What was found
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN WET AREA FLOOR BEAM Y-1292 STR23 R/H FRAME 66+6 ; REMOVED FLOORBEAM, LOCATED DRILLED, BEBURRED TREATED, PRIMED, INSTALLED IAW A320 SRM 53-00-14.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN WET AREA FLOOR BEAM Y-1292 STR23 R/H FRAME 66+6 ; REMOVED FLOORBEAM, LOCATED DRILLED, BEBURRED TREATED, PRIMED, INSTALLED IAW A320 SRM 53-00-14.