Airbus A320-232
Service difficulty reports · 32,653
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA201611159002Water Heater · failedDURING DESCENT, FLIGHT ATTENDANT CALLED TO SAY THAT A PASSENGER SMELLED ACRID ODOR IN THE FORWARD LAVATORY. ON LANDING THERE WAS A BURNED ELECTRICAL ODOR STILL LINGERING IN THE FORWARD LAVATORY. MAINTENANCE REPLACED THE FORWARD LAVATORY WATER HEATER IAW AMM SDR YENA20161114991Valve · failedFLIGHT CREW REPORTED VENT SKIN VALVE FAULT. R & R SKIN AIR INLET VALVE IAW AMM 21-26-52. OPS CHECK PASSED. ACFT OK FOR SERVICE.SDR CALA2016111400920Battery · dischargedEMER LIGHT TEST FAILS, EMER BATTERY L AND EMER BATTERY R. REPLACED BATTERIES IAW AMM 33-51-38. OPS TEST GOOD.SDR YENA20161113990Display · malfunctionedFLIGHT CREW REPORTED THAT AFTER DEPARTURE, THE NAVIGATIONAL DISPLAYS WERE NOT AVAILABLE ON THE MULTIFUNCTIONAL PANEL. ALL THREE IRS POSITIONS WERE NOT IN AGREEMENT WITH THE GPS. CREW ELECTED TO DIVERT. CHECKED THE ADIRUS RADIAL POSITION ERROR IAW 34-12-34. FOSDR CALA2016111695980Fitting · gougedRT WING MLG RETRACT JACK FTG LWR FLANGE 5TH HOLE FROM IB HAS GOUGE. INTERIM REPAIR ACP IAW EC RA 5720-02838 PART1.SDR CALA2016111695979Fitting · gougedRT MLG RETRACTION JACK ANCHORAGE FITTING CORRODED. INTERIM RPR ACP IAW ECRA 5720-02838 PART1.SDR CALA2016111695978Cleat · bentFR73 CLEAT BETWEEN STRINGER 32L-34L IS BENT. REPLACED CLEAT AT FR73 BETWEEN STRINGER 32L-34L IAW SRM 51-42-11.SDR CALA2016111695976Stringer · corrodedFWD CARGO STR42R CORRODED 8" FWD OF FR34. STR 42R BETWEEN FR33-34 REPAIRED IAW SRM53-21-13 PARA 5D FG204.SDR GTIA2016111201660Air Data Module · failedAFTER T/O ADR 1&3 FAIL RESULTING IN MULTIPLE ALLTONFD FAILURES. R&R AIR DATA MODULE NR 1 (19FP1) IAW AMM 34-11-17. OPS CHECKS GOOD IAW AMM 34-11-17. ALSO R&R AOA SENSOR NR 1 (3FP1) IAW AMM 34-11-19. OPS CHECK GOOD IAW AMM 34-10-00. NO FURTHER FAULTS NOTED.SDR YENA201611111003Door Frame · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON R1 PAX DOOR LOWER CUT OUT CORNER INTERNAL STRUCTURE FRAME 16+2 STR 23R. CORROSION WAS REMOVED. SPOT FACED AT R1 FWD GIRT BAR LATCH HOLES. INSTALLED BUSHINGS AND REPAIR WASHERS IAW SRM 53-11-14.SDR YENA201611111008Fitting · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON L2 CREW DOOR AFT GIRT BAR FITTING ; R & R DOOR LWR SILL IAW A320 SRM 51-72-11, 53-41-14-283-002, 53-41-14 .SDR YENA201611111007Fitting · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON L2 DOOR CORNER FITTING AT FRAME 68. R & R CORNER FITTING AND INSTALLED IAW SRM 51-72-11.SDR YENA201611111006Floorbeam · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN WET AREA FLOORBEAM Y1292 FRAME 69; R & R THE FLOORBEAM IAW SRM 51-72-11- PG 3-4 AND 51-42-11-PG 1-10.SDR YENA201611111005Floorbeam · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN WET AREA FLOORBEAM Y1292 FRAME 66. REMOVED AND REPLACED IAW SRM 51-72-11.SDR YENA201611111004Door Frame · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON R1 DOOR LOWER CUT OUT CORNER INTERNAL STRUCTURE FRAME 19+6 STR 23RH 4 EA AROUND THE FASTERNERS HOLES (FWD GIRT BAR AFT I/B HOLE, AFT O/B HOLE, FWD I/B HOLE, FWD O/B HOLE ) ; REMOVED CORROSION BY SPOT FACSDR YENA201611111002Floor Support · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN WET AREA FLOOR SUPPORT Y-254 FRAME 70; R & R THE