Airbus A320-232
Service difficulty reports · 32,653
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA201612169006Door Sill · corrodedCORROSION ON L2 DOOR SILL PLATE AT FORWARD GIRT FITTING MOUNT HOLES AT FRAME 66 AND +Y1292. REPAIRED IAW SRM 53-41-14-283.SDR AALA201612169003Door Sill · corrodedCORROSION ON L2 DOOR SILL PLATE JUST FORWARD OF FRAME 68 AND +Y1292. REPAIRED L2 DOOR SILL PLATE IAW SRM 53-41-14-283.SDR YENA201612101093Light · failedFLT 1512, WHEN PERFORMING EMERGENCY LIGHT TEST, FWD ESCAPE SLIDE LIGHT FAULTED. FOUND THE L1 DOOR ESCAPE SLIDE FAULTY. R & R L1 DOOR SLIDE IAW AMM 25-62-44. PERFORMED OPS TEST OF EMERG LIGHT SYSTEM. OPS TEST PASSED.SDR CALA2016121496030Door Sill · corrodedDOOR 2R SILL CORRODED AT FWD AND AFT ENDS DOOR SILL WAS REPLACED PER SRM 51-72-11 AND SRM 51-42-11.SDR CALA2016121496029Strap · corrodedAFT PRESSURE BULKHEAD FWD FACE RIGHT SIDE DOUBLER STRAP CORRODED AT FRAME 70, Y1162. DOUBLER STRAP WAS FABRICATED AND REPLACED IAW SRM51-42-11 AND 53-51-16.SDR CALA2016121496028Support · corrodedAFT CABIN FRAME 70 SUPPORT CORRODED AT STRINGER 23R. FRAME SUPPORT WAS REPLACED IAW SRM 51-42-11SDR CALA2016121496026Spar · corrodedLEFT WING OTBD FLAP LEADING EDGE HAS CORROSION ON FWD SPAR FWD FACE AROUND FASTENER HOLE JUST ABOVE FLAP TRACK NR 3 INSIDE PANEL NR 2. REMOVED CORROSION LT WING OTBD SPAR WEB AND FOUND TO BE OUT OF LIMITS, IAW SRM 51-74-00. REMOVED AND REPLACED THE SPAR WESDR YENA201612101091Battery Pack · failedDURING ROUTINE MAINTENANCE, EPSU FIN 11WL FAILED BATTERY TEST. R & R THE EPSU BATTERY IAW AMM 33-51-38. OPS CHECKED GOOD.SDR AALA201612299017Floorbeam · corrodedCORROSION ON LAVATORY A HARDPOINT AT FLOORBEAM Y765 AND FRAME 16. REPLACED THE FLOORBEAM IAW SRM 51-75-12.SDR AALA201612169005Floor Support · corrodedCORROSION ON FLOOR SUPPORT BETWEEN FRAME 12 AND 24 AT +Y1292. REPLACED THE FLOOR SUPPORT SRM 51-72-11 AND 51-42-11.SDR AALA201612169004Floorbeam · damagedFLOORBEAM JOINT AT FRAME 14 AND Y50 HAS DEEP BLEND, AND SURFACE DAMAGE. REPLACED THE FLOORBEAM JOINT IAW SRM 51-75-12SDR AALA201612149009Floor Support · corrodedCORROSION ON FLOOR SUPPORT AT -Y1292 BETWEEN FRAMES 20 AND 24. REPLACED THE FLOOR SUPPORT IAW SRM 51-42-11.SDR AALA201612149008Floor Support · corrodedCORROSION ON FLOOR SUPPORT AT -Y765 BETWEEN FRAMES 20 AND 24. REPLACED THE FLOOR SUPPORT IAW SRM 51-42-11, AND DRAWING D53112814.SDR YENA201612091090Fan · failedCREW REPORTED A BURNING ODOR IN THE COCKPIT.; ACCOMPLISHED ODOR INSPECTION IAW TSM 24-00-00-710-064-A. FOUND THE AVIONICS BLOWER FAN TO BE THE CAUSE OF THE ODOR. R & R THE FAN IAW 21-26-51. PERFORMED