Airbus A320-232
Service difficulty reports · 32,653
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR YENA201702120068Relay · failedPILOT REPORTED THAT ALL CABIN EMERGENCY LIGHTS REMAINED ON AND COULD NOT GET THEM TO EXTINGUISH. R & R RELAY 8WL IAW TSM 33-51-00. OPS CHECK PASSED.SDR AALA201702139004Lens · brokenLENS ON EMERGENCY EXIT LIGHT BROKEN. INSTALLED EMERGENCY EXIT LIGHT LENS.SDR GTIA2017021201783Apu · contaminatedFLIGHT ATTENDANTS REPORT A STRONG DIRTY SOCK ODOR IN CABIN DESCENDING AFTER 10,000FT IAW CABIN ODOR SHEET AND TSM 05-50-00-810-830. ODOR POINTED TO APU. INSPECTED APU FOUND EVIDENCE OF DE-ICE FLUID AT THE INTAKE AND BOTTOM OF APU DOORS CLEANED ARE AND PERFORMSDR GTIA2017021201782Unknown · odorODOR IN CABIN AND COCKPIT COMING FROM THE NR 1 PACK DURING FLIGHT ON APP EASB WITH OUT APU USED. PERFORMED TSM 05-50-00-810-831-A, INSPECTED NR 1 ENGINE, NR 2 ENGINE, AND APU FOR POSSIBLE LEAKS. NO LEAKS NOTED. PERFORMED NR 1 & 2 ENGINE RUNS IAW AMM 71-00-00SDR CALA2017021200337Skin · dentedDENT ON LT FUSE BETWEEN FR11 FR12 BELOW STR 23L FOUND OUT OF LIMITS. FABBED REPAIR DOUBLER IAW SRM53-11-11 FIG 207 AND INSTALLED REPAIR DOUBLER.SDR AALA201702139022Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION ON RIGHT AFT MOUNT FOR G-5 GALLEY FLOORBEAM AT -Y160 AND 6 INCHES FORWARD OF FR70. REPLACED FLOORBEAM PER SRM 51-72-11.SDR AALA201703019023Floor Panel · delaminatedDELAMINATION ON PASSENGER CABIN FLOOR PANEL 231SF. REPLACED FLOOR PANEL IAW SRM 53-02-00, AND IRM 9701 REVISION G.SDR AALA201703019019Floor Panel · delaminatedDELAMINATION ON PASSENGER CABIN FLOOR PANEL 231WF. REPLACED FLOOR PANEL IAW SRM 53-02-00, AND IRM 9701 REVISION G.SDR AALA201703019018Floor Panel · delaminatedDELAMINATION ON PASSENGER CABIN FLOOR PANEL 231VF. REPLACED THE FLOOR PANEL IAW SRM 53-02-00 AND IRM 9701 REVISION G.SDR YENA201702100108Girt Bar · failedR1 DOOR WOULD NOT ARM. REMOVED AND REFOLDED THE GIRT BAR IAW AMM 25-62-44. OPS CHECK PASSED.SDR GTIA2017021001780Door · openROW 28 OXYGEN DOOR OPENED. SECURED OVERHEAD SPACER AT ROW 28 IAW AMM 25-25-11 OPS CHECKED GOODSDR AALA201702119002Hinge Fitting · wornSIGNIFICANT AIRFRAME VIBRATION FELT THROUGHOUT ENTIRE AIRCRAFT. FLIGHT RETURNED TO DEPARTURE AND LANDED SAFELY WITHOUT FURTHER INCIDENT. NO EMERGENCY WAS DECLARED. AIRCRAFT WAS GROUNDED. MAINTENANCE FOUND EXCESSIVE PLAY ON THE LEFT ELEVATOR, NR 1 HINGE FITTISDR CALA2017021000321Fitting · dirtyLEFT AFT SLIDE INDICATION INOP ON DOOR-OXY SYSTEM ECAM PAGE - DOOR-OXY DOOR 2L ARMED ON GROUND SLIDE ARM DISAPPEARS IN FLIGHT. ONLY SHOWS ARM WHEN FA PUSHES HANDLE CLEANED FLOOR FITTINGS AND OPERATED ARM/DISARM LEVER MULTIPLE TIMES REF AMM 25-62-44. OP'S CHECKSDR CALA2017021000313Concentrator · faultyB ELEC PUMP LO PR DISPLAYED ON UPPER ECAM SCREEN. EMERGENCY DECLARED. RANG OUT PSI SWITCH CIRCUIT REF WD29-12-01PG1 2074GJ. CIRCUIT CHECKS OUT GOOD. REPLACED SDAC2 PER MM31-55-34-400-001-A PERFORMED OP TEST OF SDAC PER AMM TASK 31-50-00-710-003-A TEST OK. PERFSDR AALA201703159011Hinge Fitting · wornEXCESSIVE PLAY ON VERTICAL STABILIZER NR 1 HINGE ARM BEARING. REPLACED HINGE ARM FITTING IAW SRM 51-72-11.SDR AALA201703019014Fitting · corrodedCORROSION ON AFT GALLEY CENTER FITTING BETWEEN