FLOOR SUPPORT IAW SRM 53-00-14-283-002 AND SRM 51-75-12.SDR YENA201611111001Floorbeam · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN WET AREA FLOOR BEAM Y-1292 STR23 R/H FRAME 66+6 ; REMOVED FLOORBEAM, LOCATED DRILLED, BEBURRED TREATED, PRIMED, INSTALLED IAW A320 SRM 53-00-14.SDR YENA201611111000Door Sill · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON R2 PAX DOOR SILL FRAME 66 STR 23RH ; R & R R2 DOOR SILL FWD CWNTER & AFT SEALS & R/H TRIPLE BEAM LOCATED , DRILLED, DEBURRED, TREATED, PRIMED , INSTALLED & PART MARKED NEW DOOR SILL. INSTALLED R/H TRIPLE SDR YENA20161111999Floor Support · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON CENTER FLOOR SUPPORT FRAMES 18 TO 19. R & R THE FLOOR SUPPORT IAW GMM 5169, SRM 53-11-14-283-001, 51-42-11, AND 51-72-11.SDR YENA20161111998Floorbeam · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON AFT WET AREA FLOORBEAM Y-1292, FRAME 68. R & R THE FLOORBEAM IAW SRM 53-00-14-282-002, 51-42-11, AND 51-21-11.SDR YENA20161111997Floorbeam · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON AFT WET AREA FLOORBEAM Y-1292 RH FRAME 66. R & R THE FLOORBEAM IAW SRM 53-00-14-283-002, 51-42-11, 51-44-11, 51-21-11, & 51-72-11.SDR YENA20161111996Dummy Rail · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN WET AREA DUMMY RAIL Y464 STRINGER 23L FRAME 66 - 66 + 4. R & R THE DUMMY RAIL IAW SRM 53-00-14-283-002, AND 51-72-11.SDR YENA20161111995Floor Support · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED AT -Y1292 RT SIDE FLOOR SUPPORT FRAMES 14 TO 16; R & R THE FLOOR SUPPORT IAW SRM 51-42-11 PARA F & 51-72-11.SDR YENA20161111994Floorbeam · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN WET AREA FLOORBEAM Y765 STR 23L FRAME 68 ; R & R THE FLOORBEAM IAW SRM 53-41-14 & 51-72-11.SDR YENA20161111993Shear Plate · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON AFT WET AREA SHEAR PLATE STRINGER 23R, FRAMES 69-70. ; R & R AFT CABIN SHEAR PLATE IAW SRM 51-72-11, 53-41-14 FIG 002.SDR AALA201611129005Lens · missingMISSING LENS COVER ON FLOOR EMERGENCY LIGHT AT SEAT 13C. REPLACED LENS COVER.SDR YENA20161111977Epsu · failedFWD EXIT LIGHTS OVER BOTH PASSENGER DOORS WERE INOPERATIVE. R & R EPSU (10WL) IAW AMM 33-51-38. PERFORMED OPS CHECKS. OPS CHECKD PASSED.SDR CALA2016111100880Door · not seatedL FWD EMER EXIT DISPLAYED ON UPPER ECAM SCREEN. DOOR REINSTALLED LEFT FWD OW EXIT IAW AMM 52-21-11.SDR CALA2016111100871Slide · unwanted deployLEFT FWD SLIDE INADVERTENTLY DEPLOYED. REPLACED LEFT OVERWING SLIDE ASSY AND INFLATION RESERVOIR IAW AM M 25-62-42 AND 25-62-46. OP CHECKED OK.SDR AALA201612069002Skin · crackedCRACK INDINCATIONS AT TWO FASTENER HOLES ON SKIN AT FRAME 36. REPAIRED THE SKIN IAW EA 264972.SDR AALA201612069001Fitting · crackedCRACK INDINCATIONS AT TWO FASTENER HOLES ON FITTING AT FRAME 36. REPAIRED THE FITTING IAW EA 264972.SDR AALA201611119002Cover · damagedAIRCRAFT WAS GROUNDED. EMERGENCY EXIT COVER LIGHT DAMAGED AT DOOR 2R. REPLACED DOOR 2R EXIT LIGHT ASSEMBLY PER AMM 33-51-13 AND ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR AALA201611109006Coffeemaker · sparksAIRCRAFT WAS NOT GROUNDED. FORWARD NR 1 COFFEEMAKER SPARKS WHEN TURNED ON, NOW INOPERABLE. REPLACED COFFEEMAKER PER AMM 25-35-15.SDR GTIA2016110901655Oxygen Mask · damagedCHUNK OF PLASTIC FELL OFF FO'S