE WAS FOUND OF ANYTHING BURNING OR SMOKING. UPON CHECKING PFR, A LAVATORY SMOKE DETECTOR FASDR AALA201702149018Floorbeam · corrodedCORROSION ON G-5 GALLEY AFT MOUNT (TOP SURFACE ), CABIN FLOORBEAM AT Y765 AND FRAME 70. REPLACED THE FLOORBEAM IAW SRM 51-42-11, AND 51-72-11.SDR AALA201702149017Floorbeam · corrodedCORROSION ON AFT INBOARD TOP SURFACE MOUNT FOR LAVATORY D, CABIN FLOORBEAM AT Y765 AND FRAME 66. REPLACED FLOORBEAM IAW SRM 51-72-11 AND 51-42-11.SDR CALA2017021300365Unknown · malfunctionedEMERGENCY EXIT LIGHTS KEEP FLICKERING AT GATE IN ARM POSITION WITH EXTERNAL POWER CONNECTED WHEN I ARRIVED ON AIRCRAFT, EMERGENCY LIGHTS WERE NO LONGER FLICKERING. CYCLED EMERGENCY LIGHT SWITCH IN COCKPIT, OPS CHECKED GOODSDR CALA2017021300356Unknown · odorON DESCENT HEAVY ODOR FROM A/C VENT. SUSPECT ENGINE OIL PERFORMED ENGINE RUNS AND RAN PACKS, NO DEFECTS NOTED REF TSM 71-00-00-810-801-A13.SDR CALA2017021300366Power Supply · inoperativeEMERG PWR SUPPLY 10WL FAILED TEST. REPLACED POWER SUPPLY 10WL REF AMM 33-51-38.
Back to Airbus A320-232