FRAMES 66 AND 68 AT STRINGER 23L. REPLACED FITTING IAW SRM 51-72-11 AND DRAWING D53480505.SDR GTIA2017020901776Unknown · odorABOUT 3000 FT DURING APPROACH DETECTED FUMES. TURNED OFF PACK 1 AND CLOSED CROSSBLEED. IT SEEMED TO ISOLATE THE MUSTY OIL ODOR. ONLY NOTICED IN COCKPIT.PERFORMED DECONTAMINATION OF THE ENVIRONMENT CONTROL SYSTEM IAW AMM 21-00-615-002 NO EVIDENCE OF ODOR AT THSDR GTIA2017020901775Unknown · odorDURING DECENT, RECEIVED A STRONG ODOR THROUGHOUT THE AIRCRACFT. STARTED OUT OF 14,000 FEET. PERFORMED ECS PACK BURN IAW TSM 05-50-00-810-831-A. NO ODOR NOTED.SDR AALA201702109006Lens · missingEMERGENCY EXIT LIGHT LENS COVER MISSING R2 DOOR. REPLACED LENS.SDR YENA201702080085Skin · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON THE FORWARD FUSELAGE SKIN AT FRAME 14 & STRINGER 36L. REPAIRED IAW EC A17-099-01.SDR YENA201702080084Shear Plate · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON THE AFT CABIN SHEAR PLATE AT FRAMES 69 - 70. R & R THE SHEAR PLATE IAW SRM 51-42-11 AND 51-73-11.SDR YENA201702080065Wire · brokenDURING ROUTINE MAINTENANCE, THE SEAT MOUNTED EMERGENCY LIGHT AT PAX SEAT 9 DEF HAS A BROKEN WIRE AT LIGHT ASSEMBLY; REPAIRED WIRE AT SEAT MOUNTED EMERGENCY LIGHT AT SEAT 9DEF IAW A320 ESPM 20-48-14. R & R EPSU 11WL IAW A320-33-51-38-000-001-A AND 33-51-38-400-SDR AALA201702109012Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION ON TOP SURFACE AFT MOUNT FOR G-5 GALLEY FLOORBEAM AT -Y765 BETWEEN FR 66 AND FR 70. REPLACED FLOORBEAM PER SRM 52-41-11.SDR AALA201702279030Skin · delaminatedDELAMINATION ON LEFT ELEVATOR UPPER SURFACE 55 INCHES FROM OUTER TIP AND 4 INCHES FROM TRAILING EDGE. REPAIRED IAW SRM 55-21-11.SDR YENA201702070067Filter · failedA/C PACKS PRODUCED A MUSTY ODOR. HAPPENS ON GROUND AND BELOW 5000 MSL. R & R THE NR 1PACK OZONE FILTER IAW AMM 21-51-41. OPS CHECKED GOOD.SDR AALA201702089009Proximity Switch · out of adjustAIRCRAFT WAS NOT GROUNDED. ECAM LEFT FORWARD EMERGENCY EXIT PRESSURE OK. MAINTENANCE ADJUSTED PROXIMITY SWITCH FOR FORWARD LEFT HAND EMERGENCY EXIT DOOR PER AMM 52-71-00.SDR AALA201703159019Floor Panel · delaminatedDELAMINATION ON PASSENGER CABIN FLOOR PANEL 242MF. REPLACED THE FLOOR PANEL IAW SRM 53-02-00 AND IRM 9701 REVISION G.SDR AALA201703159018Floor Panel · delaminatedDELAMINATION ON PASSENGER CABIN FLOOR PANEL 241MF. REPLACED THE FLOOR PANEL IAW SRM 53-02-00 AND IRM 9701 REVISION G.SDR AALA201703159016Floor Panel · delaminatedDELAMINATION ON PASSENGER CABIN FLOOR PANEL 251CF. REPLACED THE FLOOR PANEL IAW SRM 53-02-00 AND IRM 9701 REVISION G.SDR AALA201703019024Floor Panel · delaminatedDELAMINATION ON PASSENGER CABIN FLOOR PANEL 251AF. REPLACED FLOOR PANEL IAW SRM 53-02-00, AND IRM 9701 REVISION G.SDR AALA201703019021Floor Panel · delaminatedDELAMINATION ON PASSENGER CABIN FLOOR PANEL 242HF. REPLACED THE FLOOR PANEL IAW SRM 53-02-00, AND IRM 9701 REVISION G.SDR AALA201703019016Floor Panel · delaminatedDELAMINATION ON PASSENGER CABIN FLOOR PANEL 251FF. REPLACED THE FLOOR PANEL IAW SRM 53-02-00, AND IRM 9701 REVISION G.SDR GTIA2017020601771Unknown · odorDURING DESCENT UPON SELECTING ENGINE A / ICE FUME / DIRTY SOCK SMELL ENTERED COCKPIT. TURNED PACK 1 OFF + SMELL WAS ELIMINATED WITHIN 1 