OPERATIONAL TEST IAW AMM 21-26-51-710-001. OPS CHECKS PASSSDR AALA201612109011Wire Harness · brokenAIRCRAFT WAS NOT GROUNDED. INOPERABLE SEAT MOUNTED EMERGENCY LIGHT ROW 13 LEFT. MAINTENANCE FOUND LIGHT ASSEMBLY DAMAGED AND WIRE BROKEN ON HARNESS. REPLACED LIGHT ASSY AND HARNESS OPERATIONAL CHECKED GOOD PER AMM 33-51-18 AND AMM SR33-007. (SEE AALA2016121090SDR AALA201612109010Light · damagedAIRCRAFT WAS NOT GROUNDED. INOPERABLE SEAT MOUNTED EMERGENCY LIGHT ROW 13 LEFT. MAINTENANCE FOUND LIGHT ASSEMBLY DAMAGED AND WIRE BROKEN ON HARNESS. REPLACED LIGHT ASSY AND HARNESS OPERATIONAL CHECKED GOOD PER AMM 33-51-18 AND AMM SR33-007. (SEE AALA2016121090SDR AALA201612109009Oven · contaminatedAIRCRAFT WAS NOT GROUNDED. BOTH FIRST CLASS OVENS SMOKE WHEN HEATED UP. MAINTENANCE FOUND MELTED/BURNED PLASTIC AND TAPE ON OVEN INSERT. REMOVED INSERT AND RAN OVENS THROUGH HEAT CYCLE. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR GTIA2016120901701Oxygen Mask · unwanted deployOXYGEN MASKS DEPLOYED, RIGHT LAST ROW. ACCOMPLISHED OPERATIONAL CHECK OF MANUAL MASK RELEASE IAW AMM 35-23-00-710-001A. OPS CHECKED OK.SDR CALA2016120901064Battery Pack · faultedEPSU UNIT EMEREMERGENCY LIGHT FAULT ON PTP. REPLACED EMERGENCY LIGHT BATTERY AT 21D. OPS CHECKED NORMAL.SDR CALA2016120901063Battery Pack · faultedEPSU BATTERY FWD LIGHT FAULT ON PTP. REPLACED THE EMERGENCY LIGHT BATTERY . OPS CHECKED NORMAL.SDR CALA2016120901062Battery Pack · no testDURING EMERGENCY LIGHT TEST BATTERY FAULT LEFT MESSAGE. REPLACED BATTERY PACK IN LEFT POWER SUPPLY. OPS CHECKED GOOD.SDR CALA2016120901061Power Supply · faultyEMERGENCY LIGHT TEST SHOWS EPSU EMERGENCY LIGHT FAULT. REPLACED EMERGENCY LEFT POWER SUPPLY AND BATTERY IAW MM 33-51-38 PG.0401. EMERGENCY LIGHT TEST OPS CHECKED NORMAL. REPLACED EMERGENCY LEFT EPSU AND BATTERY IAW MM 33-51-38, PG401.SDR CALA2016120996021Door Sill · corrodedR2 DOOR SILL HAS NUMEROUS AREAS OF CORROSION. REMOVED & REPLACED THE DOOR SILL IAW SRM 51-42-11, PG.25 & SRM 51-72-11, PG.1.SDR AALA201612089002Track · obstructedSHORTLY AFTER TAKEOFF, THE L1 DOOR SLIDE DID NOT INDICATE ARMED. AIRCRAFT WAS PRESSURIZING NORMALLY. MAINTENANCE CLEANED DEBRIS FROM L1 DOOR TRACK, CYCLED DOOR AND ARMING MECHANISM SEVERAL TIMES. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR CALA2016120996022Door Frame · corrodedLEFT FWD EMERGENCY HATCH HAS CORROSION ON INNER STRUCTURE FITTING AFT LOWER CORNER. REMOVED CORROSION AT LH FWD EMERGENCY HATCH T SECTION LOWER FRAME. NO ALLOWABLE DAMAGE LIMITS IN SRM. R & R T SECTION, CURVED EDGE FRAME, SEAL RETAINER IAW SRM 51-42-11,PAR.SDR YENA201612071084Battery · no testDURING MAINTENANCE, AN OPS CHECK WAS PERFORMED. FWD ESPU BATTERY FAILED DURING BATTERY TEST. EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE. R & R L2 DOOR ESPU BATTERY IAW AMM IAW 33-51-38. R & R L2 ESPU (10WL) IAW AMM 33-51-38. PERFORMED OPS CHECK. OPS CHECK SDR YENA201612071083Epsu · failedDURING MAINTENANCE, AN OPS CHECK WAS PERFORMED. FWD ESPU BATTERY FAILED DURING BATTERY TEST. EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE. R & R THE BATTERY PACK IAW AMM IAW 33-51-38. R & R L2 ESPU (10WL) IAW AMM 33-51-38. OPS CHECK PASSED.SDR GTIA2016120501693Oxygen Mask · unsecurePAX OXYGEN MASKED DROPPED AND DOOR NOT CLOSED ROW 28A. REMOVED AND REPLACED PAX O2 MASK GENERATOR CONTAINER ROW 28A IAW AMM 35-21-41. OPS CHECK GOOD.SDR AALA201612069014Computer · failedTHE NR 1 AND 2 CENTER FUEL TANK BOOST PUMP FAILURES. AIRCRAFT WAS GROUNDED. AIRCRAFT RETURNED TO DEPARTURE AND DECLARED AN EMERGENCY. MAINTENANCE REPLACED THE PUMPS GFI 69QA, AND 70QA ALONG WITH THE FUEL QUANTITY INDICATION COMPUTER IAW ESPM 20-46-50-101, ASDR AALA201612069013Pump · failedTHE NR 1 AND 2 CENTER FUEL TANK BOOST PUMP FAILED. AIRCRAFT WAS GROUNDED. AIRCRAFT RETURNED TO DEPARTURE AND DECLARED AN EMERGENCY. MAINTENANCE REPLACED THE PUMPS GFI 69QA, AND 70QA, ALONG WITH THE FUEL QUANTITY INDICATION COMPUTER IAW ESPM 20-46-50-101, ANSDR AALA201612069012Pump · failedNR 1 AND 2 CENTER FUEL TANK BOOST PUMP FAILED. AIRCRAFT WAS GROUNDED. AIRCRAFT RETURNED TO DEPARTURE AND DECLARED AN EMERGENCY. MAINTENANCE REPLACED THE PUMP GFI 69QA, AND 70QA ALONG WITH THE FUEL QUANTITY INDICATION COMPUTER IAW ESPM 20-46-50-101, AND 24-4SDR AALA201612069006Girt Bar · obstructedR2 DOOR SLIDE ARMING HANDLE STUCK. CLEANED DEBRIS FROM GIRT BAR AND ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR CALA2016120501034Battery Pack · dischargedTESTED EMERG LIGHTS ON FAP. GOT MSG "EPSU UNIT AFT L" PER TSM 33-51-00-810-801-A, NEED TO REPLACE BATTERY PACK AND BATTERY. PN 3214-54-10 AND 3214-31. REMOVED AND REPLACED AFT BATTERY PACK AND AFT BATTERY IAW AMM 33 -51-38. OPS NML.SDR CALA2016120501017Fan · faultyAVNCS VENT EXTRACT CB POPPED. SMOKE IN COCKPIT. ON GND IN RSW REPLACED AVNCS VENT EXTRACT FAN REF AMM 21-26-51-401.SDR CALA2016120501035Lens · defectiveEMERGENCY PATH LIGHT AT ROW 2B INOP. REPLACED LENS CAP AND CHECKED LIGHT OK.SDR YENA201612041081Control Unit · failedEMERGENCY DECLARED. PILOT REPORTED RECEIVING LGCIU 2 FAULT UPON GEAR EXTENSION. PERFORMED THE QRH PROCEDURE WITH A MANUAL GEAR EXTENSION. CREW DECLARED AN EMERGENCY. LANDED UNEVENTFULLY. R & R THE NR 2 LGCIU