OXYGEN SQUEEZE (RED) HANDLE ON THE OXYGEN MASK. REMOVED AND REPLACED OXYGEN MASK IAW AMM 35-12-41, OPS TESTED GOOD.SDR YENA20161108976Door Sill · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS FOUND ON DOOR SILL FRAME 66. THE CORROSION WAS REMOVED IAW SRM TASK 53-41-14-300-001.SDR YENA20161108975Door Sill · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS FOUND ON DOOR SILL AT FRAME 68. REMOVED THE CORROSION IAW SRM TASK 53-41-14-300-001.SDR YENA20161108974Shear Tie · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS FOUND ON FRAME SUPPORT BTW FRAMES 69-70 23L. R & R THE FRAME SUPPORT IAW SRM 51-72-11.SDR YENA20161108973Shear Tie · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS FOUND ON FRAME SUPPORT BETWEEN FRAMES 69-70 STRINGER 23R. R & R THE FRAME SUPPORT IAW SRM 51-72-11.SDR YENA20161107967Power Supply · failedFT 1973, EMERGENCY LIGHT FAILED TEST. R & R FWD POWER SUPPLY UNIT 10WL. OPS CHECK WAS PERFORMED. OPS CHECK PASSED IAW AMM 33-51-38.SDR AALA201611079003Lens · damagedEMERGENCY EXIT LIGHT LENS AT SEAT 1C DAMAGED. MAINTENANCE INSTALLED NEW EMERGENCY LIGHT HOLDER AT SEAT 1C. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR YENA20161104972Floor Support · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR SUPPORT -Y1292 AT FRAME 68. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 53-72-11.SDR YENA20161104971Floor Support · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON INSIDE CABIN LEFT SIDE OF FLOOR SUPPORT Y765 AT FRAMES 68-69. REMOVED AND REPLACED FLOOR SUPPORT IAW SRM 51-72-11.SDR YENA20161104970Floorbeam · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON INSIDE RIGHT SIDE OF FLOORBEAM -Y1292 AT FR 66 STR 23R. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 53-41-14.SDR YENA20161104969Floorbeam · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON INSIDE CABIN RIGHT SIDE OF FLOORBEAM -Y1292 AT FRAME 67 +18, STR 23R; REMOVED AND REPLACED FLOORBEAM.SDR YENA20161104968Door Sill · corrodedDURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON INSIDE CABIN LEFT SIDE, ON L2 DOOR SILL BEAM AT FRAMES 67 +18 - 68, STRINGER 23L. FABRICATED, LOCATED, DRILLED AND INSTALLED REPAIR ANGLE AND FILLERS IAW SRM 53-51-14.SDR GTIA2016110301650Unknown · odorFUMES ODOR DURING CLIMB , ISOLATED BLEED 1 AND ODOR DISEPATED UNTIL DECENT THEN ODOR RETURNED EVEN MORE SEVERLY. PERFORMED OPS CK OF THE PACKS SYS REF AMM 21-63-00. NO DEFECTS NOTED ON EITHER PACK , NO CABIN ODOR DETECTED ON EITHER PACK.SDR CALA2016110495971Unknown · malfunctionedEMERGENCY EXIT LIGHTS STAY ON WITH POWER OFF. RESET LIGHTS, NOW OFF.SDR AALA201611049001Elec Connector · dirtyOVERHEAD CABIN EMERGENCY LIGHT AT ROWS 14 AND 15 INOPERATIVE. MAINTENANCE CLEANED AND SECURED THE ELETRICAL CONNECTOR ON EMERGENCY POWER SUPPLY UNIT 12WL AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-38.SDR CALA2016110400850Power Supply · inoperativeEMERGENCY LIGHT EPSU DOOR 1L INOP. REPLACED EPSU AT DOOR 1L REF AMM33-51-38. OPS TEST OK.SDR CALA2016110495970Frame · corrodedAFT FACE OF FR66 HAS CORROSION JUST ABOVE R2 DOOR SILL BEAM. BLENDED AFT FACE OF FR66 JUST ABOVE DOOR SILL BEAM AND FOUND TO BE OUT OF LIMITS ACP NDT OF HOLES AND SURFACE AREA IAW NTM 51-10-08 & 51-10-04 & NO DEFECTS FOUND. FABBED FR66 REPAIR FROM 7075-T7 .
Back to Airbus A320-232