MINUTE. PERFORMED TSM 21-00-00-810-801-A. PERFORM TROUBLESHOOTING THROUGH PACK 1 DIDN'T FIND ANY ODOR AT THIS TIME. NO LEAKSSDR AALA201702089010Relay · faultedCENTER TANK NR 1 PUMP FAULTED. REPLACED 69QA RELAY.SDR CALA2017020600292Battery · dischargedEMERGENCY LIGHTS TEST FAILED AT PTP PANEL. REPLACED BATTERY AT EPSU 10WL REF AMM 33-51-38 PB401, NOW OK FOR SERVICE.SDR CALA2017020600291Power Supply · faultyPER 2SVC EMERGENCY LITE TEST FAIL ON CIDS PANEL. HAVE EPSU INT LOAD EMER L MSG. RPLD LT OW POWER SUPPLY, TEST PASS.SDR AALA201703159017Attach Fitting · damagedELONGATED HOLE IN RIGHT MLG DOOR FORWARD ATTACHMENT FITTING . REPLACED THE MLG DOOR FITTING EA 267630.SDR GTIA2017020501770Unknown · odorDURING APPROACH TO LAND F/A ADVISED COCKPIT OF A "DIRTY SOCK" SMELL. PERFORMED TSM 05-50-00-810-831-A NO SMELLS OR FUMES DETECTED. PERFORMED ENG RUNS ON BOTH 1 AND 2 ENG. IAW AMM 71-00-00-710-043A. NO SMELLS OR FUMES DETECTED. A/C OK FOR CONTINUED SERVICED.SDR CALA2017020600275Shear Plate · corrodedLEFT SHEAR PLATE CORRODED. REMOVED AND REPLACED SHEAR PLATE IAW SRM 51-74-00 AND SRM 51-42-11.SDR AALA201702059009Door · departedON ARRIVAL, EXTERIOR REFUEL PANEL DOOR 192MB WAS REPORTED MISSING. THE PANEL WAS FOUND DURING A RUNWAY SWEEP. REPLACED THE DOOR IAW AMM 52-42-18.SDR AALA201702229013Stringer · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION ON STRINGER 41L AT 3 INCHES FORWARD AND 4 INCHES AFT OF FR 26. REPAIRED STRINGER PER SRM 53-21-13.SDR YENA201702040106Gcu · failedGENERATOR NR 2 FAULT DID NOT RESET THEN AC BUSS NR 2 FAULT, NR 2 IDG DISCONNECTED. EMERGENCY DECLARED, FLIGHT DIVERTED, AND LANDED UNEVENTFULLY. R & R THE NR 2 GCU IAW AMM 34-22-00. OPS CHECK PASSED.SDR AALA201702059016Girt Bar · obstructedAIRCRAFT WAS NOT GROUNDED. DOOR 1R ECAM DOES NOT SHOW ARMED. MAINTENANCE CLEANED AREA OF DOOR 1R GIRT BAR AND ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR AALA201703019006Door Sill · corrodedCORROSION ON AFT CARGO DOOR SILL AT STRINGER 38R AND FRAME 55. REPLACED DOOR SILL IAW SRM 51-72-11.SDR AALA201702229015Door Sill · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION ON R-2 DOOR SILL PLATE (BOX) AT STRINGER 23R AND -Y1400, BETWEEN FR 66 AND FR 69. REPLACED R-2 DOOR SILL PLATE (BOX) PER SRM 53-42-11 AND DRAWING D53480019.SDR AALA201702229010Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION ON FLOORBEAM AT -Y1292 BETWEEN FR 64 AND FR 69. REPLACED FLOORBEAM PER SRM 51-72-11.SDR AALA201702209012Door Sill · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION ON R2 DOOR OPENING, AFT LOWER CORNER SHAPES, AROUND SILL PLATE AT STRINGER 23R AND FR 68. REPLACED R2 DOOR AFT CORNER SILL SHAPE PER SRM 51-72-11.SDR AALA201702169009Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION ON TOP SURFACE OF FLOORBEAM AT Y1292 BETWEEN FR 66 AND FR 68. REPLACED FLOORBEAM PER SRM 51-42-11.SDR AALA201702139035Coupling · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION ON AFT GALLEY INBOARD UPPER FLOORBEAM COUPLING AT -Y1162 AND FR 68. REPLACED COUPLING PER SRM 51-72-11.DRAWING D53472780.SDR YENA201702030083Door Sill · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON L2 DOOR SILL AT FRAME 66 +2. R & R THE DOOR SILL.
Back to Airbus A320-232