What was found
FLOORBEAM JOINT AT FRAME 14 AND Y50 HAS DEEP BLEND, AND SURFACE DAMAGE. REPLACED THE FLOORBEAM JOINT IAW SRM 51-75-12
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM JOINT AT FRAME 14 AND Y50 HAS DEEP BLEND, AND SURFACE DAMAGE. REPLACED THE FLOORBEAM JOINT IAW SRM 51-75-12