IAW AMM 32-31-71. PERFORMED GEAR SWING AS PRECAUTISDR GTIA2016120401690Oxygen Mask · unsecurePAX OXYGEN MASK DROPPED DOWN AND DOOR WILL NOT CLOSE. REMOVED AND REPLACED PAX O2 MASK GENERATOR CONTAINER ROW 28A IAW AMM 35-21-41. OPS CHECK GOOD.SDR YENA201612031080Seat Track · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED AT L2 DOOR FWD LOWER CORNER, SMALL AFT PIECE OF INBD SEAT TRACK Y1732, FRAME 66. R & R THE SEAT TRACK IAW SRM 51-72-11.SDR YENA201612031079Floor Support · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED FLOOR SUPPORT AT FRAME 68, -Y1292. R & R THE FLOOR SUPPORT IAW SRM 51-72-11.SDR GTIA2016120301685Oxygen Mask · unsecureFA FOUND OXYGEN MASK AT ROW 25 D,E,F SIDE HANGING OUT. FOUND O2 MASK AT ROW 25 TO BE LOOSE TRIM OF OVERHEAD BIN. RESECURED TRIM AS REQ IAW AMM 25-24-41. AC OK FOR SVC.SDR YENA201612031078Floor Support · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED AROUND SCREW HOLE ON THE FLOOR SUPPORT AT -Y1292, FR 66+8. R & R THE FLOOR SUPPORT IAW SRM 51-72-11.SDR YENA201612031077Floor Support · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON TWO SCREW HOLES ON FLOOR SUPPORT AT -Y1292, FRAME 66. R & R THE FLOOR SUPPORT IAW SRM 51-72-11.SDR YENA201612031076Door Sill · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON FRAME 67 + 19 R2 DOOR SILL. R & R DOOR SILL IAW SRM 53-41-14-300-001.SDR YENA201612031075Floor Support · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED AROUND SCREW HOLE ON THE FLOOR SUPPORT AT Y1292 FROM FRAME 64 TO 66. R & R FLOOR SUPPORT IAW SRM 51-72-11.SDR YENA201612031074Floor Support · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED AT SCREW HOLES FR 68+11ON FLOOR SUPPORT AT Y1292. R & R FLOOR SUPPORT IAW SRM 51-72-11.SDR YENA201612031073Floor Support · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVEREDS ON FLOOR SUPPORT AT Y1292 FRAMES 67 - 68. R & R THE FLOOR SUPPORT IAW SRM 51-72-11.SDR YENA201612031072Floor Support · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR SUPPORT AT Y1732 FR 65+10. R & R THE FLOOR SUPPORT IAW SRM 51-72-11.SDR YENA201612031071Floor Support · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR SUPPORT -Y1292 +8 INCHES FROM FR 16. R & R FLOOR SUPPORT IAW SRM 51-72-11.SDR YENA201612031070Floor Support · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON AT BARREL NUT HOLES ON FR 66 FLOOR SUPPORT Y464. R & R FLOOR BEAM Y464 IAW A302 SRM 51-72-11.SDR YENA201612031051Floorbeam · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS FOUND ON FLOORBEAM AT -Y1292 FR 66. R & R FLOORBEAM AT -Y1292 FR 66.
Back to Airbus A320-232